Panasonic Refrigeraor NR-B472TZ - B412TZ v1.1
Panasonic Refrigeraor NR-B472TZ - B412TZ v1.1
Panasonic Refrigeraor NR-B472TZ - B412TZ v1.1
1 Specifications
MODEL NR-B472TZ-S5
SPECIFICTIONS
Storage Capacity 448 L (PC : 338 L,FC : 110 L)
Gross Capacity 468 L (PC : 356 L,FC : 112 L)
Outside dimensions
Width 697 mm
Depth 754 mm
Height 1828 mm
Net weight 72 kg
Type Frost-free refrigerator
Temperature control Micro-computer control (FC:FCC sensor) / Full-automatic direct control (PC:Damper thermo.)
(CONDITION)
Atmosphere Temperature:32 degree
NO LOAD (NO FOODS), NO DOOR OPEN AND CLOSE
These indicating temperature is stable condition. (Approximately)
2.Introduction
FUNCTION OF ELECTRONIC CONTROL
※When the blue light is blinking after pressing the "QUICK FREEZING" button, the function of quick freezing
is waiting .The situation of refrigerator is processing as below:
a.The refrigerator is defrosting .
b.The compressor is stopped,because temperature of the freezing compartment reachs setting of temperature.
When the above situation is solved , quick- freeze will be started automatically,then the "QUICK FREEZING"
light bright is on.
Cumulating the compressor running time of certain period or time after defrosting according to AT temperature,
FC defrosting cycle starts. (AT temperature : Atmosphere temperature)
Termination is detected by defrost sensor ,but maximum defrosting time is 60 minutes (Defrosting forcibly stops).
(Example:Code"H07")
"MAX"LED: light off 1.The door of refrigerator 1.Close the refrigerator compartment
"MED"LED: light off compartment is opened. door
"MIN"LED: light off Refrigerator have not 2.Door switch is breakdown. 2.Replace door switch
1 U10 Door opened alarm.
"QUICK FREEZING" LED cooling 3.Control PCB is breakdown. 3.Replace Control PCB
: light on
"MAX"LED: light off Freezer compartment Compressor is stopped. 1.Check freezer compartment of 1.Replace freezer compartment of
"MED"LED: light off of sensor was open Refrigerator have not sensor. sensor.
"MIN"LED: light on circuit. cooling at all. 2.Check Control PCB of 2.Replace Control PCB.
"QUICK FREEZING" LED Freezer compartment Compressor is running connector. 3.Replace Control PCB.
: light off of sensor was short all the time. 3.Control PCB is breakdown.
2 H01
circuit. Refrigerator is over cooling
at all.
Freezer compartment Refrigerator have not
of sensor put error of cooling at all,or over
position cooling at all.
"MAX"LED: light off Defrost of sensor Thermal fuse was cut off 1.Check defrost of sensor. 1.Replace defrost of sensor.
"MED"LED: light off was open circuit. in freezer compartment 2.Check Control PCB of 2.Replace Control PCB.
"MIN"LED: light on Defrost of sensor The refrigerator have not connector. 3.Replace Control PCB.
3 H05 "QUICK FREEZING" LED was short circuit. defrosting . 3.Control PCB is breakdown.
: light on Defrost of sensor Evaporator have over frost
put error of position Refrigerator have not
cooling at all.
"MAX"LED: light off ATC of sensor Refrigerator is over cooling 1.Check ATC of sensor. 1.Replace defrost of sensor.
"MED"LED: light on was open circuit*. at all. 2.Check Control PCB of 2.Replace Control PCB.
"MAX"LED: light on Freezer compartment Refrigerator have not 1.Check defroster of heater. 1.Replace defroster of heater
"MED"LED: light on defrost abnormal defrosting. 2.Check Control PCB of 2.Replace Control PCB.
"MIN"LED: light on connector. 3.Replace Control PCB.
5 H31 "QUICK FREEZING" LED 3.Control PCB is breakdown.
: light on 4.Thermal fuse was cut off
in freezer compartment.
*ATC sensor is to measure atmosphere temperature . ATC sensor put on operation board.
No CODE Operation PCB Display Content Symptom Confirm point Solve
"MAX"LED: light off Protection of IPM for 1. "QUICK FREEZING" LED 1.Control PCB is breakdown. 1.Replace Control PCB.
"MED"LED: light on compressor lock indicate red bright.
"MIN"LED: light on
8 H40 "QUICK FREEZING" LED
: light off
"MAX"LED: light on Control PCB of 1. "QUICK FREEZING" LED 1.Control PCB is breakdown. 1.Replace Control PCB.
"MED"LED: light on communication is indicate red bright.
"MIN"LED: light on abnormal.
9 H50 "QUICK FREEZING" LED
: light off
"MAX"LED: light on Control PCB is 1. "QUICK FREEZING" LED 1.Control PCB is breakdown. 1.Replace Control PCB.
"MED"LED: light off abnormal. indicate red bright. 2.Check DFC of sensor. 2.Replace DFC of sensor
"MIN"LED: light on (DFC of sensor less 2. Refrigerator have not
10 H35 "QUICK FREEZING" LED then -41℃) cooling.
: light off
"MAX"LED: light on Control PCB is 1. "QUICK FREEZING" LED 1.Control PCB is breakdown. 1.Replace Control PCB.
"MED"LED: light off abnormal. indicate red bright. 2.Check DFC of sensor. 2.Replace DFC of sensor
"MIN"LED: light on (DFC of sensor more 2. Refrigerator have over
11 H36 "QUICK FREEZING" LED then 41℃) cooling.
: light on
"MAX"LED: light on Ambient brightness 1.Check Ambient brightness 1.Replace Control PCB.
NO YES
Check compressor is running or Check compressor side of *Reconnect compressor
not. connector dropped side of connector.
or not.
NO
YES
Check control PCB of *Reconnect control PCB
compressor of connector of compressor of
dropped or not. connector.
NO
‧Press "QUICK FREEZING" + "FREEZER CONTROL" both bottons 9~13 sec
"MAX"LED: light on
"MED"LED: light on *Replace control PCB.
"MIN"LED: light on YES
(Circuit problem happens between IC1
"QUICK FREEZING"LED: light off and IC 201).
CODE(H50)
NO
‧Press "QUICK FREEZING" + "FREEZER CONTROL"
*Replace door switch.
YES both bottons 9~13 sec (Faulty at door switch,
NO
freezer of compartment fan
motor stop running)
"MAX"LED: light off
"MED"LED: light off
"MIN"LED: light on YES
"QUICK FREEZING"LED: light off *Replace freezer of
CODE(H01) compartment sensor
(sensor open circuit).
NO
"MAX"LED: light on
"MED"LED: light on *Replace Defrost heater
"MIN"LED: light on YES NO
Is temperature fuse (heater open circuit).
"QUICK FREEZING"LED: light on breakdown? or *Replace Control PCB.
CODE(H31) (Faulty of relay on control
PCB)
NO
*Replace Defrost sensor
YES (sensor open circuit).
and *Replace temperature
fuse(fuse open circuit).
NEXT PAGE
4.3 Symptom 2. FC/PC are poor cooling.
NO
YES
*Replace control PCB.
(Faulty of defrost sensor of circuit
detected on control PCB)
5. Disassembly and Assmbly Instructions ICE TRAY RAIL
TEMP FUSE
DEFROST HEATER
Lead wire
HooK
HooK
DFC SENSOR
Lead wire
DIAL THERMO PC
Screw
Control panel
gently knock
PULL
Control panel
Pulling
Starting relay
Pushing
Mullion Side
COMP
Mullion Front
Mullion Front
Dryer
5.11 Refrigeration system diagram
Screw
Evaporator
CAPILLARY TUBE
COMP
DRYER JOINT PIPE
GAS CHARE PIPE ¢4 x t0.38 x 1/2H L=170
¢6.35 x t0.6 L=120
300mm
1646mm(NR-B412TZ)
1828mm(NR-B472TZ)
716mm
(500mm)
754mm 40mm
7. Wiring Connection Diagram
8. Schematic Diagram
9. Location and Replacement Parts List
9.1.1 Location of Parts
NR-B412TZ
9.1.2 Location of Parts
NR-B472TZ
9.1.3 Replacement Parts List
Ref.No Service Parts No. Parts Name & Description B412TZ-S5 B472TZ-S5 PCS/SET NOTE