Test Equipment Solutions Datasheet

Test Equipment Solutions Ltd specialise in the second user sale, rental and distribution of
quality test & measurement (T&M) equipment. We stock all major equipment types such as
spectrum analyzers, signal generators, oscilloscopes, power meters, logic analysers etc from
all the major suppliers such as Agilent, Tektronix, Anritsu and Rohde & Schwarz.

We are focused at the professional end of the marketplace, primarily working with customers
for whom high performance, quality and service are key, whilst realising the cost savings that
second user equipment offers. As such, we fully test & refurbish equipment in our in-house,
traceable Lab. Items are supplied with manuals, accessories and typically a full no-quibble 2
year warranty. Our staff have extensive backgrounds in T&M, totalling over 150 years of
combined experience, which enables us to deliver industry-leading service and support. We
endeavour to be customer focused in every way right down to the detail, such as offering free
delivery on sales, covering the cost of warranty returns BOTH ways (plus supplying a loan
unit, if available) and supplying a free business tool with every order.

As well as the headline benefit of cost saving, second user offers shorter lead times, higher
reliability and multivendor solutions. Rental, of course, is ideal for shorter term needs and
offers fast delivery, flexibility, try-before-you-buy, zero capital expenditure, lower risk and off
balance sheet accounting. Both second user and rental improve the key business measure of
Return On Capital Employed.

We are based near Heathrow Airport in the UK from where we supply test equipment
worldwide. Our facility incorporates Sales, Support, Admin, Logistics and our own in-house
Lab.

All products supplied by Test Equipment Solutions include:

- No-quibble parts & labour warranty (we provide transport for UK mainland addresses).
- Free loan equipment during warranty repair, if available.
- Full electrical, mechanical and safety refurbishment in our in-house Lab.
- Certificate of Conformance (calibration available on request).
- Manuals and accessories required for normal operation.
- Free insured delivery to your UK mainland address (sales).
- Support from our team of seasoned Test & Measurement engineers.
- ISO9001 quality assurance.

Test equipment Solutions Ltd


Unit 8 Elder Way
Waterside Drive
Langley
Berkshire
SL3 6EP

T: +44 (0)1753 596000


F: +44 (0)1753 596001

Email: info@TestEquipmentHQ.com
Web: www.TestEquipmentHQ.com
Agilent Technologies
3000 Series Oscilloscopes

Data Sheet

Full-featured oscilloscopes for the smallest budgets

Features:

• 60 to 200 MHz bandwidths

• 1 GSa/s maximum sample rate

• Large 15-cm (5.7-in) color display

• Advanced triggering including


edge, pulse width, and line-
selectable video

• 4 kpts of waveform memory

• USB host and device connectivity,


standard

• 20 automatic measurements plus


hardware counter and Measure All

• Four math functions, including


FFTs standard
Get more for your money to 200-MHz. To give you the
• Mask test standard debugging power you need, each
Agilent’s 3000 Series oscilloscopes oscilloscope comes standard
• GPIB and RS-232 connectivity and give you an affordable way to with advanced features including
SCPI programming available with see what’s happening in your sophisticated triggering,
N2861A communications module designs. Developed with the automatic measurements,
features you need to make your digital filtering, sequence mode
• Interface localized into job easier – including a large LCD acquisition,
12-languages color display. Need flexibility? math functions (including FFTs),
Choose from four models with stored setups and waveforms,
• Sequence mode (segmented bandwidths ranging from 60-MHz mask testing and much more.
memory) standard
See your signals more clearly

All 3000 Series models have color


displays to allow you to quickly
identify your signals, and the
large size – 15-cm (5.7-in) with
320 x 240 resolution – makes
it easier for you to see more
information.

The 3000 Series’ delayed sweep


also lets you see more details in
your design. You can view a long
record, then window in on the
section of the signal of interest.

Figure 1. All 3000 Series oscilloscopes come standard with


a color display and cost 20% less than competitive products.
The color display allows you to quickly and easily identify your
signals and view signal activity.

Figure 2. Want to see the big picture but still get all the
details? Use the delayed sweep mode to zoom in on a
particular area of interest on your signal while still viewing
the entire captured waveform.

2
The features you need

All 3000 Series scopes include the This scope series also offers Waveform math with FFTs
standard features you need to get Scope Connect software, which – Analysis functions include
your job done easier and faster: provides PC connectivity for data addition, subtraction,
gathering, pass/fail testing, and multiplication, and Fast Fourier
Autoscale – Autoscale lets you analysis via the 3000 Series' USB Transforms with four windows
quickly display any active signals, device port. (Hanning, Hamming, Blackman-
automatically setting the vertical, GPIB and RS-232 interfaces are Harris and rectangular).
horizontal and trigger controls for also available with the N2861A
the best signal display. connectivity module. Auto calibration – Automatically
calibrates the oscilloscope’s
Advanced triggering – vertical and horizontal systems.
Easy connectivity – The 3000 Includes edge, pulse width and
Series oscilloscopes come line-selectable video, to help you Multi-language interface –
standard with an N2865A USB isolate the signals you want to Operate the oscilloscope in
host module for saving setups, see. the language of your choice.
waveforms and displays to a Language support includes
memory stick. This port is also 20 automatic measurements – simplified and traditional
compatible with many USB To save time, you can make Chinese, Japanese, Korean,
printers. 18 different measurements French, German, Italian,
simultaneously. Portuguese, Russian, Spanish
and English.

Figure 3. The 3000 Series comes equipped with a broad set Figure 4. Standard USB host and device ports allow you to
of measurement and math features, including FFTs at no send your measurements directly to your PC or save them
additional cost. You can choose between 4 FFT windows to Flash memory sticks.
for your specific measurement needs: Hanning, Hamming,
Blackman-Harris, and rectangular.

3
The features you need (continued)

Digital filtering – Digital filtering Figure 5. The digital


selections include low pass, high filter capability
pass, band pass, and band reject enhances your
filters. Limits are selectable ability to examine
important signal
between 1-kHz and the bandwidth
components
of your oscilloscope model. by filtering out
undesired spectral
Ten waveform and setup components such
memories – Store waveforms or as various types
commonly used setups for future of noise.
reference and use.

Mask testing – Automatically


compares incoming signals with
a pre-defined mask, clearly
highlighting signal changes.

Sequence mode (segmented


memory) – Frame an area
of interest on your signal for Figure 6. Use the
acquisition and record up to sequence mode
1,000 frames for playback. to frame an area
of interest on
Pulse triggering – Lets you your signal for
acquisition; then,
trigger on pulse events.
use the playback
feature to quickly
3-year warranty – All 3000 play through the
Series scopes include a full 3-year sequence and
warranty. easily spot glitches
or other signal
Easy to set up and use anomalies.
– Dedicated, color-coded knobs
for vertical sensitivity, offset, and
time base settings make it easy to
set up and use. Front-panel keys
for triggering functions are also
grouped to make your job easier.

Figure 7. With dedicated, color-coded


knobs and front-panel keys grouped
by function, it is easy to find and use
all of the features of the scope – from
the most basic to the more advanced
functions.

4
Performance characteristics

Performance characteristics

Bandwidth* DSO3062A: 60 MHz


DSO3102A: 100 MHz
DSO3152A: 150 MHz
DSO3202A: 200 MHz

Real time sample rate


2 channels interleaved 1 GSa/s
Each channel 500 MSa/s
Equivalent time sample rate 50 GSa/s

Channels 2

Display Color, 320 x 240 1/4 VGA LCD; H: 88 mm, W: 116 mm

Memory 4 kpts per channel; 1.200 pts in roll mode

Vertical resolution 8 bits

Vertical sensitivity 2 mV/div to 5 V/div (5ns/div to 50 s/div in DSO3062A)

DC gain accuracy ± 3% for 10 mV/div to 5 V/div; ± 4% for 2 mV/div to 5 mV/div

Vertical zoom Vertical expand

Maximum input voltage 300 Vrms CAT II; derated at 20 dB/decade above 100 kHz to 13 V p-p AC at 3 MHz and above

Time base range 2 ns/div to 50 s/div (5 ns/div to 50 s/div in DSO3062A)

BW limit ~ 20 MHz

Input coupling DC, AC, Ground

Input impedance 1 MΩ: ≈ 13 pF

Time base accuracy 100 ppm

* Denotes warranted specifications, all others are typical. Specifications are valid after a 30-minute warm-up period and ±10 °C from firmware calibration temperature.

5
Performance characteristics (continued)

Performance characteristics (continued)

Acquisition modes
Normal Displays sampled data directly to the screen in real time
Averaging Selectable from 2, 4, 8, 16, 32, 64, 128 or 256
Peak detect Captures high-frequency glitches as narrow as 10 ns when viewing signals at slower sweep
speeds (slower than 5 µs/div)

Sweep modes Auto, Normal, Single

Trigger coupling AC, DC, LF reject, HF reject

Trigger modes
Force Triggers immediately when front-panel button is pushed
Edge Triggers on the positive or negative slope on any channel
Video Triggers on one of three standard television waveforms: NTSC, PAL, SECAM
Pulse triggering Triggers on a pulse width greater than, equal to, or less than a specified time limit, with time lim-
its
ranging from 20 ns to 10 s

Trigger source Ch 1, 2, Ext, Ext/5, Line (edge mode only)

Cursors
Modes Manual, auto, track
Type Time and voltage
Measurements ∆T, ∆V, frequency

Automatic measurements 20 plus 5-digit hardware counter


Voltage Peak-to-peak, maximum, minimum, average, amplitude, top, base, Vrms, overshoot, preshoot
Time Frequency, period, +width, –width, +duty cycle, –duty cycle, rise time, fall time, delay.

Math functions Add, subtract, multiply, FFT

FFT
Window modes Hanning, Hamming, Blackman-Harris, rectangular
Sample size 1024 points

Autoscale Single button automatic setup of all channels

Display 1/4 VGA (320 x 240), passive color LCD with adjustable brightness
Interpolation Sin(x)/x
Display types Dots and vectors
Persistence Off, infinite
Format YT and XY

6
Performance characteristics (continued)

I/O

Standard ports USB device port (Requires Scope Connect software for use)
N2865A DSO3000 Series USB host module

Optional ports GPIB, RS-232 w/N2861A Communication Module

Maximum data transfer rates GPIB: 500 kbytes/sec

Tested Printers

HP Deskjets 6940, 6988

HP LaserJets 3050, 3055

HP OfficeJet All In One 5610, J5780

HO OfficeJet Pro K5400

General characteristics

Physical size 30 cm wide x 15 cm high x 29 cm deep (without handle)


34.6 cm wide x 18.2 cm high x 29 cm deep (with handle)

Weight Net: 4.8 kgs (10.5 lbs)


Shipping: 7 kgs (15 lbs)

Power requirements

Line voltage range 100-240 VAC, CAT II, automatic selection

Line frequency 47 Hz to 440 Hz

Power usage 50 VA

Environmental characteristics

Ambient temperature Operating 0 °C to +55 °C; non-operating –40 °C to +70 °C

Humidity Operating 95% RH at 40 °C for 24 hr; non-operating 90% RH at 65 °C for 24 hr

Altitude Operating to 4,570 m (15,000 ft); non-operating to 15,244 m (50,000 ft)

Vibration Agilent class B1

Shock Agilent class B1

Pollution degree2 Normally only dry non-conductive pollution occurs.


Occasionally a temporary conductivity caused by condensation must be expected.

7
Ordering information

Model number Description

DSO3062A 60 MHz 2-ch DSO

DSO3102A 100 MHz 2-ch DSO

DSO3152A 150 MHz 2-ch DSO

DSO3202A 200 MHz 2-ch DSO

Accessories included
Quick Start manual, CD-ROM with User’s Guide (French, German,
Japanese, Korean, Russian, Simplified Chinese, and English) and
Programmer’s Manual, power cord, accessory pouch, two passive
probes, Scope Connect software

Optional accessories

Description

N2861A Provides GPIB and RS-232 connectivity and


(communication module) pass/fail output for automatic testing.

N2862A 150 MHz passive probe (standard with the


DSO3062A, DSO3102A, and DSO3152A
oscilloscopes.)

N2863A 300 MHz passive probe (standare with the


DSO3201A oscilloscope.)

N2864A Rack mount kit for the DSO3000 series


oscilloscope.)

Warranty options
All models include a standard 3-year warranty. Contact your local
sales office for prices of extended options:

8
Ordering information (continued)

Passive probes To get a Quick Quote on Agilent


3000 Series oscilloscopes, go to
Product number Description www.agilent.com/find/dso3000
N2862A 10:1, 150 MHz passive probe (shipped with DSO3062A,
DSO3102A, DSO3152A) Call the measurement experts at
Agilent Technologies
N2863A 10:1, 300 MHz passive probe (shipped with DSO3202A) Whether your work is mostly
digital, mostly analog, or
10070C 1:1, 20MHz passive probe somewhere in the middle, our
measurement specialists can help
you select the best debugging
Current probes solution. Call today to talk to a
knowledgeable engineer about
Product number Description
your particular application.
N2774A 50 MHz current probe, AC/DC

N2775A Power supply for N2774A

1146A 100 kHz current probe, AC/DC

High-voltage probes

Product number Description

10076A 100:1, 4 kV, 250 MHz high-voltage probe

N2771A 1000:1, 15 kV, 50 MHz high-voltage probe

Differential probes

Product number Description

1141A 200 MHz differential probe. Requires 1142A power supply

N2772A 600 V CAT III, 20 MHz differential probe.

Cables

Product number Description

10833A GPIB cable, 1 m long

9
Agilent Technologies Oscilloscopes
Multiple form factors from 20 MHz to >90 GHz | Industry leading specs | Powerful applications

10
Remove all doubt www.agilent.com
www.agilent.com/find/emailupdates Our repair and calibration services For more information on Agilent
Get the latest information on the products will get your equipment back to you, Technologies’ products, applications
and applications you select. performing like new, when promised. or services, please contact your local
You will get full value out of your Agilent Agilent office. The complete list is
equipment throughout its lifetime. available at:
Your equipment will be serviced by
Agilent Direct
Agilent-trained technicians using the www.agilent.com/find/contactus
www.agilent.com/find/quick
latest factory calibration procedures,
Quickly choose and use your test
automated repair diagnostics and Phone or Fax
equipment solutions with confidence.
genuine parts. You will always
have the utmost confidence in your United States:
(tel) 800 829 4444
measurements.
Agilent Open (fax) 800 829 4433

www.agilent.com/find/open Agilent offers a wide range of additional Canada:


Agilent Open simplifies the process of expert test and measurement services (tel) 877 894 4414
connecting and programming test systems for your equipment, including initial (fax) 800 746 4866
to help engineers design, validate and start-up assistance onsite education
China:
manufacture electronic products. Agilent and training, as well as design, system (tel) 800 810 0189
offers open connectivity for a broad range integration, and project management. (fax) 800 820 2816
of system-ready instruments, open industry
software, PC-standard I/O and global For more information on repair and Europe:
calibration services, go to (tel) 31 20 547 2111
support, which are combined to more eas-
ily integrate test system development. Japan:
www.agilent.com/find/removealldoubt (tel) (81) 426 56 7832
(fax) (81) 426 56 7840
Microsoft® and Windows® are U.S.
registered trademarks of Microsoft Korea:
Corporation. (tel) (080) 769 0800
Pentium® is a U.S. registered trademark of (fax) (080) 769 0900
Intel Corporation.
Latin America:
(tel) (305) 269 7500

Taiwan:
(tel) 0800 047 866
(fax) 0800 286 331

Other Asia Pacific Countries:


(tel) (65) 6375 8100
(fax) (65) 6755 0042
Email: tm_ap@agilent.com
Revised: 09/14/06

Product specifications and descriptions


in this document subject to change
without notice.

© Agilent Technologies, Inc. 2008


Printed in USA, June 25, 2008
5989-2235EN

You might also like