TBS1000B Series Oscilloscope Datasheet 3GW30004
TBS1000B Series Oscilloscope Datasheet 3GW30004
TBS1000B Series Oscilloscope Datasheet 3GW30004
Connectivity
USB 2.0 host port on the front panel for quick and easy data storage
USB 2.0 device port on rear panel for easy connection to a PC
Key features
7 inch WVGA (800X480) Active TFT Color Display
34 automated measurements The zoom function shows details in an event of up to 10X the normal view.
www.tek.com 1
Datasheet
A dedicated front panel button provides quick access to the FFT function
that is capable of showing both frequency and time domain waveforms
simultaneously, which provides a convenient way to see the relationship
between signals and the FFT results.
See all the details other oscilloscopes might miss with Tektronix proprietary digital real-
time sampling.
Once signals are captured, the TBS1000B offers advanced math and
measurement capabilities making it easy to evaluate signal quality . Users
can add, subtract and multiply waveforms or use any one of 34 automated
measurements to quickly and reliably calculate important signal
characteristics such as frequency, rise time or overshoot.
Dual channel - 6 digit frequency counters come standard with all TBS1000 models.
2 www.tek.com
TBS1000B Digital Storage Oscilloscopes
To find intermittent faults the TrendPlot ™ function can monitor measurements for long Data logging enables automatic saving of triggered waveforms.
periods of time.
The Limit Test feature provides a quick Pass/Fail comparison between any triggered
input signal and a user- defined template.
www.tek.com 3
Datasheet
Help when you need it, where you need it Performance you can count on
The built-in Help menu provides you with important information about your In addition to industry-leading service and support, every TBS1000B series
oscilloscope's features and functions. Help is provided in the same oscilloscope comes backed with a 5-year warranty as standard.
languages as the user interface.
The context-sensitive help system provides important information specific to the task you
are working on.
4 www.tek.com
TBS1000B Digital Storage Oscilloscopes
Specifications
All specifications are guaranteed unless noted otherwise. All specifications apply to all models unless noted otherwise.
Model overview
TBS1032B 2 TBS1052B TBS1072B TBS1102B TBS1152B TBS1202B
Bandwidth 30 MHz 50 MHz 70 MHz 100 MHz 150 MHz 200 MHz
Channels 2 2 2 2 2 2
Sample rate on each channel 500 MS/s 1.0 GS/s 1.0 GS/s 2 .0 GS/s 2 .0 GS/s 2 .0 GS/s
Record length 2.5k points at all-time bases
Input sensitivity range 2 mV to 5 V/div on all models with calibrated fine adjustment
Maximum input voltage 300 VRMS CAT II; derated at 20 dB/decade above 100 kHz to 13 Vp-p AC at 3 MHz and above
www.tek.com 5
Datasheet
Input/Output ports
USB interface USB host port on front panel supports USB flash drives USB device port on back of instrument supports connection to PC and all
PictBridge®-compatible printers
Data storage
Nonvolatile storage
Reference waveform display 2.5K point reference waveforms
Waveform storage without 2.5K point
USB flash drive
Maximum USB flash drive size 64 GB
Waveform storage with USB 96 or more reference waveforms per 8 MB
flash drive
Setups without USB flash 10 front-panel setups
drive
Setups with USB flash drive 4000 or more front-panel setups per 8 MB
Screen images with USB flash 128 or more screen images per 8 MB (the number of images depends on file format selected)
drive
Save All with USB flash drive 12 or more Save All operations per 8 MB
A single Save All operation creates 3 to 9 files (setup, image, plus one file for each displayed waveform)
Acquisition system
Acquisition modes
Peak Detect High-frequency and random glitch capture. Captures glitches as narrow as 12 ns (typical) at all time base settings from 5 μs/div to
50 s/div
Sample Sample data only
Average Waveform averaged, selectable: 4, 16, 64, 128
Single Sequence Use the Single Sequence button to capture a single triggered acquisition sequence
Roll At acquisition time base settings of >100 ms/div
Trigger system
External trigger input Included on all models
Trigger types
Edge (Rising/Falling) Conventional level-driven trigger. Positive or negative slope on any channel. Coupling selections: AC, DC, Noise Reject, HF
Reject, LF Reject
Video Trigger on all lines or individual lines, odd/even or all fields from composite video, or broadcast standards (NTSC, PAL, SECAM)
Pulse Width (or Glitch) Trigger on a pulse width less than, greater than, equal to, or not equal to, a selectable time limit ranging from 33 ns to 10 s
Trigger source Two channel models: CH1, CH2, Ext, Ext/5, AC Line
Trigger view Displays trigger signal while Trigger View button is depressed.
Trigger signal frequency readout Provides a frequency readout of the trigger source.
6 www.tek.com
TBS1000B Digital Storage Oscilloscopes
Waveform measurements
Cursors
Types Amplitude, Time
Measurements ΔT, 1/ΔT, ΔV
Automatic measurements Period, Frequency, Pos Width, Neg Width, Rise Time, Fall Time, Maximum , Minimum , Peak-Peak, Mean, RMS, Cycle RMS,
Cursor RMS, Phase, Pos Pulse Cnt, Neg Pulse Cnt, Rise Edge Cn, Fall Edge Cn, Pos Duty, Neg Duty, Amplitude, Cycle Mean,
Cursor Mean, Burst Width, Pos Overshoot, Neg Overshoot, Area, Cycle Area, High, Low, Delay RR, Delay RF, Delay FR, Delay
FF
Waveform math
Arithmetic Add, Subtract, Multiply
Sources Two channel models: CH1 - CH2, CH2 - CH1, CH1 + CH2, CH1 × CH2
Autoset
Autoset menu Single-button, automatic setup of all channels for vertical, horizontal, and trigger systems, with undo Autoset
Square wave Single Cycle, Multicycle, Rising or Falling Edge
Sine wave Single Cycle, Multicycle, FFT Spectrum
Video (NTSC, PAL, SECAM) Field: All, Odd, or Even Line: All or Selectable Line Number
Autorange
Automatically adjust vertical and/or horizontal oscilloscope settings when probe is moved from point to point, or when the signal
exhibits large changes.
Frequency counter
Resolution 6 digits
Accuracy (typical) + 51 parts per million including all frequency reference errors and +1 count errors
Frequency counter signal source Pulse width or edge selected trigger source
Frequency counter measures selected trigger source at all times in pulse width and edge mode, including when the oscilloscope
acquisition is halted due to changes in run status, or acquisition of a single shot event has completed.
The frequency counter does not measure pulses that do not qualify as legitimate trigger events.
Pulse Width mode: Counts pulses of enough magnitude inside the 250 ms measurement window that qualify as triggerable events
(e.g. all narrow pulses in a PWM pulse train if set to "<" mode and the limit is set to a relatively small number).
Edge Trigger mode: Counts all pulses of enough magnitude.
Channels 2 channel
www.tek.com 7
Datasheet
Display system
Interpolation Sin (x)/x
Format YT and XY
Power source
Power source voltage 100 to 240 V ±10%
Physical characteristics
Dimensions mm in.
Height 158.0 6.22
Width 326.3 12.85
Depth 124.2 4.89
Weight kg lb.
Instrument only 2.0 4.3
...with accessories 2.2 4.9
RM2000B rackmount mm in
Width 482.6 19.0
Height 177.8 7.0
Depth 108.0 4.25
8 www.tek.com
TBS1000B Digital Storage Oscilloscopes
Environmental
Temperature
Operating 0 to +50 ºC
Nonoperating –40 to +71 ºC
Humidity
Operating and nonoperating Up to 85% RH at or below +40 ºC
Up to 45% RH up to +50 ºC
Altitude
Operating and nonoperating Up to 3,000 m (9,843 ft.)
Regulatory
Electromagnetic compatibility Meets Directive 2004/108/EC, EN 61326-2-1 Class A; Australian EMC Framework
Safety UL61010-1:2004, CSA22.2 No. 61010-1:2004, EN61010-1:2001, IEC61010-1:2001
www.tek.com 9
Datasheet
Ordering information
Models
TBS1032B 4 30 MHz, 2 Ch, 500 MS/s, TFT DSO
Language options
Opt. L1 French overlay
10 www.tek.com
TBS1000B Digital Storage Oscilloscopes
Service options
Opt. D1 Calibration Data Report
Probes and accessories are not covered by the oscilloscope warranty and Service Offerings. Refer to the datasheet of each probe and accessory model for its unique warranty
and calibration terms.
Probe option
TBS1XX2B P2220 Replaces standard probes with P2220 probes (200 MHz passive voltage probes with 1x/ 10x attenuation)
Standard accessories
Accessory Description
Passive probes, one per channel TPP0051: 50MHz passive probe for: TBS1032B 6, TBS1052B
TPP0101: 100 MHz passive probe for: TBS1072B, TBS1102B
TPP0201: 200 MHz passive probe for: TBS1152B, TBS1202B
Power cord (Please specify plug option)
NIM/NIST Traceable certificate of calibration
Printed documentation Installation and safety manual
(English, Japanese, and Simplified Chinese)
CD with customer documentation Customer documentation including detailed user manuals (English, French, German, Italian, Japanese, Korean,
Portuguese, Russian, Simplified Chinese, Spanish, Traditional Chinese)
5-year warranty Covers labor and parts for defects in materials and workmanship for 5 years, excluding probes and accessories
(probes and accessories are not covered by the oscilloscope warranty and service offerings. refer to the data sheet
of each probe and accessory model for its unique warranty and calibration terms)
Recommended accessories
Accessory Description
TEK-USB-488 GPIB-to-USB converter
AC2100 Soft carrying case for instrument
HCTEK4321 Hard plastic carrying case for instrument (requires AC2100)
RM2000B Rackmount kit
077-0444-xx Programmer manual – English only
077-0772-xx Service manual – English only
174-4401-xx USB host to device cable, 3 ft. long
www.tek.com 11
Datasheet
Recommended probes
Probe Description
TPP0051 10X passive probe, 50 MHz bandwidth
TPP0101 10X passive probe, 100 MHz bandwidth
TPP0201 10X passive probe, 200 MHz bandwidth
P2220 1X/10X passive probe, 200 MHz bandwidth
P6101B 1X passive probe (15 MHz, 300 V RMS CAT II rating)
P6015A 1000X high-voltage passive probe (75 MHz)
P5100A 100X high-voltage passive probe (500 MHz)
P5200A 50 MHz, 50X/500X high-voltage differential probe
P6021A 15 A, 60 MHz AC current probe
P6022 6 A, 120 MHz AC current probe
A621 2000 A, 5 to 50 kHz AC current probe
A622 100 A, 100 kHz AC/DC current probe/BNC
TCP303/TCPA300 150 A, 15 MHz AC/DC current probe/amplifier
TCP305A/TCPA300 50 A, 50 MHz AC/DC current probe/amplifier
TCP312A/TCPA300 30 A, 100 MHz AC/DC current probe/amplifier
TCP404XL/TCPA400 500 A, 2 MHz AC/DC current probe/amplifier
Tektronix is registered to ISO 9001 and ISO 14001 by SRI Quality System Registrar.
Product(s) complies with IEEE Standard 488.1-1987, RS-232-C, and with Tektronix Standard Codes and Formats.
ASEAN / Australasia (65) 6356 3900 Austria 00800 2255 4835* Balkans, Israel, South Africa and other ISE Countries +41 52 675 3777
Belgium 00800 2255 4835* Brazil +55 (11) 3759 7627 Canada 1 800 833 9200
Central East Europe and the Baltics +41 52 675 3777 Central Europe & Greece +41 52 675 3777 Denmark +45 80 88 1401
Finland +41 52 675 3777 France 00800 2255 4835* Germany 00800 2255 4835*
Hong Kong 400 820 5835 India 000 800 650 1835 Italy 00800 2255 4835*
Japan 81 (3) 6714 3010 Luxembourg +41 52 675 3777 Mexico, Central/South America & Caribbean 52 (55) 56 04 50 90
Middle East, Asia, and North Africa +41 52 675 3777 The Netherlands 00800 2255 4835* Norway 800 16098
People's Republic of China 400 820 5835 Poland +41 52 675 3777 Portugal 80 08 12370
Republic of Korea +822 6917 5084, 822 6917 5080 Russia & CIS +7 (495) 6647564 South Africa +41 52 675 3777
Spain 00800 2255 4835* Sweden 00800 2255 4835* Switzerland 00800 2255 4835*
Taiwan 886 (2) 2656 6688 United Kingdom & Ireland 00800 2255 4835* USA 1 800 833 9200
* European toll-free number. If not accessible, call: +41 52 675 3777
For Further Information. Tektronix maintains a comprehensive, constantly expanding collection of application notes, technical briefs and other resources to help engineers working on the cutting edge of technology. Please visit www.tek.com.
Copyright © Tektronix, Inc. All rights reserved. Tektronix products are covered by U.S. and foreign patents, issued and pending. Information in this publication supersedes that in all previously published material. Specification and
price change privileges reserved. TEKTRONIX and TEK are registered trademarks of Tektronix, Inc. All other trade names referenced are the service marks, trademarks, or registered trademarks of their respective companies.
www.tek.com