Instruction Manual

Form 5469
67C Series
March 2012

67C Series Instrument Supply Regulators

W7412 W8438

TYPE 67CF FILTER REGULATOR TYPE 67C OR 67CR REGULATOR


WITH OPTIONAL GAUGE

Figure 1. 67C Series Regulators

Introduction
Scope of the Manual • The Types 67CF and 67CFS are equipped with a
filter for removing particles from the supply gas.
This manual provides instructions and parts lists for
67C Series instrument supply regulators. Instructions • The Types 67CR and 67CSR have an internal
and parts lists for other equipment mentioned in this relief valve with a soft seat for reliable shutoff with
instruction manual, as well as for other 67 Series no discernible leakage.
regulators, are found in separate manuals. • The Types 67CFR and 67CFSR have a filter and
internal relief valve with a soft seat for reliable
Product Descriptions shutoff with no discernible leakage.

The 67C Series direct-operated regulators are


typically used to provide constantly controlled,
Principle of Operation
reduced pressures to pneumatic and electropneumatic Downstream pressure is registered internally on the
controllers and other instruments. They are suitable lower side of the diaphragm. When the downstream
for most air or gas applications. Other applications pressure is at or above the set pressure, the valve plug
include providing reduced pressures to air chucks, air is held against the orifice and there is no flow through
jets, and spray guns. the regulator. When demand increases, downstream
pressure drops slightly allowing the spring to extend,
• The Types 67C and 67CS are the standard
moving the stem down and the valve plug away from
instrument supply regulators without a filter or
the orifice. This allows flow through the regulator.
internal relief.
D102601X012

www.fisherregulators.com
67C Series
Specifications
The Specifications section gives some general specifications for the 67C Series regulator. A label on the spring
case gives the control spring range for a given regulator as it comes from the factory.

Body Size, Inlet and Outlet Connection Style With Fluorocarbon (FKM):
1/4 NPT Polyethylene Filter(5) (Standard):
Maximum Inlet Pressure (Body Rating)(1) 0 to 180°F / -18 to 82°C
All except Types 67CS and 67CSR: Polyvinylidene (PVDF), SST, or Glass Filter (Optional):
0 to 300°F / -18 to 149°C
250 psig / 17.2 bar
Types 67CS and 67CSR: 400 psig / 27.6 bar With Silicone (VMQ)(3) Diaphragm and Low
Temperature bolting: -60 to 180°F / -51 to 82°C
Outlet Pressure Ranges     With Gauges: -40 to 180°F / -40 to 82°C
See Table 1
Smart Bleed™ Check Valve Setpoint
Maximum Emergency Outlet Pressure(1) 6 psi / 0.41 bar differential
50 psi / 3.4 bar over outlet pressure setting
Types 67CF, 67CFR, 67CFS, and 67CFSR
Wide-Open Flow Coefficients Filter Capabilities
Main Valve: Cg: 11.7; Cv: 0.36; C1: 32.2 Free Area: 12 times pipe area
Internal Relief Valve: Cg: 1.45; Cv: 0.045; C1: 32.8 Micron Rating:
Polyethylene Filter(5) (Standard): 5 microns
IEC Sizing Coefficients Glass Fiber Filter (Optional): 5 microns
Main Valve: XT: 0.66; FL: 0.89; FD: 0.50 PVDF or Stainless Steel Filter (Optional):
Accuracy 40 microns
Inlet Sensitivity: Less than 0.2 psig / 14 mbar Drain Valve and Spring Case Vent Location
change in outlet pressure for every 25 psig / Aligned with inlet standard, other positions optional
1.7 bar change in inlet pressure
Repeatability: 0.1 psig / 7 mbar(2) Pressure Registration
Air Consumption: Testing repeatedly shows Internal
no discernible leakage
Options
Types 67CR, 67CSR, 67CFR, and 67CFSR All Types
Internal Relief Performance •  Handwheel adjusting screw
Low capacity for minor seat leakage only; other •  Inlet screen
overpressure protection must be provided if inlet •  NACE MR0175 or NACE MR0103 construction(4)
pressure can exceed the maximum pressure rating •  Panel mount (includes spring case with 1/4 NPT
of downstream equipment or exceeds maximum    vent, handwheel, and panel mounting nut)
outlet pressure rating of the regulator. •  Closing cap (available on spring case with
   1/4 NPT vent)
Approximate Weights •  Fluorocarbon (FKM) elastomers for high
Types 67C, 67CR, 67CF, and 67CFR:    temperatures and/or corrosive chemicals
1 pound / 0.5 kg •  Silicone (VMQ) elastomers for cold temperatures
Types 67CS and 67CSR: •  Fixed Bleed Restriction
2.5 pounds / 1 kg •  Triple scale outlet pressure gauge (brass or
Types 67CFS and 67CFSR:    stainless steel)
4 pounds / 2 kg •  Stainless steel stem on the valve plug
•  Tire valve or pipe plug in second outlet
Temperature Capabilities(1) Types 67CFR and 67CFSR only
With Nitrile (NBR) •  Smart BleedTM internal check valve
Standard Bolting: -20 to 180°F / -29 to 82°C •  Large dripwell with manual or automatic drain
Stainless Steel Bolting: -40 to 180°F / -40 to 82°C Types 67CF and 67CFR only
•  Stainless steel drain valve

1. The pressure/temperature limits in this Instruction Manual and any applicable standard or code limitation should not be exceeded.
2. Repeatability is the measure of the regulator’s ability to return to setpoint consistently when traveling from steady state to transient to steady state.
3. Silicone (VMQ) is not compatible with hydrocarbon gas.
4. Product complies with the material requirements of NACE MR0175. Environmental limits may apply.
5. Do not use in high aromatic hydrocarbon service.

2
Month Year

Type XXXX 67C Series

TYPE 67CR OR 67CSR TYPE 67CF OR 67CFS

W8442

TYPE 67C OR 67CS

INLET PRESSURE
INLET PRESSURE

OUTLET PRESSURE
OUTLET PRESSURE W7433
SMART BLEED™ OPTION
ATMOSPHERIC PRESSURE
ATMOSPHERIC PRESSURE TYPE 67CFR OR 67CFSR TYPES 67CFR AND 67CFSR
LOADING PRESSURE
INTERMEDIATE PRESSURE Figure 2. 67C Series Operational Schematics
PILOT SUPPLY PRESSURE
Internal VACUUM
Relief PRESSURE
(Types 67CR, 67CSR, downstream of the regulator, thereby conserving
TANK PRESSURE plant air.
67CFR, andPRESSURE
VAPOR 67CFSR)
INLET PRESSURE
OUTLET PRESSURE
If for some reason, outside of normal
ATMOSPHERIC operating
PRESSURE Note
LOADING PRESSURE
conditions, the downstream pressure exceeds the
INTERMEDIATE During normal operation the check
setpoint of the regulator, the forcePRESSURE
created by the
PILOTwill
SUPPLY valve’s metal to metal seat allows
downstream pressure lift thePRESSURE
diaphragm until the
limited flow through the regulator from
diaphragm is lifted off the relief seat. This allows flow
the inlet to outlet, even when there is
through the token relief. The relief valve on the
no downstream demand. To prevent
Type 67CR, 67CSR, 67CFR, or 67CFSR is an
downstream pressure buildup, the Smart
elastomer plug that prevents leakage of air from the
Bleed option is only available with the
downstream to atmosphere during normal operation,
internal relief version of the 67 Series.
thereby conserving plant air.

Smart Bleed™ Airset Overpressure Protection


In some cases, it is desired to exhaust downstream The 67C Series regulators have maximum outlet
pressure if inlet pressure is lost or drops below the pressure ratings that are lower than their maximum
setpoint of the regulator. For example, if the regulator inlet pressure ratings. A pressure relieving or pressure
is installed on equipment that at times has no flow limiting device is needed if inlet pressure can exceed
demand but is expected to backflow on loss of inlet the maximum outlet pressure rating.
pressure. The Types 67CFR and 67CFSR can be Types 67CR, 67CSR, 67CFR, and 67CFSR have
ordered with the Smart Bleed option which includes a low capacity internal relief valve for minor seat
an internal check valve for this application. During leakage only. Other overpressure protection must be
operation, if inlet pressure is lost, or decreases below provided if the maximum inlet pressure can exceed
the setpoint of the regulator, the downstream pressure the maximum pressure rating of the downstream
will back flow upstream through the regulator and check equipment or exceeds the maximum outlet pressure
valve. This option eliminates the need for a fixed bleed rating of the regulator.

3
67C Series
Table 1. Outlet Pressure Ranges and Control Spring Data
CONTROL SPRING DATA
OUTLET PRESSURE RANGES
TYPES Wire Diameter Free Length
Color Material Part Number
psig bar Inch mm Inch mm
0 to 20 0 to 1.4 Green stripe GE07809T012 0.135 3.43 1.43 36.2
0 to 35 0 to 2.4 Silver Music T14059T0012 0.156 3.96 1.43 36.2
0 to 60 0 to 4.1 Blue stripe Wire T14058T0012 0.170 4.32 1.43 36.2
67C, 67CR, 0 to 125 0 to 8.6 Red stripe T14060T0012 0.207 5.26 1.43 36.2
67CF, and 67CFR
0 to 35 0 to 2.4 Silver stripe T14113T0012 0.156 3.96 1.43 36.2
0 to 60 0 to 4.1 Blue Inconel® T14114T0012 0.172 4.37 1.43 36.2
0 to 125 0 to 8.6 Red T14115T0012 0.207 5.26 1.43 36.2
0 to 20 0 to 1.3 Green 10C1729X012 0.135 3.43 1.50 38.1
0 to 35 0 to 2.4 Silver stripe T14113T0012 0.156 3.96 1.43 36.2
67CS, 67CSR,
0 to 60 0 to 4.1 Blue Inconel® T14114T0012 0.172 4.37 1.43 36.2
67CFS, and 67CFSR
0 to 125 0 to 8.6 Red T14115T0012 0.207 5.26 1.43 36.2
0 to 150 0 to 10.3 Black 10C1730X012 0.250 6.35 1.77 44.9
Inconel® is a marked own by Special Metals Corporation

Installation A regulator may vent some gas to the


atmosphere. In hazardous or flammable
Note gas service, vented gas may accumulate
and cause personal injury, death, or
If the regulator is shipped mounted on
property damage due to fire or explosion.
another unit, install that unit according to
Vent a regulator in hazardous gas service
the appropriate Instruction Manual.
to a remote, safe location away from air
intakes or any hazardous area. The vent
! WARNING line or stack opening must be protected
against condensation or clogging.
Personal injury, property damage,
equipment damage, or leakage due to Before installing a Type 67C, 67CR, 67CS, 67CSR,
escaping gas or bursting of pressure- 67CF, 67CFR, 67CFS, or 67CFSR regulator, be
containing parts may result if this sure the installation complies with the following
regulator is overpressured or is installed installation guidelines:
where service conditions could exceed
1. Regulator operation within ratings does not
the limits given in the Specifications
WARNING preclude the possibility of damage from debris in
section, or where conditions exceed any
the lines or from external sources. Regulators
ratings of the adjacent piping or piping
should be inspected for damage periodically and
connections. To avoid such injury or
after any overpressure condition.
damage, provide pressure-relieving or
pressure-limiting devices (as required 2. Only personnel qualified through training and
by the appropriate code, regulation, or experience should install, operate, and maintain a
standard) to prevent service conditions regulator. Make sure that there is no damage to or
from exceeding those limits. foreign material in the regulator. Also ensure that
all tubing and piping is free of debris.
The internal relief valve of the
Type 67CR, 67CSR, 67CFR, or 67CFSR 3. Install the regulator so that flow is from the IN to the
does not provide full overpressure OUT connection as marked on the regulator body.
protection. The internal relief valve is
4. For best drainage, orient the drain valve (key 2) to
designed for minor seat leakage only. If
the lowest possible point on the dripwell (key 5). This
maximum inlet pressure to the regulator
orientation may be improved by rotating the dripwell
exceeds maximum pressure ratings of
with respect to the body (key 1).
the downstream equipment or exceeds
maximum allowable outlet pressure of 5. A clogged spring case vent hole may cause the
the regulator, additional overpressure regulator to function improperly. To keep this
protection is required. vent hole from being plugged (and to keep the
spring case from collecting moisture, corrosive

4
67C Series
chemicals, or other foreign material) orient the vent or explosion of accumulated gas, never
to the lowest possible point on the spring case or adjust the control spring to produce an
otherwise protect it. outlet pressure higher than the upper
limit of the outlet pressure range for that
Inspect the vent hole regularly to make sure it is particular spring. If the desired outlet
not plugged. Spring case vent hole orientation pressure is not within the range of the
may be changed by rotating the spring case with control spring, install a spring of the
respect to the body. A 1/4 NPT spring case vent proper range according to the diaphragm
may be remotely vented by installing obstruction- parts maintenance procedure.
free tubing or piping into the vent. Protect the
remote vent by installing a screened vent cap on 2. If outlet pressure adjustment is necessary, monitor
the remote end of the vent pipe. outlet pressure with a gauge during the adjustment
procedure. The regulator is adjusted by loosening
6. For use in regulator shutdown, install upstream the locknut (key 18), if used, and turning the
block and vent valves and downstream block and adjusting screw or handwheel (key 19) clockwise to
vent valves (if required), or provide some other increase or counterclockwise to decrease the outlet
suitable means of properly venting the regulator pressure setting. Retighten the locknut to maintain
inlet and outlet pressures. Install a pressure gauge the adjustment position.
to monitor instruments on startup.
7. Apply a good grade of pipe compound to the external Shutdown
pipe threads before making connections, making sure
not to get the pipe compound inside the regulator. First, close the nearest upstream block valve and
then close the nearest downstream block valve
8. Install tubing fitting or piping into the 1/4 NPT (when used). Next, open the downstream vent valve.
inlet connection on the body (key 1) and into the Since the regulator remains open in response to the
1/4 NPT body outlet connection. decreasing downstream pressure, pressure between
the closed block valves will be released through the
9. The second 1/4 NPT outlet can be used for a gauge
open vent valve.
or other use. If not used, it must be plugged.

Installing a 67CF Series Regulator in an Maintenance


Existing Installation Regulator parts are subject to normal wear and
must be inspected and replaced as necessary. The
When installing a 67CF Series regulator in an existing frequency of inspection and replacement of parts
installation, it may be necessary to use spacers depends on the severity of service conditions and
(key 34, Figure 13) to adapt the installation. If the applicable codes and government regulations. Open
mounting bolts are too long, place a spacer on the the Type 67CF, 67CFR, 67CFS, or 67CFSR drain valve
bolt (see Figure 13). To be sure the regulator is (key 2) regularly to empty accumulated liquid from the
secure, the bolts should have at least two full threads dripwell (key 5).
of engagement.
Note
Startup and Adjustment
If sufficient clearance exists, the body
Key numbers are referenced in Figures 3 through 9. (key 1) may remain mounted on other
equipment or in a line or panel during
1. With proper installation completed and downstream maintenance unless the entire regulator
equipment properly adjusted, slowly open the will be replaced.
upstream and downstream shutoff valve (when
used) while using pressure gauges to monitor pressure.
! WARNING
! WARNING
To avoid personal injury, property
damage, or equipment damage caused
To avoid personal injury, property
by sudden release of pressure or
damage, or equipment damage caused
explosion of accumulated gas, do
by bursting of pressure containing parts

5
67C Series
not attempt any maintenance or Note
disassembly without first isolating the
In step 5, if installing a control spring of
regulator from system pressure and
a different range, be sure to delete the
relieving all internal pressure from
spring range originally appearing on the
the regulator.
label and indicate the new spring range.
Types 67C, 67CR, 67CS, and 67CSR 5. Stack the control spring (key 17) and upper spring
seat (key 20) onto the diaphragm assembly (key 16).
Trim Maintenance
6. Install the spring case (key 7) on the body
Key numbers are referenced in Figures 3, 4, and 12. (key 1) with the vent oriented to prevent clogging
or entrance of moisture. Install the six spring case
1. Remove four bottom plate screws (key 3) from the
screws (key 3) using a crisscross pattern and torque
bottom plate (key 39) and separate the bottom
to 15 to 30-inch-pounds / 1.7 to 3.4 N•m.
plate and O-ring (key 4) from the body (key 1).
2. Inspect the removed parts for damage and debris. Note
Replace any damaged parts. On Types 67CS and 67CSR, lubricate
3. To remove the valve cartridge assembly, grasp the adjusting screw (key 18) thread to
the end of cartridge (key 10) and pull it straight reduce galling of the stainless steel.
out of body (key 1). Replace with new cartridge 7. When all maintenance is complete, refer to the
assembly. The cartridge assembly may be Startup and Adjustment section to put the regulator
disassembled and parts may be cleaned or back into operation and adjust the pressure
replaced. If the soft seat (key 15) was removed, setting. Tighten the locknut (key 19) if used, and
make sure it is properly snapped into place before install the closing cap (key 33) if used.
installing the valve cartridge assembly.
4. Check O-ring (key 14) for wear and replace, if Types 67CF, 67CFR, 67CFS, and 67CFSR
necessary. Apply lubricant to the O-ring and place
in the body. Align cartridge key to keyway in body Filter Element and Trim Maintenance
and insert. Reinstall the O-ring (key 4), secure
Key numbers are referenced in Figures 5, 6, and 12.
the bottom plate (key 39) with screws (key 3), and
torque to 15 to 30-inch-pounds / 1.7 to 3.4 N•m. 1. Remove four dripwell screws (key 3) from the
dripwell (key 5) and separate the dripwell and
Diaphragm Maintenance O-ring (key 4) from the body (key 1). The filter
retainer (key 9), thrust washer (key 37), filter
Key numbers are referenced in Figures 3 and 4. element (key 6), and gasket (key 26) may come
1. Back out the adjusting screw or handwheel (key 18) off with dripwell. If not, remove these parts.
until compression is removed from the spring (key 17). 2. Inspect the removed parts for damage and debris.
2. Remove the spring case screws (key 3) to separate Replace any damaged parts. If a replacement is
the spring case (key 7) from the body (key 1). not available, the filter element may be cleaned.
Remove the upper spring seat (key 20) and spring 3. To remove the valve cartridge assembly, grasp
(key 17). the end of cartridge and pull it straight out of body
3. Remove the diaphragm assembly (key 16), (key 1). Replace with new cartridge assembly.
inspect the diaphragm, and replace the The cartridge assembly may be disassembled and
assembly, if necessary. parts may be cleaned or replaced. If the soft seat
(key 15) was removed, make sure it is properly
4. Place the diaphragm assembly (key 16) on the snapped into place before installing the valve
body (key 1) as shown in Figure 3 or 4. Push cartridge assembly.
down on the diaphragm assembly to make sure
the valve plug (key 11) strokes smoothly and 4. Check O-ring (key 14) for wear and replace, if
approximately 1/16 inch / 1.6 mm. necessary. Apply lubricant to the O-ring (key 14),
then align cartridge key to keyway in body and
insert. Reinstall the gasket (key 26), filter element
(key 6), thrust washer (key 37), and filter retainer

6
67C Series
(key 9). Reinstall the O-ring (key 4), secure the Parts Ordering
dripwell with screws (key 3), and torque to 15 to
30-inch-pounds / 1.7 to 3.4 N•m. When corresponding with the local Sales Office about
this regulator, include the type number and all other
Diaphragm Maintenance pertinent information printed on the label. Specify
the eleven-character part number when ordering new
Key numbers are referenced in Figures 5 and 6. parts from the following parts list.
1. Back out the adjusting screw or handwheel
(key 18) until compression is removed from the Parts List
spring (key 17). Key Description Part Number

2. Remove the six spring case screws (key 3) to Parts Kits


separate the spring case (key 7) from the body Types 67C, 67CR, 67CS, and 67CSR
(key 1). Remove the upper spring seat (key 20)   Includes valve cartridge assembly (contains
   keys 10, 11, 12, 13, 14, and 15),
and spring (key 17).   O-ring (key 4), diaphragm assembly (key 16),
   and four screws (key 3)
3. Remove the diaphragm assembly (key 16), inspect Type 67C (without relief)
the diaphragm, and replace the assembly, Brass stem with Nitrile (NBR) plug R67CX000012
Aluminum stem with Nitrile (NBR) plug (NACE) R67CX000N12
if necessary. Type 67CR (with relief)
Brass stem with Nitrile (NBR) plug R67CRX00012
4. Place the diaphragm assembly (key 16) on the Aluminum stem with Nitrile (NBR) plug (NACE) R67CRX00N12
body (key 1) as shown in Figure 5. Push down on Type 67CS (without relief)
the diaphragm assembly to make sure the valve Stainless steel stem with Nitrile (NBR)
plug (NACE) R67CSX00012
plug (key 11) strokes smoothly and approximately Type 67CSR (with relief)
1/16 inch / 1.6 mm. Stainless steel stem with Nitrile (NBR)
  plug (NACE) R67CSRX0012
Note Types 67CF, 67CFR, and 67CFSR
  Includes valve cartridge assembly (contains
In step 5, if installing a control spring of    keys 10, 11, 12, 13, 14, and 15), diaphragm
    assembly (key 16), O-ring (key 4),
a different range, be sure to delete the      filter element (key 6), filter gasket (key 26),
spring range originally appearing on the       thrust washer (key 37), and four screws (key 3)
label and indicate the new spring range. Type 67CF (without relief)
Brass stem with Nitrile (NBR) plug R67CFX00012
Aluminum stem with Nitrile (NBR) plug (NACE) R67CFX00N12
5. Stack the control spring (key 17) and upper Type 67CFR (with relief)
spring seat (key 20) onto the diaphragm Brass stem with Nitrile (NBR) plug R67CFRX0012
assembly (key 16). Aluminum stem with Nitrile (NBR) plug (NACE) R67CFRX0N12
Type 67CFSR (with relief)
6. Install the spring case (key 7) on the body (key 1) Stainless steel stem with Nitrile (NBR)
  plug (NACE) R67CFSRX012
with the vent oriented to prevent clogging or
Valve Cartridge Assembly Only(1)*
entrance of moisture. Install the six spring case Type 67C, 67CR, 67CF, or 67CFR
screws (key 3) using a crisscross pattern and Brass stem with Nitrile (NBR) plug
with Nitrile (NBR) O-ring T14121T0012
torque to 15 to 30-inch-pounds / 1.7 to 3.4 N•m.
with Silicone (VMQ) O-ring T14121T0032
Aluminum stem
Note with Fluorocarbon (FKM) plug T14121T0022
with Nitrile (NBR) plug T14121T0042
On Types 67CFS and 67CFSR, lubricate Aluminum stem (NACE)
with Nitrile (NBR) plug T14121T0052
the adjusting screw (key 18) thread to with Fluorocarbon (FKM) plug T14121T0062
reduce galling of stainless steel. Stainless steel stem
with Nitrile (NBR) plug T14121T0072
7. When all maintenance is complete, refer to the Type 67CS, 67CSR, 67CFS, or 67CFSR
Startup and Adjustment section to put the regulator 316 Stainless steel stem
with Nitrile (NBR) plug and O-rings (NACE) T14121T0092
back into operation and adjust the pressure with Fluorocarbon (FKM) plug and O-rings T14121T0102
setting. Tighten the locknut (key 19) if used, and with Nitrile (NBR) plug and
install the closing cap (key 33) if used.   Silicone (VMQ) O-rings T14121T0112

1. Valve cartridge assembly includes keys 10, 11, 12, 13, 14, and 15.
*Recommended Spare Part.

7
67C Series
Key Description Part Number
18
Automatic Drain Conversion Kits
  Types 67CF, 67CFR, 67CFS, and 67CFSR 19
7A
   Includes auto-drain (key 2), four flange L2 NOTE:
7B NOTE:11
    screws (key 3), dripwell O-ring (key 4),
    and dripwell (key 5). 17
20
   Note: Temperature rating is 40 to 175°F / 4 to 79°C.
16D
   Types 67CF and 67CFR
16B
    Nitrile (NBR) R67ADNX0012 16E
    Fluorocarbon (FKM) R67ADFX0012 16C
15 to
3 15 - 30 in lbs.
   Types 67CFS and 67CFSR 30 inch-pounds /
    Nitrile (NBR) R67ADNX0022 16A 1.7 to 3.4 N•m
    Fluorocarbon (FKM) R67ADFX0022
15
1 Body
Type 67C or 67CR, Aluminum T40643T0RG2 11
Type 67CS or 67CSR, CF3M/CF8M
Stainless Steel GE00909X012
Type 67CF or 67CFR, Aluminum T80510T0012 INLET OUTLET

Type 67CFS or 67CFSR, CF3M/CF8M


Stainless steel 40C1887X012 14 L1
1
Type 67CFR with Smart Bleed™, Aluminum GE03477X012 12
2 Drain Valve L1 4
Manual Type 67CF or 67CFR 10
Brass 1K418918992
18-8 Stainless steel AH3946X0012 13
Type 67CFS or 67CFSR
316 Stainless steel AH3946X0032 15-to
3 15 3030ininch
lbs. pounds /
18-8 Stainless steel AH3946X0012 1.7 to 3.4 N•m
39
Automatic (only used with large capacity dripwell) T40645

Type 67CFS or 67CFSR


APPLY LUBRICANT (L)
Nitrile (NBR) GG00554X012 L1 = MULTI-PURPOSE POLYTETRAFLUOROETHYLENE (PTFE) LUBRICANT
      Fluorocarbon (FKM) GG00554X022 L2 = ANTI-SEIZE COMPOUND
3 Flange Screw
Type 67C, 67CR, 67CF, or 67CFR
Figure 3. Type 67C or 67CR Assembly
Standard spring case and spring case Key Description Part Number
  with 1/4 NPT vent (10 required) T13526T0012
For wire seal
7 Spring Case Assembly
Zinc-plated steel (9 required) T13526T0012
Type 67C, 67CR, 67CF, or 67CFR, Aluminum/Steel
Steel (with hole) (1 required) 14B3987X012
Drilled hole vent (standard) T14070T0012
Type 67CS, 67CSR, 67CFS, or
Single hole vent T14070T0022
67CFSR (10 required) T13526T0042
Type 67CS, 67CSR, 67CFS, or 67CFSR,
4* O-ring   CF3M/CF8M Stainless steel 20C1727X012
Type 67C, 67CR, 67CS, or 67CSR
9 Filter Retainer
Nitrile (NBR) T14380T0012
Type 67CF or 67CFR, Zinc-plated T14052T0012
Fluorocarbon (FKM) T14380T0022
Type 67CFS or 67CFSR, 316 Stainless steel T14052T0022
Silicone (VMQ) T14380T0032
Type 67CF, 67CFR, 67CFS, or 67CFSR 10*(1) Valve Cartridge T80434T0012
Nitrile (NBR) T14057T0042 11*(1) Valve Plug
Fluorocarbon (FKM) T14057T0022 Type 67C, 67CR, 67CF, or 67CFR
Silicone (VMQ) T14057T0032 Brass stem, Nitrile (NBR) plug T14053T0012
5 Dripwell Aluminum stem, Fluorocarbon (FKM) plug T14053T0022
Type 67CF or 67CFR, Aluminum Aluminum stem, Nitrile (NBR) plug T14053T0032
Standard T21040T0012 Type 67CS, 67CSR, 67CFS, or 67CFSR
Large Capacity, manual drain GE34605X012 Stainless steel stem, Nitrile (NBR) plug T14053T0042
Large Capacity, automatic drain GE34606X012 Stainless steel stem, Fluorocarbon (FKM) plug T14053T0052
Type 67CFS or 67CFSR, 12*(1) Valve Spring
  CF3M/CF8M Stainless Steel Type 67C, 67CR, 67CF, or 67CFR
  Standard 20C1726X012 302 Stainless steel T14105T0012
   Large Capacity, manual drain GE34607X012 Inconel® (NACE) T14116T0012
   Large Capacity, automatic drain GE31792X012 Type 67CS, 67CSR, 67CFS, or 67CFSR,
6* Filter Element Inconel® (NACE) T14116T0012
(Types 67CF, 67CFR, 67CFS, and 67CFSR)
Polyethylene (5 microns) (standard) GE32761X012 13*(1) Valve Retainer, Rynite® T14071T0012
Glass fiber (5 microns) 17A1457X012 14*(1) O-ring
Polyvinylidene fluoride (PVDF) (40 microns) GE32762X012 Nitrile (NBR) T14063T0012
316 Stainless steel (40 microns) 15A5967X022 Fluorocarbon (FKM) T14063T0022
Silicone (VMQ) T14063T0032
*Recommended Spare Part.
1. Valve cartridge assembly includes keys 10, 11, 12, 13, 14, and 15. 15*(1) Soft Seat
Inconel® is a marked own by Special Metals Corporation Nitrile (NBR) T14055T0012
Rynite® is a marked owned by E.I. du Pont de Nemours and Co. Fluorocarbon (FKM) T14055T0022

8
67C Series

L2
18
31
19
33
L2 17
L2 18 20
17
20
15 10
45 3 1 26
7
16 6
11 15 4
1
L1
10 14 3
L1 14
12 9
L1 4 11
39 13 5
12 2 37 13
GE03521 T40580
APPLY LUBRICANT (L)
APPLY LUBRICANT (L)
L1 = MULTI-PURPOSE POLYTETRAFLUOROETHYLENE (PTFE) LUBRICANT
L1 = MULTI-PURPOSE POLYTETRAFLUOROETHYLENE (PTFE) LUBRICANT
L2 = ANTI-SEIZE COMPOUND
L2 = ANTI-SEIZE COMPOUND

Figure 4. Type 67CS or 67CSR Assembly Figure 5. Type 67CF or 67CFR Assembly

Key Description Part Number Key Description Part Number

16* Diaphragm Assembly 17 Spring (continued)


Type 67C or 67CF (without relief) Type 67CR or 67CFR (NACE), Inconel® (NACE)
Nitrile (NBR) T14119T0022 0 to 35 psig / 0 to 2.4 bar, Silver stripe T14113T0012
Fluorocarbon (FKM) T14119T0042 0 to 60 psig / 0 to 4.1 bar, Blue T14114T0012
Type 67CR or 67CFR (with relief) 0 to 125 psig / 0 to 8.6 bar, Red T14115T0012
Nitrile (NBR) T14119T0012 Type 67CS, 67CSR, 67CFS or
Fluorocarbon (FKM) T14119T0032   67CFSR, Inconel® (NACE)
Silicone (VMQ) T14119T0052   0 to 20 psig / 0 to 1.3 bar, Green 10C1729X012
Type 67CS or 67CFS (without relief)   0 to 35 psig / 0 to 2.4 bar, Silver stripe T14113T0012
Nitrile (NBR) T14119T0062   0 to 60 psig / 0 to 4.1 bar, Blue T14114T0012
Fluorocarbon (FKM) T14119T0072   0 to 125 psig / 0 to 8.6 bar, Red T14115T0012
Type 67CSR or 67CFSR (with relief)   0 to 150 psig / 0 to 10.3 bar, Black 10C1730X012
Nitrile (NBR) T14119T0082 18 Adjusting Screw
Fluorocarbon (FKM) T14119T0092 Type 67C, 67CR, 67CF, or 67CFR,
Silicone (VMQ) T14119T0102   Zinc-plated steel
17 Spring   For standard spring case
Type 67C, 67CR, 67CF, or 67CFR, Square head (standard) T14061T0012
Plated steel (standard) Handwheel T14102T0012
0 to 20 psig / 0 to 1.4 bar, Green stripe GE07809T012 Wire seal (not shown) T14104T0012
0 to 35 psig / 0 to 2.4 bar, Silver T14059T0012 For spring case with 1/4 NPT vent,
   0 to 60 psig / 0 to 4.1 bar, Blue stripe T14058T0012 Zinc-plated steel
   0 to 125 psig / 0 to 8.6 bar, Red stripe T14060T0012   Square head for closing cap, T14101T0012
Handwheel T14103T0012
Wire seal (not shown) T14198T0012
*Recommended Spare Part.
Inconel® is a marked own by Special Metals Corporation

9
67C Series

33 19

L2 18 L2 18
33 19
16 20 31
18 18
17
16 45 20 15 31

10 17 7

45 1 15 11

10 26 7 14 L1
40C1728

L1 4
12
1 6 11 Figure 7. 67C Series Optional Panel Mount

13
26 5 14
9 37
4
12
6 40C1728 2
13
APPLY LUBRICANT (L)
L1 = MULTI-PURPOSE POLYTETRAFLUOROETHYLENE (PTFE) LUBRICANT

5 L2 = ANTI-SEIZE COMPOUND

Figure 6. Type 67CFS or 67CFSR Assembly

37
GAUGE

9 VENT POSITION 2
DRAIN VALVE
POSITION 4

2 3
DRAIN VALVE
POSITION 1
VENT POSITION 1 DRAIN VALVE
VENT POSITION 3 (STANDARD)
(STANDARD) POSITION 3

INLET OUTLET
INLET OUTLET

3
GAUGE

B2699_C VENT POSITION 4 DRAIN VALVE


B2699_D POSITION 2

Figure 9. Types 67CF, 67CFR, 67CFS, and 67CFSR


Figure 8. 67C Series Spring Case Vent Positions Drain Valve Positions

10
67C Series

33
PUSHER POST
(WITHOUT RELIEF)

LOWER SPRING
SEAT
RETAINING RING
DIAPHRAGM
PLATE

DIAPHRAGM PUSHER POST


(WITH RELIEF)
B2696 B2698

Figure 10. Diaphragm Assembly (Key 16)


Figure 11. Optional Closing Cap
[Only Available with the 1/4-inch / 6.4 mm Spring Case Vent]

SOFT SEAT 0.18 /


(KEY 15) 4.6

0.50 /
OD 0.32 /
13 ID
8.1

inches /
mm

VALVE PLUG VALVE CARTRIDGE


(KEY 10) SPACER OUTER DIAMETER SPACER WIDTH AND
(KEY 11) INNER DIAMETER

O-RING
(KEY 14)

VALVE SPRING
34
(KEY 12)

IN

VALVE RETAINER SPACER


(KEY 13)

B2695
B2697

Figure 12. Valve Cartridge Assembly Figure 13. Spacer Diameter and Assembly
(For Installing in an Existing Installation
if the Mounting Bolts are too Long)

11
67C Series
Key Description Part Number Key Description Part Number

18 Adjusting Screw (continued) 26* Filter Gasket


Type 67CS, 67CSR, 67CFS, or 67CFSR Type 67CF, 67CFR, 67CFS, or 67CFSR
Square head with or without closing cap,   with Nitrile (NBR) O-ring T14081T0012
  316 Stainless steel T14101T0022   with Fluorocarbon (FKM) O-ring T14081T0022
Handwheel, Zinc-plated steel T14103T0012 30 NACE Tag (not shown), 18-8 Stainless steel 19A6034X012
19 Locknut 31 Panel Mounting Nut, 303 Stainless steel 10B2657X012
Type 67C, 67CR, 67CF, or 67CFR
32 Wire Seal (not shown)
Zinc-plated steel 1A946324122
Type 67C or 67CR
316 Stainless steel 1A9463X0042
304 Stainless steel 1U7581000A2
Type 67CS, 67CSR, 67CFS, or 67CFSR
316 Stainless steel 1A9463X0042 33 Closing Cap, Resin 23B9152X012
20 Upper Spring Seat 34 Spacer (2 required) (Figure 13)
Type 67C, or 67CR only Type 67CF or 67CFR, Steel T14123T0012
1/4 NPT Vent T14051T0042 Type 67CFS or 67CFSR, 18-8 Stainless steel T14123T0022
Type 67C, 67CR, 67CF, or 67CFR 37* Thrust Washer
Standard T14051T0012 (Type 67CF, 67CFR, 67CFS, or 67CFSR)
22 Pressure Gauge (not shown)   with Nitrile (NBR) O-rings T14196T0012
Type 67C, 67CR, 67CF, or 67CFR, Brass   with Fluorocarbon (FKM) O-rings T14196T0022
0 to 30 psig/0 to 2.1 bar/0 to 0.2 MPa 11B8579X022 39 Bottom Plate, 316 Stainless steel
0 to 60 psig/0 to 4.1 bar/0 to 0.4 MPa 11B8579X032 Type 67C or 67CR GE03520XRG2
0 to 160 psig/0 to 11.0 bar/0 to 1.1 MPa 11B8579X042 Type 67CS or 67CSR GE03520X012
For all types, Stainless Steel 45 Screen Vent, 18-8 Stainless steel
0 to 30 psig/0 to 2.1 bar/0 to 0.2 MPa 11B9639X012 Type 67CS, 67CSR, 67CFS, or 67CFSR 0L078343062
0 to 60 psig/0 to 4.1 bar/0 to 0.4 MPa 11B9639X022
0 to 160 psig/0 to 11.0 bar/0 to 1.1 MPa 11B9639X032
23 1/4-inch / 6.4 mm Pipe Plug (not shown) Parts for Mounting on
Type 67C, 67CR, 67CF, or 67CFR Fisher® 2500 Series Controller
Socket head, Steel 1C333528992
For all types (Type 67CF or 67CFR)
Hex head, Stainless steel 1A767535072
Key Description Part Number
24 Tire Valve (not shown)
Type 67C, 67CR, 67CF, or 67CFR 1H447099022
35      Mounting adaptor plate, Steel (not shown) T21043T0012
36      O-ring, Nitrile (NBR) (not shown) 1E591406992
*Recommended Spare Part.
38      Gasket, Neoprene (CR) (not shown) 1C898603012

Industrial Regulators Natural Gas Technologies TESCOM

Emerson Process Management Emerson Process Management Emerson Process Management


Regulator Technologies, Inc. Regulator Technologies, Inc. Tescom Corporation
USA - Headquarters USA - Headquarters USA - Headquarters
McKinney, Texas 75069-1872, USA McKinney, Texas 75069-1872, USA Elk River, Minnesota 55330-2445, USA
Tel: +1 800 558 5853 Tel: +1 800 558 5853 Tels: +1 763 241 3238
Outside U.S. +1 972 548 3574 Outside U.S. +1 972 548 3574     +1 800 447 1250
Asia-Pacific Asia-Pacific Europe
Shanghai 201206, China Singapore 128461, Singapore Selmsdorf 23923, Germany
Tel: +86 21 2892 9000 Tel: +65 6770 8337 Tel: +49 38823 31 287
Europe Europe Asia-Pacific
Bologna 40013, Italy Bologna 40013, Italy Shanghai 201206, China
Tel: +39 051 419 0611 Tel: +39 051 419 0611 Tel: +86 21 2892 9499
Gallardon 28320, France
Middle East and Africa Tel: +33 2 37 33 47 00
Dubai, United Arab Emirates
Tel: +971 4811 8100

For further information visit www.fisherregulators.com

The Emerson logo is a trademark and service mark of Emerson Electric Co. All other marks are the property of their prospective owners. Fisher is a mark owned by Fisher Controls International LLC,
a business of Emerson Process Management.
The contents of this publication are presented for informational purposes only, and while every effort has been made to ensure their accuracy, they are not to be construed as warranties or
guarantees, express or implied, regarding the products or services described herein or their use or applicability. We reserve the right to modify or improve the designs or specifications of such
products at any time without notice.
Emerson Process Management does not assume responsibility for the selection, use or maintenance of any product. Responsibility for proper selection, use and maintenance of any Emerson
Process Management product remains solely with the purchaser.

©Emerson Process Management Regulator Technologies, Inc., 2003, 2012; All Rights Reserved

You might also like