W7412 W8438
Introduction
Scope of the Manual • The Types 67CF and 67CFS are equipped with a
filter for removing particles from the supply gas.
This manual provides instructions and parts lists for
67C Series instrument supply regulators. Instructions • The Types 67CR and 67CSR have an internal
and parts lists for other equipment mentioned in this relief valve with a soft seat for reliable shutoff with
instruction manual, as well as for other 67 Series no discernible leakage.
regulators, are found in separate manuals. • The Types 67CFR and 67CFSR have a filter and
internal relief valve with a soft seat for reliable
Product Descriptions shutoff with no discernible leakage.
www.fisherregulators.com
67C Series
Specifications
The Specifications section gives some general specifications for the 67C Series regulator. A label on the spring
case gives the control spring range for a given regulator as it comes from the factory.
Body Size, Inlet and Outlet Connection Style With Fluorocarbon (FKM):
1/4 NPT Polyethylene Filter(5) (Standard):
Maximum Inlet Pressure (Body Rating)(1) 0 to 180°F / -18 to 82°C
All except Types 67CS and 67CSR: Polyvinylidene (PVDF), SST, or Glass Filter (Optional):
0 to 300°F / -18 to 149°C
250 psig / 17.2 bar
Types 67CS and 67CSR: 400 psig / 27.6 bar With Silicone (VMQ)(3) Diaphragm and Low
Temperature bolting: -60 to 180°F / -51 to 82°C
Outlet Pressure Ranges With Gauges: -40 to 180°F / -40 to 82°C
See Table 1
Smart Bleed™ Check Valve Setpoint
Maximum Emergency Outlet Pressure(1) 6 psi / 0.41 bar differential
50 psi / 3.4 bar over outlet pressure setting
Types 67CF, 67CFR, 67CFS, and 67CFSR
Wide-Open Flow Coefficients Filter Capabilities
Main Valve: Cg: 11.7; Cv: 0.36; C1: 32.2 Free Area: 12 times pipe area
Internal Relief Valve: Cg: 1.45; Cv: 0.045; C1: 32.8 Micron Rating:
Polyethylene Filter(5) (Standard): 5 microns
IEC Sizing Coefficients Glass Fiber Filter (Optional): 5 microns
Main Valve: XT: 0.66; FL: 0.89; FD: 0.50 PVDF or Stainless Steel Filter (Optional):
Accuracy 40 microns
Inlet Sensitivity: Less than 0.2 psig / 14 mbar Drain Valve and Spring Case Vent Location
change in outlet pressure for every 25 psig / Aligned with inlet standard, other positions optional
1.7 bar change in inlet pressure
Repeatability: 0.1 psig / 7 mbar(2) Pressure Registration
Air Consumption: Testing repeatedly shows Internal
no discernible leakage
Options
Types 67CR, 67CSR, 67CFR, and 67CFSR All Types
Internal Relief Performance • Handwheel adjusting screw
Low capacity for minor seat leakage only; other • Inlet screen
overpressure protection must be provided if inlet • NACE MR0175 or NACE MR0103 construction(4)
pressure can exceed the maximum pressure rating • Panel mount (includes spring case with 1/4 NPT
of downstream equipment or exceeds maximum vent, handwheel, and panel mounting nut)
outlet pressure rating of the regulator. • Closing cap (available on spring case with
1/4 NPT vent)
Approximate Weights • Fluorocarbon (FKM) elastomers for high
Types 67C, 67CR, 67CF, and 67CFR: temperatures and/or corrosive chemicals
1 pound / 0.5 kg • Silicone (VMQ) elastomers for cold temperatures
Types 67CS and 67CSR: • Fixed Bleed Restriction
2.5 pounds / 1 kg • Triple scale outlet pressure gauge (brass or
Types 67CFS and 67CFSR: stainless steel)
4 pounds / 2 kg • Stainless steel stem on the valve plug
• Tire valve or pipe plug in second outlet
Temperature Capabilities(1) Types 67CFR and 67CFSR only
With Nitrile (NBR) • Smart BleedTM internal check valve
Standard Bolting: -20 to 180°F / -29 to 82°C • Large dripwell with manual or automatic drain
Stainless Steel Bolting: -40 to 180°F / -40 to 82°C Types 67CF and 67CFR only
• Stainless steel drain valve
1. The pressure/temperature limits in this Instruction Manual and any applicable standard or code limitation should not be exceeded.
2. Repeatability is the measure of the regulator’s ability to return to setpoint consistently when traveling from steady state to transient to steady state.
3. Silicone (VMQ) is not compatible with hydrocarbon gas.
4. Product complies with the material requirements of NACE MR0175. Environmental limits may apply.
5. Do not use in high aromatic hydrocarbon service.
2
Month Year
W8442
INLET PRESSURE
INLET PRESSURE
OUTLET PRESSURE
OUTLET PRESSURE W7433
SMART BLEED™ OPTION
ATMOSPHERIC PRESSURE
ATMOSPHERIC PRESSURE TYPE 67CFR OR 67CFSR TYPES 67CFR AND 67CFSR
LOADING PRESSURE
INTERMEDIATE PRESSURE Figure 2. 67C Series Operational Schematics
PILOT SUPPLY PRESSURE
Internal VACUUM
Relief PRESSURE
(Types 67CR, 67CSR, downstream of the regulator, thereby conserving
TANK PRESSURE plant air.
67CFR, andPRESSURE
VAPOR 67CFSR)
INLET PRESSURE
OUTLET PRESSURE
If for some reason, outside of normal
ATMOSPHERIC operating
PRESSURE Note
LOADING PRESSURE
conditions, the downstream pressure exceeds the
INTERMEDIATE During normal operation the check
setpoint of the regulator, the forcePRESSURE
created by the
PILOTwill
SUPPLY valve’s metal to metal seat allows
downstream pressure lift thePRESSURE
diaphragm until the
limited flow through the regulator from
diaphragm is lifted off the relief seat. This allows flow
the inlet to outlet, even when there is
through the token relief. The relief valve on the
no downstream demand. To prevent
Type 67CR, 67CSR, 67CFR, or 67CFSR is an
downstream pressure buildup, the Smart
elastomer plug that prevents leakage of air from the
Bleed option is only available with the
downstream to atmosphere during normal operation,
internal relief version of the 67 Series.
thereby conserving plant air.
3
67C Series
Table 1. Outlet Pressure Ranges and Control Spring Data
CONTROL SPRING DATA
OUTLET PRESSURE RANGES
TYPES Wire Diameter Free Length
Color Material Part Number
psig bar Inch mm Inch mm
0 to 20 0 to 1.4 Green stripe GE07809T012 0.135 3.43 1.43 36.2
0 to 35 0 to 2.4 Silver Music T14059T0012 0.156 3.96 1.43 36.2
0 to 60 0 to 4.1 Blue stripe Wire T14058T0012 0.170 4.32 1.43 36.2
67C, 67CR, 0 to 125 0 to 8.6 Red stripe T14060T0012 0.207 5.26 1.43 36.2
67CF, and 67CFR
0 to 35 0 to 2.4 Silver stripe T14113T0012 0.156 3.96 1.43 36.2
0 to 60 0 to 4.1 Blue Inconel® T14114T0012 0.172 4.37 1.43 36.2
0 to 125 0 to 8.6 Red T14115T0012 0.207 5.26 1.43 36.2
0 to 20 0 to 1.3 Green 10C1729X012 0.135 3.43 1.50 38.1
0 to 35 0 to 2.4 Silver stripe T14113T0012 0.156 3.96 1.43 36.2
67CS, 67CSR,
0 to 60 0 to 4.1 Blue Inconel® T14114T0012 0.172 4.37 1.43 36.2
67CFS, and 67CFSR
0 to 125 0 to 8.6 Red T14115T0012 0.207 5.26 1.43 36.2
0 to 150 0 to 10.3 Black 10C1730X012 0.250 6.35 1.77 44.9
Inconel® is a marked own by Special Metals Corporation
4
67C Series
chemicals, or other foreign material) orient the vent or explosion of accumulated gas, never
to the lowest possible point on the spring case or adjust the control spring to produce an
otherwise protect it. outlet pressure higher than the upper
limit of the outlet pressure range for that
Inspect the vent hole regularly to make sure it is particular spring. If the desired outlet
not plugged. Spring case vent hole orientation pressure is not within the range of the
may be changed by rotating the spring case with control spring, install a spring of the
respect to the body. A 1/4 NPT spring case vent proper range according to the diaphragm
may be remotely vented by installing obstruction- parts maintenance procedure.
free tubing or piping into the vent. Protect the
remote vent by installing a screened vent cap on 2. If outlet pressure adjustment is necessary, monitor
the remote end of the vent pipe. outlet pressure with a gauge during the adjustment
procedure. The regulator is adjusted by loosening
6. For use in regulator shutdown, install upstream the locknut (key 18), if used, and turning the
block and vent valves and downstream block and adjusting screw or handwheel (key 19) clockwise to
vent valves (if required), or provide some other increase or counterclockwise to decrease the outlet
suitable means of properly venting the regulator pressure setting. Retighten the locknut to maintain
inlet and outlet pressures. Install a pressure gauge the adjustment position.
to monitor instruments on startup.
7. Apply a good grade of pipe compound to the external Shutdown
pipe threads before making connections, making sure
not to get the pipe compound inside the regulator. First, close the nearest upstream block valve and
then close the nearest downstream block valve
8. Install tubing fitting or piping into the 1/4 NPT (when used). Next, open the downstream vent valve.
inlet connection on the body (key 1) and into the Since the regulator remains open in response to the
1/4 NPT body outlet connection. decreasing downstream pressure, pressure between
the closed block valves will be released through the
9. The second 1/4 NPT outlet can be used for a gauge
open vent valve.
or other use. If not used, it must be plugged.
5
67C Series
not attempt any maintenance or Note
disassembly without first isolating the
In step 5, if installing a control spring of
regulator from system pressure and
a different range, be sure to delete the
relieving all internal pressure from
spring range originally appearing on the
the regulator.
label and indicate the new spring range.
Types 67C, 67CR, 67CS, and 67CSR 5. Stack the control spring (key 17) and upper spring
seat (key 20) onto the diaphragm assembly (key 16).
Trim Maintenance
6. Install the spring case (key 7) on the body
Key numbers are referenced in Figures 3, 4, and 12. (key 1) with the vent oriented to prevent clogging
or entrance of moisture. Install the six spring case
1. Remove four bottom plate screws (key 3) from the
screws (key 3) using a crisscross pattern and torque
bottom plate (key 39) and separate the bottom
to 15 to 30-inch-pounds / 1.7 to 3.4 N•m.
plate and O-ring (key 4) from the body (key 1).
2. Inspect the removed parts for damage and debris. Note
Replace any damaged parts. On Types 67CS and 67CSR, lubricate
3. To remove the valve cartridge assembly, grasp the adjusting screw (key 18) thread to
the end of cartridge (key 10) and pull it straight reduce galling of the stainless steel.
out of body (key 1). Replace with new cartridge 7. When all maintenance is complete, refer to the
assembly. The cartridge assembly may be Startup and Adjustment section to put the regulator
disassembled and parts may be cleaned or back into operation and adjust the pressure
replaced. If the soft seat (key 15) was removed, setting. Tighten the locknut (key 19) if used, and
make sure it is properly snapped into place before install the closing cap (key 33) if used.
installing the valve cartridge assembly.
4. Check O-ring (key 14) for wear and replace, if Types 67CF, 67CFR, 67CFS, and 67CFSR
necessary. Apply lubricant to the O-ring and place
in the body. Align cartridge key to keyway in body Filter Element and Trim Maintenance
and insert. Reinstall the O-ring (key 4), secure
Key numbers are referenced in Figures 5, 6, and 12.
the bottom plate (key 39) with screws (key 3), and
torque to 15 to 30-inch-pounds / 1.7 to 3.4 N•m. 1. Remove four dripwell screws (key 3) from the
dripwell (key 5) and separate the dripwell and
Diaphragm Maintenance O-ring (key 4) from the body (key 1). The filter
retainer (key 9), thrust washer (key 37), filter
Key numbers are referenced in Figures 3 and 4. element (key 6), and gasket (key 26) may come
1. Back out the adjusting screw or handwheel (key 18) off with dripwell. If not, remove these parts.
until compression is removed from the spring (key 17). 2. Inspect the removed parts for damage and debris.
2. Remove the spring case screws (key 3) to separate Replace any damaged parts. If a replacement is
the spring case (key 7) from the body (key 1). not available, the filter element may be cleaned.
Remove the upper spring seat (key 20) and spring 3. To remove the valve cartridge assembly, grasp
(key 17). the end of cartridge and pull it straight out of body
3. Remove the diaphragm assembly (key 16), (key 1). Replace with new cartridge assembly.
inspect the diaphragm, and replace the The cartridge assembly may be disassembled and
assembly, if necessary. parts may be cleaned or replaced. If the soft seat
(key 15) was removed, make sure it is properly
4. Place the diaphragm assembly (key 16) on the snapped into place before installing the valve
body (key 1) as shown in Figure 3 or 4. Push cartridge assembly.
down on the diaphragm assembly to make sure
the valve plug (key 11) strokes smoothly and 4. Check O-ring (key 14) for wear and replace, if
approximately 1/16 inch / 1.6 mm. necessary. Apply lubricant to the O-ring (key 14),
then align cartridge key to keyway in body and
insert. Reinstall the gasket (key 26), filter element
(key 6), thrust washer (key 37), and filter retainer
6
67C Series
(key 9). Reinstall the O-ring (key 4), secure the Parts Ordering
dripwell with screws (key 3), and torque to 15 to
30-inch-pounds / 1.7 to 3.4 N•m. When corresponding with the local Sales Office about
this regulator, include the type number and all other
Diaphragm Maintenance pertinent information printed on the label. Specify
the eleven-character part number when ordering new
Key numbers are referenced in Figures 5 and 6. parts from the following parts list.
1. Back out the adjusting screw or handwheel
(key 18) until compression is removed from the Parts List
spring (key 17). Key Description Part Number
1. Valve cartridge assembly includes keys 10, 11, 12, 13, 14, and 15.
*Recommended Spare Part.
7
67C Series
Key Description Part Number
18
Automatic Drain Conversion Kits
Types 67CF, 67CFR, 67CFS, and 67CFSR 19
7A
Includes auto-drain (key 2), four flange L2 NOTE:
7B NOTE:11
screws (key 3), dripwell O-ring (key 4),
and dripwell (key 5). 17
20
Note: Temperature rating is 40 to 175°F / 4 to 79°C.
16D
Types 67CF and 67CFR
16B
Nitrile (NBR) R67ADNX0012 16E
Fluorocarbon (FKM) R67ADFX0012 16C
15 to
3 15 - 30 in lbs.
Types 67CFS and 67CFSR 30 inch-pounds /
Nitrile (NBR) R67ADNX0022 16A 1.7 to 3.4 N•m
Fluorocarbon (FKM) R67ADFX0022
15
1 Body
Type 67C or 67CR, Aluminum T40643T0RG2 11
Type 67CS or 67CSR, CF3M/CF8M
Stainless Steel GE00909X012
Type 67CF or 67CFR, Aluminum T80510T0012 INLET OUTLET
8
67C Series
L2
18
31
19
33
L2 17
L2 18 20
17
20
15 10
45 3 1 26
7
16 6
11 15 4
1
L1
10 14 3
L1 14
12 9
L1 4 11
39 13 5
12 2 37 13
GE03521 T40580
APPLY LUBRICANT (L)
APPLY LUBRICANT (L)
L1 = MULTI-PURPOSE POLYTETRAFLUOROETHYLENE (PTFE) LUBRICANT
L1 = MULTI-PURPOSE POLYTETRAFLUOROETHYLENE (PTFE) LUBRICANT
L2 = ANTI-SEIZE COMPOUND
L2 = ANTI-SEIZE COMPOUND
Figure 4. Type 67CS or 67CSR Assembly Figure 5. Type 67CF or 67CFR Assembly
9
67C Series
33 19
L2 18 L2 18
33 19
16 20 31
18 18
17
16 45 20 15 31
10 17 7
45 1 15 11
10 26 7 14 L1
40C1728
L1 4
12
1 6 11 Figure 7. 67C Series Optional Panel Mount
13
26 5 14
9 37
4
12
6 40C1728 2
13
APPLY LUBRICANT (L)
L1 = MULTI-PURPOSE POLYTETRAFLUOROETHYLENE (PTFE) LUBRICANT
5 L2 = ANTI-SEIZE COMPOUND
37
GAUGE
9 VENT POSITION 2
DRAIN VALVE
POSITION 4
2 3
DRAIN VALVE
POSITION 1
VENT POSITION 1 DRAIN VALVE
VENT POSITION 3 (STANDARD)
(STANDARD) POSITION 3
INLET OUTLET
INLET OUTLET
3
GAUGE
10
67C Series
33
PUSHER POST
(WITHOUT RELIEF)
LOWER SPRING
SEAT
RETAINING RING
DIAPHRAGM
PLATE
0.50 /
OD 0.32 /
13 ID
8.1
inches /
mm
O-RING
(KEY 14)
VALVE SPRING
34
(KEY 12)
IN
B2695
B2697
Figure 12. Valve Cartridge Assembly Figure 13. Spacer Diameter and Assembly
(For Installing in an Existing Installation
if the Mounting Bolts are too Long)
11
67C Series
Key Description Part Number Key Description Part Number
The Emerson logo is a trademark and service mark of Emerson Electric Co. All other marks are the property of their prospective owners. Fisher is a mark owned by Fisher Controls International LLC,
a business of Emerson Process Management.
The contents of this publication are presented for informational purposes only, and while every effort has been made to ensure their accuracy, they are not to be construed as warranties or
guarantees, express or implied, regarding the products or services described herein or their use or applicability. We reserve the right to modify or improve the designs or specifications of such
products at any time without notice.
Emerson Process Management does not assume responsibility for the selection, use or maintenance of any product. Responsibility for proper selection, use and maintenance of any Emerson
Process Management product remains solely with the purchaser.
©Emerson Process Management Regulator Technologies, Inc., 2003, 2012; All Rights Reserved