LM-Pro Datasheet - 20200618
LM-Pro Datasheet - 20200618
LM-Pro Datasheet - 20200618
LM-Pro Model 2
Typical Air Flow with 12 VDC Coil
LM-Pro Model 4*
Typical Air Flow with 12 VDC Coil
*During operation at 50psi, a flow shift of up to 5% over the life of the valve may occur.
3
LM-Pro Model 4*
Typical Low Flow Control with 12 VDC Coil
*During operation at 50psi, a flow shift of up to 5% over the life of the valve may occur.
4
Pneumatic Interface
INLET PORT
OUTLET PORT
.306 [7.77 mm]
Mechanical Integration
UNDERSTANDING THAT THE DOCUMENT AND THE INFORMATION IT CONTAINS WILL NOT BE COPIED OR
NOTES: DISCLOSED TO OTHERS EXCEPT WITH THE WRITTEN CONSENT OF PARKER, AND WILL NOT BE USED EXCEPT
PRECISION FLUIDICS DIVISION
HOLLIS, NH 03049
FOR THE DIRECT BENEFIT OF PARKER, AND WILL BE RETURNED AND ALL FURTHER USE DISCONTINUED UPON
REQUEST BY PARKER. C PARKER HANNIFIN CORPORATION 2003. ALL RIGHTS RESERVED.
VALVE CONNECTOR HOUSING:
1 INTERPRET PER ASME Y14.5M-1994 DRAWN DATE TITLE
JST #SM02B-PASS-TB OR EQUIVALENT
Dimensions
UNLESS OTHERWISE SPECIFIED DIMENSIONS MGM 1/23/2019
ARE IN INCHES. TOLERANCES ARE: CHECKED DATE
WIRE LEAD CONNECTOR: .XX : .010 [.254] ANGULAR : 1/2 J. VERRECCHIA 4/18/2019 OUTLINE DRAWING, LM-PRO
JST HOUSING #PAP-02V-S OR EQUIVALENT
JST CONTACTS #SPHD-002T-P0.5 OR EQUIVALENT .XXX : .005 [.127] FRACTIONAL : 1/64 ENG DATE
C. PRICE 4/18/2019
2
Parker Parker LM-Pro Basic Valve Dimensions
VALVE IS POLARITY SENSITIVE NOTE MARKINGS ON COVER
- DO NOT SCALE DRAWING -
MATERIAL:
MFG
M. BULISZAK
DATE
4/18/2019
SIZE CAT DWG NO SUFFIX REV
3. DIMENSION ARE FOR REFERENCE ONLY. THIRD ANGLE B 890 003552 001 A
PROJECTION
SCALE 02385000 SHEET 1 OF 1
2
1.438 [36.51 mm]
INLET PORT
.313 [7.94 mm]
.153 [3.89 mm]
2X .208 [5.28 mm]
.218 [5.52 mm]
(PORT ID)
UNITS
FILTERED PORT (OPTIONAL) IN [MM]
OUTLET PORT
.306 [7.77 mm]
Electrical Requirements
Table 1
Related Voltage Nominal Coil Resistance at 20°C Control Current at Maximum Flow
5 VDC 6Ω 555 mA
12 VDC 24 Ω 280 mA
Nominal Coil
Valve Drive Voltage Valve Coil Voltage,
Resistance @ 20°C
Input Current for R1 (Ohms) R2 (Ohms)
Input (VDC) Resulting (VDC) Full Flow (mA)
(Ohms)
Pressure
Flow Control Valve Relief Valve
Check
Parker LM-Pro Valve
Pressure
Sensor
To Atmosphere
Ordering Information
Sample Part ID 937 - 02 1 112 0 - 01 0
Description Series - Model Number Elastomer Voltage Body Material - Pneumatic Electric
Interface Interface
Options 937 - 02: 100psi/0.121 in (3.07 mm) 1: FKM 05: 5 VDC 0: Aluminum - 00: Manifold Mount 0: No Wire
04: 50 psi / 0.135 in (3.43 mm) Poppet and 12: 12 VDC No Inlet Filter Leads
Fluorosilicone 24: 24 VDC 01: Manifold Mount
Diaphragm with Filter
Accessories
290-006061-004: 12.5 in (317.5 mm) Wire Leads ** Not supplied with the valve
NOTE: In order to provide the best possible solution for your application, please provide the
following requirements when contacting Applications Engineering:
• Media, Inlet & Outlet Pressures
• Minimum Required Flow Rate
• System Supply Voltage
• Media & Ambient Temperature Range
To order online go to www.parker.com/precisionfluidics/LM-Pro. For more detailed information, visit us on
the Web, or call and refer to Parker LM-Pro Performance Spec. 790-002627-001.
Parker Hannifin Precision Fluidics Division reserves the right to make changes. Drawings are for reference only.