Product Data Sheet

P series | Pressurized PES UF Module

DuPont™ IntegraTec™ MB PRO 95


Modules for Open Platform

Key Features Key Applications


l Innovative Multibore™ PRO PES Fibers: l Municipal drinking water.
– Exceptional physical strength and chemical resistance. l Desalination RO pretreatment.
– High colloidal particulate, bacteria and virus log removal rate. l Ideal for large systems.
– Excellent filtration permeability.
– Optional coagulation can enhance the removal of algae and organics.
l Optimized Module Design:
– Open platform design to fit customer built skids.
– Enhanced active filtration area to minimize footprint.
– Robust materials for long lifetime.
– Easy installation and low maintenance.
– All wetted parts corrosion free.

Module Specification
General
Part Number IN-0122
Mode of Filtration In-Out Pressurized
Membrane Type Multibore™ PRO
Membrane Material PESm
Nominal Membrane Pore Size 0.02 μm
Module Operating Process Dead-end
Housing Material PVC-U, white
End Cap Material PVC-U, grey
End Cap Coupling Material SS (EPDM sealing)
Dimensions
Active Membrane Area 95 m² 1,023 ft²
Module Length (L) 1,720 ± 1.5 mm 67.7 inch
Distance Top / Bottom Feed Port (L1) 1,834 ± 3.0 mm 72.2 inch
Length with End Caps (L2) 1,914 ± 3.0 mm 75.4 inch
Module Diameter (A) 250 ± 1.5 mm 9.8 inch
Distance Feed Top Port - Filtrate Port (B) 190 ± 1.5 7.5 inch
Outer Diameter End Cap Coupling Maximum (C) 295 mm 11.6 inch
Protruding Part of the Port (E) 40 ± 1 mm 1.6 inch
Filtrate / Backwash Port (D) 50.8 mm 2 inch
Weight and Volume
Shipping Weight 58 kg 128 lbs.
Weight Empty 58 kg 128 lbs.
Weight Filled 110 kg 243 lbs. powered by
Hold-Up Volume Feed (CIP) 22 L 5.7 gal
Hold-Up Volume Membrane Structure (CIP) 18 L 4.8 gal
Hold-Up Volume Filtrate (CIP) 21 L 5.4 gal

Form No. 45-D04342-en, Rev. 0


Suggested Operating Conditions
General Details
Operating Temperature Range 1 - 40 °C 34 - 104 °F
Operating pH 3 - 11
Cleaning pH 1 - 13
Typical Filtration TMP 0.1 - 0.6 bar 1.5 - 8.7 psi
Typical Backwash TMP 0.3 - 2.0 bar 4.4 - 29.0 psi
Backwash Flux 230 L/(m²h) 135 gfd
Backwash Flow 21.8 m3h 96.0 gpm
Operating Limits (Maximum)
Rate of Temperature Change 5 °C/min 9 °F/min
Inlet Pressure (20 - 40 °C) 5 bar 73 psi
Rate of Pressure Change 0.5 bar/sec 7.3 psi/sec
Filtration TMP 1.5 bar 22 psi
Backwash TMP 3.0 bar 44 psi
Filtration Flux 140 L/(m2h) 82 gfd
Filtration Flow 13.3 m3h 58.6 gpm
Backwash Flux 250 L/(m²h) 147 gfd
Particle Size 230 μm
Exposure NaOCl ≤ 250,000 ppm x h (at pH ≥ 9.5)
Concentration NaOCl 500 ppm

General Information Regulatory Note


l Avoid any abrupt pressure variations during start-up, operation, l Certified drinking water modules require specific conditioning
shutdown, cleaning, or other sequences to prevent possible procedures prior to producing potable water. For operating
membrane damage. The maximum pressure change allowable parameters, please refer to the DuPont™ IntegraTec™
is 0.5 bar/s. Pressurized UF In-Out P Series Process and Design Guidelines
l For assembly please refer to the latest version of the DuPont™ (Form No. 45-D02234-en).
IntegraTec™ Pressurized UF In-Out P Series Modules for Open l Drinking water modules may be subjected to additional
Platforms Assembly Instructions (Form No. 45-D02231-en). regulatory restrictions in some countries. Please check local
l If operating limits and guidelines given in this bulletin are not regulatory guidelines and application status before use.
strictly followed, any warranty will be null and void. l Flushing needs to be done according to the DuPont™
l To control biological growth during extended system IntegraTec™ Pressurized UF In-Out Module Rinsing Procedure
shutdowns, a storage solution must be introduced into the (Form No. 45-D02947-en).
membrane modules. Detailed information is given in the
DuPont™ IntegraTec™ Pressurized UF In-Out Module
Preservation Instruction Manual (Form No. 45-D02946-en).

All information set forth herein is for informational purposes only. This information is general information and may differ from that based on actual conditions. Customer
is responsible for determining whether products and the information in this document are appropriate for Customer's use and for ensuring that Customer's workplace
and disposal practices are in compliance with applicable laws and other government enactments. The product shown in this literature may not be available for sale
and/or available in all geographies where DuPont is represented. The claims made may not have been approved for use in all countries. Please note that physical
properties may vary depending on certain conditions and while operating conditions stated in this document are intended to lengthen product lifespan and/or improve
product performance, it will ultimately depend on actual circumstances and is in no event a guarantee of achieving any specific results. DuPont assumes no obligation
or liability for the information in this document. References to “DuPont” or the “Company” mean the DuPont legal entity selling the products to Customer unless
otherwise expressly noted. NO WARRANTIES ARE GIVEN; ALL IMPLIED WARRANTIES OF MERCHANTABILITY OR FITNESS FOR A PARTICULAR PURPOSE
ARE EXPRESSLY EXCLUDED. No freedom from infringement of any patent or trademark owned by DuPont or others is to be inferred.

Have a question? Contact us at: © 2023 DuPont. DuPont™, the DuPont Oval Logo, and all trademarks and service marks denoted with ™, ℠ or ® Form No. 45-D04342-en, Rev. 0
www.dupont.com/water/contact-us are owned by affiliates of DuPont de Nemours Inc., unless otherwise noted. January 2023

You might also like