2-2. NE4040-70 - 200311 - LHK - Ver 1.0
2-2. NE4040-70 - 200311 - LHK - Ver 1.0
2-2. NE4040-70 - 200311 - LHK - Ver 1.0
SPECIFICATIONS:
1. The stated product performance is based on data taken after 30 minutes of operation at the following
monovalent test conditions:
• 2,000 mg/L NaCl solution at 75 psig (0.5 MPa) applied pressure
• 15% recovery
• 77 oF (25 oC)
• pH 6.5–7.0
2. The stated product performance is based on data taken after 30 minutes of operation at the following
divalent test conditions:
• 500 mg/L CaCl2 solution at 75 psig (0.5 MPa) applied pressure
• 15% recovery
• 77 oF (25 oC)
• pH 6.5–7.0
3. Minimum MgSO4 rejection is 98.0%. (Test conditions are equivalent with NaCl)
4. Permeate flow rate for each element may vary +30 / -15%.
5. Elements are supplied as dry-type. Dry elements are sealed in a poly bag and individually boxed.
1. Each membrane element supplied with one brine seal, one interconnector (coupler) and four o-rings.
All NE4040 elements fit nominal 4.0 inch (101.6 mm) I.D. pressure vessels.
The information provided in this document is solely for informative purposes. It is the user’s responsibility to ensure
the appropriate usage of this product. Toray Advanced Materials Korea Inc assumes no obligation, liability or damages
incurred for the misuse of the product or for the information provided in this document. This document does not
express or implies any warranty as to the merchantability or fitness of the product.
APPLICATION DATA:
Design Guidelines for Various · Wastewater Conventional (SDI < 5) 8–12 gfd
Water Sources · Wastewater Pretreated by UF/MF (SDI < 3) 10–14 gfd
· Seawater, Open Intake (SDI < 5) 7–10 gfd
· Seawater, Beach Well (SDI < 3) 8–12 gfd
· Surface Water (SDI < 5) 12–16 gfd
· Surface Water (SDI < 3) 13–17 gfd
· Well water (SDI < 3) 13–17 gfd
· RO permeate (SDI < 1) 21–30 gfd