Brief Introduction
LP series of low pressure element normally suitable for treatment of brackish water, surface water,
underground water and municipal water with TDS is less than 10000 ppm. It is mainly used for
producing various scales of bottle water, drinking water, industrial used pure water, high purity
water, boiler replenishment water, also for wastewater reuse, material concentration, purification
and refining purposes.
Feed Spacer
Active Membrane Average Permeate Stable Rejection
Model Thickness
Area ft2(m2) GPD(m3/d) Rate %
mil
WWW.VONTRON.COM
Notice:
1. All data and information provided in this manual have been obtained from long-term
experiment by Vontron. We confirm the effective and accuracy of the data. We assume no liability
for any consequences of user’s failure in abiding the conditions specified in this manual in use or
maintenance of membrane products. It is strongly recommended that the user shall strictly abide
the designed use and maintenance requirements and keep relevant records.
2. The permeate value listed in the table is the average value. The permeate flow of single
membrane element is tolerance not exceeding ±20% of the nominal value.
3. All wet-type membrane elements have been strictly tested before leaving the factory, and
have been treated with 1.0% sodium hydrogen sulfite (10% glycerin antifreeze required in winter)
for storage purpose, then sealed with plastic bag in vacuum, and further packed in carton boxes.
4. The membrane used should remain wet after being used; In long term suspension, to prevent
the breeding of microbes, soak the membrane elements with protective solution is highly
recommended, the solution (prepared with RO filtered water) containing 1.0% sodium hydrogen
sulfite (food grade).
5. Operate low pressure flushing for 15-25 minutes of first use, high pressure flushing for 60-90
minutes when first use (Permeate flow no less than 50% of designed flow). Discard all the
permeate and concentrated water produced during the first one hour after system start-up.
6. During storage and operation period, it is strictly prohibited to add any chemicals that may be
harmful to membrane elements. In case of any violation in adding chemicals, Vontron assumes no
liabilities for any damages incurred.
7. Along with technical development and product renovation, all information will be subject to
modification without prior notification. Please keep notice of our website for any updates of the
product.