Canature RO MEMBRANE PRODUCT DATA SHEET

Industrial Grade Reverse Osmosis Membrane


Introduction
Canature RO membrane elements are widely used in water treatment and material separation and have improved
impact resistant and antipollution property.
The tech specification specifies the basic structure, type model, performance, package, transportation, storage and
attentions.

Product specifications

Example of product type model specification:4040-2200-NPI

40 40 - 2200 - NPI or NPD


Model of membrane sheet
Average Permeate flow ,2200GPD
Length of membrane element,40inch
OD of membrane element,4inch

Membrane Element Figure

Membrane Elements Dimensions, mm


Type model A B C D Inspection tool Accept quality level
4040-2200-NPI 1016±1 101.6±1 19±1 29±1 Callipers n=20, c=0
8040-9000-NPI 1016±1 201.0±1 29±1 0 Callipers n=20, c=0

Typical Product Performance


Type model Average permeate flow Stabilized salt NaCl solution prepared pH of Temperature Applied pressure Recovery

(GPD) rejection (%) with pure water Testing solution (℃) (psi) (%)

4040-2200-NPI 2200 98 500±10 6.5-8.5 25±1 150 15

8040-9000-NPI ≥9000 99 2000±100 6.5-8.5 25±1 225 15

2016 |
Note:
‒ Permeate flow for warranty evaluation may vary ±15%
‒ Testing method: Flushing the membrane elements for 30min, then continuously operating the membrane elements for
1hr, then measure the permeate flow rate and collect the sample for measuring the salt rejection rate.
‒ AQL: n=20, C=0
‒ Membrane element can be assembled with corresponding membrane housing and no water leakage

Operating Limits

Items 4040-2200-NPI 8040-9000-NPI

Max. Operation Pressure 365psi 600psi

Max. Permeate Flow 15gpm(3.4m3/H) 70gpm(16m3/H)

Max. Operation Temperature 40℃ 40℃

Max. SDI of feed water 5 5

Concentration of free chlorine in feed water Can not find the free chlorine Can not find the free chlorine

pH rate range of feed water as continuous operation 2-11 2-11

pH range of feed water as chemical cleaning 1-12 1-12

Max. Pressure loss of per Membrane Element 20 20

Max. Pressure Loss of Pr Membrane Assy 60 60

Product Package
RO membrane elements are vacuum packaging with polyethylene bag and have corresponding mark.

Product Transportation and Storage


Do not add any influential chemical agent to membrane element during storage
Membrane elements storage place must be cool and dry, and without direct sunlight.
The temperature range must be 0-40℃ during transportation and storage.
Strictly prohibit throwing the package during transportation.

Attentions!
Each membrane element passed test and did store treatment by 1.0%sodium hydrogen sulfite( will add 10% propylene
glycol anti-freezing solution in the winter), vacuum package, then pack by carton. In order to avoid microbial growth, we
suggest soak the element and use the protective liquid including 1.0% sodium hydrogen sulfite(which from RO membrane).
When the element is first used, the first tank permeate from RO membrane element should be discard.
Do not add any influential chemical agent to membrane element during operation.