Location via proxy:   [ UP ]  
[Report a bug]   [Manage cookies]                

CSM Re8040 SHN L

Download as pdf or txt
Download as pdf or txt
You are on page 1of 2

Lenntech

RE8040R O-SHN
High Rejection
element for seawater and high salinity well water
info@lenntech.com Tel. +31-152-610-900
www.lenntech.com Fax. +31-152-616-289

SPECIFICATIONS :

General Permeate flow rate: 6,000 GPD ( 22.7 m3/day)


Features Nominal salt r ejection: 99.75%
Effective m embrane area: 370 ft2 (34.4 m2)

1. The stated product performance is based on data taken after 30 minutes of operationat the following
test conditions:

• 32,000 mg/L NaCl solution at 800 psig ( 5.5 MPa) applied pressure
• 8% recovery
• 77 o F (25 o C)
• pH 6.5 –7.0

2. Boron rejection is 92.0% at pH 8.0 and 5 mg/L boron feed with the same test conditions as above.
3. Minimum salt rejection is 99.6%.
4. Permeate flow rate for each element may vary but will be no more than 15%.
5. All elements are vacuum sealed in a polyethylene bag containing 1.0% SBS (sodium ulfite)
bis solution
and individuallypackaged in a cardboard box.

Membrane type: Thin-Film Composite


Membrane m aterial: Polyamide(PA)
Element configuration: Spiral-Wound, FRP W rapping

Dimensions Part Number


and
Weight Model Name A B C Weight Inter -
Brine Seal
connector

40.0 inch 8.0 inch 1.12 inch


RE 8040 -SHN 15 kg 40000308 40000309
(1,016 mm) (201 mm) (28 mm)

1. Each membrane elementsuppliedwith one brine seal, one interconnector (coupler) and four o-rings.
2. All RE8040 elementsfit nominal 8.0 inch (201 mm) I.D. pressure vessels.

The information provided in this document is solely for informative purposes. It is the user’s responsibility to ensure
the appropriate usage of this product.Woongjin Chemical assumes no obligation, liability or damag es incurred for the
misuse of the product or for the information provided in this document.This document does not express or implies
any warranty as to the merchantability or fitness of the product.
RE8040 -SHN
Normal grade RO element for seawat er and high salinity well water

APPLICATION DATA :

Operating Limits · Max. Pressure Drop / Element 15 psi (0.1 MPa)


· Max. Pressure Drop / 240” Vessel 60 psi (0.41 Mpa)
· Max. O peratingPressure 1,200 psi (8.27 MPa)
· Max. Feed Flow Rate 75 gpm (17.0 m3/hr)
· Min. C oncentrate Flow Rate 16 gpm (3.6 m3/hr)
· Max. O peratingTemperature 113 oF (45 oC)
· Operating pH Range 2.0–11.0
· CIP pH Range 1.0–13.0
· Max.Turbidity 1.0 NTU
· Max. SDI (15 min) 5.0
· Max. C hlorine C oncentration < 0.1 mg/L

Design Guidelines for Various · Wastewater Conventional (SDI < 5) 8–12 gfd
Water Sources · Wastewater Pretreated by UF/MF (SDI < 3) 10–14 gfd
· Seawater, O pen Intake (SDI < 5) 7–10 gfd
· Seawater, Beach Well (SDI < 3) 8–12 gfd
· SurfaceW ater (SDI < 5) 12–16 gfd
· SurfaceW ater (SDI < 3) 13–17 gfd
· Well water (SDI < 3) 13–17 gfd
· RO permeate (SDI < 1) 21–30 gfd

Saturation Limits · Langlier Saturation Index(LSI) <+1.5



(Using Antiscalants) · Stiff and Davis Saturation Index(SDSI) <+0.5
· CaSO 4 230% saturation
· SrSO 4 800% saturation
· BaSO 4 6,000% saturation
· SiO 2 100% saturation

The above saturation limits are typically accepted by proprietary antiscalant
manufacturers. It is the user’s responsibility to ensure proper chemical(s) and
concentration are dosed ahead of the membrane system to prevent scale
formation anywhere within the membrane system. Membrane elements fouled
or damaged due to scale formation are not covered by the limited warranty.

GENERAL HANDLING PROC EDURES


Elements contained in the boxes must be kept dry at Keep elements moist at all times after initial wetting.
room temperature (7–32°C; 40 –95°F) and should not be Avoid excessive pressure and flow spikes.
stored in direct sunlight. If the polyethylene bag is
damaged, a new preservative solution (sodium bisulfite) Only use chemicals compatible with the membrane
must be added and air-tight sealed to prevent drying and elements and components. Use of such chemicals may
biological growth. void the element limited warranty.
Permeate from the first hour of operation should be Permeate pressure must always be equal or less than the
discarded to flush out the preservative solution. feed/concentrate pressure. Damage caused by permeate
back pressure voids the element limited warranty.
Elements should be immersed in a preservative solution
during storage, shipping and system shutdowns to prevent
biological growth and freezing. The standard storage
solution contains 1% by weight sodium bisulfite or sodium
metabisulfite (food grade). For short term storage (i.e.
one week or less) 1% by weight sodium metabisulfite
solution is adequate for preventingbiological growth.

Lenntech
info@lenntech.com Tel. +31-152-610-900
www.lenntech.com Fax. +31-152-616-289