Location via proxy:   [ UP ]  
[Report a bug]   [Manage cookies]                

Esna1 LF2 LD 4040

Download as pdf or txt
Download as pdf or txt
You are on page 1of 1

Membrane Element ESNA1-LF2-LD-4040

(Low Fouling Technology)


3
Performance: Permeate Flow: 2,000 gpd (7.6 m /d)
CaCl 2 Rejection: 90%
CaCl 2 Rejection (minimum/maximum) 85% / 95%
* Expected calcium rejection for a typical 500 ppm well water is 96% at 13 gfd operating flux and 25ºC.

Type Configuration: Low Fouling Spiral Wound


Membrane Polymer: Composite Polyamide
2 2
Membrane Active Area: 80 ft (7.43 m )
Feed Spacer: 34 mil (0.864 mm)

Application Data* Maximum Applied Pressure: 600 psig (4.14 MPa)


Maximum Chlorine Concentration: < 0.1 PPM
Maximum Operating Temperature: 113 °F (45 °C)
pH Range, Continuous (Cleaning): 2-10 (2-12)*
Maximum Feedwater Turbidity: 1.0 NTU
Maximum Feedwater SDI (15 mins): 5.0
3
Maximum Feed Flow: 16 GPM (3.6 m /h)
Minimum Ratio of Concentrate to
Permeate Flow for any Element: 5:1
Maximum Pressure Drop for Each Element: 15 psi
* The limitations shown here are for general use. For specific projects, operating at more conservative values may
ensure the best performance and longest life of the membrane. See Hydranautics Technical Bulletins for more detail
on operation limits, cleaning pH, and cleaning temperatures.

Test Conditions
The stated performance is initial (data taken after 30 minutes of operation), based on the following conditions:

500 ppm CaCl 2


75 psi (0.52 MPa) Applied Pressure
77 °F (25 °C) Operating Temperature
15% Permeate Recovery
6.5 – 7.0 Feed pH

A
C
B PERMEATE
FEED
CONCENTRATE

A, inches (mm) B, inches (mm) C, inches (mm) Weight, lbs. (kg)


40.00 (1016) 3.95 (100.3) 0.75 (19.1) 8 (3.6)
Core tube extension = 1.05" (26.7 mm)

Notice: Permeate flow for individual elements may vary -20 or +25 percent. All membrane elements are supplied with a brine seal, interconnector, and o-rings. Elements
are enclosed in a sealed polyethylene bag containing less than 1.0% sodium meta-bisulfite solution, and then packaged in a cardboard box.

Hydranautics believes the information and data contained herein to be accurate and useful. The information and data are offered in good faith, but without guarantee, as
conditions and methods of use of our products are beyond our control. Hydranautics assumes no liability for results obtained or damages incurred through the application of the
9presented information and data. It is the user's responsibility to determine the appropriateness of Hydranautics' products for the user's specific end uses. 3/17/16

Hydranautics Corporate: 401 Jones Road, Oceanside, CA 92058


1-800-CPA-PURE Phone: 760-901-2500 Fax: 760-901-2578 info@Hydranautics.com