Location via proxy:   [ UP ]  
[Report a bug]   [Manage cookies]                

Sea2 4040 PDF

Download as pdf or txt
Download as pdf or txt
You are on page 1of 1

Model SEA2-4040

High Rejection, Excellent Productivity - Sea Water Element

Configuration: Membrane Polymer: Brine Spacer Material:


Type Spiral Wound Composite Polyamide Polypropylene

Permeate Salt Nominal Membrane


Specifications Flow: Rejection: Area:
1950 gpd 99,4% nominal 85ft2
(7,4 m3/d) (99,2% minimum) (7,9m2)

Test Conditions Solution Applied Operating Permeate pH


(After 30 min of operation) NaCl Pressure: Temperature: Recovery: Range:
32000 ppm 800 psi 77 °F 10% 6,5 ÷ 7,0
(56 bar) (25 °C)

Dimensions
A B C DF DC
Total ATD Connection Core Tube Extension Weight
Length Diameter Diameter Feed Side Conc. Side
40.0 inches 3.95 inches 0.75 inches 1.05 inches 1.05 inches 8 lbs
(1016 mm) (100,3 mm) (19,1 mm) (26,7 mm) (26,7 mm) (3,6 Kg)

A
DF DC
P Permeate
F Cn F Feed
P
F Cn Cn Concentrate
B C

Maximum Operating Limits


Operating Pressure Temperature Pressure Feed Chlorine Feedwater Feedwater
Fiberglassed Drop Flow Concentration SDI (15min) Turbidity
1000 psi 113 °F 10 psi 16 gpm <0,1 ppm 5,0 1,0 NTU
(69 bar) (45 °C) (0,7 bar) (3,6 m3)

Feedwater Minimum ratio of concentrate to


Other Operating Limits pH permeate flow for any element
3,0 ÷ 10,0 5:1

The limitations shown in Operating Limits are for general use. The values may be more conservative for specific projects to ensure the
best performance and longest life of the membrane.

Notice: Permeate flow for individual elements may vary + or -20 percent. Elements are vacuum sealed in a polyethylene bag
containing less than 1.0% sodium meta-bisulfite.

Guidelines: Permeate obtained from first hour of operation should be discarded.


Avoid static permeate-side backpressure at all times.
These membranes may be subject to drinking water application restrictions in some countries: please check the application
status before use and sale.
For element loading use only glycerine to lubricate o-rings and brine seal.

The customer is fully responsible for the effects of incompatible chemicals on elements. The presence of free chlorine and other
oxidizing agents will cause membrane failure, the damage is not covered under warranty.
Oltremare believes the information and data contained herein to be accurate and useful. The information and data are offered in good
faith, but without guarantee, as conditions and methods of use of our products are beyond our control. Oltremare assumes no liability for
results obtained or damages incurred through the application of the presented information and data. It is the user's responsibility to
determine the appropriateness of Oltremare's products for the user's specific end uses.
No performance warranties are given; all implied warranties of merchantability or fitness for a particular purpose are expressly excluded.
Consult factory for detailed warranty information.
We reserve the right to modify or amend specifications without prior notice.

Oltremare S.p.A. – via della Pineta, 23 – 61032 Fano (PU) - +39 0721 1796201 – Fax +39 0721 1796229
e-mail: info@oltremaremembrane.com http://www.oltremaremembrane.com 14/05/2015