Hydranautics Hydracore70 Membrane
Hydranautics Hydracore70 Membrane
Hydranautics Hydracore70 Membrane
1 Transition metals (Fe, Mn) should not be present in the water or on the membrane as these can accelerate detrimental reactions
between the membrane and the oxidant.
* The limitations shown here are for general use. For specific projects, operating at more conservative values may ensure the best
performance and longest life of the membrane. See Hydranautics Technical Bulletins for more detail on operation limits, cleaning
pH, and cleaning temperatures.
Performance Conditions. The stated performance is initial data (taken after 30 minutes of operation), based
on the following conditions:
500 ppm NaCl solution
77 F (25 C) Operating Temperature
15% Permeate Recovery
6.5 - 7.0 pH Range
4040 8040
A
C
B FEED PERMEAT E
CONCENT RAT E
A, inches (mm) B, inches (mm) C, inches (mm) A, inches (mm) B, inches (mm) C, inches (mm)
4040 40.0 (1016) 3.95 (100.3) 0.75 (19.05) 40.0 (1016) 7.89 (200.0) 1.50 (38.1)
Core Tube Extension = 1.05” (26.7 mm) Core tube ID = 1.125" (28.6 mm)
Notice: Elements are enclosed in a sealed polyethylene bag containing less than 1.0% sodium meta-bisulfite solution, and then packaged in a cardboard box.
All membrane elements are supplied with a brine seal, interconnector, and O-rings. Element may be tested at conditions other than stated test condition. Hydranautics believes
the information and data contained herein to be accurate and useful. The information and data are offered in good faith, but without guarantee, as conditions and methods of
use of our products are beyond our control. Hydranautics assumes no liability for results obtained or damages incurred through the application of the presented information and
data. It is the user's responsibility to determine the appropriateness of Hydranautics' products for the user's specific end uses.
11/04/14