RE8040-CE

Innovative chlorine resistant RO element for prolonged membrane lifetime

SPECIFICATIONS:

General Permeate flow rate: 12,000 GPD (45.4 m3/day)


Features Nominal salt rejection: 96%
Stabilized salt rejection: 99%
Effective membrane area: 400 ft2 (37.2 m2)

The stated product performance is based on data taken after 30 minutes of operation at the following
test conditions:

• 2,000 mg/L NaCl solution at 225 psig (1.55 MPa) applied pressure
• 15% recovery
• 77 oF (25 oC)
• pH 6.5–7.0

1. Minimum salt rejection is 96.0%.


2. Permeate flow rate for each element may vary +15 / -15%.
3. All elements are vacuum sealed in a polyethylene bag containing 1.0% SBS (sodium bisulfite) solution
and individually packaged in a cardboard box.

• Salt rejection has a tendency to


increase until 300ppm-hr of free
chlorine exposure

• Maximum Chlorine Exposure


Limit 5,000ppm-hr (After 5,000
ppm-hr of free chlorine
exposure, expect salt passage to
double from its initial value)

• Test Conditions : Equivalent to


standard conditions stated above

Membrane type: Thin-Film Composite


Membrane material: Polyamide (PA)
Element configuration: Spiral-Wound, FRP Wrapping

Dimensions Part Number


and Model Name A B C Weight
Inter-
Weight connector
Brine Seal

40.0 inch 7.9 inch 1.12 inch


RE8040-CE 15 kg SWA01049 SWA01043
(1,016 mm) (200 mm) (28.5 mm)

1. Each membrane element supplied with one


brine seal, one interconnector (coupler) and
four o-rings.

2. All RE8040 elements fit nominal 8.0 inch


(203.2 mm) I.D. pressure vessels.

The information provided in this document is solely for informative purposes. It is the user’s responsibility to ensure
the appropriate usage of this product. Toray Advanced Materials Korea Inc. assumes no obligation, liability or damages
incurred for the misuse of the product or for the information provided in this document. This document does not
express or implies any warranty as to the merchantability or fitness of the product.

Toray Advanced Materials Korea Inc.


For more information on our products, company and regional contacts, please visit our website at www.csmfilter.com.
Product Specification Sheet / Model RE8040-CE
Page 1 of 2 Rev.4.0 March 2019
RE8040-CE
Innovative chlorine resistant RO element for prolonged membrane lifetime

APPLICATION DATA:

Operating Limits · Max. Pressure Drop / Element 15 psi (0.1 MPa)


· Max. Pressure Drop / 240” Vessel 60 psi (0.41 Mpa)
· Max. Operating Pressure 600 psi (4.14 MPa)
· Max. Feed Flow Rate 75 gpm (17.0 m3/hr)
· Min. Concentrate Flow Rate 16 gpm (3.6 m3/hr)
· Max. Operating Temperature 113 oF (45 oC)
· Operating pH Range 2.0–11.0
· CIP pH Range 1.0–13.0
· Max. Turbidity 1.0 NTU
· Max. SDI (15 min) 5.0

Design Guidelines for Various · Wastewater Conventional (SDI < 5) 8–12 gfd
Water Sources · Wastewater Pretreated by UF/MF (SDI < 3) 10–14 gfd
· Seawater, Open Intake (SDI < 5) 7–10 gfd
· Seawater, Beach Well (SDI < 3) 8–12 gfd
· Surface Water (SDI < 5) 12–16 gfd
· Surface Water (SDI < 3) 13–17 gfd
· Well water (SDI < 3) 13–17 gfd
· RO permeate (SDI < 1) 21–30 gfd

Saturation Limits · Langlier Saturation Index (LSI) <+1.5


(Using Antiscalants)† · Stiff and Davis Saturation Index (SDSI) <+0.5
· CaSO4 230% saturation
· SrSO4 800% saturation
· BaSO4 6,000% saturation
· SiO2 100% saturation

The above saturation limits are typically accepted by proprietary antiscalant
manufacturers. It is the user’s responsibility to ensure proper chemical(s) and
concentration are dosed ahead of the membrane system to prevent scale
formation anywhere within the membrane system. Membrane elements fouled
or damaged due to scale formation are not covered by the limited warranty.

GENERAL HANDLING PROCEDURES


 Elements contained in the boxes must be kept dry at  Keep elements moist at all times after initial wetting.
room temperature (7–32°C; 40–95°F) and should not be  Avoid excessive pressure and flow spikes.
stored in direct sunlight. If the polyethylene bag is
damaged, a new preservative solution (sodium bisulfite)  Only use chemicals compatible with the membrane
must be added and air-tight sealed to prevent drying and elements and components. Use of such chemicals may
biological growth. void the element limited warranty.
 Permeate from the first hour of operation should be  Permeate pressure must always be equal or less than the
discarded to flush out the preservative solution. feed/concentrate pressure. Damage caused by permeate
back pressure voids the element limited warranty.
 Elements should be immersed in a preservative solution
during storage, shipping and system shutdowns to prevent
biological growth and freezing. The standard storage
solution contains 1% by weight sodium bisulfite or sodium
metabisulfite (food grade). For short term storage (i.e.
one week or less) 1% by weight sodium metabisulfite
solution is adequate for preventing biological growth.

Toray Advanced Materials Korea Inc.


For more information on our products, company and regional contacts, please visit our website at www.csmfilter.com.
Product Specification Sheet / Model RE8040-CE
Page 2 of 2 Rev.4.0 March 2019

You might also like