Sea Water RO Elements

TM800A

Type Diameter Membrane Area Salt Rejection Product Flow Rate


inch ft2 (m2) % gpd (m3/d)

TM820A-370 8" 370 (34) 99.75 5,600 (21.2)


TM820A-400 8" 400 (37) 99.75 6,000 (22.7)

1. Membrane Type Cross Linked Fully Aromatic Polyamide Composite


2. Test Conditions
Feed Water Pressure 800 psi (5.52 MPa)
Feed Water Temperature 77 ˚F (25 ˚C)
Feed Water Concentration 32,000 mg/l NaCl
Recovery Rate 8 %
Feed Water pH 8
3. Minimum Salt Rejection 99.5 %
4. Minimum Product Flow Rate 4,400 gpd ( 16.7 m3/d) (TM820A-370)
4,800 gpd ( 18.2 m3/d) (TM820A-400)
5. Boron Rejection 93% at pH8
(typical value) (5mg/l Boron added to Feed water)

Dimensions

All dimensions shown in inches (millimeter).


Feed Water

Concentrated Brine

Flow direction
1.125 (29)

7.9 (201)

TM820A-370
TM820A-400

40 (1016)

TM800A
Operating Limits

Maximum Operating Pressure 1200 psi (8.3 MPa)


Maximum Feed Water Temperature 113 ˚F (45 ˚C)
Maximum Feed Water SDI15 5
Feed Water Chlorine Concentration Not Detectable
Feed Water pH Range, Continuous Operation 2-11
Feed Water pH Range, Chemical Cleaning 1-12
Maximum Pressure Drop per Element 20 psi (0.14 MPa)
Maximum Pressure Drop per Vessel 60 psi (0.4 MPa)

Operating Information

1. For the recommended design range, please consult the latest Toray technical bulletin, design guide-
lines, computer design program, and/or call an application specialist. If the operating limits giv-
en in this Product Information Bulletin are not strictly followed, the Limited Warranty will be null
and void.
2. All elements are wet tested, treated with tested feed water solution, and then vacuum packed in
oxygen barrier bags with deoxidant inside. To prevent biological growth during system shutdown,
it is recommended to perform 30-60 minutes flushing of Toray elements with seawater once in every
two days.
3. Permeate from the first hour of operation shall be discarded.
4. The customer is fully responsible for the effects of chemicals that are incompatible with the ele-
ments. Their use will void the element Limited Warranty.

Notice

1. Toray accepts no responsibility for results obtained by the application of this information or the
safety or suitability of Toray's products, either alone or in combination with other products. Users
are advised to make their own tests to determine the safety and suitability of each product combi-
nation for their own purposes.
2. All data may change without prior notice, due to technical modifications or production changes.