Brackish Water RO Elements


TML20D
Type Diameter Membrane Area Salt Rejection Product Flow Feed Spacer
Inch ft2(m2) % Rate Thickness
gpd(m3/d) mil

TML20D-370 8” 370(34) 99.8 9,700(36.7) 34


TML20D-400 8” 400(37) 99.8 10,500(39.8) 34
TML20DA400 8” 400(37) 99.8 10,500(39.8) 31
TML20D-440 8” 440(41) 99.8 11,500(43.6) 28

1. Membrane Type Cross Linked Fully Aromatic Polyamide Composite

2. Test Conditions
Feed Water Pressure 225 psi(1.55 MPa)
Feed Water Temperature 77 °F(25 ℃)
Feed Water Concentration 2,000 mg/l NaCl
Recovery Rate 15 %
Feed Water pH 7
3. Minimum Salt Rejection 99.65 %
4. Minimum Product Flow Rate 7,800 gpd(29.5 m3/d)
8,400 gpd(31.8 m3/d)
8,400 gpd(31.8 m3/d)
9,200 gpd(37.4 m3/d)

Dimensions

All dimensions shown in Inches (millimeter).

F Feed Water

B Concentrated Brine

Flow direction

TML20D-370
F B
1.125(29)

TML20D-400
7.9(201)

PERMIATE
TML20DA400 F
B
TML20D-440

40(1,016)
Operating Limits

Maximum Operating Pressure 600psi (4.1 MPa)


Maximum Feed Water Temperature 113°F (45℃)
Maximum Feed Water SDI15 5
Feed Water Chlorine Concentration <0.1ppm
Feed Water pH Range, Continuous Operation 2-11
Feed Water pH Range, Chemical Cleaning 1-13
Maximum Pressure Drop per Element 20psi (0.14 MPa)
Maximum Pressure Drop per Vessel 60psi (0.4 MPa)

Operating Information
1. For the recommended design range, please consult the latest Toray technical bulletin, design guide
lines, computer design program, and/ or call an application specialist. If the operating limits given in
this Product Information Bulletin are not strictly followed, the Limited Warranty will be null and void.
2. All elements are wet tested, treated with a 1% by weight percent sodium bisulfite storage solution,
and then vacuum packed in oxygen barrier bags, or treated with tested feed water solution, and then
vacuum packed in oxygen barrier bags with deoxidant inside. To prevent biological growth during
short term storage, shipment, or system shutdown, it is recommended that Toray elements be
immersed in a protective solution containing 500 - 1,000 ppm of sodium bisulfite (food grade)
dissolved in permeate.
3. The presence of free chlorine and other oxidizing agents under certain conditions, such as heavy
metals which acts as oxidation catalyst in the feed water will cause unexpected oxidation of the
membrane. It is strongly recommended to remove these oxidizing agents contained in feed water
before operating RO system.
4. Permeate from the first hour of operation shall be discarded.
5. The customer is fully responsible for the effects of chemicals that are incompatible with the elements.
Their use will void the element Limited Warranty.

Notice

1. Toray accepts no responsibility for results obtained by the application of this information or the safety
or suitability of Toray's products, either alone or in combination with other products. Users are
advised to make their own tests to determine the safety and suitability of each product combination
for their own purposes.
2. All data may change without prior notice, due to technical modifications or production changes.

Lenntech
info@lenntech.com Tel. +31-152-610-900
www.lenntech.com Fax. +31-152-616-289
Sep. 2012

You might also like