Vontronfr12 8040en1
Vontronfr12 8040en1
Vontronfr12 8040en1
Brief Introduction
FR12-8040 RO Membrane Element utilizes specialized manufacture technique that can improve
the hydrophilicity, electric charge and roughness of its surface, thus reducing the breeding and
adsorption of pollutants and microbes on membrane surface.
FR series of fouling resistant membranes normally suitable for treatment of complex water source
with TDS less than 10000 ppm. It is mainly used for purification of surface water, mining waste
water, municipal reclaimed water, industrial waste water, RO brackish water, etc.
WWW.VONTRON.COM
Notice:
1. All data and information provided in this manual have been obtained from long-term
experiment by Vontron. We confirm the effective and accuracy of the data. We assume no liability
for any consequences of user’s failure in abiding the conditions specified in this manual in use or
maintenance of membrane products. It is strongly recommended that the user shall strictly abide
the designed use and maintenance requirements and keep relevant records.
2. The permeate value listed in the table is the average value. The permeate flow of single
membrane element is tolerance not exceeding ±15% of the nominal value.
3. All wet-type membrane elements have been strictly tested before leaving the factory, and
have been treated with 1.0% sodium hydrogen sulfite (10% glycerin antifreeze required in winter)
for storage purpose, then sealed with plastic bag in vacuum, and further packed in carton boxes.
4. The membrane used should remain wet after being used; In long term suspension, to prevent
the breeding of microbes, soak the membrane elements with protective solution is highly
recommended, the solution (prepared with RO filtered water) containing 1.0% sodium hydrogen
sulfite (food grade).
5. Operate low pressure flushing for 15-25 minutes of first use, high pressure flushing for 60-90
minutes when first use (Permeate flow no less than 50% of designed flow). Discard all the
permeate and concentrated water produced during the first one hour after system start-up.
6. During storage and operation period, it is strictly prohibited to add any chemicals that may be
harmful to membrane elements. In case of any violation in adding chemicals, Vontron assumes no
liabilities for any damages incurred.
7. Along with technical development and product renovation, all information will be subject to
modification without prior notification. Please keep notice the website of Vontron for any updates
of the product.
WWW.VONTRON.COM