Product Data Sheet

FilmTec™ XLE PRO-4040 &


XLE PRO-2540
Tape-Wrapped Low Energy Large Commercial Elements for Commercial Applications

Key Features Key Applications


l High flux results in high yields l Drinking & Commercial water applications for plant sizes
l Produce good water quality at very low applied pressure for ≤ 500L/hr (0.5M3/hr) – Hotels, Restaurants, Cafes, Car wash,
drinking water and commercial applications schools, refiling stations, etc.

Typical Properties
Permeate Flow Rate Stabilized Salt
Product Part number gpd (m3/d) Rejection (%)
XLE PRO-4040 12082995 2,750 (10.4) 99.0
XLE PRO-2540 2082909 1,200 (4.5) 99.0
1. Permeate flow and salt rejection based on the following test conditions: 77°F (25°C), 15% recovery, applied pressure 125 psig (8.7 bar), pH 8, and based on a 2,000
ppm NaCl feed stream.
2. Minimum salt rejection is 97.0%.
3. Permeate flows for individual elements may vary +/-20%.
4. For the purpose of improvement, specifications may be updated periodically.

Element Dimensions
Dimensions – Inches (mm)
1 inch = 25.4 mm
Product A B C D
XLE PRO-4040 40.0 1.05 0.75 3.9
(1,016) (26.7) (19) (99)
XLE PRO-2540 40.0 1.19 0.75 2.4
(1,016) (30.2) (19) (61)

1. Refer to FilmTec™ Design Guidelines for multiple-element systems of midsize elements


(Form No. 45-D01588-en).
2. FilmTec™ XLE PRO-4040 Elements fit nominal 4-inch I.D. pressure vessel.
Operating and Cleaning Limits
Membrane Type Polyamide Thin-Film a. Maximum temperature for continuous operation above pH 10 is 95°F
(35°C).
Composite b. Refer to FilmTec™ Cleaning Guidelines (Form No. 45-D01696-en).
Maximum Operating Temperature 113°F (45°C) c. Under certain conditions, the presence of free chlorine and other
Maximum Operating Pressure 600 psig (41 bar) oxidizing agents will cause premature membrane failure. Since oxidation
damage is not covered under warranty, DuPont Water Solutions
Maximum Feed Flow Rate 14 gpm (3.2 m3/hr) recommends removing residual free chlorine by pretreatment prior to
Maximum Pressure Drop 13 psig (0.9 bar) membrane exposure. Please refer to FilmTec™ Design Guidelines for
multiple-element systems of 8-inch elements (Form No. 45-D01695-en) for
pH Range
more information.
Continuous Operationa 2 - 11
Short-Term Cleaning (30 min.)b 1 - 13
Maximum Feed Silt Density Index SDI 5
(SDI)
Free Chlorine Tolerancec <0.1 ppm

General Information Important Information


l Keep elements moist at all times after initial wetting. l Proper start-up of reverse osmosis water treatment systems
l If operating limits and guidelines given in this bulletin are not is essential to prepare the membranes for operating service
strictly followed, the limited warranty will be null and void. and to prevent membrane damage due to overfeeding or
l To prevent biological growth during prolonged system hydraulic shock. Following the proper start-up sequence also
shutdowns, it is recommended that membrane elements be helps ensure that system operating parameters conform to
immersed in a preservative solution. design specifications so that system water quality and
l The customer is fully responsible for the effects of productivity goals can be achieved.
incompatible chemicals and lubricants on elements. l Before initiating system start-up procedures, membrane
l Maximum pressure drop across an entire pressure vessel pretreatment, loading of the membrane elements,
(housing) is 30 psi (2.1 bar). instrument calibration and other system checks should be
l Avoid static permeate-side backpressure at all times. completed.
l Avoid any abrupt pressure or cross-flow variations on the l Please refer to the application information literature entitled
spiral elements during start-up, shutdown, cleaning or other Start-Up Sequence (Form No. 45-D01609-en) for more
sequences to prevent possible membrane damage. During information.
start-up, a gradual change from a standstill to operating state
is recommended as follows: Regulatory Note
– Feed pressure should be increased gradually over a 30-60
second time frame. This product may be subject to drinking water application
– Cross-flow velocity at set operating point should be restrictions in some countries; please check the application
achieved gradually over 15-20 seconds. status before use and sale.
l The use of this product in and of itself does not necessarily
guarantee the removal of cysts and pathogens from water.
Effective cyst and pathogen reduction is dependent on the
complete system design and on the operation and
maintenance of the system.
l Permeate obtained from the first hour of operation should be
discarded.

info@lenntech.com Tel. +31-152-610-900


www.lenntech.com Fax. +31-152-616-289

All information set forth herein is for informational purposes only. This information is general information and may differ from that based on actual conditions. Customer
is responsible for determining whether products and the information in this document are appropriate for Customer's use and for ensuring that Customer's workplace
and disposal practices are in compliance with applicable laws and other government enactments. The product shown in this literature may not be available for sale
and/or available in all geographies where DuPont is represented. The claims made may not have been approved for use in all countries. Please note that physical
properties may vary depending on certain conditions and while operating conditions stated in this document are intended to lengthen product lifespan and/or improve
product performance, it will ultimately depend on actual circumstances and is in no event a guarantee of achieving any specific results. DuPont assumes no obligation
or liability for the information in this document. References to “DuPont” or the “Company” mean the DuPont legal entity selling the products to Customer unless
otherwise expressly noted. NO WARRANTIES ARE GIVEN; ALL IMPLIED WARRANTIES OF MERCHANTABILITY OR FITNESS FOR A PARTICULAR PURPOSE
ARE EXPRESSLY EXCLUDED. No freedom from infringement of any patent or trademark owned by DuPont or others is to be inferred.

© 2022 DuPont. DuPont™, the DuPont Oval Logo, and all trademarks and service marks denoted with ™, ℠ or ® Form No . 45-D03972-en, Rev. 1
are owned by affiliates of DuPont de Nemours Inc., unless otherwise noted. March 2022

You might also like