Filmtec BW30-400:34i
Filmtec BW30-400:34i
Filmtec BW30-400:34i
Description Ideal for: reverse osmosis plant managers and operators dealing with
challenging waters and wastewaters and looking for consistency, high
performance, long element life, increased productivity and low fouling
features.
the risk of o-ring leaks that can cause poor water quality
Typical Properties
Active Area Feed Spacer Permeate Flow Rate Typical Stabilized Minimum Salt
FilmTec™ Element (ft2) (m2) Thickness (mil) (GPD) (m3/d) Salt Rejection (%) Rejection (%)
BW30-400/34i 400 37 34 10,500 40 99.5 99.0
1. Permeate flow and salt (NaCl) rejection based on the following standard test conditions: 2,000 ppm NaCl,
225 psi (15.5 bar), 77°F (25°C), pH 8, 15% recovery.
2. Flow rates for individual elements may vary but will be no more than 15% below the value shown.
3. Stabilized salt rejection is generally achieved within 24-48 hours of continuous use; depending upon
feedwater characteristics and operating conditions.
4. Sales specifications may vary as design revisions take place.
5. Active area guaranteed ± 3%. Active area as stated by DuPont Water Solutions is not comparable to nominal
membrane area often stated by some manufacturers.
Additional Before use or storage, review these additional resources for important information:
l Usage Guidelines for FilmTec™ 8” Elements (Form No. 45-D01706-en)
Important
l Start-Up Sequence (Form No. 45-D01609-en)
Information
Product DuPont has a fundamental concern for all who make, distribute, and use its products, and
Stewardship for the environment in which we live. This concern is the basis for our product stewardship
philosophy by which we assess the safety, health, and environmental information on our
products and then take appropriate steps to protect employee and public health and our
environment. The success of our product stewardship program rests with each and every
individual involved with DuPont products—from the initial concept and research, to
manufacture, use, sale, disposal, and recycle of each product.
cysts and pathogens from water. Effective cyst and pathogen reduction is
dependent on the complete system design and on the operation and maintenance
of the system.
l Permeate obtained from the first hour of operation should be discarded.
Regulatory Note This product may be subject to drinking water application restrictions in some
countries; please check the application status before use and sale.
Have a question? Contact us at: All information set forth herein is for informational purposes only. This information is general information and may differ from that based
on actual conditions. Customer is responsible for determining whether products and the information in this document are appropriate for
www.dupont.com/water/contact-us
Customer's use and for ensuring that Customer's workplace and disposal practices are in compliance with applicable laws and other
government enactments. The product shown in this literature may not be available for sale and/or available in all geographies where
DuPont is represented. The claims made may not have been approved for use in all countries. Please note that physical properties may
vary depending on certain conditions and while operating conditions stated in this document are intended to lengthen product lifespan
and/or improve product performance, it will ultimately depend on actual circumstances and is in no event a guarantee of achieving any
specific results. DuPont assumes no obligation or liability for the information in this document. References to “DuPont” or the “Company”
mean the DuPont legal entity selling the products to Customer unless otherwise expressly noted. NO WARRANTIES ARE GIVEN; ALL
IMPLIED WARRANTIES OF MERCHANTABILITY OR FITNESS FOR A PARTICULAR PURPOSE ARE EXPRESSLY EXCLUDED. No
freedom from infringement of any patent or trademark owned by DuPont or others is to be inferred.
© 2022 DuPont. DuPont™, the DuPont Oval Logo, and all trademarks and service marks denoted with ™, ℠ or ® are owned by
affiliates of DuPont de Nemours Inc., unless otherwise noted.