SPECIFICATIONS
General Features
Permeate Flow Rate GPD (L/Day) 800 GPD (3,028/day)
NaCl Rejection % 96% (Minimum 94%)
Membrane Type Thin-Film Composite
Membrane Material Polyamide (PA)
Element Configuration Spiral-Wound, Tape Wrapping
The stated product performance is based on data taken after 30 minutes of operation at the following test Conditions: 200 mg/L NaCl solution at 80
psig (0.55 MPa) applied pressure; 40% recovery; 77℉ (25℃); pH 6.5–7.0; Permeate flow rate for each element may vary +20 / -20%; Minimum salt
rejection is 94.0%; All elements are vacuum leak tested using the CSM integrity test; Elements can be supplied as dry or wet-type. Wet-tested elements
are soaked in a preservative solution (1.0% food grade SBS) and vacuum sealed in a poly bag. All elements are individually boxed.

Dimensions
Model Name A B C D E
0.67 inch 0.39 inch 11.73 inch 0.79 inch 2.95 inch
RE3012-800
(17 mm) (10 mm) (298 mm) (20 mm) (75 mm)

APPLICATION DATA
Operating Limits
Max. Operating Pressure 150 psi (1.03 MPa)
Max. Feed Flow Rate 2 gpm (0.45 m3/hr)
Max. Operating Temperature 113oF (45oC)
Operating pH Range 2.0 – 11.0
Max. Turbidity 1.0 NTU
Max. SDI (15 min) 3.0
Max. Chlorine Concentration < 0.1 mg/L

GENERAL HANDLING PROCEDURES


 Elements contained in the boxes must be kept dry at room  Avoid excessive pressure and flow spikes.
temperature (7–32°C; 40–95°F) and should not be stored in  Only use chemicals compatible with the membrane elements and
direct sunlight. components. Use of such chemicals may void the element limited
 For WET-TYPE, the preservative solution (1% sodium warranty.
metabisulfite solution) is added to prohibit the growth of  Permeate pressure must always be equal or less than the
micro-organisms. feed/concentrate pressure. Damage caused by permeate back
 Permeate from the first hour of operation should be discarded. pressure voids the element limited warranty.
 Stabilized salt rejection is generally achieved within 1~48 hours
of continuous use.
 Keep elements moist at all times after initial wetting.