SPECIFICATIONS
Pressure Range: 14.7 to 0 PSIA (0 to -760 mmHg) Venting Port: M3
Units Displayed: mmHg, kPa, bar, inHg Pressure Port: 1/8" NPT
Max Pressure: 5 kgf/cm3 Protection Structure: Conforming to IP65 except cable
Media: Non-corrosive gas which is IP40
Operating Temperature: 32° to 122°F (0 to 50°C) Power Supply: DC 10.8 to 30V, max. 10% ripple
Operating Humidity: 35 to 85% RH (no condensation) Current Consumption: 45 mA or less
Repeatability: ±1% of F.S. or less Vibration Resistance: 10 to 55 Hz, 1.5 mm amplitude,
Output: NPN (N), open collector, XYZ, 2 hours
max. 125 mA, 2 points Shock Resistance: 1000 m/s2 (approx. 100G) XYZ
Display: 3-digit and 7-segmented LED Spike Protection: 350 VP -P, 10 ms, 0.5 µ s
(character height 8mm) Dielectric Strength: AC 1000 V for one (1) minute
Display Frequency: 5 times / second Material:
Protection Circuit: Reverse wiring protection, Body Polycarbonate
surge absorption, Pressure Port Zinc diecasting
Vacuum
over-current protection Weight: .08 lb. (35 g), not including cable
D
PART NUMBER P5V-SAVN12C
DIMENSIONS
1/8 NPT
.63 (16) 2.323 (59)
2 x 2M x .4
SPECIFICATIONS
Pressure Range:
Switch Body 40 to 120 PSI (3 to 8 bar)
Operating Head -14 to 7250 PSI (-1 to 500 bar)
Flow at 90 PSI (6 bar): 7.4 SCFM (210 l/mn ANR)
Nominal Bore: 1/8"
Operating Temperature: 5° to 140°F (-15° to 60°C)
Repeatability: Variation from differential setting
<2% (between 2 consecutive
cycles)
Maximum Operating
Frequency: 30 operations/minute
SETTING
Vibration Resistance: 4g (10 to 500 Hz)
Turn the ring until the lower part
Shock Resistance: 100g of the ring corresponds with the
Degree of Protection: NEMA4 (IP65) setting required as indicated on
Materials: the scale. Setting can be verified
Switch Body Zinc alloy by connecting a pressure gauge
Operating Head Brass and cadmium steel to the fluid suply line. 0.3 BAR 35.PSI
BARS G8 PSI
NVA : 8 PRES
ORDERING INFORMATION
Range Adjustment* Differential Range** Maximum Admissible
Model Number Type of Switching Min. Max. Lower Upper Pressure***
3" Hg 30" Hg 2.4" Hg 3" Hg 1.5 PSI
PXMJB111091 NNP
(-0.1 bar) (-1 bar) (-0.08 bar) (-0.1 bar) (0.1 bar)
3" Hg 30" Hg 2.7" Hg 3" Hg 1.5 PSI
PXMJB121091 NP
(-0.1 bar) (-1 bar) (-0.09 bar) (-0.1 bar) (0.1 bar)
* Adjustment range is minimum and maximum adjustment limitations between which the upper operating point can be set.
** Upper differential is the pressure hysterisis at maximum adjusted pressure setting. Lower differential is the pressure
hysterisis at minimum adjusted pressure setting.
*** Maximum admissible pressure is the maximum pressure the switch can withstand per cycle without affecting its
performance or life expectancy.
DIMENSIONS
38
38
= 30 =
25
13
11
11
41
12
21
28
4XØ5,2
142
inch mm
a 1.10 28
b .83 21
c .47 12
d .43 11
e .51 13 5,4
f .94 24
16
ØG 1/4" female 33
20 / 22 19 16
MOUNTING
Vacuum
D
On the fluid supply line By the bracket supplied By the pneumatic switch body
CONNECTION
SPECIFICATIONS
Port: 1/8" NPT
Voltage: 24 DC (125 AC optional)
Set point: 5 to 30 inches Hg
Repeatability: ± 2% at 70°F (x°C)
Hysteresis: 25% of preset value
Max. pressure: 350 PSI
Temperature range: -40° to +176°F
-40° to +80 °C
Electrical loading: Inductive: 5 Amp
Resistive: 7 Amp
Electrical connection: DIN43650A SET POINT ADJUSTMENT
Material:
Body Black anodized aluminum 1. Remove DIN adaptor.
Diaphragm Epichlorohydrin 2. Remove small brass screw.
Weight: 0.5 lb (.23 kg) 3. Using 1/8" Allen wrench, adjust counter-clockwise to
Type: Digital increase set point or clockwise to decrease set point.
4. Reverse steps 1 & 2 for reassembly.
DIMENSIONS
A
50
Key inch mm
A 1.97 50
B 4.00 101
C 1.24 31.6
D .76 19.3
E .39 10
F .53 13.5
G .80 20.3
B108
NV 29
20,3
G
13,5
F
10
E
1/8"
G1/8
D
19,3
C
31,6
Vacuum
check valve
Vacuum
Flow
D
DIMENSIONS 0.38 (9.6) 1/4 NPT
1/8 NPT
0.56 (14)
1.92 (49)
2.31 (59)
VACUUM GAUGE
Vacuum gauges are used to measure and indicate vacuum
pressure in pneumatic systems.
SPECIFICATIONS
Connection: 1/8" NPT bottom connection
Design: Bourdon tube (Beryllium copper)
Range: 0 to 30 inches Hg
Accuracy: ± 3-2-3% of full scale
Material:
Case Black steel
Connection Brass
Pointer Black aluminum
Window Glass
Dial Face: 2" diameter
MUFFLERS
Mufflers are used in exhaust ports on vacuum generators.
Vacuum mufflers offer greater air flow with less pressure
drop than sintered bronze mufflers, while providing noise
dampening characteristics.
DATA
P6M-PA92 P6M-PA93 P6M-PA94 PM6-PA96
Port (NPT or BSP) 1/4 3/8 1/2 3/4
Media Air
Pressure 0 - 130 PSI (0 - 9.2 bar)
Temperature -41° to 140°F (-40° to 60°C)
Body Material Acetal
Weight, oz. (g) .22 (6.2) .68 (19.3) 3.07 (87) 4.44 (126)
A (NPT or BSPP)
DIMENSIONS
Inches (mm)
A ∅B C D
.77 .31 1.37 ∅B
P6M-PA92 1/4
(19.5) (8) (35)
.96 .43 1.85
P6M-PA93 3/8
(24.5) (11) (47) C
.96 .43 1.85
P6M-PA94 1/2
(24.5) (11) (47)
P6M-PA96 3/4
1.9 .7 3.83 D
(48) (18) (97)
FILTERS
Air filters are designed to remove airborne solid contami-
nants from the suction line.
FEATURES:
• Unique deflector plate creates a swirling of the air stream,
ensuring maximum dirt separation.
• Easily disassembled for servicing without the use of tools.
GENERAL CHARACTERISTICS:
Operating temperature: 32° to 125°F (0° to 52°C)
DATA
Part # Port Rated Flow Bowl Bowl Filter Element Pressure Body Seals Drain
(NPT) SCFM (l/min) Capacity Range
75 micron prefilter 0 - 50 PSI
ILN40P05011 1/8" 2.1 (60) — — Nylon Silicone —
30 micron filter (0 - 3.5 bar)
14F01AA 1/8" 2.4 (68) 1 Oz.
06F11AC 1/4" 5.9 (167) 4.4 Oz.
0 - 125 PSI
06F21AC 3/8" 8.4 (238) 4.4 Oz. Polycarbonate 40 micron Zinc Nitrile Manual Twist
(0 - 8.6 bar)
07F31AC 1/2" 13.5 (382) 7.2 Oz.
07F41AC 3/4" 14.9 (422) 7.2 Oz.
Vacuum
D
➤ A ➤
➤
➤
A
➤
DIMENSIONS
D
Part # A B C D
➤
1.83" 3.25" — —
ILN40P05011
➤
46.5 mm 82.5mm — — A C
➤