Location via proxy:   [ UP ]  
[Report a bug]   [Manage cookies]                

Intrinsically Safe Fluke 718ex 30G, 100G, and 300G Pressure Calibrators

Download as pdf or txt
Download as pdf or txt
You are on page 1of 2

Intrinsically Safe

Fluke 718Ex 30G,


100G, and 300G
Pressure Calibrators
Pump Up the Pressure
Technical Data
The new Fluke 718Ex Intrinsically Safe Pressure Calibrator
is a powerful new intrinsically safe, self contained pressure
calibration solution that offers:

• ATEX II 1G EEx ia IIC • Wide range of selectable


T4 compliance measurement units for
pressure
• I.S. Class I, Division
1 compliance • Current measurement
with 0.02 % accuracy and
• Built-in pressure/vacuum 0.001 mA resolution
hand pump, with vernier
and bleed valve • Pressure switch test function
• Pressure measurement to • Min/Max hold functions
0.05 % of full span, using an • Compact size and weight
internal pressure sensor • Simple, push-button user
• Pressure measurement to interface
3,000 psi/200 bar using • Rugged and reliable, for
any of the 8 intrinsically field use
safe Fluke 700PEx Pressure
Modules • Pressure switch test function

Pressure specifications (internal sensor)


18 °C to 28 °C, one year
Pressure Input
Range Resolution Accuracy
-12 psi to 30 psi .001 psi (0.01 kPa) .05 % FS
(-82.7 kPa to 207 kPa)
-12 psi to 100 psi .01 psi (0.01 kPa) .05 % FS
(-82.7 kPa to 690 kPa)
-12 psi to 300 psi .01 psi (0.01 kPa) .05 % FS Ordering information
(-82.7 kPa to 2068 kPa)
Model
Temp Coeff. -10 °C to + .01 % of range per °C Fluke-718Ex 30G Pressure Calibrator
18 °C, 28 °C to 55 °C
Fluke-718Ex 100G Pressure Calibrator
Engineering Units (in Hg) Fluke-718Ex 300G Pressure Calibrator
PSI, in. H2O (4 °C), in. H2O (20 °C), kPa, cm H2O (4 °C), Included accessories
cm H2O (20 °C), BAR, mBAR, kg/cm2, mmHg, in Hg Protective red holster, TL75 test leads, AC72 test clips, CD users
manuals (English, French, German, Spanish, Italian, Dutch,
Media Norwegian, Danish, Swedish, Finnish, Portuguese, Korean,
Gasses (non corrosive) Chinese, Japanese), Fluke 718Ex CCD control drawing
Overpressure
I.S. Class I Div 1 Groups A-D T4
3 x F.S. on 30G AEx ia IIC T4
2 x F.S. on 100G
375 PSI on 300G II 1 G EEx ia IIC T4
KEMA 04 ATEX 1061

Ta = -10 °C to +55 °C
Specifications continued

Pressure display (external modules) Operating modes


Pressure Module Readout Mode
Pressure range Determined by pressure module Measure pressure (using internal sensor)
Resolution 5 digits Display pressure module reading (automatically selected when pressure module
Accuracy Determined by pressure module connected)
Engineering Units (in Hg) Measure current
PSI, in. H2O (4 °C), in. H2O (20 °C), Kpa, cm H2O (4 °C),
cm H2O (20 °C), BAR, mBAR, Kg/cm2, mmHg, in Hg
Input/output
Current specifications Pressure input 1/8 in. NPT pressure fitting
18 °C to 28 °C, one year Pressure module input LEMO connector
Current Measurement Current input Shrouded banana jacks
Range 0 mA to 24 mA
Resolution .001 mA
mA ± 5 °C .02 % Rdg ± 2 count Battery
Temp Coeff. Power One 9-volt alkaline battery
to 18 °C, ± .005 % of range per °C
to 55 °C Battery life 4 to 20 hours, depending on functions used

Zeroing modes
Mode
Gage and Pushing Zero button stores present pressure value as an offset and subtracts it
differential from the displayed value
Absolute Pushing Zero button causes nominal barometric pressure to be displayed. User corrects
to actual barometric pressure with up/down keys. Difference is used as zero offset calibration.

Pressure module specification


(All specifications in % of full span. Specifications reflect a confidence interval of 95 %.)

Range Reference High2 Low2 Max over-


Range/ (approx)/ uncertainty Stability Temperature Total1 side side Fitting pressure
Model Resolution Resolution (23 ± 3 ºC) (1 year) (0 to 50 ºC) uncertainty media media material (x nominal)
Differential
FLUKE-700P01Ex 10 in. H2O/0.01 2.5 kPa/0.002 0.200 0.050 0.050 0.300 Dry Dry 316 SS 3x
FLUKE-700P24Ex 15 psi/0.001 103 kPa/0.01 0.025 0.010 0.015 0.050 316 SS Dry 316 SS 3x
Gage
FLUKE-700P05Ex 30 psi/0.001 207 kPa/0.01 0.025 0.010 0.015 0.050 316 SS N/A 316 SS 3x
FLUKE-700P06Ex 100 psi/0.01 690 kPa/0.07 0.025 0.010 0.015 0.050 316 SS N/A 316 SS 3x
FLUKE-700P27Ex 300 psi / 0.01 2070 kPa / 0.1 0.025 0.010 0.015 0.050 316 SS N/A 316 SS 3x
FLUKE-700P09Ex 1500 psi/0.1 10 MPa/0.001 0.025 0.010 0.015 0.050 316 SS N/A 316 SS 2x
Absolute
FLUKE-700PA4Ex 15 psi/0.001 103 kPa/0.01 0.050 0.010 0.010 0.070 316 SS N/A 316 SS 3x
High
FLUKE-700P29Ex 3000 psi/0.1 20.7 M Pa/0.001 0.050 0.010 0.020 0.080 C276 N/A C276 2x
1
Total uncertainty, one year for temperature range 0 °C to +50 °C. Total uncertainty, 1.0 % of full span for temperature range -10 °C to 0 °C.
2
“Dry” indicates dry air or non-corrosive gas as compatible media. “316 SS” indicates media compatible with Type 316 Stainless Steel. “C276”
indicates media compatible with Hastelloy C276.

Fluke. Keeping your world


Environmental and safety requirements up and running.®
Operating temperature -10 °C to 55 °C
Non-operating temperature -40 °C to 71 °C Fluke Corporation
PO Box 9090, Everett, WA USA 98206
Relative humidity 95 % (10 °C to 30 °C)
(%RH operating 75 % (30 °C to 40 °C) Fluke Europe B.V.
without condensation) 45 % (40 °C to 50 °C) PO Box 1186, 5602 BD
35 % (50 °C to 55 °C) Eindhoven, The Netherlands
Size (LxWxD) 216 mm x 94 mm x 66 mm (8.50 in x 3.72 in x 2.60 in) For more information call:
In the U.S.A. (800) 443-5853 or
Weight 35 oz (992 g) Fax (425) 446-5116
Vibration Random, 2g, 5-500 Hz In Europe/M-East/Africa +31 (0) 40 2675 200 or
Fax +31 (0) 40 2675 222
Shock 1 Meter Drop test
In Canada (800)-36-FLUKE or
EMC EN61326 2002-02, Criteria C Fax (905) 890-6866
From other countries +1 (425) 446-5500 or
Fax +1 (425) 446-5116
Web access: http://www.fluke.com
©2007-2008 Fluke Corporation. All copyrights are
the property of their respective owners. Specifications
subject to change without notice. Printed in U.S.A.
5/2008 2116965 D-EN-N Rev E

You might also like