Proportional Flow Control Valve 3


Product group

G PC P 040
Function
zz 2/2 NC
zz Proportional direct-acting
zz Media: H2, N2, air, mixture of H2 and N2
zz Wide proportionality between solenoid current and flow rate
zz Nominal working pressure (NWP) 16 barg
zz Maximum pressure (MAWP) up to 25 barg
zz Low leakage
zz High switching life time
Fig. 1: Type G PC P 040 K69 V01
Construction
zz Compact design
zz Central fastening or flange mounting
zz Protection class according to DIN EN 60529: IP6K9K
if mounted properly and with suitable mating connector
zz Electrical connection via plug TE MCP 2.8 mm
Application examples
zz Fuel gas quantity control in fuel cells
Standards and tests
zz IATF 16949 Fig. 1: Type G PC P 040 K69 V03 / V04

Options and accessories on request


zz Various electrical plug connections
zz Other control pressure ranges
zz ATEX version for stationary applications
zz Customer-specific mechanical interface
zz Version for natural gas

Magnet-Schultz GmbH & Co. KG • Allgäuer Straße 30 • D-87700 Memmingen • Tel. +49 83 31 10 40 • www.magnet-schultz.com
Technical data
G PC P 040 K69 ... V01 / V04 V03
Function 2/2 NC
Operation principle proportional direct acting
Voltage control PWM > 350 Hz
Rated voltage UN (V DC) 12 (9 ... 16) / 24 (18 ... 32)
Rated resistance R20 (Ω) 4.8 / 21.4
Rated current IN (A) 1.6 / 0.8
Limit current IG (A) 1.6 / 0.8
Rated power P20 (W) 12 (1.6 A) / 13.5 (0.8 A)
Inductance (mH) 12.3 (1 kHz, 1 V, 1.6 A)
Isolation class H
Relative duty cycle S1 100% ED (depending on installation space and heat dissipation)
Ambient temperature (°C) -40 ... +100
Protction class IP6K9K
Service life (full stroke, control action) > 3.000.000, > 25.000.000
Nominal width (mm) 2.8 3.3
Kv at IN (m /h)
3
0.23 0.32
Rated operating pressure (NWP) (barg) 16
Maximum input pressure (MAWP) (barg) 25 20
Burst pressure (barg) > 3xMAWP
Circuit diagram

Hysteresis (10-90%, 350 Hz PWM) < 15% FS (5 -> 0 bar)


Linearity (10-90%, 350 Hz PWM) < 10% FS (5 -> 0 bar)
Reaction time (ms) 30 @ 0-100%, PWM: 1000Hz, UN
Media air, H2 (gaseous hydrogen)
Leakage P-seat (Helium @ p=MAWP) (mbar l/s) 1x10-4
Leakage A-space (Helium @ p=MAWP) (mbar l/s) 1x10-4
Weight (kg) 0.42
Compliant to Regulation (EC) No. 1907/2006 (REACH)
Directive 2011/65/EU (RoHS II + RoHS III)
Directive 2000/53/EG (ELV)

Rated voltage Information and remarks concerning European directives


Nominal voltages are listed in above table and are also standard can be taken from the correspondent information sheet which is
values. The possibility of winding adjustments to other nominal available under Produktinfo.Magnet-Schultz.com.
voltages can get checked on request.
Please make sure that the described devices are suitable for
The devices correspond to protection class III. Electrical equipment your application. Our offers for these devices are based on
of protection class III may be only connected to low voltage systems the assumption of maximal 8 in an FMEA severity table, i. e.
(PELV, SELV)(IEC 60364-4-4-41). in case of malfunction of the device model as offered, there
is, amongst others, no jeopardy of life or limb. Supplementary
Supply availability information concerning its proper installation can be taken
The shown device is a basic device as a basis for customer-specific also from the –Technical Explanation, the effective
developments and designs. Samples and variants on request. DIN VDE0580 as well as the relevant specifications.

This part list is a document for technically qualified personnel.


The present publication is for informational purposes only and shall
not be construed as mandatory illustration of the products unless
otherwise confirmed expressively.

By edition of the present list, all former unit lists lose their validity especially. Illustrations without guarantee – modifications and supply availability reserved

2
Dimensional drawing

Fig. 3: Type G PC P 040 K69 V01 (G013561 Index m)

By edition of the present list, all former unit lists lose their validity especially. Illustrations without guarantee – modifications and supply availability reserved

3
Dimensional drawing

Nennweite
Nominal width

Type Nominal width (mm)


G PC P 040 K69 V03 V03 3.3
G PC P 040 K69 V03 V04 2.8

Fig. 4: Type G PC P 040 K69 V03 / V04 (G013920 Index f)

By edition of the present list, all former unit lists lose their validity especially. Illustrations without guarantee – modifications and supply availability reserved

4
Characteristic curve

Fig. 5: Characteristic curve Type G PC P 040 K69 V01 / V03 / V04 (Reference G013561 Index m)

Installation dimensions (sketch with guide values)

Fig. 6: Connection diagram Type G PC P 040 K69 V01 (G013561 Index m)

By edition of the present list, all former unit lists lose their validity especially. Illustrations without guarantee – modifications and supply availability reserved

5
Fig. 7: Connection diagram Type G PC P 040 K69 V03 / V04 (Reference G013561 Index m)

Type code
Example G PC P 040 K69 V01 Designation Material no.
Type G PC P 12VDC 24VDC
100%ED with 100%ED with
Size 040 HSA HSA
Code for execution K69 V01 Thread
Nominal width G013561004 G013561003
2,8 mm
K69 V03 Flange
Nominal width G013920002 G013920001
3,3 mm
K69 V04 Flange
Nominal width G013945001 G013915002
2,8 mm

Example
Type G PC P 040 K69 V01
Voltage 12 V DC
Operating mode S1 / 100 % / HSA
Material no. 1)
G013561004
1) optional specification