GPCP040 e
GPCP040 e
G PC P 040
Function
zz 2/2 NC
zz Proportional direct-acting
zz Media: H2, N2, air, mixture of H2 and N2
zz Wide proportionality between solenoid current and flow rate
zz Nominal working pressure (NWP) 16 barg
zz Maximum pressure (MAWP) up to 25 barg
zz Low leakage
zz High switching life time
Fig. 1: Type G PC P 040 K69 V01
Construction
zz Compact design
zz Central fastening or flange mounting
zz Protection class according to DIN EN 60529: IP6K9K
if mounted properly and with suitable mating connector
zz Electrical connection via plug TE MCP 2.8 mm
Application examples
zz Fuel gas quantity control in fuel cells
Standards and tests
zz IATF 16949 Fig. 1: Type G PC P 040 K69 V03 / V04
Magnet-Schultz GmbH & Co. KG • Allgäuer Straße 30 • D-87700 Memmingen • Tel. +49 83 31 10 40 • www.magnet-schultz.com
Technical data
G PC P 040 K69 ... V01 / V04 V03
Function 2/2 NC
Operation principle proportional direct acting
Voltage control PWM > 350 Hz
Rated voltage UN (V DC) 12 (9 ... 16) / 24 (18 ... 32)
Rated resistance R20 (Ω) 4.8 / 21.4
Rated current IN (A) 1.6 / 0.8
Limit current IG (A) 1.6 / 0.8
Rated power P20 (W) 12 (1.6 A) / 13.5 (0.8 A)
Inductance (mH) 12.3 (1 kHz, 1 V, 1.6 A)
Isolation class H
Relative duty cycle S1 100% ED (depending on installation space and heat dissipation)
Ambient temperature (°C) -40 ... +100
Protction class IP6K9K
Service life (full stroke, control action) > 3.000.000, > 25.000.000
Nominal width (mm) 2.8 3.3
Kv at IN (m /h)
3
0.23 0.32
Rated operating pressure (NWP) (barg) 16
Maximum input pressure (MAWP) (barg) 25 20
Burst pressure (barg) > 3xMAWP
Circuit diagram
By edition of the present list, all former unit lists lose their validity especially. Illustrations without guarantee – modifications and supply availability reserved
2
Dimensional drawing
By edition of the present list, all former unit lists lose their validity especially. Illustrations without guarantee – modifications and supply availability reserved
3
Dimensional drawing
Nennweite
Nominal width
By edition of the present list, all former unit lists lose their validity especially. Illustrations without guarantee – modifications and supply availability reserved
4
Characteristic curve
Fig. 5: Characteristic curve Type G PC P 040 K69 V01 / V03 / V04 (Reference G013561 Index m)
By edition of the present list, all former unit lists lose their validity especially. Illustrations without guarantee – modifications and supply availability reserved
5
Fig. 7: Connection diagram Type G PC P 040 K69 V03 / V04 (Reference G013561 Index m)
Type code
Example G PC P 040 K69 V01 Designation Material no.
Type G PC P 12VDC 24VDC
100%ED with 100%ED with
Size 040 HSA HSA
Code for execution K69 V01 Thread
Nominal width G013561004 G013561003
2,8 mm
K69 V03 Flange
Nominal width G013920002 G013920001
3,3 mm
K69 V04 Flange
Nominal width G013945001 G013915002
2,8 mm
Example
Type G PC P 040 K69 V01
Voltage 12 V DC
Operating mode S1 / 100 % / HSA
Material no. 1)
G013561004
1) optional specification