PN3000

PN-400-SBR14-MFPKG/US/ /V Pressure sensors


New generation available: PN3070

1: 4-digit alphanumeric display


2: LEDs (display unit / switching status)
3: Programming button

Product characteristics
Combined pressure sensor
Quick disconnect
Function programmable
Process connection: G ¼ I
Switching output, Analog output
4-digit alphanumeric display
Measuring range: 0...400 bar / 0...5800 psi / 0...40 MPa
Application
Application Type of pressure: relative pressure
Liquids and gases
Use in gases at pressures > 25 bar only after contacting the manufacturer ifm
Pressure rating 600 bar 8700 psi 60 MPa
Bursting pressure min. 1000 bar 14500 psi 100 MPa
Medium temperature [°C] -25...80
Electrical data
Electrical design DC PNP
Operating voltage [V] 18...36 DC ¹)
Current consumption [mA] < 50
Insulation resistance [MΩ] > 100 (500 V DC)
Protection class III
Reverse polarity protection yes
Overvoltage protection [V] up to 40 V
Outputs
Output Switching output, Analog output
Output function normally open / closed programmable; 4...20 mA or 0...10 V
Current rating [mA] 250
Voltage drop [V] <2
Short-circuit protection yes (non-latching)
PN3000
PN-400-SBR14-MFPKG/US/ /V Pressure sensors

Switching frequency [Hz] ≤ 170


Analog output 4...20 mA / 0...10 V
Max. load [Ω] 4...20 mA: max. 500 / 0...10 V: min. 2000
Measuring / setting range
Measuring range 0...400 bar 0...5800 psi 0...40 MPa
Setting range
Set point, SP 4...400 bar 60...5790 psi 0.4...40.0 MPa
Reset point, rP 2...398 bar 30...5760 psi 0.2...39.8 MPa
in steps of 2 bar 30 psi 0.2 MPa
Factory setting SP1 = 100 bar; rP1 = 92 bar
Accuracy / deviations
Accuracy / deviations
(in % of the span)
Switch point accuracy < ± 0.5
Characteristics deviation *) < ± 0.25 (BFSL) / < ± 0.5 (LS)
Hysteresis < ± 0.25
Repeatability **) < ± 0.1
Long-term stability ***) < ± 0.05
Temperature coefficients (TEMPCO) in the temperature range 0...80° C (in % of the span per 10 K)
Greatest TEMPCO of the zero point 0.2
Greatest TEMPCO of the span 0.2
Reaction times
Power-on delay time [s] 0.3
Delay time programmable dS, dr [s] 0; 0.2...50
Response time analog output [ms] <3
Integrated watchdog yes
Software / programming
Programming options hysteresis / window function; N.O. / N.C; on delay, off delay; damping; display unit;
current / voltage output
Environment
Ambient temperature [°C] -20...80
Storage temperature [°C] -40...100
Protection IP 67
Tests / approvals
EMC EN 61000-4-2 ESD: 4 kV CD / 8 kV AD
EN 61000-4-3 HF radiated: 10 V/m
EN 61000-4-4 Burst: 2 kV
EN 61000-4-5 Surge: 0.5/1 kV
EN 61000-4-6 HF conducted: 10 V
Shock resistance DIN IEC 68-2-27: 50 g (11 ms)
Vibration resistance DIN IEC 68-2-6: 20 g (10...2000 Hz)
MTTF [Years] 213
Mechanical data
Process connection G¼I
Materials (wetted parts) stainless steel (303S22); ceramics; FPM (Viton)
Housing materials stainless steel (304S15); stainless steel 316L / 1.4404; PC (Makrolon); PBT (Pocan);
PEI; FPM (Viton); EPDM/X (Santoprene)
PN3000
PN-400-SBR14-MFPKG/US/ /V Pressure sensors

Switching cycles min. 100 million


Weight [kg] 0.273
Displays / operating elements
Display Display unit 3 x LED green
Switching status LED yellow
Function display 4-digit alphanumeric display
Measured values 4-digit alphanumeric display
Electrical connection
Connection M12 connector; gold-plated contacts
Wiring

Remarks
Remarks ¹) to EN50178, SELV, PELV
*) BFSL = Best Fit Straight Line / LS = Limit Value Setting
**) with temperature fluctuations < 10 K
***) in % of value of measuring range / 6 months
Pack quantity [piece] 1