Local regulations may restrict the use of this product to below the conditions quoted.

In the interests of development and improvement of the product, we reserve the right to change the specification without notice. © Copyright 2016

TI-P198-04
MI Issue 2

RIM20
Rotor Insertion Flowmeter
Description
The RIM20 multivariable insertion turbine flowmeter utilizes three primary sensing elements to measure the mass flowrate of steam,
liquids and gases:

- Turbine velocity sensor, - RTD temperature sensor, - Solid-state pressure transducer.

Principle of operation
Insertion turbine flowmeters measure flow of liquid, gas, and steam by
detecting the frequency of rotation of the turbine blades. According to the
proven laws of physics, the frequency at which the turbine rotates is directly
proportional to the flow velocity.
Insertion turbine flowmeters measure flow by detecting the local velocity at
a strategically located position within the pipe. The RIM20 detects the
frequency within the sensor head. It uses the local velocity, along with other
parameters such as fluid type, pipe size, and Reynolds Number to calculate
the average pipe velocity, and consequently, the volumetric flowrate.

RIM20 range and benefits


The RIM20-V delivers a direct reading of volumetric flowrate, generally
the most cost-effective solution for liquid flow monitoring, in applications
ranging from general water flows to hydrocarbon fuel flow measurement.

The RIM20-VT integrates a precision 1 000 Ω platinum RTD temperature


sensor that can be used to calculate and output a compensated mass reading.
This device is typically used to measure flowrates of saturated steam.

The RIM20-VTP offers you flow computer functionality in a compact field


device. This multivariable instrument incorporates temperature and pressure
sensors to provide an instantaneous reading of the compensated mass
flowrate of gases, liquids and steam. In addition to outputs for totalized mass
and alarm settings, the field-configurable electronics deliver up to three
analogue 4 - 20 mA outputs of five process measurements, including
volumetric flowrate, mass flowrate, pressure, temperature and density.

The RIM20-EM Energy Monitoring option permits real-time calculation


of energy consumption for a facility or process. The flowmeter can be
programmed to measure steam, hot water or chilled water. The RIM20-VTP
flowmeter monitors one side of the process, either sent or returned, and
uses the input from a second separate temperature sensor on the opposite
leg of the process to calculate the change in energy. Selectable energy
units include BTUs, joules, calories, Watt-hours, Megawatt-hours and
Horsepower-hours. The local or remote electronics indicate t wo
temperatures, delta T, mass total and energy total.

Compliance
- Electromagnetic Compatibility Directive
- Low Voltage Directive

Sizes Turbine
Insertion style mounting permits installation in any pipe DN50 (2") and greater. blades

Page 1 of 10
Technical data
316L, 302, and 17-4PH, and 18-8 stainless steel, tungsten carbide, sapphire, plus:
• DuPont Teflon ® based thread sealant on models with pressure transducer
Wetted materials
• DuPont Teflon ® packing on standard temperature models with packing gland
• Graphite based packing on high temperature models with packing gland

Any gas, liquid or steam compatible with 316L stainless steel and other listed
Application
wetted materials. Not recommended for multi-phase fluids

S option - Standard -55 °C to +232 °C (-67 °F to +450 °F)


Temperature Process
H option - High -267 °C to +454 °C (-448 °F to +850 °F)

Operating -40 °C to +60 °C (-40 °F to +140 °F)


Temperature Ambient
Storage -40 °C to +85 °C (-40 °F to +185 °F)

Electrical Safety EN61010-1:2010

LVD Overvoltage Category II


Environmental
Pollution Degree 2

Emissions Group 1, Class A (Suitable for Industrial Environments only)


EMC
Immunity Suitable for Industrial Environments

Enclosure NEMA 4X, IP66

Full-scale operating pressure Maximum over-range pressure

2 bar a 30 psi a 4 bar a 60 psi a

7 bar a 100 psi a 14 bar a 200 psi a


Pressure transducer
ratings
20 bar a 300 psi a 41 bar a 600 psi a

34 bar a 500 psi a 69 bar a 1 000 psi a

100 bar a 1 500 psi a 175 bar a 2 500 psi a

Style connection Connection / Rating

2" Male NPT ASME Class 600

2" ASME B16.5 Class 150 or DN50 EN1092-1 PN16


Compression fitting
2" ASME B16.5 Class 300 or DN50 EN1092-1 PN40

2" ASME B16.5 Class 600 or DN50 EN1092-1 PN63

2" Male NPT ASME Class 300


Pressure ratings
Packing gland 2" ASME B16.5 Class 150 or DN50 EN1092-1 PN16

2" ASME B16.5 Class 300 or DN50 EN1092-1 PN40

2" Male NPT ASME Class 600

Packing gland 2" ASME B16.5 Class 150 or DN50 EN1092-1 PN16
and
Permanent retractor 2" ASME B16.5 Class 300 or DN50 EN1092-1 PN40

2" ASME B16.5 Class 600 or DN50 EN1092-1 PN63

DL option - 12 to 36 Vdc, 25 mA, 1 W maximum, Loop powered (single output)

Power requirements DH option - 12 to 36 Vdc, 300 mA, 9 W maximum, (multiple outputs)

AC option - 100 to 240 Vac, 50 / 60 Hz line power, 5 W maximum (multiple outputs)

Page 2 of 10 TI-P198-04 MI Issue 2

RIM20 Rotor Insertion Flowmeter


Alphanumeric 2 line x 16 character LCD digital display

Six pushbuttons for full field configuration


Display
Pushbuttons can be operated with magnetic wand without removal of the enclosure covers

Display can be mounted in 90° intervals for better viewing

Analogue 4 - 20 mA

Alarm Solid state relay, 40 Vdc

Totalizer pulse 50 millisecond pulse, 40 Vdc


Output signals
Volumetric or Loop powered mass One analogue, one totalizer pulse, HART®, scaled frequncy output

Up to three analogue signals, three alarms, one totalizer


Multivariable option 1
pulse, HART®, scaled frequency output

Multivariable option 2 Modus RTU or BACnet MS / TP compatible process monitoring

Performance specifications
Accuracy Mass flowrate accuracy for gas and steam based on 50 - 100% of pressure range

Process variables Liquids Gas and steam Repeatability Stability over 12 months

Volumetric flowrate ± 1.2% of rate ± 1.5% of rate ± 0.1% of rate ± Negligible

Mass flowrate ± 1.5% of rate ± 2.0% of rate ± 0.2% of rate ± 0.2% of rate

Temperature ± 1.0 °C (± 2.0 °F) ± 1.0 °C (± 2.0 °F) ± 1.0 °C (± 2.0 °F) ± 0.5 °C (± 0.9 °F)

Pressure ± 0.3% of full-scale ± 0.3% of full-scale ± 0.05% of full-scale ± 0.1% of full-scale

Density ± 0.3% of reading ± 0.5% of reading ± 0.1% of reading ± 0.1% of reading

Response time Adjustable from 1 to 100 seconds

TI-P198-04 MI Issue 2 Page 3 of 10

RIM20 Rotor Insertion Flowmeter


Dimensions and weights (approximate) in mm and inches
Compression fitting models Weight (approximate) in kg and lbs
127 mm C S E
(5")
135 mm 81 mm
kg lbs kg lbs kg lbs
(5.31") (3.19")
CNPT 5.7 13 6.2 14 6.7 15
¾" NPT conduit entry
C150, C16 6.8 15 7.3 16 7.8 17
Electronics enclosure
C300, C40 7.8 17 8.3 18 8.8 19

Pressure transducer housing C600, C63 8.2 18 8.7 19 9.2 20


(not present on RIM20 V, VT)
Add 5 kg (11 lb) for remote electronics
Orientation Lever

102 mm
(4")

Compression fitting
2" male NPT
2", DN50 mounting flange

Stem
B

Turbine sensor head

C150 CNPT
C16
C300
C40
C600
Dimensions (approximate) in mm and inches C63

C S E
Compact Length Standard Length Extended Length
RIM20 V and VT A B (max) A B (max) A B (max)

mm inches mm inches mm inches mm inches mm inches mm inches

Compression fitting, Male NPT 536 21.1 229 9.0 953 37.5 645 25.4 1 257 49.5 950 37.4

Compression fitting, 150 Ib, PN16 536 21.1 257 10.1 953 37.5 673 26.5 1 257 49.5 978 38.5

Compression fitting, 300 Ib, PN40 536 21.1 254 10.0 953 37.5 671 26.4 1 257 49.5 975 38.4

Compression fitting, 600 Ib, PN63 536 21.1 244 9.6 953 37.5 660 26.0 1 257 49.5 965 38.0

C S E
Compact Length Standard Length Extended Length
RIM20 VTP A B (max) A B (max) A B (max)

mm inches mm inches mm inches mm inches mm inches mm inches

Compression fitting, Male NPT 612 24.1 229 9.0 1 029 40.5 645 25.4 1 334 52.5 950 37.4

Compression fitting, 150 Ib, PN16 612 24.1 257 10.1 1 029 40.5 673 26.5 1 334 52.5 978 38.5

Compression fitting, 300 Ib, PN40 612 24.1 254 10.0 1 029 40.5 671 26.4 1 334 52.5 975 38.4

Compression fitting, 600 Ib, PN63 612 24.1 244 9.6 1 029 40.5 660 26.0 1 334 52.5 965 38.0

Page 4 of 10 TI-P198-04 MI Issue 2

RIM20 Rotor Insertion Flowmeter


Dimensions and weights (approximate) in mm and inches
Packing gland models - Please note that a removable retractor can be used with these models
203 mm
(8")
135 mm 81 mm
(5.31") (3.19")

¾" NPT conduit entry


Weight (approximate) in kg and lbs

Electronics enclosure
S E
kg lbs kg lbs
Pressure transducer housing
(not present on RIM20 V, VT) PNPT 7.1 16 7.6 17
Orientation Lever P150, P16 9.4 21 9.9 22
P300, P40 11.3 25 11 .8 26

Add 5 kg (11 lb) for remote electronics

Stem
A

Stem clamp
Packing gland

2" male NPT


2", DN50 mounting flange
B

Turbine sensor head


P150 PNPT
P300
P16
P40

Dimensions (approximate) in mm and inches


S E
RIM20 Standard Length Extended Length

V, VT and VTP
A B (max) A B (max)

mm inches mm inches mm inches mm inches


Packing gland, Male NPT 1 016 40.0 526 20.7 1321 52.0 831 32.7
Packing gland, 150 Ib, PN16
1 016 40.0 516 20.3 1321 52.0 820 32.3
Packing gland, 300 Ib PN40

TI-P198-04 MI Issue 2 Page 5 of 10

RIM20 Rotor Insertion Flowmeter


Dimensions and weights (approximate) in mm and inches
Packing gland models with permanent retractor
203 mm 203 mm
(8") (8")
135 mm 81 mm
(5.31") (3.19")

¾" NPT conduit entry Weight (approximate) in kg and lbs


Electronics S E
enclosure
kg lbs kg lbs
Pressure transducer
housing (not present PNPTR 11.5 25 14.5 32
on RIM20 V, VT)
P150R, P16R 13.7 30 16.7 37
Orientation lever P300R, P40R 15.5 34 18.5 41
P600R, P63R 16.0 35 19.0 42

Add 5 kg (11 lb) for remote electronics


Retractor
A

Stem

Packing gland
Retractor
handle
2" male NPT
2", DN50 mounting flange
B

Turbine
sensor P150R PNPTR
head P300R
P600R
P16R
P40R
P63R
Dimensions (approximate) in mm and inches

RIM20 S
Standard Length
E
Extended Length

V, VT and VTP A B (max) A B (max)

with permanent retractor mm inches mm inches mm inches mm inches


Packing gland, Male NPT 1 016 40.0 526 20.7 1321 52.0 831 32.7
Packing gland, 150 Ib, PN16
Packing gland, 300 Ib, PN40 1 016 40.0 516 20.3 1321 52.0 820 32.3
Packing gland, 600 Ib, PN63

Remote 81 mm
(3.19") 127 mm 216 mm
electronics (5") (8.5")
53 mm
option (2.1")
145 mm
(5.7")
Remote cable
15 metres (50 ft)
8 mm
(0.315")

'U' bolt 76 mm
provided (3")

127 mm 12.7 mm
(5") (0.5")
76 mm
Remote electronics option available on all models (3")

Page 6 of 10 TI-P198-04 MI Issue 2

RIM20 Rotor Insertion Flowmeter


Typical Metric flowrates
Saturated steam (kg / h)
Nominal pipe size
Rotor Pressure
80 mm 150 mm 200 mm 300 mm 400 mm 600 mm
Minimum 17 72 127 297 491 1 219
1.4 bar g
Maximum 225 929 1 642 3 817 6 270 15 367

R40
Minimum 42 173 306 713 1 176 2 907
5 bar g
Maximum 537 2 216 3 915 9 090 14  905 36 400
Minimum 75 310 549 1 279 2 106 5 194
10 bar g
Maximum 962 3 963 6 999 16 239 26 600 64 815
Minimum 20 82 146 341 563 1 396
1.4 bar g
Maximum 329 1 358 2 399 5 575 9 149 22 384

R30
Minimum 48 198 350 817 1 347 3 328
5 bar g
Maximum 785 3 237 5 716 13 265 21 735 52 993
Minimum 86 355 629 1 465 2 411 5 943
10 bar g
Maximum 1 405 5 786 10 215 23 687 38 771 94 337
Minimum 35 146 259 604 995 2 463
1.4 bar g
Maximum 530 2 187 3 863 8 968 14 704 35 898

R20
Minimum 85 350 620 1 444 2 377 5 856
5 bar g
Maximum 1 265 5 207 9 194 21 322 34 903 84 940
Minimum 152 628 1 111 2 586 4 252 10 448
10 bar g
Maximum 2 261 9 303 16 419 38 049 62 227 151 156
Minimum 61 253 448 1 045 1 721 4 247
1.4 bar g
Maximum 1 098 4 522 7 985 18 520 30 320 73 805

R10
Minimum 147 606 1 072 2 496 4 103 10 082
5 bar g
Maximum 2 615 10 755 18 979 43 967 71 883 174 497
Minimum 263 1 087 1 921 4 466 7 335 17 975
10 bar g
Maximum 4 672 19 197 33 862 78 386 128 050 310 382

Air (nm3 / h) at 20 °C
Nominal pipe size
Rotor Pressure
80 mm 150 mm 200 mm 300 mm 400 mm 600 mm
Minimum 12 49 87 204 337 838
1.4 bar g
Maximum 154 639 1 130 2 628 4 320 10 607

R40
Minimum 74 305 540 1 259 2 072 5 107
5 bar g
Maximum 946 3 898 6 884 15 969 26 152 63 694
Minimum 137 567 1 002 2 332 3 835 9 423
10 bar g
Maximum 1 751 7 205 12 718 29 476 48 216 117 169
Minimum 14 56 100 234 386 960
1.4 bar g
Maximum 226 934 1 651 3 839 6 306 15 455

R30
Minimum 84 350 619 1 441 2 373 5 844
5 bar g
Maximum 1 382 5 690 10 046 23 290 38 115 92 698
Minimum 157 649 1 148 2 671 4 390 10 779
10 bar g
Maximum 2 556 10 511 18 548 42 965 70 237 170 473
Minimum 24 100 178 415 684 1 696
1.4 bar g
Maximum 365 1 505 2 660 6 179 10 139 24 794

R20
Minimum 150 618 1 094 2 544 4 182 10 271
5 bar g
Maximum 2 224 9 149 16 145 37 407 61 166 148 520
Minimum 278 1 146 2 026 4 709 7 731 18 929
10 bar g
Maximum 4 110 16 888 29 789 68 956 112 643 273 032
Minimum 42 174 308 718 1 184 2 927
1.4 bar g
Maximum 756 3 115 5 502 12 768 20 919 50 995

R10
Minimum 259 1 069 1 890 4 393 7 214 17 668
5 bar g
Maximum 4 595 18 874 33 290 77 048 125 842 304 938
Minimum 480 1 980 3 499 8 125 13 323 32 541
10 bar g
Maximum 8 481 34 799 61 349 141 871 231 535 560 318

TI-P198-04 MI Issue 2 Page 7 of 10

RIM20 Rotor Insertion Flowmeter


Typical Imperial flowrates
Saturated steam (lb / h)
Nominal pipe size
Rotor Pressure
3" 6" 8" 12" 16" 24"
Minimum 22 91 162 378 625 1 555
5 psi g
Maximum 287 1 187 2 098 4 883 8 029 19 727

R40
Minimum 119 496 878 2 046 3 371 8 328
100 psi g
Maximum 1 540 6 350 11 216 26 034 42 668 104 092
Minimum 220 913 1 615 3 761 6 191 15 249
200 psi g
Maximum 2 827 11 643 20 558 47 681 78 064 190 027
Minimum 25 105 186 434 717 1 782
5 psi g
Maximum 420 1 735 3 068 7 135 11 721 28 745

R30
Minimum 137 568 1 006 2 344 3 861 9 530
100 psi g
Maximum 2 251 9 272 16 373 37 984 62 207 151 526
Minimum 253 1 046 1 850 4 308 7 088 17 446
200 psi g
Maximum 4 129 16 994 29 996 69 532 113 761 276 542
Minimum 45 186 330 770 1 270 3 150
5 psi g
Maximum 677 2 797 4 943 11 485 18 849 46 119

R20
Minimum 243 1 005 1 778 4 140 6 811 16 762
100 psi g
Maximum 3 623 14 915 26 328 61 035 99 870 242 834
Minimum 447 1 848 3 268 7 601 12 492 30 657
200 psi g
Maximum 6 643 27 317 48 203 111 658 182 535 443 035
Minimum 78 323 572 1 334 2 199 5 440
5 psi g
Maximum 1 405 5 790 10 227 23 736 38 897 94 870

R10
Minimum 421 1 739 3 075 7 153 11 755 28 849
100 psi g
Maximum 7 490 30 791 54 325 125 807 205 605 498 759
Minimum 774 3 195 5 647 13 123 21 541 52 728
200 psi g
Maximum 13 719 56 341 99 362 229 926 375 467 909 528

Air (SCFM) at 70 °F
Nominal pipe size
Rotor Pressure
3" 6" 8" 12" 16" 24"
Minimum 7 31 55 129 213 529
5 psi g
Maximum 98 404 714 1 660 2 729 6 702

R40
Minimum 62 255 451 1 051 1 730 4 257
100 psi g
Maximum 790 3 252 5 741 13 313 21 791 53 019
Minimum 117 484 857 1 992 3 273 8 031
200 psi g
Maximum 1 494 6 146 10 846 25 128 41 083 99 739
Minimum 9 36 63 148 244 606
5 psi g
Maximum 143 590 1 043 2 426 3 984 9 765

R30
Minimum 71 292 517 1 204 1 980 4 871
100 psi g
Maximum 1 153 4 746 8 376 19 412 31 753 77 152
Minimum 134 555 981 2 281 3 747 9 186
200 psi g
Maximum 2 181 8 964 15 814 36 617 59 832 145 094
Minimum 15 63 112 262 432 1 071
5 psi g
Maximum 230 951 1 680 3 904 6 406 15 665

R20
Minimum 125 517 913 2 124 3 489 8 557
100 psi g
Maximum 1 855 7 628 13 458 31 168 50 942 123 591
Minimum 237 979 1 730 4 020 6 595 16 126
200 psi g
Maximum 3 506 14 397 25 389 58 747 95 927 232 348
Minimum 26 110 195 454 748 1 849
5 psi g
Maximum 478 1 968 3 476 8 067 13 217 32 219

R10
Minimum 216 893 1 578 3 666 6 016 14 715
100 psi g
Maximum 3 831 15 728 27 734 64 166 104 762 253 698
Minimum 410 1 691 2 987 6 933 11 362 27 714
200 psi g
Maximum 7 230 29 650 52 259 120 804 197 092 476 732

Page 8 of 10 TI-P198-04 MI Issue 2

RIM20 Rotor Insertion Flowmeter


Water flowrates
m3 / hr GPM
Size
Minimum Maximum Minimum Maximum
50 mm 2" 1.19 71.3 5 314
80 mm 3" 2.62 157 12 691
150 mm 6" 12.30 614 54 2 701
Nominal pipe
200 mm 8" 24.80 1 062 109 4 678
size
300 mm 12" 56.00 2 402 247 10 575
400 mm 16" 87.60 3 753 386 16 524
600 mm 24" 199.00 8 538 877 37 590

Sizing considerations
Straight run piping requirements Upstream Downstream
One 90° elbow before the flowmeter 10 D 5D
Two 90° elbows before the flowmeter 15 D 5D
Two 90° elbows out of plane before the flowmeter 30 D 5D
Piping conditions
Reduction before the flowmeter 10 D 5D
Expansion before the flowmeter 20 D 5D
Partially open valve 30 D 5D
D = Internal diameter of the pipe - If there is not a sufficient straight run of pipe, a flow
rectifier may be used to reduce the above diameter measurements.
Consult your local Spirax Sarco representative or the factory for your specific application.
Maximum 9 metres / second (30 feet / second)
Liquid
Minimum 0.15 metres / second (0.5 feet / second)
Velocity range
Maximum 13 to 62 metres / second (43 to 205 feet / second) depending on rotor pitch
Gas or steam
Minimum 1 to 3.7 metres / second (3.5 to 12 feet / second) depending on rotor pitch

Other installation considerations:


- Mounting position
The RIM20 may be installed in vertical, horizontal, or angled pipe sections. The flowmeter is attached perpendicular to the axis of
the pipe and should not be mounted 'upside-down' (with its top section hanging below the pipe mount). For liquid service, the fluid
must completely fill the pipe.
- Site selection
The flow measurement location should be selected to minimize turbulence and swirl. The extent of these flow disturbances depends
upon the piping configuration. Valves, elbows, pumps, and other piping components may add disturbances to the flow.
- Hot-tap compatibility
With the removable or permanent retractor assembly the RIM20 is ‘hot-tappable’ and can be installed and removed without shutting
down the process. An isolation valve with a pipe mounting kit is used to isolate the flowmeter from the process.

Accessories
Removable retractor
For models without a permanent retractor, one removable retractor must be used if the process pressure is >3.4 bar g (50 psi g).
Removable retractor
Removable retractor options
Extended length removable retractor – For use with extended length probes

How to order example: 1 off Spirax Sarco RIM20 - Removable retractor.

Replacement rotors
Rotor assembly, liquid, 40° pitch L40
Rotor assembly, steam/gas, 10° pitch R10
Rotor assembly, steam/gas, 15° pitch R15
Rotor spares Rotor assembly, steam/gas, 20° pitch R20
Rotor assembly, steam/gas, 25° pitch R25
Rotor assembly, steam/gas, 30° pitch R30
Rotor assembly, steam/gas, 40° pitch R40

How to order example: 1 off Spirax Sarco RIM20 - L40 – Rotor Assembly.

TI-P198-04 MI Issue 2 Page 9 of 10

RIM20 Rotor Insertion Flowmeter


How to order Selection:
Grey =
Category Description Suffix code
Standard
Flowmeter Insertion multivariable mass turbine flowmeter RIM20 RIM20
Volumetric flowmeter for liquid, gas and steam V
Velocity and temperature sensors VT
Velocity, temperature and pressure sensors VTP
Velocity, temperature and external 4 - 20 mA pressure input VTEP
Electronics Velocity, external RTD temperature input, external 4 - 20 mA pressure input VETEP V
Energy output options VTEM
Energy options with pressure sensor VTPEM
Energy options, velocity, temperature and external 4 - 20 mA pressure input VTEPEM
Energy options, velocity, external RTD temperature input, external 4 - 20 mA pressure input VETEPEM
Standard length S
Probe
length
Compact length - Only available for compression fitting connections CNPT, C150, C300, C600, C16, C40 and C63 C S
Extended length E
Local mount NEMA 4X, IP66 Enclosure L
Remote electronics NEMA 4X, IP66 25' cable with display - (not suitable for ATEX / IECEx) R25
Electronics 25' (7.6 m) armored cable with glands 'V' flowmeter only A25
enclosure 25' (7.6 m) armored cable with glands 'VT', 'VTP' flowmeter only A25P L
mounting Remote electronics NEMA 4X, IP66 50' cable with display - (not suitable for ATEX / IECEx) R50
50' (15.2 m) armored cable with glands 'V' flowmeter only A50
50' (15.2 m) armored cable with glands 'VT', 'VTP' flowmeter only A50P
Display Digital display and programming buttons D D
12 - 36 Vdc, 25 mA, 1 W maximum required on loop powered flowmeters, 1HL only DL
Power supply 12 - 36 Vdc, 300 mA, 9 W maximum - use with 1H, 1M, 1B, 3H, 3M, 3B DH DL
100 - 240 Vac, 50 / 60 Hz line power, 5 W maximum - use with 1H, 1M, 1B, 3H, 3M, 3B AC
Loop powered option - one analogue output (4 - 20 mA), one alarm, one pulse, HART ®, DL input power only 1HL
One analogue output (4 - 20 mA), one alarm, one pulse, HART ® communication protocol, DH or AC option only 1H
Output signal
One analogue output (4 - 20 mA), one alarm, one pulse, MODBUS communication protocol, DH or AC option only 1M
Inclusive of the One analogue output (4 - 20 mA), one alarm, one pulse, BACnet communication protocol, DH or AC option only 1B 1HL
scaled frequency
Three analogue outputs (4 - 20 mA), three alarms, one pulse, HART ® ('VT', 'VTP' only), DH or AC option only 3H
output
Three analogue outputs (4 - 20 mA), three alarms, one pulse, MODBUS ('VT', 'VTP' only), DH or AC option only 3M
Three analogue outputs (4 - 20 mA), three alarms, one pulse, BACnet ('VT', 'VTP' only), DH or AC option only 3B
Process Standard temperature Process temperature -55 °C to 232 °C -67 °F to 450 °F S
temperature High temperature Process temperature -267 °C to 454 °C -448 °F to 850 °F
S
H
No pressure sensor P0
Maximum 2 bar a 30 psi a Proof 4 bar a 60 psi a P1
Pressure Maximum 7 bar a 100 psi a Proof 14 bar a 200 psi a P2
P0
sensor Maximum 20 bar a 300 psi a Proof 41 bar a 600 psi a P3
Maximum 34 bar a 500 psi a Proof 69 bar a 1 000 psi a P4
Maximum 100 bar a 1 500 psi a Proof 175 bar a 2 500 psi a P5
Compression, 2" NPT CNPT Packing gland, 2" NPT, retractor (use with E probe) PNPTR-E
Compression, 2" ASME 150 flange C150 Packing gland, 2" ASME 150 flange, retractor P150R
Compression, DN50 PN16 flange C16 Packing gland, 2" ASME 150 flange, retractor (E probe) P150R-E
Compression, 2" ASME 300 flange C300 Packing gland, DN50 PN16 flange, retractor P16R
Compression, DN50 PN40 flange C40 Packing gland, DN50 PN16 flange, retractor (E probe) P16R-E
Compression, 2" ASME 600 flange C600 Packing gland, 2" ASME 300 flange, retractor P300R
Process Compression, DN50 PN63 flange C63 Packing gland, 2" ASME 300 flange, retractor (E probe) P300R-E
connections Packing gland*, 2" NPT
PNPTR
PNPT Packing gland, DN50 PN40 flange, retractor P40R
Packing gland*, 2" ASME 150 flange P150 Packing gland, DN50 PN40 flange, retractor (E probe) P40R-E
Packing gland*, DN50 PN16 flange P16 Packing gland, 2" ASME 600 flange, retractor P600R
Packing gland*, 2" ASME 300 flange P300 Packing gland, 2" ASME 600 flange, retractor (E probe) P600R-E
Packing gland*, DN50 PN40 flange P40 Packing gland, DN50 PN63 flange, retractor P63R
Packing gland, 2" NPT, retractor PNPTR Packing gland, DN50 PN63 flange, retractor (E probe) P63R-E
* One removable retractor must be ordered if the process pressure is >3.4 bar g (50 psi g).
Conformity CE marked only S S
Gas or Steam Vmin = 1.07 m / s (3.5 ft / sec) Vmax = 13.1 m / s (43 ft / sec) 40° pitch R40
Gas or Steam Vmin = 1.2 m / s (4.0 ft / sec) Vmax = 19.0 m / s (62.5 ft / sec) 30° pitch R30
Gas or Steam Vmin = 1.5 m / s (5.0 ft / sec) Vmax = 24.4 m / s (80 ft / sec) 25° pitch R25
Rotor options Gas or Steam Vmin = 2.1 m / s (7.0 ft / sec) Vmax = 30.5 m / s (100 ft / sec) 20° pitch R20 R40
Gas or Steam Vmin = 2.6 m / s (8.5 ft / sec) Vmax = 41.0 m / s (134.6 ft / sec) 15° pitch R15
Gas or Steam Vmin = 3.7 m / s (12.0 ft / sec) Vmax = 62.5 m / s (205 ft / sec) 10° pitch R10
Liquid Vmin = 0.3 m / s (1.0 ft / sec) Vmax = 9.1 m / s (30 ft / sec) 40° pitch L40

Selection example: RIM20 - V - S - L - D - DL - 1HL - S - P0 - PNPTR - S - R40

How to order example: 1 off Spirax Sarco RIM20 - V - S - L - D - DL -1HL - S - P0 - PNPTR - S -R40 rotor insertion flowmeter.

Page 10 of 10 TI-P198-04 MI Issue 2

RIM20 Rotor Insertion Flowmeter