RIM20
RIM20
In the interests of development and improvement of the product, we reserve the right to change the specification without notice. © Copyright 2016
TI-P198-04
MI Issue 2
RIM20
Rotor Insertion Flowmeter
Description
The RIM20 multivariable insertion turbine flowmeter utilizes three primary sensing elements to measure the mass flowrate of steam,
liquids and gases:
Principle of operation
Insertion turbine flowmeters measure flow of liquid, gas, and steam by
detecting the frequency of rotation of the turbine blades. According to the
proven laws of physics, the frequency at which the turbine rotates is directly
proportional to the flow velocity.
Insertion turbine flowmeters measure flow by detecting the local velocity at
a strategically located position within the pipe. The RIM20 detects the
frequency within the sensor head. It uses the local velocity, along with other
parameters such as fluid type, pipe size, and Reynolds Number to calculate
the average pipe velocity, and consequently, the volumetric flowrate.
Compliance
- Electromagnetic Compatibility Directive
- Low Voltage Directive
Sizes Turbine
Insertion style mounting permits installation in any pipe DN50 (2") and greater. blades
Page 1 of 10
Technical data
316L, 302, and 17-4PH, and 18-8 stainless steel, tungsten carbide, sapphire, plus:
• DuPont Teflon ® based thread sealant on models with pressure transducer
Wetted materials
• DuPont Teflon ® packing on standard temperature models with packing gland
• Graphite based packing on high temperature models with packing gland
Any gas, liquid or steam compatible with 316L stainless steel and other listed
Application
wetted materials. Not recommended for multi-phase fluids
Packing gland 2" ASME B16.5 Class 150 or DN50 EN1092-1 PN16
and
Permanent retractor 2" ASME B16.5 Class 300 or DN50 EN1092-1 PN40
Analogue 4 - 20 mA
Performance specifications
Accuracy Mass flowrate accuracy for gas and steam based on 50 - 100% of pressure range
Process variables Liquids Gas and steam Repeatability Stability over 12 months
Mass flowrate ± 1.5% of rate ± 2.0% of rate ± 0.2% of rate ± 0.2% of rate
Temperature ± 1.0 °C (± 2.0 °F) ± 1.0 °C (± 2.0 °F) ± 1.0 °C (± 2.0 °F) ± 0.5 °C (± 0.9 °F)
102 mm
(4")
Compression fitting
2" male NPT
2", DN50 mounting flange
Stem
B
C150 CNPT
C16
C300
C40
C600
Dimensions (approximate) in mm and inches C63
C S E
Compact Length Standard Length Extended Length
RIM20 V and VT A B (max) A B (max) A B (max)
Compression fitting, Male NPT 536 21.1 229 9.0 953 37.5 645 25.4 1 257 49.5 950 37.4
Compression fitting, 150 Ib, PN16 536 21.1 257 10.1 953 37.5 673 26.5 1 257 49.5 978 38.5
Compression fitting, 300 Ib, PN40 536 21.1 254 10.0 953 37.5 671 26.4 1 257 49.5 975 38.4
Compression fitting, 600 Ib, PN63 536 21.1 244 9.6 953 37.5 660 26.0 1 257 49.5 965 38.0
C S E
Compact Length Standard Length Extended Length
RIM20 VTP A B (max) A B (max) A B (max)
Compression fitting, Male NPT 612 24.1 229 9.0 1 029 40.5 645 25.4 1 334 52.5 950 37.4
Compression fitting, 150 Ib, PN16 612 24.1 257 10.1 1 029 40.5 673 26.5 1 334 52.5 978 38.5
Compression fitting, 300 Ib, PN40 612 24.1 254 10.0 1 029 40.5 671 26.4 1 334 52.5 975 38.4
Compression fitting, 600 Ib, PN63 612 24.1 244 9.6 1 029 40.5 660 26.0 1 334 52.5 965 38.0
Electronics enclosure
S E
kg lbs kg lbs
Pressure transducer housing
(not present on RIM20 V, VT) PNPT 7.1 16 7.6 17
Orientation Lever P150, P16 9.4 21 9.9 22
P300, P40 11.3 25 11 .8 26
Stem
A
Stem clamp
Packing gland
V, VT and VTP
A B (max) A B (max)
Stem
Packing gland
Retractor
handle
2" male NPT
2", DN50 mounting flange
B
Turbine
sensor P150R PNPTR
head P300R
P600R
P16R
P40R
P63R
Dimensions (approximate) in mm and inches
RIM20 S
Standard Length
E
Extended Length
Remote 81 mm
(3.19") 127 mm 216 mm
electronics (5") (8.5")
53 mm
option (2.1")
145 mm
(5.7")
Remote cable
15 metres (50 ft)
8 mm
(0.315")
'U' bolt 76 mm
provided (3")
127 mm 12.7 mm
(5") (0.5")
76 mm
Remote electronics option available on all models (3")
R40
Minimum 42 173 306 713 1 176 2 907
5 bar g
Maximum 537 2 216 3 915 9 090 14 905 36 400
Minimum 75 310 549 1 279 2 106 5 194
10 bar g
Maximum 962 3 963 6 999 16 239 26 600 64 815
Minimum 20 82 146 341 563 1 396
1.4 bar g
Maximum 329 1 358 2 399 5 575 9 149 22 384
R30
Minimum 48 198 350 817 1 347 3 328
5 bar g
Maximum 785 3 237 5 716 13 265 21 735 52 993
Minimum 86 355 629 1 465 2 411 5 943
10 bar g
Maximum 1 405 5 786 10 215 23 687 38 771 94 337
Minimum 35 146 259 604 995 2 463
1.4 bar g
Maximum 530 2 187 3 863 8 968 14 704 35 898
R20
Minimum 85 350 620 1 444 2 377 5 856
5 bar g
Maximum 1 265 5 207 9 194 21 322 34 903 84 940
Minimum 152 628 1 111 2 586 4 252 10 448
10 bar g
Maximum 2 261 9 303 16 419 38 049 62 227 151 156
Minimum 61 253 448 1 045 1 721 4 247
1.4 bar g
Maximum 1 098 4 522 7 985 18 520 30 320 73 805
R10
Minimum 147 606 1 072 2 496 4 103 10 082
5 bar g
Maximum 2 615 10 755 18 979 43 967 71 883 174 497
Minimum 263 1 087 1 921 4 466 7 335 17 975
10 bar g
Maximum 4 672 19 197 33 862 78 386 128 050 310 382
Air (nm3 / h) at 20 °C
Nominal pipe size
Rotor Pressure
80 mm 150 mm 200 mm 300 mm 400 mm 600 mm
Minimum 12 49 87 204 337 838
1.4 bar g
Maximum 154 639 1 130 2 628 4 320 10 607
R40
Minimum 74 305 540 1 259 2 072 5 107
5 bar g
Maximum 946 3 898 6 884 15 969 26 152 63 694
Minimum 137 567 1 002 2 332 3 835 9 423
10 bar g
Maximum 1 751 7 205 12 718 29 476 48 216 117 169
Minimum 14 56 100 234 386 960
1.4 bar g
Maximum 226 934 1 651 3 839 6 306 15 455
R30
Minimum 84 350 619 1 441 2 373 5 844
5 bar g
Maximum 1 382 5 690 10 046 23 290 38 115 92 698
Minimum 157 649 1 148 2 671 4 390 10 779
10 bar g
Maximum 2 556 10 511 18 548 42 965 70 237 170 473
Minimum 24 100 178 415 684 1 696
1.4 bar g
Maximum 365 1 505 2 660 6 179 10 139 24 794
R20
Minimum 150 618 1 094 2 544 4 182 10 271
5 bar g
Maximum 2 224 9 149 16 145 37 407 61 166 148 520
Minimum 278 1 146 2 026 4 709 7 731 18 929
10 bar g
Maximum 4 110 16 888 29 789 68 956 112 643 273 032
Minimum 42 174 308 718 1 184 2 927
1.4 bar g
Maximum 756 3 115 5 502 12 768 20 919 50 995
R10
Minimum 259 1 069 1 890 4 393 7 214 17 668
5 bar g
Maximum 4 595 18 874 33 290 77 048 125 842 304 938
Minimum 480 1 980 3 499 8 125 13 323 32 541
10 bar g
Maximum 8 481 34 799 61 349 141 871 231 535 560 318
R40
Minimum 119 496 878 2 046 3 371 8 328
100 psi g
Maximum 1 540 6 350 11 216 26 034 42 668 104 092
Minimum 220 913 1 615 3 761 6 191 15 249
200 psi g
Maximum 2 827 11 643 20 558 47 681 78 064 190 027
Minimum 25 105 186 434 717 1 782
5 psi g
Maximum 420 1 735 3 068 7 135 11 721 28 745
R30
Minimum 137 568 1 006 2 344 3 861 9 530
100 psi g
Maximum 2 251 9 272 16 373 37 984 62 207 151 526
Minimum 253 1 046 1 850 4 308 7 088 17 446
200 psi g
Maximum 4 129 16 994 29 996 69 532 113 761 276 542
Minimum 45 186 330 770 1 270 3 150
5 psi g
Maximum 677 2 797 4 943 11 485 18 849 46 119
R20
Minimum 243 1 005 1 778 4 140 6 811 16 762
100 psi g
Maximum 3 623 14 915 26 328 61 035 99 870 242 834
Minimum 447 1 848 3 268 7 601 12 492 30 657
200 psi g
Maximum 6 643 27 317 48 203 111 658 182 535 443 035
Minimum 78 323 572 1 334 2 199 5 440
5 psi g
Maximum 1 405 5 790 10 227 23 736 38 897 94 870
R10
Minimum 421 1 739 3 075 7 153 11 755 28 849
100 psi g
Maximum 7 490 30 791 54 325 125 807 205 605 498 759
Minimum 774 3 195 5 647 13 123 21 541 52 728
200 psi g
Maximum 13 719 56 341 99 362 229 926 375 467 909 528
Air (SCFM) at 70 °F
Nominal pipe size
Rotor Pressure
3" 6" 8" 12" 16" 24"
Minimum 7 31 55 129 213 529
5 psi g
Maximum 98 404 714 1 660 2 729 6 702
R40
Minimum 62 255 451 1 051 1 730 4 257
100 psi g
Maximum 790 3 252 5 741 13 313 21 791 53 019
Minimum 117 484 857 1 992 3 273 8 031
200 psi g
Maximum 1 494 6 146 10 846 25 128 41 083 99 739
Minimum 9 36 63 148 244 606
5 psi g
Maximum 143 590 1 043 2 426 3 984 9 765
R30
Minimum 71 292 517 1 204 1 980 4 871
100 psi g
Maximum 1 153 4 746 8 376 19 412 31 753 77 152
Minimum 134 555 981 2 281 3 747 9 186
200 psi g
Maximum 2 181 8 964 15 814 36 617 59 832 145 094
Minimum 15 63 112 262 432 1 071
5 psi g
Maximum 230 951 1 680 3 904 6 406 15 665
R20
Minimum 125 517 913 2 124 3 489 8 557
100 psi g
Maximum 1 855 7 628 13 458 31 168 50 942 123 591
Minimum 237 979 1 730 4 020 6 595 16 126
200 psi g
Maximum 3 506 14 397 25 389 58 747 95 927 232 348
Minimum 26 110 195 454 748 1 849
5 psi g
Maximum 478 1 968 3 476 8 067 13 217 32 219
R10
Minimum 216 893 1 578 3 666 6 016 14 715
100 psi g
Maximum 3 831 15 728 27 734 64 166 104 762 253 698
Minimum 410 1 691 2 987 6 933 11 362 27 714
200 psi g
Maximum 7 230 29 650 52 259 120 804 197 092 476 732
Sizing considerations
Straight run piping requirements Upstream Downstream
One 90° elbow before the flowmeter 10 D 5D
Two 90° elbows before the flowmeter 15 D 5D
Two 90° elbows out of plane before the flowmeter 30 D 5D
Piping conditions
Reduction before the flowmeter 10 D 5D
Expansion before the flowmeter 20 D 5D
Partially open valve 30 D 5D
D = Internal diameter of the pipe - If there is not a sufficient straight run of pipe, a flow
rectifier may be used to reduce the above diameter measurements.
Consult your local Spirax Sarco representative or the factory for your specific application.
Maximum 9 metres / second (30 feet / second)
Liquid
Minimum 0.15 metres / second (0.5 feet / second)
Velocity range
Maximum 13 to 62 metres / second (43 to 205 feet / second) depending on rotor pitch
Gas or steam
Minimum 1 to 3.7 metres / second (3.5 to 12 feet / second) depending on rotor pitch
Accessories
Removable retractor
For models without a permanent retractor, one removable retractor must be used if the process pressure is >3.4 bar g (50 psi g).
Removable retractor
Removable retractor options
Extended length removable retractor – For use with extended length probes
Replacement rotors
Rotor assembly, liquid, 40° pitch L40
Rotor assembly, steam/gas, 10° pitch R10
Rotor assembly, steam/gas, 15° pitch R15
Rotor spares Rotor assembly, steam/gas, 20° pitch R20
Rotor assembly, steam/gas, 25° pitch R25
Rotor assembly, steam/gas, 30° pitch R30
Rotor assembly, steam/gas, 40° pitch R40
How to order example: 1 off Spirax Sarco RIM20 - L40 – Rotor Assembly.
How to order example: 1 off Spirax Sarco RIM20 - V - S - L - D - DL -1HL - S - P0 - PNPTR - S -R40 rotor insertion flowmeter.