• Current vector Control.
• High Starting torque: 200% at 0.5 Hz.
• Double rating VT 120%/1 min and CT 150% /1 min.
• Speed range up to 1,000 Hz.
• Positioning functionality.
• Safety function *1 EN ISO13849-1:2008 (Cat.3/PLd)
IEC60204-1 Stop Category 0
• Fieldbus communications with optional unit *2:
EtherCAT, CompoNet and DeviceNet *3
• Modbus communications.
*1 When optional communication unit is mounted onto the MX2, the inverter will not
conform to the safety standards.
*2 Optional communication unit can be used with the inverter 3G3MX2 of unit version
1.1 or higher.
*3 DeviceNet communication unit will be available soon.
Performance Specifications
Inverter 3G3MX2
3-phase 200 V Class
Function name 3-phase 200 V
Model name (3G3MX2-) A2001 A2002 A2004 A2007 A2015 A2022 A2037 A2055 A2075 A2110 A2150
CT 0.1 0.2 0.4 0.75 1.5 2.2 3.7 5.5 7.5 11 15
Applicable kW VT 0.2 0.4 0.75 1.1 2.2 3.0 5.5 7.5 11 15 18.5
motor
capacity CT 1/8 1/4 1/2 1 2 3 5 7 1/2 10 15 20
HP
VT 1/4 1/2 1 1 1/2 3 4 7 1/2 10 15 20 25
CT 0.2 0.5 1.0 1.7 2.7 3.8 6.0 8.6 11.4 16.2 20.7
Rated 200 V
output VT 0.4 0.6 1.2 2.0 3.3 4.1 6.7 10.3 13.8 19.3 23.9
capacity CT 0.3 0.6 1.2 2.0 3.3 4.5 7.2 10.3 13.7 19.5 24.9
[kVA] 240 V
VT 0.4 0.7 1.4 2.4 3.9 4.9 8.1 12.4 16.6 23.2 28.6
Rated input voltage 3-phase 200 V - 15% to 240 V + 10%, 50/60 Hz ± 5%
Rated input current CT 1.0 1.6 3.3 6.0 9.0 12.7 20.5 30.8 39.6 57.1 62.6
[A] VT 1.2 1.9 3.9 7.2 10.8 13.9 23.0 37.0 48.0 68.0 72.0
Rated output voltage 3-phase 200 to 240 V (The output cannot exceed the incoming voltage).
Rated output CT 1.0 1.6 3.0 5.0 8.0 11.0 17.5 25.0 33.0 47.0 60.0
current [A] VT 1.2 1.9 3.5 6.0 9.6 12.0 19.6 30.0 40.0 56.0 69.0
Short-time deceleration
braking torque (%)
50 50 50 50 50 20 20 20 20 10 10
(Discharge Resistor not
connected)
Regenerative
Braking Built-in Braking Resistor circuit (separate Discharge Resistor)
braking
Resistor
circuit * Min. connectable
100 100 100 50 50 35 35 20 17 17 10
resistance [Ω]
Weight [kg] 1.0 1.0 1.1 1.2 1.6 1.8 2.0 3.3 3.4 5.1 7.4
Dimensions (width × height) 140 × 180 × 220 ×
68 × 128 108 × 128 140 × 260
[mm] 128 296 350
Dimensions (depth) [mm] 109 122.5 145.5 170.5 170.5 155 175
* The BRD usage is 10%.
Sysmac is a trademark or registered trademark of OMRON Corporation in Japan and other countries for OMRON factory automation products.
Windows is registered trademarks of Microsoft Corporation in the USA and other countries.
EtherCAT® is a registered trademark and patented technology, licensed by Beckhoff Automation GmbH, Germany.
Other company names and product names in this document are the trademarks or registered trademarks of their respective companies.
1
Multi-function Compact Inverter MX2-Series
2
Multi-function Compact Inverter MX2-Series
Function Specifications
Function name Specifications
Enclosure ratings *1 Open type (IP20)
Control method Phase-to-phase sinusoidal modulation PWM
Output frequency range *2 0.10 to 400 Hz (or 1,000 Hz in the high-frequency mode; restrictions apply)
Frequency precision *3 Digital command: ±0.01% of the max. frequency, Analog command: ±0.2% of the max. frequency (25°C±10°C)
Frequency setting resolution Digital setting: 0.01 Hz, Analog setting: One-thousandth of the maximum frequency
Voltage/Frequency V/f characteristics (constant/reduced torque)
characteristics Sensorless vector control, V/f control with speed feedback
Control
Digital Operator
RUN/STOP command
External digital input signal (3-wire input supported), Modbus communication (Modbus-RTU)
Multi-function input 7 points (Selectable from 59 functions)
Analog input 2 points (Voltage FV terminal: 10 bits/0 to 10 V, Current FI terminal: 10 bits/4 to 20 mA)
Pulse input 1 point (RP terminal: 32 kHz max., 5 to 24 VDC)
Multi-function output 2 points (P1/EDM, P2; selectable from 43 functions)
Communications Output signal
Relay output 1 point (1c contact: MC, MA, MB; selectable from 43 functions)
Analog output (Frequency monitor) 1 point (AM terminal: Voltage 10 bits/0 to 10 V) (Frequency, current selectable)
Pulse output 1 point (MP terminal: 32 kHz max., 0 to 10 V)
AVR function, V/f characteristics switching, upper/lower limit, 16-step speeds, starting frequency
adjustment, jogging operation, carrier frequency adjustment, PID control, frequency jump, analog gain/
Other functions bias adjustment, S shape acceleration/deceleration, electronic thermal characteristics, level adjustment,
restart function, torque boost function, fault monitor, soft lock function, frequency conversion display,
USP function, motor 2 control function, UP/DWN, overcurrent control function, etc.
General specifications
Low voltage
EC EN61800-5-1: 2003
directive
directive
Machinery IEC60204-1 Stop Category 0, EN IEC61800-5-2 (STO), EN ISO13849-1: 2008 (PLd), ISO13849-1: 2006
directives (PLd)
UL/cUL UL508C
Note: 1. The applicable motor is a 3-phase standard motor. For using any other type, be sure that the rated current does not exceed that of the Inverter.
2. Output voltage decreases according to the level of the power supply voltage.
3. The braking torque at the time of capacitor feedback is an average deceleration torque at the shortest deceleration (when it stops from
50 Hz). It is not a continuous regeneration torque. Also, the average deceleration torque varies depending on the motor loss. The value
is reduced in operation over 50 Hz.
*1 Protection method complies with JEM 1030.
*2 To operate the motor at over 50/60 Hz, contact the motor manufacturer to find out the maximum allowable speed of revolution.
*3 For the stable control of the motor, the output frequency may exceed the maximum frequency set in A004 (A204) by 2 Hz max.
3
Multi-function Compact Inverter MX2-Series
Common Specifications
Item Specifications
Power supply Supplied from the inverter
Protective structure Open type (IP20)
Ambient operating temperature −10 to +50°C
Ambient storage temperature −20 to +65°C
Ambient operating humidity 20% to 90% RH (with no condensation)
Vibration resistance 5.9 m/s2 (0.6 G), 10 to 55 Hz
Application environment At a maximum altitude of 1,000 m; indoors (without corrosive gases or dust)
Weight 100 g max.
UL/cUL UL508C
International
standard EMC Directive :EN61800-3: 2004
EC directive
Low Voltage Directive :EN61800-5-1: 2003
Unit Versions
Unit version
Unit Model
Ver.1.0 Ver1.1
EtherCAT Communication Unit for MX2-Series 3G3AX-MX2-ECT Supported Supported
Compatible Sysmac Studio version Version1.00 or higher* Version1.00 or higher
* The function that was enhanced by the upgrade for Unit version1.1 can not be used. For detail, refer to "Function Support by Unit Version".
4
Multi-function Compact Inverter MX2-Series
Common Specification
Item Specification
Power supply Supplied from the inverter
Protective structure IP20
Ambient operating temperature − 10 to 55 °C (no icing or condensation)
Ambient storage temperature − 20 to 65 °C (no icing or condensation)
Ambient operating humidity 20 to 90%RH
Vibration resistance 5.9m/s2 (0.6G), 10 to 55Hz
Application environment At a maximum altitude of 1,000 m; indoors (without corrosive gases or dust)
Insulation resistance 500VAC (between isolated circuits)
Weight Approx. 170g
UL/cUL UL508
International standard EN61800-3: 2004 (2004/108/EC) Second environment, Category C3
EC directive
EN61800-5-1: 2007 (2006/95/EC) SELV
5
Multi-function Compact Inverter MX2-Series
Common Specification
Item Specification
Power supply Supplied from the inverter
Protective structure IP20
Ambient operating temperature − 10 to 55 °C (no icing or condensation)
Ambient storage temperature − 20 to 65 °C( no icing or condensation)
Ambient operating humidity 20 to 90%RH
Vibration resistance 5.9m/s2 (0.6G), 10 to 55Hz
Application environment At a maximum altitude of 1,000 m; indoors (without corrosive gases or dust)
Insulation resistance 500VAC (between isolated circuits)
Weight Approx. 170g
UL/cUL UL508
International standard EN61800-3: 2004 (2004/108/EC) Second environment, Category C3
EC directive
EN61800-5-1: 2007 (2006/95/EC) SELV
6
Multi-function Compact Inverter MX2-Series
Components and Functions
Inverter 3G3MX2
Modbus-RTU Termination resistor selector switch Safety function selector switch
CHARGE indicator
Main circuit terminal block
Name Function
Modbus-RTU Termination resistor Use this Terminal Resistor selector switch for RS-485 terminals on the control circuit terminal block. When this switch is turned
selector switch ON, the internal 200 Ω Resistor is connected.
Turn this switch ON when using the safety function. Turn OFF the power before turning this switch ON/OFF. For details, refer to
Safety function selector switch
USER’S MANUAL (Cat.No.I570).
Turn this switch ON when using the EDM output of the safety function. Turn OFF the power before turning this switch ON/
EDM function selector switch
OFF.For details, refer to USER’S MANUAL (Cat.No.I570).
Use this mini-B USB connector to connect a PC.
USB connector
Even when the Inverter is being operated by a PC, etc., via USB connection, it can still be operated using the Digital Operator.
Connector for Digital Operator Use this connector to connect the Digital Operator.
Connector for optional board Use this connector to mount the optional board. (Communications Units and other options can be connected.)
Control circuit terminal blocks A
These terminal blocks are used to connect various digital/analog input and output signals for inverter control, etc.
and B
Multi-function contact terminal block Use this SPDT contact terminal block for relay outputs.
Use this terminal block to connect an output to the motor and Braking Resistor, etc.
Main circuit terminal block
Also, use this terminal block to connect the inverter to the main power supply.
CHARGE indicator This LED indicator is lit if the DC voltage of the main circuit (between terminals P/+2 and N/-) remains approx. 45 V or above
(Charge indicator LED) after the power has been cut off. Before wiring, etc. confirm that the Charge LED indicator is turned OFF.
Note: This illustration shows the terminal block with the front cover removed.
FG cable
Communications connector
(IN, OUT)
7
Multi-function Compact Inverter MX2-Series
FG Cable
FG Cable
Connection Diagram
MC AX
MC AX
ON OFF
ELB
Single-phase MC
R/L1 (L1) *1
3-phase power U/T1
supply
S/L2
T/L3 (N) *1 V/T2
M
3~
24 VDC W/T3
If any source-logic external Shorting P24 Motor
output devices or external bar Shorting bar
PSC
power supply is used, refer DC reactor
+1
to User's Manual (I570) SC Remove the short
bar when connecting
P/+2 a DC reactor.
SC
Thermistor RB
S7/EB N/−
S6 MC Braking Resistor *2
S5/TH
MA Multi-function
Multi-function inputs S4/GS2 relay output
(7 contact inputs) MB
S3/GS1
S2
P2
S1
SC
Optional board connector Ground to 100 Ω or less for 200-V class
Ground to 10 Ω or less for 400-V class
Communications Option Unit *2
8
Multi-function Compact Inverter MX2-Series
Dimensions (Unit: mm)
5
Power supply Model W [mm] H [mm] D [mm] D1 [mm]
3G3MX2-AB001
1-phase 109 13.5
3G3MX2-AB002
D 200 V
3G3MX2-AB004 122.5 27
3G3MX2-A2001 68 128
109 13.5
3-phase 3G3MX2-A2002
D1
2.6 200 V 3G3MX2-A2004 122.5 27
3G3MX2-A2007 145.5 50
3G3MX2-A2037 140
Two, 4.5 dia.
3G3MX2-A4040 128
8.8.8.8.
118
128
170.5
Power supply Model W [mm] H [mm] D [mm] D1 [mm]
3-phase
3G3MX2-A2037
55 200 V
140 128 170.5 55
3-phase
3G3MX2-A4040
4.4
400 V
9
Multi-function Compact Inverter MX2-Series
3G3MX2-A2055 140
Two, 6 dia.
3G3MX2-A2075 122
3G3MX2-A4055
3G3MX2-A4075
8.8.8.8.
248
260
8.8.8.8.
284
296
8.8.8.8.
336
350
175
Power supply Model W [mm] H [mm] D [mm] D1 [mm]
84
3-phase
3G3MX2-A2150 220 350 175 84
200 V
5
10
Multi-function Compact Inverter MX2-Series
60.0
27.9
FG cable
52.6
Communications
10.3 10.3 Communications
connector (IN) 26.4mm *
connector (OUT)
D*
28.2
FG cable
*After the EtherCAT Communication Unit is installed, dimension D of the inverter increases by 26.4 mm.
(Dimension D of the inverter varies depending on the capacity. Refer to the MX2-series USER'S MANUAL (Cat.No.I570))
60.0 60.7
52.6
26.4mm*
D*
9.4
31.3
* After the CompoNet Communication Unit is installed, dimension D of the inverter increases by 26.4 mm.
(Dimension D of the inverter varies depending on the capacity. Refer to the MX2-series USER'S MANUAL (Cat.No.I570))
60.0
52.6
26.4mm*
D*
18.7
31.3
* After the DeviceNet Communication Unit is installed, dimension D of the inverter increases by 26.4 mm.
(Dimension D of the inverter varies depending on the capacity. Refer to the MX2-series USER'S MANUAL (Cat.No.I570))
11
MEMO
12
Ordering Information
System Configuration ....................................................................................14
Interpreting Model Numbers..........................................................................15
Ordering Information......................................................................................15
3G3MX2 Inverter Models .......................................................................................15
Communication Unit ..............................................................................................15
Related Options .....................................................................................................16
Recommended EtherCAT Communications Cables ...........................................21
Software..................................................................................................................22
Related Manuals .............................................................................................22
Multi-function Compact Inverter 3G3MX2
System Configuration
Machine Automation Programmable Programmable Programmable Built-in pulse I/O function type
Controller Controller Controller Controller CP1H/CP1L
NJ-series CJ2/CJ1 CJ2/CJ1 CS1
EtherCAT
Sysmac Studio Position Control Unit with CompoNet Master Unit DeviceNet Master Unit CX-One
EtherCAT interface CJ1W-CRM21/ CJ1W-DRM21/
CJ1W-NC@81/NC@82 CS1W-CRM21 CS1W-DRM21-V1
EtherCAT
CompoNet
DeviceNet
Modbus I/O
MX2-series
3G3MX2-@@@@@
USB
3G3AX-MX2-ECT
3G3AX-MX2-CRT-E
3G3AX-MX2-DRT-E
DC reactor
3G3AX-DL@@@@
R S T Power supply
3-phase 200VAC 3-phase
M
( 3-phase 400VAC
1-phase 200VAC ) induction
motor
14
Multi-function Compact Inverter 3G3MX2
Interpreting Model Numbers
1 2
3G3MX2
Ordering Information
3G3MX2 Inverter Models
Max. applicable motor capacity
Rated voltage Enclosure ratings Model
CT: Heavy load VT: Light load
0.1kW 0.2 kW 3G3MX2-A2001
0.2 kW 0.4 kW 3G3MX2-A2002
0.4 kW 0.75 kW 3G3MX2-A2004
0.75 kW 1.1 kW 3G3MX2-A2007
1.5 kW 2.2 kW 3G3MX2-A2015
3-phase 200 VAC IP20 2.2 kW 3.0 kW 3G3MX2-A2022
3.7 kW 5.5 kW 3G3MX2-A2037
5.5 kW 7.5 kW 3G3MX2-A2055
7.5 kW 11 kW 3G3MX2-A2075
11 kW 15 kW 3G3MX2-A2110
15 kW 18.5 kW 3G3MX2-A2150
0.4 kW 0.75 kW 3G3MX2-A4004
0.75 kW 1.5 kW 3G3MX2-A4007
1.5 kW 2.2 kW 3G3MX2-A4015
2.2 kW 3.0 kW 3G3MX2-A4022
3.0 kW 4.0 kW 3G3MX2-A4030
3-phase 400 VAC IP20
4.0 kW 5.5 kW 3G3MX2-A4040
5.5 kW 7.5 kW 3G3MX2-A4055
7.5 kW 11 kW 3G3MX2-A4075
11 kW 15 kW 3G3MX2-A4110
15 kW 18.5 kW 3G3MX2-A4150
0.1 kW 0.2 kW 3G3MX2-AB001
0.2 kW 0.4 kW 3G3MX2-AB002
0.4 kW 0.55 kW 3G3MX2-AB004
1-phase 200 VAC IP20
0.75 kW 1.1 kW 3G3MX2-AB007
1.5 kW 2.2 kW 3G3MX2-AB015
2.2 kW 3.0 kW 3G3MX2-AB022
Communication Unit
Name Model
EtherCAT Communication Unit 3G3AX-MX2-ECT
CompoNet Communication Unit 3G3AX-MX2-CRT-E
DeviceNet Communication Unit 3G3AX-MX2-DRT-E Available soon
15
Multi-function Compact Inverter 3G3MX2
Related Options
Name Specifications Model
General purpose with Braking resistor 3G3AX-RBU21
3-phase 200 VAC
Regenerative Braking Units High Regeneration purpose with Braking resistor 3G3AX-RBU22
3-phase 400 VAC General purpose with Braking resistor 3G3AX-RBU41
Resistor 120 W, 180 Ω 3G3AX-RBA1201
Resistor 120 W, 100 Ω 3G3AX-RBA1202
Compact type
Resistor 120 W, 5 Ω 3G3AX-RBA1203
Resistor 120 W, 35 Ω 3G3AX-RBA1204
Resistor 200 W, 180 Ω 3G3AX-RBB2001
Braking Resistor Resistor 200 W, 100 Ω 3G3AX-RBB2002
Standard type
Resistor 300 W, 50 Ω 3G3AX-RBB3001
Resistor 400 W, 35 Ω 3G3AX-RBB4001
Resistor 400 W, 50 Ω 3G3AX-RBC4001
Medium capacity type Resistor 600 W, 35 Ω 3G3AX-RBC6001
Resistor 1200 W, 17 Ω 3G3AX-RBC12001
16
Multi-function Compact Inverter 3G3MX2
Regenerative
Inverter Usage conditions Braking resistor Restrictions
braking unit
Connection Allowable Min.
Max.applicable Approximate configuration
%ED *1 Number Number continuous connectable
Voltage motor capacity Model braking torque Model Model
[%] of units of units braking resistance
(kW) [% *2 ]
time(s) [Ω]
3.0% 220% 3G3AX-RBA1201 2 3 20 180
0.4 3G3MX2-A4004 Built-in Inverter
10.0% 220% 3G3AX-RBB2001 2 3 30 180
3.0% 220% 3G3AX-RBA1201 2 3 20 180
0.75 3G3MX2-A4007 Built-in Inverter
10.0% 220% 3G3AX-RBB2001 2 3 30 180
3.0% 120% 3G3AX-RBA1201 2 3 20 180
1.5 3G3MX2-A4015 Built-in Inverter
10.0% 120% 3G3AX-RBB2001 2 3 30 180
2.5% 150% 3G3AX-RBA1202 2 3 12 100
2.2 3G3MX2-A4022 Built-in Inverter
10.0% 220% 3G3AX-RBC4001 2 3 10 100
2.5% 110% 3G3AX-RBA1202 2 3 12 100
3.0 3G3MX2-A4030 Built-in Inverter
10.0% 215% 3G3AX-RBC4001 2 3 10 100
400-V 3.0% 165% 3G3AX-RBB3001 2 3 30 100
Class 4.0 3G3MX2-A4040 Built-in Inverter
10.0% 165% 3G3AX-RBC4001 2 3 10 100
3.0% 120% 3G3AX-RBB3001 2 3 30 70
5.5 3G3MX2-A4055 Built-in Inverter
10.0% 120% 3G3AX-RBC4001 2 3 10 70
3.0% 125% 3G3AX-RBB4001 2 3 20 70
7.5 3G3MX2-A4075 Built-in Inverter
10.0% 125% 3G3AX-RBC6001 2 3 10 70
3.0% 85% 3G3AX-RBB4001 2 3 20 70
Built-in Inverter
10.0% 85% 3G3AX-RBC6001 2 3 10 70
11 3G3MX2-A4110
3G3AX-RBU41
10.0% 120% 1 3G3AX-RBC4001 4 15 10 34
*3
3.0% 125% 3G3AX-RBB4001 4 5 20 35
15 3G3MX2-A4150 Built-in Inverter
10.0% 125% 3G3AX-RBC6001 4 5 10 35
*1 %ED shows the ratio that can be used for braking (deceleration time) among operating time of one task period.
*2 Approximate breaking torque is shown in % of rating torque of the motor (100%).
*3 Please remove the built-in resistor.
Connection configuration
TYPE TYPE
17
Multi-function Compact Inverter 3G3MX2
Specifications of Inverter
Name Model
Voltage class CT: Heavy load VT: Light load
0.1 kW 0.2 kW
0.2 kW 0.4 kW
0.4 kW 0.75 kW
3G3AX-ZCL2
0.75 kW 1.1 kW
1.5 kW 2.2 kW
3-phase 200 VAC 2.2 kW 3.0 kW
3.7 kW 5.5 kW
3G3AX-ZCL1 (3G3AX-ZCL2)
5.5 kW 7.5 kW
7.5 kW 11 kW
11 kW 15 kW 3G3AX-ZCL1
15 kW 18.5 kW
0.1 kW 0.2 kW
0.2 kW 0.4 kW
Radio Noise Filter 0.4 kW 0.55 kW
1-phase 200 VAC 3G3AX-ZCL2
0.75 kW 1.1 kW
1.5 kW 2.2 kW
2.2 kW 3.0 kW
0.4 kW 0.75 kW
0.75 kW 1.5 kW
1.5 kW 2.2 kW
2.2 kW 3.0 kW 3G3AX-ZCL2 (3G3AX-ZCL1)
3.0 kW 4.0 kW
3-phase 400 VAC
4.0 kW 5.5 kW
5.5 kW 7.5 kW
7.5 kW 11 kW
11 kW 15 kW 3G3AX-ZCL1
15 kW 18.5 kW
0.1 kW 0.2 kW
0.2 kW 0.4 kW 3G3AX-NFI21
0.4 kW 0.75 kW
0.75 kW 1.1 kW 3G3AX-NFI22
1.5 kW 2.2 kW
3G3AX-NFI23
3-phase 200 VAC 2.2 kW 3.0 kW
3.7 kW 5.5 kW 3G3AX-NFI24
5.5 kW 7.5 kW 3G3AX-NFI25
7.5 kW 11 kW 3G3AX-NFI26
11 kW 15 kW 3G3AX-NFI27
15 kW 18.5 kW 3G3AX-NFI28
0.1 kW 0.2 kW
3G3AX-NFI21
0.2 kW 0.4 kW
Input Noise Filter 0.4 kW 0.55 kW 3G3AX-NFI22
1-phase 200 VAC
0.75 kW 1.1 kW 3G3AX-NFI23
1.5 kW 2.2 kW 3G3AX-NFI23 *
2.2 kW 3.0 kW 3G3AX-NFI24
0.4 kW 0.75 kW
0.75 kW 1.5 kW 3G3AX-NFI41
1.5 kW 2.2 kW
2.2 kW 3.0 kW
3G3AX-NFI42
3.0 kW 4.0 kW
3-phase 400 VAC
4.0 kW 5.5 kW
3G3AX-NFI43
5.5 kW 7.5 kW
7.5 kW 11 kW 3G3AX-NFI44
11 kW 15 kW 3G3AX-NFI45
15 kW 18.5 kW 3G3AX-NFI46
* Only the CT rating is supported.
18
Multi-function Compact Inverter 3G3MX2
Specifications of Inverter
Name Model
Voltage class CT: Heavy load VT: Light load
0.1 kW 0.2 kW
0.2 kW 0.4 kW
0.4 kW 0.75 kW
0.75 kW 1.1 kW
1.5 kW 2.2 kW
3-phase 200 VAC 2.2 kW 3.0 kW
3.7 kW 5.5 kW
5.5 kW 7.5 kW
7.5 kW 11 kW
11 kW 15 kW
15 kW 18.5 kW
0.1 kW 0.2 kW
0.2 kW 0.4 kW
Schaffner product will be
EMC-compatible Noise Filter 0.4 kW 0.55 kW
1-phase 200 VAC supported in future.
0.75 kW 1.1 kW
1.5 kW 2.2 kW
2.2 kW 3.0 kW
0.4 kW 0.75 kW
0.75 kW 1.5 kW
1.5 kW 2.2 kW
2.2 kW 3.0 kW
3.0 kW 4.0 kW
3-phase 400 VAC
4.0 kW 5.5 kW
5.5 kW 7.5 kW
7.5 kW 11 kW
11 kW 15 kW
15 kW 18.5 kW
0.1 kW 0.2 kW
0.2 kW 0.4 kW 3G3AX-NFO01
0.4 kW 0.75 kW
0.75 kW 1.1 kW
3G3AX-NFO02
1.5 kW 2.2 kW
3-phase 200 VAC 2.2 kW 3.0 kW
3G3AX-NFO03
3.7 kW 5.5 kW
5.5 kW 7.5 kW
3G3AX-NFO04
7.5 kW 11 kW
11 kW 15 kW 3G3AX-NFO05
15 kW 18.5 kW 3G3AX-NFO06
0.1 kW 0.2 kW
3G3AX-NFO01
0.2 kW 0.4 kW
Output Noise Filter 0.4 kW 0.55 kW
1-phase 200 VAC 3G3AX-NFO02
0.75 kW 1.1 kW
1.5 kW 2.2 kW
3G3AX-NFO03
2.2 kW 3.0 kW
0.4 kW 0.75 kW
3G3AX-NFO01
0.75 kW 1.5 kW
1.5 kW 2.2 kW
2.2 kW 3.0 kW 3G3AX-NFO02
3.0 kW 4.0 kW
3-phase 400 VAC
4.0 kW 5.5 kW
5.5 kW 7.5 kW 3G3AX-NFO03
7.5 kW 11 kW
11 kW 15 kW
3G3AX-NFO04
15 kW 18.5 kW
19
Multi-function Compact Inverter 3G3MX2
Specifications of Inverter
Name Model
Voltage class CT: Heavy load VT: Light load
0.1 kW 0.2 kW 3G3AX-DL2002
0.2 kW 0.4 kW 3G3AX-DL2004
0.4 kW 0.75 kW 3G3AX-DL2007
0.75 kW 1.1 kW 3G3AX-DL2015
1.5 kW 2.2 kW 3G3AX-DL2022
3-phase 200 VAC 2.2 kW 3.0 kW 3G3AX-DL2037
3.7 kW 5.5 kW 3G3AX-DL2055
5.5 kW 7.5 kW 3G3AX-DL2075
7.5 kW 11 kW 3G3AX-DL2110
11 kW 15 kW 3G3AX-DL2150
15 kW 18.5 kW 3G3AX-DL2220
0.1 kW 0.2 kW 3G3AX-DL2002
0.2 kW 0.4 kW 3G3AX-DL2004
DC Reactor 0.4 kW 0.55 kW 3G3AX-DL2007
1-phase 200 VAC
0.75 kW 1.1 kW 3G3AX-DL2015
1.5 kW 2.2 kW 3G3AX-DL2022
2.2 kW 3.0 kW 3G3AX-DL2037
0.4 kW 0.75 kW 3G3AX-DL4007
0.75 kW 1.5 kW 3G3AX-DL4015 *
1.5 kW 2.2 kW 3G3AX-DL4022
2.2 kW 3.0 kW
3G3AX-DL4037
3.0 kW 4.0 kW
3-phase 400 VAC
4.0 kW 5.5 kW 3G3AX-DL4055
5.5 kW 7.5 kW 3G3AX-DL4075 *
7.5 kW 11 kW 3G3AX-DL4110 *
11 kW 15 kW 3G3AX-DL4150
15 kW 18.5 kW 3G3AX-DL4220
0.1 kW 0.2 kW
0.2 kW 0.4 kW
3G3AX-AL2025
0.4 kW 0.75 kW
0.75 kW 1.1 kW
1.5 kW 2.2 kW
3G3AX-AL2055
3-phase 200 VAC 2.2 kW 3.0 kW
3.7 kW 5.5 kW 3G3AX-AL2110
5.5 kW 7.5 kW 3G3AX-AL2110 *
7.5 kW 11 kW 3G3AX-AL2220
11 kW 15 kW 3G3AX-AL2220 *
15 kW 18.5 kW 3G3AX-AL2330
0.1 kW 0.2 kW
0.2 kW 0.4 kW
3G3AX-AL2025
AC Reactor 0.4 kW 0.55 kW
1-phase 200 VAC
0.75 kW 1.1 kW
1.5 kW 2.2 kW 3G3AX-AL2055 *
2.2 kW 3.0 kW 3G3AX-AL2110
0.4 kW 0.75 kW
3G3AX-AL4025
0.75 kW 1.5 kW
1.5 kW 2.2 kW
2.2 kW 3.0 kW 3G3AX-AL4055
3.0 kW 4.0 kW
3-phase 400 VAC
4.0 kW 5.5 kW 3G3AX-AL4110
5.5 kW 7.5 kW 3G3AX-AL4110 *
7.5 kW 11 kW 3G3AX-AL4220
11 kW 15 kW 3G3AX-AL4220 *
15 kW 18.5 kW 3G3AX-AL4330
* Only the CT rating is supported.
Note: When using the Inverter for light load rating, select the model with one size larger capacity (rated current).
20
Multi-function Compact Inverter 3G3MX2
Cables / Connectors
Wire Gauge and Number of Pairs: AWG24, 4-pair Cable
Item Appearance Recommended manufacturer Model
− Tonichi Kyosan Cable, Ltd. NETSTAR-C5E SAB 0.5 x 4P *
Cables − Kuramo Electric Co. KETH-SB *
− SWCC Showa Cable Systems Co. FAE-5004 *
RJ45 Connectors − Panduit Corporation MPS588 *
* We recommend you to use above cable and connector together.
21
Multi-function Compact Inverter 3G3MX2
Software
How to Select Required Support Software for Your Controller
The required Support Software depends on the Controller to connect. Please check the following table when purchasing the Support Software.
Inverter MX2-series
Inverter Inverter MX2-series with CompoNet Communication Unit Inverter MX2-series with EtherCAT Communication Unit
Inverter MX2-series with DeviceNet Communication Unit
Related Manuals
Man. No. Model Manual
I570 3G3MX2 Multi-function Compact Inverter MX2-series USER'S MANUAL
I574 3G3AX-MX2-ECT EtherCAT Communication Unit USER'S MANUAL
I581 3G3AX-MX2-DRT-E * MX2 series DeviceNet Communication Unit USER'S MANUAL
I582 3G3AX-MX2-CRT-E MX2 series CompoNet Communication Unit USER'S MANUAL
W487 CJ1W-NC@81/CJ1W-NC@82 CJ-series Position Control Unit Operation Manual
W463 CXONE-AL@@C/D-V@ CX-One FA Integrated Tool Package Setup Manual
W446 CXONE-AL@@C-V@/-AL@@D-V@ CX-Programmer Operation Manual
W453 CXONE-AL@C/D-V@/WS02-DRVC01 CX-Drive OPERATION MANUAL
W504 SYSMAC-SE2@@@ Sysmac Studio Version 1 Operation Manual
* MX2-series DeviceNet communication unit is available soon.
22
Read and Understand this Catalog
Please read and understand this catalog before purchasing the product. Please consult your OMRON representative if you have
any questions or comments.
LIMITATIONS OF LIABILITY
OMRON SHALL NOT BE RESPONSIBLE FOR SPECIAL, INDIRECT, OR CONSEQUENTIAL DAMAGES, LOSS OF PROFITS,
OR COMMERCIAL LOSS IN ANY WAY CONNECTED WITH THE PRODUCTS, WHETHER SUCH CLAIM IS BASED ON
CONTRACT, WARRANTY, NEGLIGENCE, OR STRICT LIABILITY.
In no event shall the responsibility of OMRON for any act exceed the individual price of the product on which liability is asserted.
IN NO EVENT SHALL OMRON BE RESPONSIBLE FOR WARRANTY, REPAIR, OR OTHER CLAIMS REGARDING THE
PRODUCTS UNLESS OMRON'S ANALYSIS CONFIRMS THAT THE PRODUCTS WERE PROPERLY HANDLED, STORED,
INSTALLED, AND MAINTAINED AND NOT SUBJECT TO CONTAMINATION, ABUSE, MISUSE, OR INAPPROPRIATE
MODIFICATION OR REPAIR.
Application Considerations
SUITABILITY FOR USE
OMRON shall not be responsible for conformity with any standards, codes, or regulations that apply to the combination of
products in the customer's application or use of the products.
Take all necessary steps to determine the suitability of the product for the systems, machines, and equipment with which it will
be used.
Know and observe all prohibitions of use applicable to this product.
NEVER USE THE PRODUCTS FOR AN APPLICATION INVOLVING SERIOUS RISK TO LIFE OR PROPERTY WITHOUT
ENSURING THAT THE SYSTEM AS A WHOLE HAS BEEN DESIGNED TO ADDRESS THE RISKS, AND THAT THE OMRON
PRODUCTS ARE PROPERLY RATED AND INSTALLED FOR THE INTENDED USE WITHIN THE OVERALL EQUIPMENT OR
SYSTEM.
PROGRAMMABLE PRODUCTS
OMRON shall not be responsible for the user’s programming of a programmable product, or any consequence thereof.
Disclaimers
CHANGE IN SPECIFICATIONS
Product specifications and accessories may be changed at any time based on improvements and other reasons.
It is our practice to change model numbers when published ratings or features are changed, or when significant construction
changes are made. However, some specifications of the products may be changed without any notice. When in doubt, special
model numbers may be assigned to fix or establish key specifications for your application on your request. Please consult with
your OMRON representative at any time to confirm actual specifications of purchased products.
PERFORMANCE DATA
Performance data given in this catalog is provided as a guide for the user in determining suitability and does not constitute a
warranty. It may represent the result of OMRON’s test conditions, and the users must correlate it to actual application
requirements. Actual performance is subject to the OMRON Warranty and Limitations of Liability.
OMRON Corporation OMRON ELECTRONICS LLC
One Commerce Drive Schaumburg,
Authorized Distributor:
Industrial Automation Company
Control Devices Division H.Q. IL 60173-5302 U.S.A.
Automation & Drive Division Tel: (1) 847-843-7900/Fax: (1) 847-843-7787
Drive Department 1
Shiokoji Horikawa, Shimogyo-ku, OMRON ASIA PACIFIC PTE. LTD.
Kyoto, 600-8530 Japan No. 438A Alexandra Road # 05-05/08 (Lobby 2),
Tel: (81) 75-344-7173/Fax: (81) 75-344-7149 Alexandra Technopark, Singapore 119967
Tel: (65) 6835-3011/Fax: (65) 6835-2711