Location via proxy:   [ UP ]  
[Report a bug]   [Manage cookies]                

OMRON Braking Resistor

Download as pdf or txt
Download as pdf or txt
You are on page 1of 24

Multi-function Compact Inverter

MX2-Series
With Machine Automation Mentality
• Current vector Control.
• High Starting torque: 200% at 0.5 Hz.
• Double rating VT 120%/1 min and CT 150% /1 min.
• Speed range up to 1,000 Hz.
• Positioning functionality.
• Safety function *1 EN ISO13849-1:2008 (Cat.3/PLd)
IEC60204-1 Stop Category 0
• Fieldbus communications with optional unit *2:
EtherCAT, CompoNet and DeviceNet *3
• Modbus communications.
*1 When optional communication unit is mounted onto the MX2, the inverter will not
conform to the safety standards.
*2 Optional communication unit can be used with the inverter 3G3MX2 of unit version
1.1 or higher.
*3 DeviceNet communication unit will be available soon.

Performance Specifications
Inverter 3G3MX2
3-phase 200 V Class
Function name 3-phase 200 V
Model name (3G3MX2-) A2001 A2002 A2004 A2007 A2015 A2022 A2037 A2055 A2075 A2110 A2150
CT 0.1 0.2 0.4 0.75 1.5 2.2 3.7 5.5 7.5 11 15
Applicable kW VT 0.2 0.4 0.75 1.1 2.2 3.0 5.5 7.5 11 15 18.5
motor
capacity CT 1/8 1/4 1/2 1 2 3 5 7 1/2 10 15 20
HP
VT 1/4 1/2 1 1 1/2 3 4 7 1/2 10 15 20 25
CT 0.2 0.5 1.0 1.7 2.7 3.8 6.0 8.6 11.4 16.2 20.7
Rated 200 V
output VT 0.4 0.6 1.2 2.0 3.3 4.1 6.7 10.3 13.8 19.3 23.9
capacity CT 0.3 0.6 1.2 2.0 3.3 4.5 7.2 10.3 13.7 19.5 24.9
[kVA] 240 V
VT 0.4 0.7 1.4 2.4 3.9 4.9 8.1 12.4 16.6 23.2 28.6
Rated input voltage 3-phase 200 V - 15% to 240 V + 10%, 50/60 Hz ± 5%
Rated input current CT 1.0 1.6 3.3 6.0 9.0 12.7 20.5 30.8 39.6 57.1 62.6
[A] VT 1.2 1.9 3.9 7.2 10.8 13.9 23.0 37.0 48.0 68.0 72.0
Rated output voltage 3-phase 200 to 240 V (The output cannot exceed the incoming voltage).
Rated output CT 1.0 1.6 3.0 5.0 8.0 11.0 17.5 25.0 33.0 47.0 60.0
current [A] VT 1.2 1.9 3.5 6.0 9.6 12.0 19.6 30.0 40.0 56.0 69.0
Short-time deceleration
braking torque (%)
50 50 50 50 50 20 20 20 20 10 10
(Discharge Resistor not
connected)
Regenerative
Braking Built-in Braking Resistor circuit (separate Discharge Resistor)
braking
Resistor
circuit * Min. connectable
100 100 100 50 50 35 35 20 17 17 10
resistance [Ω]
Weight [kg] 1.0 1.0 1.1 1.2 1.6 1.8 2.0 3.3 3.4 5.1 7.4
Dimensions (width × height) 140 × 180 × 220 ×
68 × 128 108 × 128 140 × 260
[mm] 128 296 350
Dimensions (depth) [mm] 109 122.5 145.5 170.5 170.5 155 175
* The BRD usage is 10%.
Sysmac is a trademark or registered trademark of OMRON Corporation in Japan and other countries for OMRON factory automation products.
Windows is registered trademarks of Microsoft Corporation in the USA and other countries.
EtherCAT® is a registered trademark and patented technology, licensed by Beckhoff Automation GmbH, Germany.
Other company names and product names in this document are the trademarks or registered trademarks of their respective companies.

1
Multi-function Compact Inverter MX2-Series

3-phase 400 V Class


Function name 3-phase 400 V
Model name (3G3MX2-) A4004 A4007 A4015 A4022 A4030 A4040 A4055 A4075 A4110 A4150
CT 0.4 0.75 1.5 2.2 3.0 4.0 5.5 7.5 11 15
Applicable kW VT 0.75 1.5 2.2 3.0 4.0 5.5 7.5 11 15 18.5
motor
capacity CT 1/2 1 2 3 4 5 7 1/2 10 15 20
HP
VT 1 2 3 4 5 7 1/2 10 15 20 25
CT 1.1 2.2 3.1 3.6 4.7 6.0 9.7 11.8 15.7 20.4
Rated 380 V
output VT 1.3 2.6 3.5 4.5 5.7 7.3 11.5 15.1 20.4 25.0
capacity CT 1.4 2.8 3.9 4.5 5.9 7.6 12.3 14.9 19.9 25.7
[kVA] 480 V
VT 1.7 3.4 4.4 5.7 7.3 9.2 14.5 19.1 25.7 31.5
Rated input voltage 3-phase 380 V - 15% to 480 V + 10%, 50/60 Hz ± 5%
Rated input current CT 1.8 3.6 5.2 6.5 7.7 11.0 16.9 18.8 29.4 35.9
[A] VT 2.1 4.3 5.9 8.1 9.4 13.3 20.0 24.0 38.0 44.0
Rated output voltage 3-phase 380 to 480 V (The output cannot exceed the incoming voltage).
Rated output CT 1.8 3.4 4.8 5.5 7.2 9.2 14.8 18.0 24.0 31.0
current [A] VT 2.1 4.1 5.4 6.9 8.8 11.1 17.5 23.0 31.0 38.0
Short-time deceleration
braking torque (%)
50 50 50 20 20 20 20 20 10 10
(Discharge Resistor not
connected)
Regenerative
Braking Built-in Braking Resistor circuit (separate Discharge Resistor)
braking
Resistor
circuit * Min. connectable
180 180 180 100 100 100 70 70 70 35
resistance [Ω]
Weight [kg] 1.5 1.6 1.8 1.9 1.9 2.1 3.5 3.5 4.7 5.2
Dimensions (width × height) 140 ×
108 × 128 140 × 260 180 × 296
[mm] 128
Dimensions (depth) [mm] 143.5 170.5 170.5 155 175
* The BRD usage is 10%.

1-phase 200 V Class


Function name 1-phase 200 V
Model name (3G3MX2-) AB001 AB002 AB004 AB007 AB015 AB022
CT 0.1 0.2 0.4 0.75 1.5 2.2
Applicable kW VT 0.2 0.4 0.55 1.1 2.2 3.0
motor
capacity CT 1/8 1/4 1/2 1 2 3
HP
VT 1/4 1/2 3/4 1 1/2 3 4
CT 0.2 0.5 1.0 1.7 2.7 3.8
Rated 200 V
output VT 0.4 0.6 1.2 2.0 3.3 4.1
capacity CT 0.3 0.6 1.2 2.0 3.3 4.5
[kVA] 240 V
VT 0.4 0.7 1.4 2.4 3.9 4.9
Rated input voltage 1-phase 200 V - 15% to 240 V + 10%, 50/60 Hz ± 5%
Rated input current CT 1.3 3.0 6.3 11.5 16.8 22.0
[A] VT 2.0 3.6 7.3 13.8 20.2 24.0
Rated output voltage 3-phase 200 to 240 V (The output cannot exceed the incoming voltage).
Rated output CT 1.0 1.6 3.0 5.0 8.0 11.0
current [A] VT 1.2 1.9 3.5 6.0 9.6 12.0
Short-time deceleration
braking torque (%)
50 50 50 50 50 20
(Discharge Resistor not
connected)
Regenerative
Braking Built-in Braking Resistor circuit (separate Discharge Resistor)
braking
Resistor
circuit * Min. connectable
100 100 100 50 50 35
resistance [Ω]
Weight [kg] 1.0 1.0 1.1 1.6 1.8 1.8
Dimensions (width × height)
68 × 128 108 × 128
[mm]
Dimensions (depth) [mm] 109 122.5 170.5
* The BRD usage is 10%.

2
Multi-function Compact Inverter MX2-Series
Function Specifications
Function name Specifications
Enclosure ratings *1 Open type (IP20)
Control method Phase-to-phase sinusoidal modulation PWM
Output frequency range *2 0.10 to 400 Hz (or 1,000 Hz in the high-frequency mode; restrictions apply)
Frequency precision *3 Digital command: ±0.01% of the max. frequency, Analog command: ±0.2% of the max. frequency (25°C±10°C)
Frequency setting resolution Digital setting: 0.01 Hz, Analog setting: One-thousandth of the maximum frequency
Voltage/Frequency V/f characteristics (constant/reduced torque)
characteristics Sensorless vector control, V/f control with speed feedback
Control

Heavy load rating (CT): 150%/60 s


Overload current rating
Light load rating (VT): 120%/60 s
Instantaneous overcurrent
200% of the value of heavy load rating (CT)
protection
Acceleration/Deceleration time 0.01 to 3600 s (linear/curve selection), acceleration/deceleration 2 setting available
Carrier frequency adjustment range 2 to 15 kHz (with derating)
Starting torque 200%/0.5 Hz (sensorless vector control)
Starts at a frequency lower than that in deceleration via the STOP command, at a value set lower than
External DC injection braking
that during operation, or via an external input. (Level and time settable).
Overcurrent, overvoltage, undervoltage, electronic thermal, temperature error, ground fault overcurrent
at power-on status, rush current prevention circuit, overload limit, incoming overvoltage, external trip,
Protective functions
memory error, CPU error, USP error, communication error, overvoltage suppression during
deceleration, protection upon momentary power outage, emergency cutoff, etc.
Digital Operator
Frequency settings
External analog input signal: 0 to 10 VDC/4 to 20 mA, Modbus communication (Modbus-RTU)
Input signal

Digital Operator
RUN/STOP command
External digital input signal (3-wire input supported), Modbus communication (Modbus-RTU)
Multi-function input 7 points (Selectable from 59 functions)
Analog input 2 points (Voltage FV terminal: 10 bits/0 to 10 V, Current FI terminal: 10 bits/4 to 20 mA)
Pulse input 1 point (RP terminal: 32 kHz max., 5 to 24 VDC)
Multi-function output 2 points (P1/EDM, P2; selectable from 43 functions)
Communications Output signal

Relay output 1 point (1c contact: MC, MA, MB; selectable from 43 functions)
Analog output (Frequency monitor) 1 point (AM terminal: Voltage 10 bits/0 to 10 V) (Frequency, current selectable)
Pulse output 1 point (MP terminal: 32 kHz max., 0 to 10 V)

RS-422 RJ45 connector (for Digital Operator)

RS-485 Control circuit terminal block, Modbus communication (Modbus-RTU)

USB USB1.1, mini-B connector

AVR function, V/f characteristics switching, upper/lower limit, 16-step speeds, starting frequency
adjustment, jogging operation, carrier frequency adjustment, PID control, frequency jump, analog gain/
Other functions bias adjustment, S shape acceleration/deceleration, electronic thermal characteristics, level adjustment,
restart function, torque boost function, fault monitor, soft lock function, frequency conversion display,
USP function, motor 2 control function, UP/DWN, overcurrent control function, etc.
General specifications

Ambient temperature -10 to 50°C (However, derating is required).

Ambient storage temperature -20°C to 65°C (short-time temperature during transport)

Humidity 20% to 90% RH (with no condensation)

Vibration 5.9 m/s2 (0.6G), 10 to 55 Hz

Location At a maximum altitude of 1,000 m; indoors (without corrosive gases or dust)


DC reactor, AC reactor, radio noise filter, input noise filter, output noise filter, regenerative braking unit,
Options
Braking Resistor, EMC noise filter, etc.
EMC directive EN61800-3: 2004
International standard

Low voltage
EC EN61800-5-1: 2003
directive
directive
Machinery IEC60204-1 Stop Category 0, EN IEC61800-5-2 (STO), EN ISO13849-1: 2008 (PLd), ISO13849-1: 2006
directives (PLd)

UL/cUL UL508C

Note: 1. The applicable motor is a 3-phase standard motor. For using any other type, be sure that the rated current does not exceed that of the Inverter.
2. Output voltage decreases according to the level of the power supply voltage.
3. The braking torque at the time of capacitor feedback is an average deceleration torque at the shortest deceleration (when it stops from
50 Hz). It is not a continuous regeneration torque. Also, the average deceleration torque varies depending on the motor loss. The value
is reduced in operation over 50 Hz.
*1 Protection method complies with JEM 1030.
*2 To operate the motor at over 50/60 Hz, contact the motor manufacturer to find out the maximum allowable speed of revolution.
*3 For the stable control of the motor, the output frequency may exceed the maximum frequency set in A004 (A204) by 2 Hz max.

3
Multi-function Compact Inverter MX2-Series

MX2-Series EtherCAT Communication Unit 3G3AX-MX2-ECT


This is the communication unit to connect the Multi-function Compact Inverter MX2 to EtherCAT network.
This communication unit passed the conformance test of EtherCAT.
Note: EtherCAT Communication Unit 3G3AX-MX2-ECT can be used with the inverter 3G3MX2 of unit version 1.1 or higher.

Common Specifications
Item Specifications
Power supply Supplied from the inverter
Protective structure Open type (IP20)
Ambient operating temperature −10 to +50°C
Ambient storage temperature −20 to +65°C
Ambient operating humidity 20% to 90% RH (with no condensation)
Vibration resistance 5.9 m/s2 (0.6 G), 10 to 55 Hz
Application environment At a maximum altitude of 1,000 m; indoors (without corrosive gases or dust)
Weight 100 g max.
UL/cUL UL508C
International
standard EMC Directive :EN61800-3: 2004
EC directive
Low Voltage Directive :EN61800-5-1: 2003

EtherCAT Communications Specifications


Item Specifications
Communications standard IEC 61158 Type12, IEC 61800-7 CiA 402 drive profile
Physical layer 100BASE-TX (IEEE802.3)
RJ45 × 2 (shielded type)
Connector ECAT IN : EtherCAT input
ECAT OUT : EtherCAT output
Category 5 or higher (cable with double, aluminum tape and braided shielding) is
Communications media
recommended.
Communications distance Distance between nodes: 100 m max.
Fixed PDO mapping
Process data
PDO mapping
Mailbox (CoE) Emergency messages, SDO requests, SDO responses, and SDO information
Distributed clock FreeRun mode (asynchronous)
L/A IN (Link/Activity IN) × 1
L/A OUT (Link/Activity OUT) × 1
LED display
RUN × 1
ERR × 1
CiA402 drive profile Velocity mode

EtherCAT Communication Unit Version Information


As a Sysmac Device, the MX2-series Multi-function Compact Inverter is designed to provide optimal functionality and enhanced operability when
used in conjunction with a Machine Automation Control such as NJ series and the automation software Sysmac Studio.
Sysmac Device is a generic term for OMRON control devices such as an EtherCAT Slave, designed with unified communications specifications
and user interface specifications.

Unit Versions
Unit version
Unit Model
Ver.1.0 Ver1.1
EtherCAT Communication Unit for MX2-Series 3G3AX-MX2-ECT Supported Supported
Compatible Sysmac Studio version Version1.00 or higher* Version1.00 or higher

* The function that was enhanced by the upgrade for Unit version1.1 can not be used. For detail, refer to "Function Support by Unit Version".

Function Support by Unit Version


Unit
Model
Unit version 1.0 Unit version 1.1
Unit version
Item
Store-function of back-up number of parameters Not supported Supported
Initializing function as parameters. Not supported Supported

4
Multi-function Compact Inverter MX2-Series

MX2-Series CompoNet Communication Unit 3G3AX-MX2-CRT-E


This is the communication unit to connect the Multi-function Compact Inverter MX2 to CompoNet network.
Note: CompoNet Communication Unit 3G3AX-MX2-CRT-E can be used with the inverter 3G3MX2 of unit version 1.1 or higher.

Common Specification
Item Specification
Power supply Supplied from the inverter
Protective structure IP20
Ambient operating temperature − 10 to 55 °C (no icing or condensation)
Ambient storage temperature − 20 to 65 °C (no icing or condensation)
Ambient operating humidity 20 to 90%RH
Vibration resistance 5.9m/s2 (0.6G), 10 to 55Hz
Application environment At a maximum altitude of 1,000 m; indoors (without corrosive gases or dust)
Insulation resistance 500VAC (between isolated circuits)
Weight Approx. 170g
UL/cUL UL508
International standard EN61800-3: 2004 (2004/108/EC) Second environment, Category C3
EC directive
EN61800-5-1: 2007 (2006/95/EC) SELV

CompoNet Communications Specifications


Item Specification
Slave type Word Slave Unit (Mixed)
Certification CompoNet Conformance Tested
CompoNet Profile AC Drive (0x02)
Node Address 0 to 63, set with inverter parameter P190 or the rotary switches.
Communication power supply - (External power not required)
4 Mbps, 3 Mbps, 1.5 Mbps, 93.75 kbps. Automatically detecting baud rate of Master
Baud rates supported
Unit
Default Connection path Supported, set with inverter parameter P046
Basic Remote IO (Output assembly 20, Input assembly 70)
Extended Speed IO (21, 71)
Extended Speed and Torque Control (123, 173)
Special IO (100, 150)
Supported Assemblies
Extended Control IO (101, 151)
Extended Control IO and Multi function IO monitor (101, 153)
Flexible Format (139, 159)
Extended Speed and Acceleration Control (110, 111)
EDS file Depending on the MX2 inverter model

5
Multi-function Compact Inverter MX2-Series

MX2-Series DeviceNet Communication Unit 3G3AX-MX2-DRT-E


This is the communication unit to connect the Multi-function Compact Inverter MX2 to DeviceNet network.
Note: DeviceNet Communication Unit 3G3AX-MX2-DRT-E can be used with the inverter 3G3MX2 of unit version 1.1 or higher.

Common Specification
Item Specification
Power supply Supplied from the inverter
Protective structure IP20
Ambient operating temperature − 10 to 55 °C (no icing or condensation)
Ambient storage temperature − 20 to 65 °C( no icing or condensation)
Ambient operating humidity 20 to 90%RH
Vibration resistance 5.9m/s2 (0.6G), 10 to 55Hz
Application environment At a maximum altitude of 1,000 m; indoors (without corrosive gases or dust)
Insulation resistance 500VAC (between isolated circuits)
Weight Approx. 170g
UL/cUL UL508
International standard EN61800-3: 2004 (2004/108/EC) Second environment, Category C3
EC directive
EN61800-5-1: 2007 (2006/95/EC) SELV

DeviceNet Communications Specifications


Item Specification
Certification DeviceNet Conformance Tested
DeviceNet Profile AC Drive (0x02)
Remote I/O: Master-Slave connection
Poll
Bit-Strobe
Supported connections COS
Cyclic
Explicit Messages
Conform to DeviceNet specifications
Communication power supply 11 to 25VDC (MAX 50 mA, type 20 mA)
Unit device address range MAC ID 0 to 63, set with inverter parameter P192
4 Mbps, 3 Mbps, 1.5 Mbps, 93.75 kbps. Automatically detecting baud rate of Master
Baud rates supported
Unit
Default Connection path Supported, set with inverter parameter P046
Basic Remote IO (Output assembly 20, Input assembly 70)
Extended Speed IO (21, 71)
Extended Speed and Torque Control (123, 173)
Special IO (100, 150)
Extended Control IO (101, 151)
Supported Assemblies
Extended Control IO and Multi function IO monitor (101, 153)
Flexible Format (139, 159)
Extended Speed and Acceleration Control (110, 111)
In case the DeviceNet master is configured using user allocation, only the input /
output pairs can be configured.
EDS file Depending on the MX2 Inverter model

6
Multi-function Compact Inverter MX2-Series
Components and Functions
Inverter 3G3MX2
Modbus-RTU Termination resistor selector switch Safety function selector switch

OFF ON Disable Enable


(Factory default) (Factory default)

USB connector (mini-B)

Connector for optional board Connector for Digital Operator (RJ45)

EDM function selector switch

P1 terminal EDM output


Multi-function contact terminal block (Factory default)

Control circuit terminal block A

Control circuit terminal block B

CHARGE indicator
Main circuit terminal block

Name Function
Modbus-RTU Termination resistor Use this Terminal Resistor selector switch for RS-485 terminals on the control circuit terminal block. When this switch is turned
selector switch ON, the internal 200 Ω Resistor is connected.
Turn this switch ON when using the safety function. Turn OFF the power before turning this switch ON/OFF. For details, refer to
Safety function selector switch
USER’S MANUAL (Cat.No.I570).
Turn this switch ON when using the EDM output of the safety function. Turn OFF the power before turning this switch ON/
EDM function selector switch
OFF.For details, refer to USER’S MANUAL (Cat.No.I570).
Use this mini-B USB connector to connect a PC.
USB connector
Even when the Inverter is being operated by a PC, etc., via USB connection, it can still be operated using the Digital Operator.
Connector for Digital Operator Use this connector to connect the Digital Operator.
Connector for optional board Use this connector to mount the optional board. (Communications Units and other options can be connected.)
Control circuit terminal blocks A
These terminal blocks are used to connect various digital/analog input and output signals for inverter control, etc.
and B
Multi-function contact terminal block Use this SPDT contact terminal block for relay outputs.
Use this terminal block to connect an output to the motor and Braking Resistor, etc.
Main circuit terminal block
Also, use this terminal block to connect the inverter to the main power supply.
CHARGE indicator This LED indicator is lit if the DC voltage of the main circuit (between terminals P/+2 and N/-) remains approx. 45 V or above
(Charge indicator LED) after the power has been cut off. Before wiring, etc. confirm that the Charge LED indicator is turned OFF.
Note: This illustration shows the terminal block with the front cover removed.

EtherCAT Communication Unit 3G3AX-MX2-ECT


Status indicator Rotary switches
(L/A IN, L/A OUT, for node address
RUN, ERR) setting (× 10, × 1)

FG cable
Communications connector
(IN, OUT)

7
Multi-function Compact Inverter MX2-Series

CompoNet Communications Unit DeviceNet Communications Unit


3G3AX-MX2-CRT-E 3G3AX-MX2-DRT-E
Rotary switches for
Underside node address setting (× 10, × 1)
Underside

Option board connector Option board connector

LED indicators (MS, NS)


LED indicators (MS, NS)

Fieldbus connector Fieldbus connector

FG Cable
FG Cable

Connection Diagram
MC AX
MC AX
ON OFF
ELB
Single-phase MC
R/L1 (L1) *1
3-phase power U/T1
supply
S/L2
T/L3 (N) *1 V/T2
M
3~
24 VDC W/T3
If any source-logic external Shorting P24 Motor
output devices or external bar Shorting bar
PSC
power supply is used, refer DC reactor
+1
to User's Manual (I570) SC Remove the short
bar when connecting
P/+2 a DC reactor.
SC
Thermistor RB
S7/EB N/−

S6 MC Braking Resistor *2
S5/TH
MA Multi-function
Multi-function inputs S4/GS2 relay output
(7 contact inputs) MB
S3/GS1
S2
P2
S1

Power: 1/4 W min. 10 VDC power supply 10 VDC Multi-function


Resistance: 2 kΩ min. (7 mA Max.) FS P1/EDM outputs (2 outputs)
Analog voltage input
0 to 10 V (10 bits) FV
Analog current input PC
4 to 20 mA (10 bits) FI Approx.
10 kΩ
Approx. RS+
Pulse input 100 Ω
5 to 24 VDC SC Serial communication port
(32 kHz Max.) RP (RS-485/Modbus-RTU)

Analog voltage RS−


SC Terminal
output 0 to 10 V
(10 bits) AM Resistor
When using a Regenerative Braking Unit
Pulse output Terminal Resistor
0 to 10 VDC selector switch Regenerative Braking Resistor *2
(32 kHz Max.) MP SC Braking Unit *2
RB P P
SC
SC N/− N RB

SC
Optional board connector Ground to 100 Ω or less for 200-V class
Ground to 10 Ω or less for 400-V class
Communications Option Unit *2

*1 Connect to terminals L1 and N on a single-phase, 200-V Inverter (3G3MX2-AB@@@).


*2 Optional.

8
Multi-function Compact Inverter MX2-Series
Dimensions (Unit: mm)

3G3MX2-AB001 68 4.5 dia.


56
3G3MX2-AB002
3G3MX2-AB004
8.8.8.8.
3G3MX2-A2001
3G3MX2-A2002 118
3G3MX2-A2004 128
3G3MX2-A2007

5
Power supply Model W [mm] H [mm] D [mm] D1 [mm]
3G3MX2-AB001
1-phase 109 13.5
3G3MX2-AB002
D 200 V
3G3MX2-AB004 122.5 27
3G3MX2-A2001 68 128
109 13.5
3-phase 3G3MX2-A2002
D1
2.6 200 V 3G3MX2-A2004 122.5 27
3G3MX2-A2007 145.5 50

3G3MX2-AB007 108 Two, 4.5 dia.


3G3MX2-AB015 96
3G3MX2-AB022
3G3MX2-A2015 8.8.8.8.
3G3MX2-A2022
3G3MX2-A4004 118
3G3MX2-A4007 128
3G3MX2-A4015
3G3MX2-A4022
3G3MX2-A4030
5

Power supply Model W [mm] H [mm] D [mm] D1 [mm]


3G3MX2-AB007
1-phase
3G3MX2-AB015
200 V
3G3MX2-AB022 170.5 55
D
3-phase 3G3MX2-A2015
200 V 3G3MX2-A2022
108 128
3G3MX2-A4004 143.5 28
D1 3-phase 3G3MX2-A4007
400 V 3G3MX2-A4015
170.5 55
3G3MX2-A4022
4.4 3G3MX2-A4030

3G3MX2-A2037 140
Two, 4.5 dia.
3G3MX2-A4040 128

8.8.8.8.

118
128

170.5
Power supply Model W [mm] H [mm] D [mm] D1 [mm]
3-phase
3G3MX2-A2037
55 200 V
140 128 170.5 55
3-phase
3G3MX2-A4040
4.4
400 V

9
Multi-function Compact Inverter MX2-Series

3G3MX2-A2055 140
Two, 6 dia.
3G3MX2-A2075 122
3G3MX2-A4055
3G3MX2-A4075

8.8.8.8.

248
260

Power supply Model W [mm] H [mm] D [mm] D1 [mm]


155
3-phase 3G3MX2-A2055
200 V 3G3MX2-A2075
73.3 140 260 155 73.3
3-phase 3G3MX2-A4055
400 V 3G3MX2-A4075
6

3G3MX2-A2110 180 Two, 7 dia.


3G3MX2-A4110 160
3G3MX2-A4150

8.8.8.8.

284

296

Power supply Model W [mm] H [mm] D [mm] D1 [mm]


175
3-phase
3G3MX2-A2110
200 V
97 180 296 175 97
3-phase 3G3MX2-A4110
400 V 3G3MX2-A4150
5

3G3MX2-A2150 220 Two, 7 dia.


192

8.8.8.8.

336

350

175
Power supply Model W [mm] H [mm] D [mm] D1 [mm]
84
3-phase
3G3MX2-A2150 220 350 175 84
200 V
5

10
Multi-function Compact Inverter MX2-Series

EtherCAT Communication Unit


Rotary switches for node
3G3AX-MX2-ECT Status Indicator
address setting
67.6 44.8
28.4

60.0

27.9

FG cable
52.6

Communications
10.3 10.3 Communications
connector (IN) 26.4mm *
connector (OUT)
D*

28.2

FG cable

*After the EtherCAT Communication Unit is installed, dimension D of the inverter increases by 26.4 mm.
(Dimension D of the inverter varies depending on the capacity. Refer to the MX2-series USER'S MANUAL (Cat.No.I570))

CompoNet Communication Unit


44.8
3G3AX-MX2-CRT-E
67.6 28.4

60.0 60.7

52.6

26.4mm*
D*

9.4

31.3

* After the CompoNet Communication Unit is installed, dimension D of the inverter increases by 26.4 mm.
(Dimension D of the inverter varies depending on the capacity. Refer to the MX2-series USER'S MANUAL (Cat.No.I570))

DeviceNet Communication Unit


44.8
3G3AX-MX2-DRT-E
67.6 28.4

60.0

52.6

26.4mm*
D*

18.7

31.3

* After the DeviceNet Communication Unit is installed, dimension D of the inverter increases by 26.4 mm.
(Dimension D of the inverter varies depending on the capacity. Refer to the MX2-series USER'S MANUAL (Cat.No.I570))

11
MEMO

12
Ordering Information
System Configuration ....................................................................................14
Interpreting Model Numbers..........................................................................15
Ordering Information......................................................................................15
3G3MX2 Inverter Models .......................................................................................15
Communication Unit ..............................................................................................15
Related Options .....................................................................................................16
Recommended EtherCAT Communications Cables ...........................................21
Software..................................................................................................................22
Related Manuals .............................................................................................22
Multi-function Compact Inverter 3G3MX2
System Configuration

Machine Automation Programmable Programmable Programmable Built-in pulse I/O function type
Controller Controller Controller Controller CP1H/CP1L
NJ-series CJ2/CJ1 CJ2/CJ1 CS1

EtherCAT

Sysmac Studio Position Control Unit with CompoNet Master Unit DeviceNet Master Unit CX-One
EtherCAT interface CJ1W-CRM21/ CJ1W-DRM21/
CJ1W-NC@81/NC@82 CS1W-CRM21 CS1W-DRM21-V1

EtherCAT

CompoNet
DeviceNet
Modbus I/O

MX2-series
3G3MX2-@@@@@
USB

Digital operator extension cable Digital operator


3G3AX-OPCN1/OPCN3 3G3AX-OP01
CX-One

Option communication unit

3G3AX-MX2-ECT
3G3AX-MX2-CRT-E
3G3AX-MX2-DRT-E

AC reactor Input noise filter


Output noise filter
3G3AX-AL@@@@@ 3G3AX-NFI@@
3G3AX-NFO@@ Regenerative braking units
3G3AX-RBU@@

DC reactor
3G3AX-DL@@@@

EMC-compatible noise filter Radio noise filter Radio noise filter


Schaffner products 3G3AX-ZLC@ 3G3AX-ZLC@
Braking resistor
3G3AX-RB@@@@@

R S T Power supply
3-phase 200VAC 3-phase
M
( 3-phase 400VAC
1-phase 200VAC ) induction
motor

14
Multi-function Compact Inverter 3G3MX2
Interpreting Model Numbers

1 2
3G3MX2

1) Voltage class 2) Max. applicable motor capacity (CT)


B 1-phase 200 VAC (200-V class) 001 0.1 kW
2 3-phase 200 VAC (200-V class) 002 0.2 kW
4 3-phase 400 VAC (400-V class) 004 0.4 kW
007 0.75 kW
015 1.5 kW
022 2.2 kW
030 3.0 kW
037 3.7 kW
040 4.0 kW
055 5.5 kW
075 7.5 kW
110 11 kW
150 15 kW

Ordering Information
3G3MX2 Inverter Models
Max. applicable motor capacity
Rated voltage Enclosure ratings Model
CT: Heavy load VT: Light load
0.1kW 0.2 kW 3G3MX2-A2001
0.2 kW 0.4 kW 3G3MX2-A2002
0.4 kW 0.75 kW 3G3MX2-A2004
0.75 kW 1.1 kW 3G3MX2-A2007
1.5 kW 2.2 kW 3G3MX2-A2015
3-phase 200 VAC IP20 2.2 kW 3.0 kW 3G3MX2-A2022
3.7 kW 5.5 kW 3G3MX2-A2037
5.5 kW 7.5 kW 3G3MX2-A2055
7.5 kW 11 kW 3G3MX2-A2075
11 kW 15 kW 3G3MX2-A2110
15 kW 18.5 kW 3G3MX2-A2150
0.4 kW 0.75 kW 3G3MX2-A4004
0.75 kW 1.5 kW 3G3MX2-A4007
1.5 kW 2.2 kW 3G3MX2-A4015
2.2 kW 3.0 kW 3G3MX2-A4022
3.0 kW 4.0 kW 3G3MX2-A4030
3-phase 400 VAC IP20
4.0 kW 5.5 kW 3G3MX2-A4040
5.5 kW 7.5 kW 3G3MX2-A4055
7.5 kW 11 kW 3G3MX2-A4075
11 kW 15 kW 3G3MX2-A4110
15 kW 18.5 kW 3G3MX2-A4150
0.1 kW 0.2 kW 3G3MX2-AB001
0.2 kW 0.4 kW 3G3MX2-AB002
0.4 kW 0.55 kW 3G3MX2-AB004
1-phase 200 VAC IP20
0.75 kW 1.1 kW 3G3MX2-AB007
1.5 kW 2.2 kW 3G3MX2-AB015
2.2 kW 3.0 kW 3G3MX2-AB022

Communication Unit
Name Model
EtherCAT Communication Unit 3G3AX-MX2-ECT
CompoNet Communication Unit 3G3AX-MX2-CRT-E
DeviceNet Communication Unit 3G3AX-MX2-DRT-E Available soon

15
Multi-function Compact Inverter 3G3MX2
Related Options
Name Specifications Model
General purpose with Braking resistor 3G3AX-RBU21
3-phase 200 VAC
Regenerative Braking Units High Regeneration purpose with Braking resistor 3G3AX-RBU22
3-phase 400 VAC General purpose with Braking resistor 3G3AX-RBU41
Resistor 120 W, 180 Ω 3G3AX-RBA1201
Resistor 120 W, 100 Ω 3G3AX-RBA1202
Compact type
Resistor 120 W, 5 Ω 3G3AX-RBA1203
Resistor 120 W, 35 Ω 3G3AX-RBA1204
Resistor 200 W, 180 Ω 3G3AX-RBB2001
Braking Resistor Resistor 200 W, 100 Ω 3G3AX-RBB2002
Standard type
Resistor 300 W, 50 Ω 3G3AX-RBB3001
Resistor 400 W, 35 Ω 3G3AX-RBB4001
Resistor 400 W, 50 Ω 3G3AX-RBC4001
Medium capacity type Resistor 600 W, 35 Ω 3G3AX-RBC6001
Resistor 1200 W, 17 Ω 3G3AX-RBC12001

Regenerative Braking Unit and Braking Resistor Combination


Regenerative
Inverter Usage conditions Braking resistor Restrictions
braking unit
Connection Allowable Min.
Max.applicable Approximate configuration
%ED *1 Number Number continuous connectable
Voltage motor capacity Model braking torque Model Model
[%] of units of units braking resistance
(kW) [% *2 ]
time(s) [Ω]

3G3MX2-A2001 3.0% 220% 3G3AX-RBA1201 1 1 20 100


0.1 Built-in Inverter
3G3MX2-AB001 10.0% 220% 3G3AX-RBB2001 1 1 30 100

3G3MX2-A2002 3.0% 220% 3G3AX-RBA1201 1 1 20 100


0.2 Built-in Inverter
3G3MX2-AB002 10.0% 220% 3G3AX-RBB2001 1 1 30 100

3G3MX2-A2004 3.0% 220% 3G3AX-RBA1201 1 1 20 100


0.4 Built-in Inverter
3G3MX2-AB004 10.0% 220% 3G3AX-RBB2001 1 1 30 100

3G3MX2-A2007 3.0% 120% 3G3AX-RBA1201 1 1 20 50


0.75 Built-in Inverter
3G3MX2-AB007 10.0% 120% 3G3AX-RBB2001 1 1 30 50

3G3MX2-A2015 2.5% 110% 3G3AX-RBA1202 1 1 12 50


1.5 Built-in Inverter
3G3MX2-AB015 10.0% 215% 3G3AX-RBC4001 1 1 10 50

3G3MX2-A2022 3.0% 150% 3G3AX-RBB3001 1 1 30 35


200-V 2.2 Built-in Inverter
3G3MX2-AB022 10.0% 150% 3G3AX-RBC4001 1 1 10 35
Class
3.0% 125% 3G3AX-RBB4001 1 1 20 35
3.7 3G3MX2-A2037 Built-in Inverter
10.0% 125% 3G3AX-RBC6001 1 1 10 35
3.0% 120% 3G3AX-RBB3001 2 2 30 20
5.5 3G3MX2-A2055 Built-in Inverter
10.0% 120% 3G3AX-RBC4001 2 2 10 20

3.0% 125% 3G3AX-RBB4001 2 2 20 17


7.5 3G3MX2-A2075 Built-in Inverter
10.0% 125% 3G3AX-RBC6001 2 2 10 17
3.0% 90% 3G3AX-RBC12001 1 1 10 17
Built-in Inverter
11 3G3MX2-A2110 10.0% 90% 3G3AX-RBC12001 1 1 10 17

10.0% 125% 3G3AX-RBU23 1 3G3AX-RBC6001 3 14 10 4


3.0% 110% 3G3AX-RBB3001 5 7 30 10
15 3G3MX2-A2150 Built-in Inverter
10.0% 110% 3G3AX-RBC4001 5 7 10 10

16
Multi-function Compact Inverter 3G3MX2

Regenerative
Inverter Usage conditions Braking resistor Restrictions
braking unit
Connection Allowable Min.
Max.applicable Approximate configuration
%ED *1 Number Number continuous connectable
Voltage motor capacity Model braking torque Model Model
[%] of units of units braking resistance
(kW) [% *2 ]
time(s) [Ω]
3.0% 220% 3G3AX-RBA1201 2 3 20 180
0.4 3G3MX2-A4004 Built-in Inverter
10.0% 220% 3G3AX-RBB2001 2 3 30 180
3.0% 220% 3G3AX-RBA1201 2 3 20 180
0.75 3G3MX2-A4007 Built-in Inverter
10.0% 220% 3G3AX-RBB2001 2 3 30 180
3.0% 120% 3G3AX-RBA1201 2 3 20 180
1.5 3G3MX2-A4015 Built-in Inverter
10.0% 120% 3G3AX-RBB2001 2 3 30 180
2.5% 150% 3G3AX-RBA1202 2 3 12 100
2.2 3G3MX2-A4022 Built-in Inverter
10.0% 220% 3G3AX-RBC4001 2 3 10 100
2.5% 110% 3G3AX-RBA1202 2 3 12 100
3.0 3G3MX2-A4030 Built-in Inverter
10.0% 215% 3G3AX-RBC4001 2 3 10 100
400-V 3.0% 165% 3G3AX-RBB3001 2 3 30 100
Class 4.0 3G3MX2-A4040 Built-in Inverter
10.0% 165% 3G3AX-RBC4001 2 3 10 100
3.0% 120% 3G3AX-RBB3001 2 3 30 70
5.5 3G3MX2-A4055 Built-in Inverter
10.0% 120% 3G3AX-RBC4001 2 3 10 70
3.0% 125% 3G3AX-RBB4001 2 3 20 70
7.5 3G3MX2-A4075 Built-in Inverter
10.0% 125% 3G3AX-RBC6001 2 3 10 70
3.0% 85% 3G3AX-RBB4001 2 3 20 70
Built-in Inverter
10.0% 85% 3G3AX-RBC6001 2 3 10 70
11 3G3MX2-A4110
3G3AX-RBU41
10.0% 120% 1 3G3AX-RBC4001 4 15 10 34
*3
3.0% 125% 3G3AX-RBB4001 4 5 20 35
15 3G3MX2-A4150 Built-in Inverter
10.0% 125% 3G3AX-RBC6001 4 5 10 35

*1 %ED shows the ratio that can be used for braking (deceleration time) among operating time of one task period.
*2 Approximate breaking torque is shown in % of rating torque of the motor (100%).
*3 Please remove the built-in resistor.

Connection configuration
TYPE TYPE

Inverter Resistor Inverter


Resistor
only Five
1 only One R Resistor 7 R R R R R
units in
unit
parallel

Resistor Inverter Inverter


only Two
2 R R One R R R
units in
parallel braking
14 unit Three Braking unit
resistors Voltage (Resistor
Inverter
in parallel detection mounted
Resistor externally)
only Two R
3
units in
series R
Inverter
One
braking R R
Resistor unit Two
only Two Inverter resistors
parallel in parallel R R
R R 15
units connected
5 connected in series to
in series to two other Braking unit
two other R R Voltage (Resistor
parallel detection
parallel mounted
units
units externally)

17
Multi-function Compact Inverter 3G3MX2

Specifications of Inverter
Name Model
Voltage class CT: Heavy load VT: Light load
0.1 kW 0.2 kW
0.2 kW 0.4 kW
0.4 kW 0.75 kW
3G3AX-ZCL2
0.75 kW 1.1 kW
1.5 kW 2.2 kW
3-phase 200 VAC 2.2 kW 3.0 kW
3.7 kW 5.5 kW
3G3AX-ZCL1 (3G3AX-ZCL2)
5.5 kW 7.5 kW
7.5 kW 11 kW
11 kW 15 kW 3G3AX-ZCL1
15 kW 18.5 kW
0.1 kW 0.2 kW
0.2 kW 0.4 kW
Radio Noise Filter 0.4 kW 0.55 kW
1-phase 200 VAC 3G3AX-ZCL2
0.75 kW 1.1 kW
1.5 kW 2.2 kW
2.2 kW 3.0 kW
0.4 kW 0.75 kW
0.75 kW 1.5 kW
1.5 kW 2.2 kW
2.2 kW 3.0 kW 3G3AX-ZCL2 (3G3AX-ZCL1)
3.0 kW 4.0 kW
3-phase 400 VAC
4.0 kW 5.5 kW
5.5 kW 7.5 kW
7.5 kW 11 kW
11 kW 15 kW 3G3AX-ZCL1
15 kW 18.5 kW
0.1 kW 0.2 kW
0.2 kW 0.4 kW 3G3AX-NFI21
0.4 kW 0.75 kW
0.75 kW 1.1 kW 3G3AX-NFI22
1.5 kW 2.2 kW
3G3AX-NFI23
3-phase 200 VAC 2.2 kW 3.0 kW
3.7 kW 5.5 kW 3G3AX-NFI24
5.5 kW 7.5 kW 3G3AX-NFI25
7.5 kW 11 kW 3G3AX-NFI26
11 kW 15 kW 3G3AX-NFI27
15 kW 18.5 kW 3G3AX-NFI28
0.1 kW 0.2 kW
3G3AX-NFI21
0.2 kW 0.4 kW
Input Noise Filter 0.4 kW 0.55 kW 3G3AX-NFI22
1-phase 200 VAC
0.75 kW 1.1 kW 3G3AX-NFI23
1.5 kW 2.2 kW 3G3AX-NFI23 *
2.2 kW 3.0 kW 3G3AX-NFI24
0.4 kW 0.75 kW
0.75 kW 1.5 kW 3G3AX-NFI41
1.5 kW 2.2 kW
2.2 kW 3.0 kW
3G3AX-NFI42
3.0 kW 4.0 kW
3-phase 400 VAC
4.0 kW 5.5 kW
3G3AX-NFI43
5.5 kW 7.5 kW
7.5 kW 11 kW 3G3AX-NFI44
11 kW 15 kW 3G3AX-NFI45
15 kW 18.5 kW 3G3AX-NFI46
* Only the CT rating is supported.

18
Multi-function Compact Inverter 3G3MX2

Specifications of Inverter
Name Model
Voltage class CT: Heavy load VT: Light load
0.1 kW 0.2 kW
0.2 kW 0.4 kW
0.4 kW 0.75 kW
0.75 kW 1.1 kW
1.5 kW 2.2 kW
3-phase 200 VAC 2.2 kW 3.0 kW
3.7 kW 5.5 kW
5.5 kW 7.5 kW
7.5 kW 11 kW
11 kW 15 kW
15 kW 18.5 kW
0.1 kW 0.2 kW
0.2 kW 0.4 kW
Schaffner product will be
EMC-compatible Noise Filter 0.4 kW 0.55 kW
1-phase 200 VAC supported in future.
0.75 kW 1.1 kW
1.5 kW 2.2 kW
2.2 kW 3.0 kW
0.4 kW 0.75 kW
0.75 kW 1.5 kW
1.5 kW 2.2 kW
2.2 kW 3.0 kW
3.0 kW 4.0 kW
3-phase 400 VAC
4.0 kW 5.5 kW
5.5 kW 7.5 kW
7.5 kW 11 kW
11 kW 15 kW
15 kW 18.5 kW
0.1 kW 0.2 kW
0.2 kW 0.4 kW 3G3AX-NFO01
0.4 kW 0.75 kW
0.75 kW 1.1 kW
3G3AX-NFO02
1.5 kW 2.2 kW
3-phase 200 VAC 2.2 kW 3.0 kW
3G3AX-NFO03
3.7 kW 5.5 kW
5.5 kW 7.5 kW
3G3AX-NFO04
7.5 kW 11 kW
11 kW 15 kW 3G3AX-NFO05
15 kW 18.5 kW 3G3AX-NFO06
0.1 kW 0.2 kW
3G3AX-NFO01
0.2 kW 0.4 kW
Output Noise Filter 0.4 kW 0.55 kW
1-phase 200 VAC 3G3AX-NFO02
0.75 kW 1.1 kW
1.5 kW 2.2 kW
3G3AX-NFO03
2.2 kW 3.0 kW
0.4 kW 0.75 kW
3G3AX-NFO01
0.75 kW 1.5 kW
1.5 kW 2.2 kW
2.2 kW 3.0 kW 3G3AX-NFO02
3.0 kW 4.0 kW
3-phase 400 VAC
4.0 kW 5.5 kW
5.5 kW 7.5 kW 3G3AX-NFO03
7.5 kW 11 kW
11 kW 15 kW
3G3AX-NFO04
15 kW 18.5 kW

19
Multi-function Compact Inverter 3G3MX2

Specifications of Inverter
Name Model
Voltage class CT: Heavy load VT: Light load
0.1 kW 0.2 kW 3G3AX-DL2002
0.2 kW 0.4 kW 3G3AX-DL2004
0.4 kW 0.75 kW 3G3AX-DL2007
0.75 kW 1.1 kW 3G3AX-DL2015
1.5 kW 2.2 kW 3G3AX-DL2022
3-phase 200 VAC 2.2 kW 3.0 kW 3G3AX-DL2037
3.7 kW 5.5 kW 3G3AX-DL2055
5.5 kW 7.5 kW 3G3AX-DL2075
7.5 kW 11 kW 3G3AX-DL2110
11 kW 15 kW 3G3AX-DL2150
15 kW 18.5 kW 3G3AX-DL2220
0.1 kW 0.2 kW 3G3AX-DL2002
0.2 kW 0.4 kW 3G3AX-DL2004
DC Reactor 0.4 kW 0.55 kW 3G3AX-DL2007
1-phase 200 VAC
0.75 kW 1.1 kW 3G3AX-DL2015
1.5 kW 2.2 kW 3G3AX-DL2022
2.2 kW 3.0 kW 3G3AX-DL2037
0.4 kW 0.75 kW 3G3AX-DL4007
0.75 kW 1.5 kW 3G3AX-DL4015 *
1.5 kW 2.2 kW 3G3AX-DL4022
2.2 kW 3.0 kW
3G3AX-DL4037
3.0 kW 4.0 kW
3-phase 400 VAC
4.0 kW 5.5 kW 3G3AX-DL4055
5.5 kW 7.5 kW 3G3AX-DL4075 *
7.5 kW 11 kW 3G3AX-DL4110 *
11 kW 15 kW 3G3AX-DL4150
15 kW 18.5 kW 3G3AX-DL4220
0.1 kW 0.2 kW
0.2 kW 0.4 kW
3G3AX-AL2025
0.4 kW 0.75 kW
0.75 kW 1.1 kW
1.5 kW 2.2 kW
3G3AX-AL2055
3-phase 200 VAC 2.2 kW 3.0 kW
3.7 kW 5.5 kW 3G3AX-AL2110
5.5 kW 7.5 kW 3G3AX-AL2110 *
7.5 kW 11 kW 3G3AX-AL2220
11 kW 15 kW 3G3AX-AL2220 *
15 kW 18.5 kW 3G3AX-AL2330
0.1 kW 0.2 kW
0.2 kW 0.4 kW
3G3AX-AL2025
AC Reactor 0.4 kW 0.55 kW
1-phase 200 VAC
0.75 kW 1.1 kW
1.5 kW 2.2 kW 3G3AX-AL2055 *
2.2 kW 3.0 kW 3G3AX-AL2110
0.4 kW 0.75 kW
3G3AX-AL4025
0.75 kW 1.5 kW
1.5 kW 2.2 kW
2.2 kW 3.0 kW 3G3AX-AL4055
3.0 kW 4.0 kW
3-phase 400 VAC
4.0 kW 5.5 kW 3G3AX-AL4110
5.5 kW 7.5 kW 3G3AX-AL4110 *
7.5 kW 11 kW 3G3AX-AL4220
11 kW 15 kW 3G3AX-AL4220 *
15 kW 18.5 kW 3G3AX-AL4330
* Only the CT rating is supported.
Note: When using the Inverter for light load rating, select the model with one size larger capacity (rated current).

20
Multi-function Compact Inverter 3G3MX2

External Digital Operator


Name Cable length(m) Model
Digital Operator − 3G3AX-OP01
1m 3G3AX-OPCN1
Connection cable
3m 3G3AX-OPCN3

Recommended EtherCAT Communications Cables


Category 5 or higher (100BASE-TX) straight cable with double shielding (aluminum tape and braided shielding) is recommended.

Cabel with Connectors


Wire Gauge and Number of Pairs: AWG22, 2-pair Cable
Cable
Item Appearance Recommended manufacturer Model
length(m)
0.3 XS5W-T421-AMD-K
0.5 XS5W-T421-BMD-K
Cable with Connectors on Both Ends 1 XS5W-T421-CMD-K
OMRON
(RJ45/RJ45) 2 XS5W-T421-DMD-K
5 XS5W-T421-GMD-K
10 XS5W-T421-JMD-K
0.3 XS5W-T421-AMC-K
0.5 XS5W-T421-BMC-K
Cable with Connectors on Both Ends 1 XS5W-T421-CMC-K
OMRON
(M12/RJ45) 2 XS5W-T421-DMC-K
5 XS5W-T421-GMC-K
10 XS5W-T421-JMC-K
Note: The cable length 0.3, 0.5, 1, 2, 3, 5, 10 and 15m are available. For details, refer to Cat.No.G019.

Cables / Connectors
Wire Gauge and Number of Pairs: AWG24, 4-pair Cable
Item Appearance Recommended manufacturer Model
− Tonichi Kyosan Cable, Ltd. NETSTAR-C5E SAB 0.5 x 4P *
Cables − Kuramo Electric Co. KETH-SB *
− SWCC Showa Cable Systems Co. FAE-5004 *
RJ45 Connectors − Panduit Corporation MPS588 *
* We recommend you to use above cable and connector together.

Wire Gauge and Number of Pairs: AWG22, 2-pair Cable


Item Appearance Recommended manufacturer Model
Cables − Kuramo Electric Co. KETH-PSB-OMR *

RJ45 Assembly Connector OMRON XS6G-T421-1 *

* We recommend you to use above cable and connector together.


Note: Connect both ends of cable shielded wires to the connector hoods.

21
Multi-function Compact Inverter 3G3MX2

Software
How to Select Required Support Software for Your Controller
The required Support Software depends on the Controller to connect. Please check the following table when purchasing the Support Software.

Item Omron PLC System Omron Machine Automation Controller System


Controller CS, CJ, CP, and other series NJ-series

Inverter MX2-series
Inverter Inverter MX2-series with CompoNet Communication Unit Inverter MX2-series with EtherCAT Communication Unit
Inverter MX2-series with DeviceNet Communication Unit

Software FA Integrated Tool Package CX-One Automation Software Sysmac Studio

FA Integrated Tool Package CX-One

Product name Specifications Number of Model Standards


Media
licenses
The CX-One is a comprehensive software package
that integrates Support Software for OMRON PLCs
and components.

CX-One runs on following OS.


FA Integrated Tool 1 license DVD
OS: Windows XP (Service Pack 3 or higher), Vista or 7 CXONE-AL01D-V4 −
Package CX-One Ver. 4.@ Note: Except for Windows XP 64-bit version. *1 *2

CX-One Version.4.@ includes CX-Drive Ver.2.@.


For details, refer to the CX-One catalog (Cat. No.
R134)
*1 Multi licenses are available for the CX-One (3, 10, 30, or 50 licenses).
*2 The CX-One is also available on CD (CXONE-AL@@C-V4).

Automation Software Sysmac Studio


Please purchase a DVD and required number of licenses the first time you purchase the Sysmac Studio. DVDs and licenses are available
individually. Each model of licenses does not include any DVD.

Product name Specifications Number of Model Standards


Media
licenses
The Sysmac Studio provides an integrated
development environment to set up, program, debug,
and maintain NJ-series Controllers and other Machine
Automation Controllers, as well as EtherCAT slaves. −
DVD SYSMAC-SE200D −
(Media only)
Sysmac Studio runs on the following OS.
Windows XP (Service Pack 3 or higher, 32-bit version)/
Sysmac Studio Vista (32-bit version) / 7 (32-bit/64-bit version)
Standard Edition Ver.1.@@
The Sysmac Studio Standard Edition DVD includes
Support Software to set up EtherNet/IP Units,
DeviceNet slaves, Serial Communications Units, and 1 license
Support Software for creating screens on HMIs (CX- − SYSMAC-SE201L −
*
Designer).
For details, refer to the Sysmac Integrated Catalogue
(P072).
* Multi licenses are available for the Sysmac Studio (3, 10, 30, or 50 licenses).

Related Manuals
Man. No. Model Manual
I570 3G3MX2 Multi-function Compact Inverter MX2-series USER'S MANUAL
I574 3G3AX-MX2-ECT EtherCAT Communication Unit USER'S MANUAL
I581 3G3AX-MX2-DRT-E * MX2 series DeviceNet Communication Unit USER'S MANUAL
I582 3G3AX-MX2-CRT-E MX2 series CompoNet Communication Unit USER'S MANUAL
W487 CJ1W-NC@81/CJ1W-NC@82 CJ-series Position Control Unit Operation Manual
W463 CXONE-AL@@C/D-V@ CX-One FA Integrated Tool Package Setup Manual
W446 CXONE-AL@@C-V@/-AL@@D-V@ CX-Programmer Operation Manual
W453 CXONE-AL@C/D-V@/WS02-DRVC01 CX-Drive OPERATION MANUAL
W504 SYSMAC-SE2@@@ Sysmac Studio Version 1 Operation Manual
* MX2-series DeviceNet communication unit is available soon.

22
Read and Understand this Catalog
Please read and understand this catalog before purchasing the product. Please consult your OMRON representative if you have
any questions or comments.

Warranty and Limitations of Liability


WARRANTY
OMRON's exclusive warranty is that the products are free from defects in materials and workmanship for a period of one year
(or other period if specified) from date of sale by OMRON.
OMRON MAKES NO WARRANTY OR REPRESENTATION, EXPRESS OR IMPLIED, REGARDING NON-INFRINGEMENT,
MERCHANTABILITY, OR FITNESS FOR PARTICULAR PURPOSE OF THE PRODUCTS. ANY BUYER OR USER
ACKNOWLEDGES THAT THE BUYER OR USER ALONE HAS DETERMINED THAT THE PRODUCTS WILL SUITABLY MEET
THE REQUIREMENTS OF THEIR INTENDED USE. OMRON DISCLAIMS ALL OTHER WARRANTIES, EXPRESS OR
IMPLIED.

LIMITATIONS OF LIABILITY
OMRON SHALL NOT BE RESPONSIBLE FOR SPECIAL, INDIRECT, OR CONSEQUENTIAL DAMAGES, LOSS OF PROFITS,
OR COMMERCIAL LOSS IN ANY WAY CONNECTED WITH THE PRODUCTS, WHETHER SUCH CLAIM IS BASED ON
CONTRACT, WARRANTY, NEGLIGENCE, OR STRICT LIABILITY.
In no event shall the responsibility of OMRON for any act exceed the individual price of the product on which liability is asserted.
IN NO EVENT SHALL OMRON BE RESPONSIBLE FOR WARRANTY, REPAIR, OR OTHER CLAIMS REGARDING THE
PRODUCTS UNLESS OMRON'S ANALYSIS CONFIRMS THAT THE PRODUCTS WERE PROPERLY HANDLED, STORED,
INSTALLED, AND MAINTAINED AND NOT SUBJECT TO CONTAMINATION, ABUSE, MISUSE, OR INAPPROPRIATE
MODIFICATION OR REPAIR.

Application Considerations
SUITABILITY FOR USE
OMRON shall not be responsible for conformity with any standards, codes, or regulations that apply to the combination of
products in the customer's application or use of the products.
Take all necessary steps to determine the suitability of the product for the systems, machines, and equipment with which it will
be used.
Know and observe all prohibitions of use applicable to this product.
NEVER USE THE PRODUCTS FOR AN APPLICATION INVOLVING SERIOUS RISK TO LIFE OR PROPERTY WITHOUT
ENSURING THAT THE SYSTEM AS A WHOLE HAS BEEN DESIGNED TO ADDRESS THE RISKS, AND THAT THE OMRON
PRODUCTS ARE PROPERLY RATED AND INSTALLED FOR THE INTENDED USE WITHIN THE OVERALL EQUIPMENT OR
SYSTEM.

PROGRAMMABLE PRODUCTS
OMRON shall not be responsible for the user’s programming of a programmable product, or any consequence thereof.

Disclaimers
CHANGE IN SPECIFICATIONS
Product specifications and accessories may be changed at any time based on improvements and other reasons.
It is our practice to change model numbers when published ratings or features are changed, or when significant construction
changes are made. However, some specifications of the products may be changed without any notice. When in doubt, special
model numbers may be assigned to fix or establish key specifications for your application on your request. Please consult with
your OMRON representative at any time to confirm actual specifications of purchased products.

DIMENSIONS AND WEIGHTS


Dimensions and weights are nominal and are not to be used for manufacturing purposes, even when tolerances are shown.

PERFORMANCE DATA
Performance data given in this catalog is provided as a guide for the user in determining suitability and does not constitute a
warranty. It may represent the result of OMRON’s test conditions, and the users must correlate it to actual application
requirements. Actual performance is subject to the OMRON Warranty and Limitations of Liability.
OMRON Corporation OMRON ELECTRONICS LLC
One Commerce Drive Schaumburg,
Authorized Distributor:
Industrial Automation Company
Control Devices Division H.Q. IL 60173-5302 U.S.A.
Automation & Drive Division Tel: (1) 847-843-7900/Fax: (1) 847-843-7787
Drive Department 1
Shiokoji Horikawa, Shimogyo-ku, OMRON ASIA PACIFIC PTE. LTD.
Kyoto, 600-8530 Japan No. 438A Alexandra Road # 05-05/08 (Lobby 2),
Tel: (81) 75-344-7173/Fax: (81) 75-344-7149 Alexandra Technopark, Singapore 119967
Tel: (65) 6835-3011/Fax: (65) 6835-2711

Regional Headquarters OMRON (CHINA) CO., LTD.


OMRON EUROPE B.V. Room 2211, Bank of China Tower, © OMRON Corporation 2009 All Rights Reserved.
Wegalaan 67-69-2132 JD Hoofddorp 200 Yin Cheng Zhong Road, In the interest of product improvement,
The Netherlands PuDong New Area, Shanghai, 200120, China specifications are subject to change without notice.
Tel: (31)2356-81-300/Fax: (31)2356-81-388 Tel: (86) 21-5037-2222/Fax: (86) 21-5037-2200
OMRON Industrial Automation Global: www.ia.omron.com Cat. No. I916-E1-02 0412(0909)

You might also like