Hybrid Combiner 2:1 698 - 2690 MHZ 2 X 60 W: Excellent Intermodulation Performance
Hybrid Combiner 2:1 698 - 2690 MHZ 2 X 60 W: Excellent Intermodulation Performance
Hybrid Combiner 2:1 698 - 2690 MHZ 2 X 60 W: Excellent Intermodulation Performance
Port 2
Technical Data
Type No. 782 10504
Frequency range 698 – 2690 MHz
Attenuation
Port 1 ↔ Port 3 3.1 ±0.5 dB
Port 2 ↔ Port 3 3.1 ±0.5 dB
Port 1 ↔ Port 2 > 23 dB*
VSWR (all ports) < 1.2 (698 – 2170 MHz) / < 1.25 (2170 – 2690 MHz)
Impedance 50 Ω
Input power
Port 1 < 60 W
Port 2 < 60 W
Intermodulation products < –160 dBc (3 rd order; with 2 x 20 W)
Temperature range –40 … +55 °C
Connectors 7-16 female (long neck)
Application Indoor or outdoor (IP 66)
DC/AISG transparency
Port 1 ↔ Port 3 By-pass (max. 2500 mA)
Port 2 ↔ Port 3 Stop
Mounting Wall mounting: With 4 screws (max. 8 mm diameter)
Mast mounting: With additional clamp set
Weight 4.3 kg
Packing size 385 x 345 x 168 mm
Dimensions (w x h x d) 264 x 203 x 72.5 mm
(without connectors, without mounting brackets)
Note:
The input power rating of 60 W per port is specified at an ambient temperature
of +55 °C with the combiner mounted vertically, without additional cooling, and
while respecting the safety standard EN IEC 60950 (max. surface temperature Accessories (order separately)
+90 °C).
Clamp Set
Subject to alteration.
If used at a lower ambient temperature, then a higher input power in accor- Clamp set
dance with the following table is possible: Type No. suitable for mast
diameter of
Max. input power per port 734 360 34 – 60 mm
+25 °C 80 W 85 W
Please note:
As a result of more stringent legal regulations and judgements regarding
product liability, we are obliged to point out certain risks that may arise
when products are used under extraordinary operating conditions.
Extraordinary operating conditions, such as heavy icing or exceptional dyna-
Subject to alteration.
mic stress (e.g. strain caused by oscillating support structures), may result in
the breakage of a mast mounted device or even cause it to fall to the ground.
These facts must be considered during the site planning process.
The Hybrid Combiner is designed to operate under the environmental condi-
tions as described in ETS 300 019-1-4 class 4.1 E and have passed environ-
mental tests as recommended in ETS 300 019-2-4.
The installation team must be properly qualified and also be familiar with
the relevant national safety regulations.
936.3737
Page 2 of 2 782 10504 All specifications are subject to change without notice.
The latest specifications are available at www.kathreinusa.com
Kathrein USA Greenway Plaza II, 2400 Lakeside Blvd., Suite 650, Richardson TX 75082
Phone: 214.238.8800 Fax: 214.238.8801 Email: info@kathrein.com