Multi-Functional Main AC Switch For Rolling Stock: Type MACS
Multi-Functional Main AC Switch For Rolling Stock: Type MACS
Multi-Functional Main AC Switch For Rolling Stock: Type MACS
APPLICATIONS
• Switching and protection of main and auxiliary
electric circuits for locomotives, trains and EMUs
running on 15 kVAC or/and 25 kVAC networks.
MAIN FEATURES
• Compact multi-functional switch including: AC
circuit-breaker, earthing switch (option) and
surge arrester (option) on a single support of
940 mm x 430 mm.
/// AC CIRCUIT-BREAKER
MAIN BENEFITS
 Indoor or outdoor installation
 Vertical or horizontal mounting
MAIN BENEFITS
 High safety thanks to the automatic opening through spring release in case of interruption of supply
voltage (no need of stored auxiliary electrical energy
 Compliant to LOC & PAS TSI (Technical specification for interoperability), 1302/2014/EU.
 High mecanical durability: > 250'000 operations
 Low height: 563 mm (for Uimp = 125 kV) above the roof and 140 mm below the roof
 Low weight: < 100 kg for the AC circuit-breaker
Auxiliary contacts
Type of contacts (5) Potential free
Rated voltage [VDC] 24 to 110
Conventional thermal current Ith [A] 10
- AC-15 230 VAC 1.0 A
Switching categories according to EN60947 (silver contacts)
- DC-13 110 VDC 0.5 A
≥ 10 (silver contacts) or
Minimum let-through current at 24 VDC (6) [mA]
4 ≤ I < 10 (gold contacts)
(5)
Refer to page 6. • (6) For a dry and clean environment.
Insulation
Rated power-frequency withstand voltage (50 Hz, 1 mn) U50 [kVrms] 1.5
OPERATING CONDITIONS
Installation Indoor or outdoor
Altitude [m] < 1400
Working ambient temperature Tamb [°C] -40 to +70 / -50 to +70
Humidity Class 5K2
Pollution degree PD4
Minimum mechanical durability N [Cycles] 250’000
Uimp [kV]
125 170
HV
241
15 kV 25kV 25 kV
15
Frame level Frame level
142
320
420 420
64 32 880
101
114
420 420
>430
430
385
330
388
385
Roof opening and frame dimensions
150
105
65 110
22.5
MOUNTING POSSIBILITIES
/// VERTICAL MOUNTING ON THE ROOF /// HORIZONTAL MOUNTING ON THE ROOF
The bellow scheme represents MACS standard configuration (4a+4b – switch PF), with optional additional auxiliary switches
(4a+4b – switch PF) and optional manual earthing switch (2a+2b – switch PF).
For electric earthing switch, please contact Sécheron.
O+ Control A B C D E F G H
c7
Unit
c8 O-
c3 R
a8 a2 a4 a13 a10 a15 a6 a17 b2 b8 b13 b4 b15 b10 b17 b6
c9 Ra
Rb c4 c5 c6 c15
c14
ES
I J
B : Battery power supply
O : Control order
R : Ready switch (MACS ready to close)
ES : Earthing switch c16 c10 c11 c17
: Optional auxiliary contacts
a b c
Weight:
AC circuit-breaker + 13 kg (manual version)
Electric version (option) Manual version (standard) AC circuit-breaker + 20 kg (electric version)
HV
540 (170 kV)
521 (125 kV)
HV
142
167
142 320
50* 150*
220*
844
380*
Overhead line 15 or 25 kVac For a safe and efficient protection of the vehicle’s high
voltage circuits against ligthning and switching overvoltages,
AC
VCB Sécheron strongly recommends to use two surge arresters
SA1 and SA2 in the high voltage circuit of the vehicle.
424
6 AC CIRCUIT-BREAKER FOR ROLLING STOCK, TYPE MACS
LV MOBILE CONNECTOR FOR AC CIRCUIT-BREAKER
(SEPARATELY ORDERED ITEM)
SG325249R00521
Case 7
Harting Harting
ES 2a + 2b PF 2 12 M25
HAN® 24 DD HAN® 24 DD
SG325249R00520
(1)
AC VCB: AC Vacuum Circuit-Breaker
ES: Earthing Switch.
(2)
PF: Potential Free.
Notes:
• Harting Han® Modular 51 pins connector is made of 3 Harting HAN® DDD17 modules (each module supplied with 17 pins).
• The above references are given for mobile connectors considering that all the auxiliary contacts are wired, with an external wire
diameter of 2.8 mm for a copper section of 2.5mm² and 2.3 mm for a copper section of 1.5 mm². If the conditions are different from
these, the above references may change. In such case please inform Sécheron accordingly.
DESIGNATION CODE
Customer’s
Line Description Designation Standard Options
choice
10
Product type MACS M M
Signature:
11 Nominal voltage 15 kV or 25 kV (Uimp = 125 kV) 4
25 kV (Uimp = 170 kV) 3
12 Mechanical interface Standard base plate / vertical mounting A A
13 Earthing switch No 0
Yes (with manual operation) 1
Yes (with electric operation) 2
14 Surge arrester No 0
Yes - For surge arrester type and code, please contact Sécheron ...
15 Control voltage 24 Vdc A
32 Vdc F
36 Vdc B
48 Vdc / 50 Vdc C
72 Vdc D
110 Vdc E
16 Auxiliary contacts on the AC circuit-breaker
4a + 4b - (switch PF) - silver type A
4a + 4b - (switch PF) - gold type C
8a + 8b - (switch PF) - silver type B
8a + 8b - (switch PF) - gold type D
17 Auxiliary contacts on the earthing switch (No earthing switch) Not applicable Z
None (1) 0
2a + 2b - (switch PF) - silver type H
Name:
2a + 2b - (switch PF) - gold type C
18 Interlocking keys for earthing switch
(Electric operation or no earthing switch) Not applicable Z
No key / lock 0
1 blue (master) + 1 yellow (slave) B
1 blue (master) + 2 yellow (slave) C
2 blue (master) + 1 yellow (slave) F
1 yellow (master) + 1 green (slave) H
1 yellow (master) + 2 green (slave) I
2 yellow (master) + 1 green (slave) L
Key / locks delivered by customer S
19 Key and lock codification for each unit
(Electric operation or no earthing switch) Not applicable Z
No 0
Yes 1
20 Ambient temperature range -40 °C to +70 °C 1
-50 °C to +70 °C 2
(1)
For manual switch only.
The low voltage connector must be ordered separately (refer to page 7).
- LV mobile connector for the AC circuit-breaker with or without manual earthing switch:
- Additional LV mobile connector for the electric earthing switch: SG325249R00521 SG325249R005207