Excavator Sumitomo Failure Code
Excavator Sumitomo Failure Code
Excavator Sumitomo Failure Code
code/error
Short circuit
BZ cranes open after 7210 ○ no output from the ignition switch is turned ≠ Output Monitor
Output = Output Monitor
Short circuit
REL rotating lights and lock open 7211 ○ bucket from the ignition switch is turned on no output ≠
Output Monitor Output = Output Monitor
Short circuit
Lock rod from the solenoid valve open 7212 ○ no output after the ignition is turned ≠ Output
Monitor Output = Output Monitor
Short circuit
Pump output proportional valve open without current ≦ 30 mA 30 mA after 7240 ○ engine start
Short-circuit current from the ignition switch is turned ≧ 3 A
Pump flow proportional valve open without current ≦ 30 mA 30 mA after 7241 ○ engine start
Short-circuit current from the ignition switch is turned ≧ 3 A
After the fan proportional valve open 7242 ○ engine start no current ≦ 30 mA 30 mA Short-
circuit current from the ignition switch is turned ≧ 3 A
After the big boom proportional valve open 7243 ○ engine start no current ≦ 30 mA 30 mA
Short-circuit current from the ignition switch is turned ≧ 3 A
After the arm proportional valve open 7244 ○ engine start no current ≦ 30 mA 30 mA Short-
circuit current from the ignition switch is turned ≧ 3 A
Deviation proportional valve open after the engine starts 7245 ○ no current ≦ 30 mA 30 mA
Short-circuit current from the ignition switch is turned ≧ 3 A
Show “×” the project is not “abnormal electrical system” message. In addition, users no longer
DTC screen display. However, DTC recorded in the maintenance screen (DIAG) in.
(3) mechanical failure [7400-7599]
Fault location fault codes determine the timing of the failure mode occurred prerequisite
judgment recovery judgment
The conditions DTC display
Abnormally high temperature 1 7400 ○ one minute after starting the engine coolant temperature
sensor = normal CAN communication = normal ECM5 V supply voltage = normal temperature ≧
105 ℃ temperature <105 ℃
Unusually high temperatures 2 7402 ○ temperature ≧ 110 ℃ temperature <105 ℃
Abnormal high temperature 3 7403 ○ temperature ≧ 120 ℃ temperature <120 ℃
7404 ○ abnormal high temperature oil 1 minute after starting the engine oil temperature sensor
= normal oil temperature ≧ 95 ℃ temperature <95 ℃
Abnormally high temperature pressurized backward 1 7405 ○ supercharged engine start one
minute after the last-air temperature sensor = normal CAN communication = normal ECM5 V
supply voltage = normal pressurized air temperature ≧ 80 ℃ backward backward pressurized
air temperature ≦ 70 ℃
Unusually high temperatures 2 7406 ○ booster backward temperature ≧ 90 ℃ temperature
pressurized backward <90 ℃
No abnormal voltage, low voltage AC motor 7420 ○ 10 seconds after starting the engine
pressure ≦ 10 V power generating pressure> 10 V
Coolant level is too low 7421 ○ no level switch is open level switch off the ignition switch is
turned from
Low engine oil pressure after 7422 ○ abnormal engine start 30 seconds oil pressure sensor =
normal CAN communication = normal ECM5 V supply voltage = normal pressure ≦ 40 kPa
pressure> 10 40 kPa
Air filter clogged 7423 ○ 10 seconds after starting the engine without vacuum switch on the
vacuum switch off
Back to the oil filter clogged 7424 ○ 10 seconds after starting the engine oil filter pressure switch
back to normal pressure swissure switch open circuit.