27 Bolt Group Pullout
27 Bolt Group Pullout
27 Bolt Group Pullout
plate
washer
or flat
Force per Turn-of-the-Nut bar
d 21.0 in
threads 5 threads/inch Figure 27-1 Converting lateral force to tension force.
Dia 1.75 in
turn 0.125 turn of nut 45degrees
row 30
stretch 0.025000 inch 0.125 turn /5 threads/inch
strain 1.001190 inches/inch
(d + stretch) / d
( 21.0" + 0.025000" ) / 21.0"
row 60
Page 27 - 2
BOLT GROUP PULLOUT
EXHAUST STACK
27 Christy
20:38
05/26/18
Vortex moment and shear govern
row 70
Page 27 - 3
BOLT GROUP PULLOUT
EXHAUST STACK
27 Christy
20:38
05/26/18
Vortex moment and shear govern
logic 1 2 3 4 5 6 7 8 9 0
Diameter Fy Fu Ft 0.625 0.75 0.875 1 1.125 1.25 1.375 1.5 1.75 2
n = Threads/inch Ft = Fu/3 11 10 9 8 7 7 6 6 5 4.5
A Tensile Stress 0.226 0.334 0.462 0.606 0.763 0.969 1.155 1.405 1.899 2.498
0.7854 *(D_Gross - 0.9743/n)2
Area_b p * r2 0.307 0.442 0.601 0.785 0.994 1.227 1.485 1.767 2.405 3.142
A36 36 58 19.1 5.86 8.44 11.49 15.00 18.99 23.44 28.36 33.75 45.94 60.00
A307 20 6.14 8.84 12.03 15.71 19.88 24.54 29.70 35.34 48.11 62.83
A325 Grade 5 44 13.50 19.44 26.46 34.56 43.74 54.00 65.34 77.75 105.8 138.23
B7 Grade 5 44 13.50 19.44 26.46 34.56 43.74 54.00 65.34 77.75 105.8 138.23
A490 Grade 8 A354 GR BD 54 16.57 23.86 32.47 42.41 53.68 66.27 80.18 95.43 129.9 169.65
logic 1
row 110
Refer to the Bolt Threads chapter in this manual for bolt values.
These values are taken from AISC Table 1-A BOLTS, THREADED PARTS AND RIVETS and Table 1-B THREADED FASTENERS
where values for Ft are multiplied by the gross area to get allowable loads. See Gaylord and Gaylord 2nd edition page 6-79 for an
example.
row 120
Tensile strength may also be obtained from AISC Table 1-C MATERIAL FOR ANCHOR BOLTS AND TIE RODS. Allowable loads are
generated by multiplying the tensile strength by the Tensile Stress Area given in Table ANSI B1.1-1982 on page 4-147 of 9th
edition of the AISC ASD manual. The Tensile Stress Area accounts for available area reduced by the presence of bolt threads.
Page 27 - 4
BOLT GROUP PULLOUT
EXHAUST STACK
27 Christy
20:38
05/26/18
Vortex moment and shear govern
row 130
Page 27 - 5
BOLT GROUP PULLOUT
EXHAUST STACK
27 Christy
20:38
05/26/18
Vortex moment and shear govern
Punching Shear
d 21.0 in embed depth to top of anchor plate
PL_dia 3.0 in plate diameter
bo 75.4 in at d/2 from edge if anchor plate [ (d /2) * 2 + PL_diameter] * p
(21.0 + 3.0) * PI row 150
VC 347 k ult 4 f'C * bo * d UBC (11-37) where bo * d = Ao d/2
4 * ( 3 * 1000 )^0.5 * 75.4 * 21.0 /1000
Ф 0.85 unitless strength reduction factor
Vu 294.9 k_ult
P allowed 60.0 k ult minimum of 294.9, 80.0, 60.0, 222.2 Ao area
P allowed 42.9 k working 60 k_ult / 1.4 UBC (12 - 11) basic load combinations of cylinder
in shear
λ 1 unit UBC 1911.7.4.3
Tu_sum 37.6 k_ult factor * (t_tens + V_shear /(µ * λ) ) UBC 1911.7.4.3
1.0 * (35.60 + 1.38 / (0.70 * 1.00) ) Figure 27-4 Punching shear cylinder.
T_sum 37.6 k Tu_sum / (factor = 1.00) for working strength
42.9 > 37.6 required OK
SHEAR FRICTION CONNECTION -- Bearing Against Anchor Plate Area of bearing must be at least
Diameter 1.75 in 1.5 x anchor shank area 1923.3.4 supporting
A shank 2.41 in2 surface
factor 1.0 seismic factor UBC1612.2.1 (12-5) / UBC 1909.2.3
µ 0.7 unit UBC 1911.7.4.3
λ 1 unit UBC 1911.7.4.3
A_1 18.10 in2 gross area of plate (square or round)
A_1 net 16 in2 A_1 net - A shank
OK Area
A_2 600 in2 area of supporting surface which is wider on all sides than the bearing area
row 190
Page 27 - 7
BOLT GROUP PULLOUT
EXHAUST STACK
27 Christy
20:38
05/26/18
Vortex moment and shear govern
fut 58 k/in2 bolt ultimate tensile strength Figure 27-6 View of the shear cone.
Pss 23.1 k_ult 0.9 * Ab * fut INSPECTION -- UBC 1923.2 row 210
0.9 * 0.44 in² * 58 ksi 1.3 Special inspection provided for bolts
anchored in compression zone
Vss 19.2 k_ult 0.75 * Ab * fut 2 No special inspection
0.75 * 0.44 in² * 58 ksi 2 Special inspection provided for bolts anchored
in tension zone
λ 1.00 unitless concrete factor 3 No special inspection for bolts anchored in
the tension zone
dh 1.25 in Tributary area of plate 1.2 in² or head
Actual plate may be rectangular
λ UBC 1923.3.2 row 220
dm 5.0 in depth of embedded plate for pullout 1.00 normal weight concrete
f'c 3 k/in2 compressive strength of concrete 0.85 sand light weight concrete
0.75 all-light weight concrete
AP 99 in2 effective area of projected cone
onto the surface of the slab
((1.3 + 2 * 5.0) /2)² * π
Edge distance
Pc 5.4 k_ult λ * AP * f'C UBC 1923.3.2 Shear loading more than 10 diameters from the
1.00 * 99 in² * 3,000 /1000 loaded edge.
row 230
Vc 19.4 k_ult 800 * Ab * f'C UBC 1923.3.3 Tension or shear away from an edge more
800 * 0.44 * 3 * 1000 /1000 than 5 diameters away and with reinforcing
for bolts more than 10 diameters towards to prevent concrete in tension failure.
the loaded edge Vc not governed by Ab
Edge distance not less than 4 diameters in
Vc 34.4 k_ult 2 π de2 λ f'C any case.
2 * π * 10.0² * 1.00 * 3 * 1000 /1000
Vc 34.4 k_ult
PU 2
+ VU 2
= 0.0 2
+ 14.8 2
= 0.595 < 1 OK
Page 27 - 8
BOLT GROUP PULLOUT
EXHAUST STACK
27 Christy
20:38
05/26/18
Vortex moment and shear govern
Pss 115.3 k_ult 0.9 * Ab * fut * number Figure 27-7 View of shear cones in a row.
0.9 * 0.44 in² * 58 ksi * 5
row 270
Vss 96.1 k_ult 0.75 * Ab * fut * number
0.75 * 0.44 in² * 58 ksi * 5
1 PU 5/3
+ VU 5/3
= 1 0.0 5/3
+ 14.8 5/3
= 0.020 < 1.000 OK
Ф Pc Vc 0.85 16.8 172.1
PU 2
VU 2
= 0.0 2
+ 14.8 2
= 0.024 < 1.000 OK
PSS VSS 115.3 96.1
row 290
HILTI Fy Fu
HAS Std / A36 36 58 row 300
HAS Super /B7 105 125
HAS SS /A 304 SS 65 100
A307 60
A108 studs 60
A325 to 1" Grade 5, B7 92 120
A325-1 1 1/8" to 1 1/2" 81 105
A490 Gr 8, 1/2" - 1 1/2" 120 150
Page 27 - 10
BOLT GROUP PULLOUT
EXHAUST STACK
27 Christy
20:38
05/26/18
Vortex moment and shear govern
Pss 92.2 k_ult 0.9 * Ab * fut * number_ Figure 27-8 View of grouped shear cones.
0.9 * 0.44 in² * 58 ksi * 4
1 PU 5/3
+ VU 5/3
= 1 0.0 ^5/3
+ 14.8 ^5/3
= 0.029 < 1.000 OK
Ф Pc Vc 0.85 12.7 137.7
PU 2
VU 2
= 0.0 2
+ 14.8 2
= 0.037 < 1.000 OK
PSS VSS 92.2 76.9
row 350
row 360
Page 27 - 12
BOLT GROUP PULLOUT
EXHAUST STACK
27 Christy
20:38
05/26/18
Vortex moment and shear govern
For an anchor group where the distance between anchors is less than twice their embedment lengths, row 390
the failure surface is assumed to be that of a truncated pyramid
radiating at a 45 degree slope from the bearing edge of the anchor group
toward the surface from which the anchors protrude.
The effective area is the projection of this truncated pyramid on this surface.
row 410
row 420
Page 27 - 14
BOLT GROUP PULLOUT
EXHAUST STACK
27 Christy
20:38
05/26/18
Vortex moment and shear govern
row 430