Electronic Timer CT-MFD.12: Multifunctional With C/o Contact Data Sheet
Electronic Timer CT-MFD.12: Multifunctional With C/o Contact Data Sheet
Electronic Timer CT-MFD.12: Multifunctional With C/o Contact Data Sheet
12
Multifunctional with 1 c/o contact
Data sheet
Features
2CDC 251 089 F0t06
Approvals
A UL 508, CAN/CSA C22.2 No.14
a Rotary switch for the
preselection of the time D GOST
range K CB scheme
E CCC
b Potentiometer with direct
reading scale for the fine Marks
adjustment of the time
a CE
delay
b C‑Tick
c Rotary switch for the
preselection of the timing Order data
function
Type Rated con- Time range Output Control in- Order code
trol supply put
d U: green LED ‑ voltage
V
control supply voltage
applied CT-MFD.12 24‑48 V DC, 0.05 s ‑ 100 1 c/o voltage‑ 1SVR 500 020 R0000
W 24‑240 V AC h contact related
timing triggering
Operating mode
The CT‑MFD.12 has 1 c/o contact and provides 7 timing functions. The function is rotary switch selecta‑
ble on the front of the unit. Each function is indicated by an international function symbol.
One of 7 time delay ranges, from 0.05 s to 100 h, can be selected with another rotary switch. The fine
adjustment of the time delay is made via an internal potentiometer, with a direct reading scale, on the
front of the unit.
ABB
Electronic timer CT-MFD.12
Multifunctional with 1 c/o contact
Data sheet
Function diagram(s)
A ON‑delay
This function requires continuous control supply voltage for timing.
Timing begins when control supply voltage is applied. The green LED flashes during timing. When the
selected time delay is complete, the output relay energizes and the flashing green LED turns steady.
If control supply voltage is interrupted, the output relay de‑energizes and the time delay is reset.
Control input A1‑Y1/B1 is disabled when this function is selected.
A1-A2
A1-A2
A1-A2
2CDC 252 038 F0207
A1-Y1/B1
15-18
15-16
green LED
t <t
ABB
Electronic timer CT-MFD.12
Multifunctional with 1 c/o contact
Data sheet
Function diagram(s)
CA Impulse‑ON
This function requires continuous control supply voltage for timing.
The output relay energizes immediately when control supply voltage is applied and de‑energizes after the
set pulse time is complete. The green LED flashes during timing. When the selected pulse time is com‑
plete, the flashing green LED turns steady.
If control supply voltage is interrupted, the output relay de‑energizes and the time delay is reset.
Control input A1‑Y1/B1 is disabled when this function is selected.
A1-A2
A1-A2
A1-A2
H Pulse former
This function requires continuous control supply voltage for timing.
Closing control input A1‑Y1/B1 energizes the output relay immediately and starts timing. Operating the
control contact switch A1‑Y1/B1 during the time delay has no effect. The green LED flashes during tim‑
ing. When the selected ON time is complete, the output relay de‑energizes and the flashing green LED
turns steady. After the ON time is complete, it can be restarted by closing control input A1‑Y1/B1.
If control supply voltage is interrupted, the output relay de‑energizes and the time delay is reset.
A1-A2
2CDC 252 039 F0207
A1-Y1/B1
15-18
15-16
green LED
t t
ABB
Electronic timer CT-MFD.12
Multifunctional with 1 c/o contact
Data sheet
Connection diagram(s)
Wiring instructions
Parallel load to control input possible / allowed
L(+)
A2
N(-)
ABB
Electronic timer CT-MFD.12
Multifunctional with 1 c/o contact
Data sheet
Technical data
Data at Ta = 25 °C and rated values, if nothing else indicated
Input circuits - Supply circuit 1SVR 500 020 R0000
Rated control supply voltage US A1‑A2 24‑240 V AC
A1‑A2 24‑48 V DC
Polarized yes
Impulse‑ON
Pulse former
ABB
Electronic timer CT-MFD.12
Multifunctional with 1 c/o contact
Data sheet
DC12 (resistive) at 24 V 6A
DC13 (inductive) at 24 V 2A
ABB
Electronic timer CT-MFD.12
Multifunctional with 1 c/o contact
Data sheet
Rated impulse withstand voltage Uimp between all isolated circuits 4 kV; 1.2/50 µs
(type test) (IEC/EN 60664‑1, VDE 0110)
Power‑frequency withstand voltage test between all isolated circuits 2.5 kV, 50 Hz, 1 s
(Test voltage, routine test)
Basic insulation (IEC/EN 61140) Input circuit / Output circuit 300 V
Protective separation (IEC/EN 61140, VDE Input circuit / Output circuit 250 V
0106 part 101 and part 101/A1)
Pollution degree (IEC/EN 60664‑1, VDE 3
0110, UL 508)
Overvoltage category (IEC/EN 60664‑1, III
VDE 0110, UL 508)
ABB
Electronic timer CT-MFD.12
Multifunctional with 1 c/o contact
Data sheet
Technical diagrams
Load limit curve
Derating factor F
1.0
2CDC 252 124 F0206
Derating factor F
0.9
0.8
0.7
0.6
0.5
0.1 0.2 0.3 0.4 0.5 0.6 0.7 0.8 0.9 1.0
cos ϕ
Contact lifetime
2CDC 252 123 F0206
Switching cycles
250 V
resistive load
ABB
Electronic timer CT-MFD.12
Multifunctional with 1 c/o contact
Data sheet
Dimensions
in mm
58 2.28“
0.69“ 0.2“
17,5 5 43,4 1.71“
70 2.76“
45 1.77“
Synonyms
Used expression Alternative expression(s) Used expression Alternative expression(s)
1 c/o contact 1 SPDT voltage‑related wet / non‑floating
Further Documentation
Electronic Products and Relays Technical catalogue 2CDC 110 004 C020x
You can find the documentation in the internet under www.abb.com/lowvoltage R Control Products R ...
ABB
Document number: 2CDC 111 058 D0201 (12/2007)