Location via proxy:   [ UP ]  
[Report a bug]   [Manage cookies]                

Monitor Stryker 26 PLG

Download as pdf or txt
Download as pdf or txt
You are on page 1of 28

VISION ELECT HDTV

26” High-Definition
LCD Monitor
REF 240-030-960

User Guide
English

2008/11 www.stryker.com 1000-401-075 E

Downloaded from www.Manualslib.com manuals search engine


53 mm
mm (2.04”) mm
327 mm (12.91”) 48 mm
mm(1.89”)

121.2 mm (4.77”)
mm

mm
110.2 mm (4.34”)

3 mm (0.12”)
3mm 228.8 mm
mm (9.01”) 194 mm
mm (7.64”) 3 mm
mm (0.12”)

428.8 mmmm(16.88”)
100 mm (3.94”) 345.8 mmmm(13.61”)

Downloaded from www.Manualslib.com manuals search engine


100 mm100mm
(3.94”)
552.1mm
mm (21.74”)
616.4 mm (24.27”)
VISION ELECT HDTV English
26” High-Definition
LCD Monitor
Table of Contents
Warnings and Cautions ................................................................... EN-2
Warnings ...................................................................................... EN-2
Cautions ....................................................................................... EN-3

Symbol Definitions ........................................................................... EN-5

Product Description and Intended Use .......................................... EN-6


Product Contents ......................................................................... EN-6
System Interconnection ............................................................... EN-8
Power Connection........................................................................ EN-8

Operating the Monitor ...................................................................... EN-9


Front Panel Controls .................................................................... EN-9
Rear Panel Panel ....................................................................... EN-10
Input Port Layout........................................................................ EN-10
Fiber Optic Module (optional) Installation .................................. EN-11
Input Selection List..................................................................... EN-11
Standard On-Screen Display (OSD) Operation ......................... EN-12
Stryker Camera Preset Modes................................................... EN-12
OSD Function Description ......................................................... EN-13

Cleaning the Monitor...................................................................... EN-14


Cleaning display plastic area ..................................................... EN-14
Cleaning display filter area......................................................... EN-14

Troubleshooting ............................................................................. EN-15

Technical Specifications................................................................ EN-16


Classification and Approvals ...................................................... EN-17

Electromagnetic Compatibility...................................................... EN-18

Warranty .......................................................................................... EN-23

Service and Claims......................................................................... EN-23

Declaration of Conformity ............................................................. EN-24

EN-1
Downloaded from www.Manualslib.com manuals search engine
Warnings and Cautions
Please read this manual and follow its instructions carefully. The words
Warning, Caution, and Note carry special meanings and should be
carefully reviewed:
Warning The personal safety of the patient or physician may be
involved. Disregarding this information could result in
injury to the patient or physician.

Warning A lightning bolt within a triangle is intended to warn of


the presence of hazardous voltage. Refer all service to
authorized personnel.

Caution Special service procedures or precautions must be


followed to avoid damaging the instrument.

Note Special information to make maintenance easier or


important information more clear.

Warnings
Warning To avoid potential serious injury to the user and the
patient, and/or damage to this device, the user must:

1. Restrict this device to use by, or on the order of, a physician,


because of Federal law (United States of America).
2. Read the operating manual thoroughly and be familiar with its
contents prior to using this equipment.
3. Carefully unpack the unit and check if any damage occurred
during shipment.
4. Test this equipment prior to a surgical procedure. This monitor
was fully tested at the factory before shipment.
5. Do not place the monitor or any other heavy object on the power
cord. Damage to the cable can cause fire or electric shock.
6. Should any solid object or liquid fall into the panel, unplug the unit
and have it checked by qualified personnel before operating it
any further.
7. Unplug the unit if it is not to be used for an extended period of
time. To disconnect the cord, unscrew plug first, then pull it out by
the plug. Never pull the cord itself.
8. To avoid electric shock, avoid removing control unit covers.

EN-2
Downloaded from www.Manualslib.com manuals search engine
9. Do not attempt internal repairs or adjustments not specifically
detailed in this operating manual. English
10. Pay close attention to the care and cleaning instructions in this
manual. A deviation may cause damage (refer to the Cleaning
section).
11. Do not sterilize the monitor.
12. Use appropriate caution to prevent contact with fluids if the unit is
being used with a power supply in patient environments.

Cautions
1. The AC Adapter must be plugged in to a grounded power outlet.
2. Use only the proprietary VISION ELECT HDTV power supply
(P/N 240-030-950, Manufacturer: JEC Korea, Model No:
JMW1150KA2400F07) for the VISION ELECT HDTV monitor
(model 240-030-960). Completely secure the connection
between the DC power cord and the extension cord.
3. Grounding reliability can only be achieved when the equipment is
connected to an equipment receptacle labeled “Hospital Only” or
“Hospital Grade.”
4. To connect to an international power supply, use an attachment
plug appropriate for the power outlet.
5. Turn power off when the unit is not in use.
6. Remove the power module and connection when transporting the
unit.
7. Save the original carton and associated packing material. They
will be useful should you have to transport or ship the unit.
8. Handle the monitor with care. Do not strike or scratch the screen.
9. Never operate the unit right after having been transported from a
cold location directly to a warm location.
10. Do not expose the monitor to moisture or apply liquid cleaners
directly to the screen. Spray the cleaning solution into a soft cloth
and clean gently.
11. Allow adequate air circulation to prevent internal heat buildup.
12. Do not place the unit on surfaces (rugs, blankets, etc.) or near
materials (curtains, draperies) that may block the ventilation slots.
The monitor is cooled by natural convection and has no fan.
13. Do not install the unit near sunlight, excessive dust, mechanical
vibration, or shock.
14. The unit is designed for operation in a horizontal position. Do not
operate the unit in a vertical position.

EN-3
Downloaded from www.Manualslib.com manuals search engine
15. Keep the unit away from equipment that uses strong magnets
(i.e., large loudspeakers).
16. Do not touch the patient with signal input or output connectors.
Equipment with SIP/SOP connectors should either comply with
IEC 60601-1 and/or IEC 60601-1-1 harmonized national
standards or the combination should be evaluated.
17. CAUTION: Changes or modifications not expressly approved by
the party responsible for compliance could void the user’s
authority to operate the equipment.
Note This equipment has been tested and found to comply with
the limit for a Class B digital device, pursuant to Part 15
of the FCC Rules. These limits are designed to provide
reasonable protection against harmful interference in a
residential installation. This equipment generates, uses,
and can radiate radio frequency energy and, if not installed
and used in accordance with the instructions, may cause
harmful interference to radio communications. There is no
guarantee that interference will not occur in a particular
installation, which can be determined by turning the
equipment off and on. The user is encouraged to try to
correct the interference by one or more of the following
measures:
• Reorient or relocate the receiving device.
• Increase the separation distance between the
equipment.
• Connect the equipment to an outlet on a circuit
different from that to which the other device(s)
are connected.
• Consult the manufacturer or field service
technician for help.
18. To ensure electromagnetic compatibility, refer to the
“Electromagnetic Compatibility” section of this manual. The
VISION ELECT HDTV (model 240-030-960) monitor must be
installed and operated according to the EMC information
provided in this manual.
The VISION ELECT HDTV (model 240-030-960) monitor has been tested
under the UL 60601-1 standard and is UL listed for medical application.
The warranty is void if any of these warnings or cautions are
disregarded.

EN-4
Downloaded from www.Manualslib.com manuals search engine
Symbol Definitions English
The following symbols appear on the product, its labeling, or the product
packaging. Each symbol carries a special definition, as defined below:

Dangerous: High Voltage

Consult accompanying documents

Direct Current

Indicates protective earth ground

For indoor use only

DC power control switch

SN Serial Number

Top - Bottom

Fragile

Do not get wet

3 Maximum Stacking

Manufacturer

European Authorized Representative

Indicates proof of conformity to applicable European Economic Community


Council directives and to harmonized standards published in the official journal
of the European Communities

Medical Equipment is in accordance with UL 60601-1 and CAN/CSA C22.2 No.


51LJ 601.1 in regards to electric shock, fire hazards, and mechanical hazards
Medical Equipment
E215822

Tested to comply with FCC Class B standards

IPX1 Degrees of protection against the ingress of water

This symbol indicates that the waste of electrical and electronic equipment
must not be disposed as unsorted municipal waste and must be collected
separately. Please contact the manufacturer or other authorized disposal
company to decommission your equipment.

• DC power on at locker switch

EN-5
Downloaded from www.Manualslib.com manuals search engine
Product Description and Intended
Use
The VISION ELECT HDTV (model 240-030-960) High Definition LCD
Monitor is an intelligent, microprocessor-based TFT-LCD monitor
intended for use in endoscopic surgical applications. It has an
ergonomically designed display and is compatible with most analog
RGB (Red, Green, Blue) display standards.
The VISION ELECT HDTV (model 240-030-960) monitor has the
following features:
• Advanced Viewing Solution (AVS): A sophisticated filter
extends the viewing angle of the screen image, without
sacrificing contrast ratio and brightness.
• Upgraded video cards or software will not require buying a new
monitor because of the wide auto-scanning compatibility range.
• The internal microprocessor digitally controls auto-scanning, for
horizontal scan frequencies between 31.47 KHz and 78.88 KHz,
and vertical scan frequencies between 50.0 Hz and 85.1 Hz. In
each frequency mode, the microprocessor-based circuitry allows
the monitor to function at the precision of a fixed frequency.
• The resident memory allows for storing factory default settings
and also additional user adjustment parameters.
• The maximum resolution achievable is WUXGA (1920 × 1200,
60Hz).
• The monitor is compliant with the VESA-DPMS power-
management standard. In order to save energy, the monitor
must be connected to a system compliant with the standard.
• The monitor is designed to mount an accessory (such as a
camera or speaker) with a 2 lbs (max) load per hole.
• The monitor is certified by UL International in accordance with
medical standard UL 60601-1. It is also CE marked for sale in
the European Community for integration or use with medical
products.

Product Contents
1. Carefully unpack the VISION ELECT HDTV (model 240-030-960)
monitor. Save the original carton and associated packing
material. They will be useful should you have to transport or ship
the unit.
2. Check the monitor and its accessories for any damage that may
have occurred during shipping. Immediately report any damage
to the shipping company.

EN-6
Downloaded from www.Manualslib.com manuals search engine
3. Check the contents of the accessories package with the following
list to make sure all components have been included. In addition English
to this manual, you should find:
Included Accessories
(a) 1 AC adapter (Stryker P/N 240-030-950,
Manufacturer: JEC, Model No: JMW1150KA2400F07)
(b) 4 M4 × 10mm VESA screws
(c) 2 Cable-managerment clamps
Optional Accessories (not shown)
1. Fiber optic module (Stryker P/N 240-030-962)
2. 15-ft. (5 pin) DC extension cable (Stryker P/N 240-030-951)
3. 75-ft. (5 pin) DC extension cable (Stryker P/N 240-030-952)
4. 2-to-5 pin DC convertor adapter (Stryker P/N 240-030-953)
5. DVI cable
6. VGA HDDB15 cable
7. BNC cable
8. S-Video cable
9. Hospital-grade AC power cord

EN-7
Downloaded from www.Manualslib.com manuals search engine
System Interconnection
VISION ELECT HDTV
(Model 240-030-960)
VISIONELECT
Video Input Signals
(Model 240-030-930)
SD/HD-SDI
output

Video Input Signals


Additional Inputs:
RGBS
YPbPr
SD/HD-SDI
SOG

eg:
Signal Output
Signal Output: SDC
DVI
DVI VideoPeripheral
Peripheral eg:SDCSIDNE
RGBHV Video
RGBHV VIDEO
SIDNE PRINTER
S-Video
S-Video DVD/VCR
C-Video VIDEO PRINTER
C-Video
SDI
etc...
DVD/VCR
Fiber (Optional) etc....

Video
VideoSources:
Sources:Camera (xx88 Series)
Camera (1188 Series,
1088 Series, 988 Series)

Power Connection

Hospital-grade Power Supply 240-030-950 VISION ELECT HDTV


power cord Manufacturer: JEC Korea (Model 240-030-960)
Model No: JMW1150KA2400F07

Extension cord (Optional)


Manufacturer: JEC Korea
Stryker P/N: 240-030-951 (15ft) or 240-030-952 (75ft)

EN-8
Downloaded from www.Manualslib.com manuals search engine
Operating the Monitor English

Front Panel Controls


Operate the monitor using the rotary control located on the front panel.
A list of the monitor controls and their functions is provided below.

Power LED
Rotary
Power Switch Control
(Soft)
Figure 1: The VISION ELECT HDTV LCD Monitor front panel controls.

1. Power LED: Indicates menu current status. Displays green if


monitor is powered on; blinks red if monitor is in Standby mode.
2. Power Switch (Soft): Turns the power ON or OFF.
3. Rotary Control (Turn Right / Left): With the on-screen display
menu activated, increases/decreases the value of the selected
parameter. With the on-screen display deactivated, activates the
video source selection menu.
4. Rotary Control Switch (Push): Accesses/selects on-screen
display menu.
5. Rotary Control Switch (Push and Hold): Exits on-screen
display menu.

EN-9
Downloaded from www.Manualslib.com manuals search engine
Rear Panel Panel

VESA
mounting holes
(100mm)

Power
connector

Power Switch Connector


(Hard) tags

Cable
Managerment
Clamps

Figure 2: The VISION ELECT HDTV LCD Monitor rear panel.

1. VESA mounting holes (100mm): Use to mount the monitior.


2. Power connector: DC power connector.
3. Power switch (Hard): Turns the input DC power ON or OFF.
4. Connectors tag: Indicate types of connectors.
5. Cable-managerment clamps: Cables organizer.

Input Port Layout

Power Power Optical DVI VGA S-Video C-Video/ G/Y H-sync HD/SD HD/SD RS232
Switch 24V (optional) SOG R/Pr B/Pb V-sync SDI SDI
(hard) IN OUT

EN-10
Downloaded from www.Manualslib.com manuals search engine
Fiber Optic Module (optional) Installation
English

Unscrew those 2 screws

1. Power OFF the monitor using the hard power switch.


2. Unscrew the two screws from the cover plate, then remove the
cover plate.
3. Insert the Fiber Optic Module (Stryker P/N 240-030-962) into the
Fiber Optic Module slot.
Caution Excessive force or misalignment during insertion
might damage the module connector.

4. Power ON the monitor using the hard power switch.

Input Selection List


Digital RGB
Analog RGB
HD/SD-SDI
Component (Y/Pb/Pr)
RGBS
S-Video
C-Video
SOG
Exit

EN-11
Downloaded from www.Manualslib.com manuals search engine
Standard On-Screen Display (OSD) Operation
The monitor provides an on-screen display to help navigate through the
various monitor-adjustment menus.
1. Press the Rotary Control to activate the on-screen display (OSD)
menu.
2. Rotate the Rotary Control to move up or down through the menu.
The parameter will be highlighted when selected.
3. Press the Rotary Control to enter the next level OSD.
4. Rotate the Rotary Control to increase or decrease the value of
the selected parameter, or to make a selection on different
options.
5. To exit the OSD menu screen from the second- or third-level OSD
menu, select the Exit option. To completely exit the OSD, press
and hold the Rotary Control. If no keys are pressed for a time
period, the OSD automatically times out.
6. While the OSD menu is deactivated, rotate the Rotary Control to
activate the input signal selection menu. The current input signal
will be highlighted with a dot. Rotate the Rotary Control to select
the preferred input signal.

Stryker Camera Preset Modes

Camera Resolution Horizontal Vertical


(H x V) Frequency Frequency
(KHz) (Hz)

988 1024 x 768 49.09 59.90

988i 1024 x 768 41.25 50.00

1088/SDC Pro2 1024 x 768 50.03 60.00

1088i/SDC Pro2 1024 x 768 41.10 50.00

1088/1188/SDC HD 1280 x 1024 64.02 60.10

1088i/1188i/SDC HD 1280 x 1024 59.99 50.00

1188w720 1280 x 720 45.00 60.00

1188iw720 1280 x 720 37.50 50.00

EN-12
Downloaded from www.Manualslib.com manuals search engine
OSD Function Description
English
Item Function Description Range
Specialty
Chooses between color temperatures for Standard, Arth, Lap, PACS, or
Color Temperature *
Norm
Red Red balance -128 to 128
Green Green balance -128 to 128
Blue Blue balance -128 to 128
0.1 to 2.5, S0,
Gamma Gamma value
S1, S2
Setting
Brightness Increases or decreases the brightness 0-100
Contrast Increases or decreases the contrast 0-100
Phase** Increases or decreases the Phase level 0-100
Chroma** Increases or decreases the Chroma level 0-100
Image Sharpness Sets image sharpness 1-10
Video Sharpness** Increases or decreases the video sharpness 0-100
Image Effect
Chooses scale mode between Fill All, V-Fill, H-Fill, One To One or Fill To
Scale Mode
Aspect
Freeze Frame Enables or Disables freeze frame
Zoom/Pan Enables zoom-in and pan function
PIP Enables PIP (Picture In Picture) function
POP Enables POP (Picture On Picture) function
PBP Enables PBP (Picture By Picture) function
Advanced
OSD Control Controls OSD Menu Position, Background, and Timeout
Screen Control*** Controls and adjust Horizontal, Vertical, Frequency, Phase
ON, OFF, 30min,
Chooses DPMS (Display Power Management
DPMS 60min, 90min,
Signaling)
120min
Auto Source Select Adjusts Auto Source Select between on and off
Restore Factory
Sets to factory default
Settings
Key lock Sets to Key lock mode
Information
User Name Entry Enters custom username display for boot-up display
Serial Number Displays monitor serial number
Runtime Displays current run time of monitor
Input Format Displays current input format
Actual on-screen display values may vary with updated versions of the firmware and user setting.
* Color Temperature RGB adjustment is avilable only for Standard, Arth and Lap settings.
* PACS and Norm selection only available under SOG input.
** Only available under SDI, S, or C video input.
*** Only available under VGA input.

EN-13
Downloaded from www.Manualslib.com manuals search engine
Cleaning the Monitor
Caution Do not expose the monitor to moisture or apply liquid
cleaners directly to the screen. Spray the cleaning
solution into a soft cloth and clean the screen gently.

Cleaning display plastic area


No specific liquid or chemical is necessary for cleaning the VISION
ELECT HDTV (model 240-030-960) LCD monitor. Use only non-abrasive
cloths and cleaning solutions to clean similar equipment used in hospitals.
1. Clean with a dry soft cloth, or a soft cloth lightly moistened with
mild detergent solution. Do not use any type of solvent, such as
alcohol or benzine, which might damage the finish.
2. Apply alcohol to glass surfaces with soft cotton applicator to aid in
cleaning and drying without leaving spots or streaks.
3. Dry thoroughly with soft towel or gauze surgical sponge.
Acceptable cleaning agents for bezel cleaning include:
• Cidex (2.4% glutaraldehyde solution)
• 0.5% Chlorhexidine in 70% isopropyl alcohol

Cleaning display filter area


Clean with a dry soft cloth, or soft cloth lightly moistened with warm water.
Other acceptable cleaning agents are listed below:
• 70% isopropyl alcohol
• Cidex (2.4% glutaraldehyde solution)
• 0.5% Chlorhexidine in 70% isopropyl alcohol

EN-14
Downloaded from www.Manualslib.com manuals search engine
Troubleshooting English
Before returning your LCD monitor for service, consult the
troubleshooting list below:

Problem Current Status Remedy


Using the OSD, adjust the brightness and contrast
LED ON to maximum, or reset them to their default
settings.
Check the power switch at the front and back of
the monitor.
LED OFF
No Picture Check if the AC power cord is properly connected
to the AC adapter.
Check if the video signal cable is properly
connected at the back of the monitor.
LED Blinking
Check if power of the video signal source system
is ON.
Using the Screen Menu, adjust the PHASE,
Oversized, FREQUENCY, HORIZONTAL, and VERTICAL
Abnormal undersized display, settings with non-standard video signal timing.
Picture missing display, or
center shift Wait a few seconds after initial sync of video
signals, or power cycle the monitor.

EN-15
Downloaded from www.Manualslib.com manuals search engine
Technical Specifications
Display
LCD Monitor Panel 25.54 inches
(a-Si TFT Active matrix LCD)
Synchronization 2.5 - 5.0 Vpp separated sync
Pixel Pitch 0.2865(W) × 0.2865(H)
Response Time <25ms Typ
View Angle +/-89° (L/R) × +/-89° (U/D)
Display Colors 16 million colors
Native Resolution 1920 dots × 1200 dots
Input Signal 1 × DVI
1 × VGA
1 × HD/SD-SDI
1 × C-Video/SOG
1 × S-Video
1 × Component (Y/G, Pb/B, Pr/
R, H/CS, VS)
1 × Optical (optional)
Maximum Pixel Clock 170MHz

Electrical
Power Adapter AC 100-240V; DC 24V
Power Consumption 150W (max)
Current Direct

Dimensions
Dimensions (W × H × D) 616.4 × 428.8 × 121.2mm
(24.27 × 16.88 × 4.77 inches)
Weight 19.62 lbs
VESA Mounting Interface VESA 100 × 100mm

Operating Conditions
Operating Temperature 50 to 104ºF (10 to 40°C)
Relative Humidity 30 to 75%
Atmospheric Pressure Range 500 to 1060 hPa
Electrical Input Rating 24V DC 6.25A

Transport & Storage Conditions


Storage -4 to 140°F (-20 to 60°C)
Relative Humidity Range 10 to 85%
Atmospheric Pressure Range 500 to 1060 hPa

EN-16
Downloaded from www.Manualslib.com manuals search engine
Classification and Approvals
English

51 LJ
Medical Equipment
E215822

Class I Equipment
Medical equipment with respect to electric shock, fire and mechanical
hazards only in accordance with UL 60601-1 and CAN/CSA C22.2
No. 601.1.
IPX1 Water Ingress Protection
Continuous operation
Warning This equipment is not suitable for use in the presence
of a FLAMMABLE ANESTHETIC MIXTURE WITH AIR, or
WITH OXYGEN OR NITROUS OXIDE.

This monitor is intended for use on Health Care Facilities model


240-030-960.
No user serviceable parts inside. Ask qualified personnel before
accessing internal components.
Caution For disposal of waste product, follow the requirement
of the local code.

This product is considered electronic equipment. It must not


be disposed of as unsorted municipal waste, and must be
collected separately. Please contact the manufacturer or
other authorized disposal company to decommission your
equipment.

EN-17
Downloaded from www.Manualslib.com manuals search engine
Electromagnetic Compatibility
Like other electrical medical equipment, the VISION ELECT HDTV
(model 240-030-960) monitor requires special precautions to ensure
electromagnetic compatibility with other electrical medical devices. To
ensure electromagnetic compatibility (EMC), the VISION ELECT HDTV
(model 240-030-960) monitor must be installed and operated according to
the EMC information provided in this manual.
Note The VISION ELECT HDTV (model 240-030-960) monitor
has been designed and tested to comply with IEC
60601-1-2:2003 requirements for EMC with other devices.
Caution The VISION ELECT HDTV (model 240-030-960) monitor
may be interfered with by other equipment, including
portable and mobile RF communication equipment,
even if such equipment meets the applicable
emissions requirements.

Warning Using cables or accessories other than those provided


with the VISION ELECT HDTV (model 240-030-960)
monitor, may result in increased electromagnetic
emissions or decreased immunity to such emissions.
Warning If the VISION ELECT HDTV (model 240-030-960)
monitor is used adjacent to or stacked with other
equipment, observe and verify normal operation of the
VISION ELECT HDTV (model 240-030-960) monitor in
the configuration in which it will be used prior to using
it in a surgical procedure. Consult the tables below for
guidance in placing the VISION ELECT HDTV (model
240-030-960) monitor.
Warning When this device is connected with other electrical
equipment, leakage currents may be additive. To
minimize total leakage current per patient, ensure that
all systems are installed according to the requirements
of IEC 60601-1-1.

EN-18
Downloaded from www.Manualslib.com manuals search engine
English
Manufacturer's declaration - electromagnetic emissions

VISION ELECT HDTV (model 240-030-960) monitor is intended for use in the electromagnetic
environment specified below. The customer or the user of VISION ELECT HDTV (model 240-030-
960) monitor should assure that it is used in such an environment.

Emissions test Compliance Electromagnetic Environment - guidance

The VISION ELECT HDTV (model 240-030-


RF emissions 960) monitor must emit electromagnetic energy
Group 1
CISPR11 in order to perform its intended function. Nearby
electronic equipment may be affected.

RF emissions
Class B
CISPR11
VISION ELECT HDTV (model 240-030-960)
monitor is suitable for use in all establishments,
Harmonic emissions
Class D including domestic establishments and those
IEC61000-3-2
directly connected to the public low-voltage
power supply network that supplies buildings
Voltage Fluctuations/ used for domestic purposes.
flicker emissions Complies
IEC61000-3-3

EN-19
Downloaded from www.Manualslib.com manuals search engine
Manufacturer's declaration - electromagnetic immunity

VISION ELECT HDTV (model 240-030-960) monitor is intended for use in the electromagnetic
environment specified below. The customer or the user of VISION ELECT HDTV (model 240-030-960)
monitor should assure that it is used in such an environment.

Electromagnetic
IEC 60601
Immunity Test Compliance Level environment -
Test Level
guidance

Floors should be
wood, concrete, or
ceramic tile. If floors
Electrostatic Discharge
6kV contact 6kV contact are covered with
(ESD)
8kV air 8kV air synthetic material,
IEC61000-4-2
the relative humidity
should be at least
30%.

2kV for power 2kV for power Mains power quality


Electrical fast transient/
supply lines supply lines should be that of a
burst
1kV for input/output 1kV for input/output typical commercial or
IEC61000-4-4
lines lines hospital environment.

Mains power quality


1kV differential 1kV differential
Surge should be that of a
mode mode
IEC61000-4-5 typical commercial or
2kV common mode 2kV common mode
hospital environment.

Power frequency
magnetic fields
Power frequency should be at levels
(50/60Hz) magnetic field 3.0 A/m 3.0 A/m characteristic of a
IEC 61000-4-8 typical location in a
typical commercial or
hospital environment.

Mains power quality


should be that of a
typical commercial or
hospital environment.
If the user of VISION
ELECT HDTV (model
<5% Ut (>95% dip <5% Ut (>95% dip
240-030-960) image
in Ut) for 0.5 cycle in Ut) for 0.5 cycle
Voltage dips, short intensifier requires
40% Ut (60% dip in 40% Ut (60% dip in
interruptions and voltage continued operation
Ut) for 5 cycles Ut) for 5 cycles
variations on power supply during power mains
70% Ut (30% dip in 70% Ut (30% dip in
input lines interruptions, it is
Ut) for 25 cycles Ut) for 25 cycles
IEC61000-4-11 recommended that
<5% Ut (>95% dip <5% Ut (>95% dip
VISION ELECT
in Ut) for 5 sec. in Ut) for 5 sec.
HDTV (model 240-
030-960) image
intensifier be
powered from an
uninterruptible power
supply or a battery.

NOTE: Ut is the A.C. mains voltage prior to application of the test level.

EN-20
Downloaded from www.Manualslib.com manuals search engine
Manufacturer's declaration - electromagnetic immunity
English
VISION ELECT HDTV (model 240-030-960) monitor is intended for use in the electromagnetic
environment specified below. The customer or the user of VISION ELECT HDTV (model 240-030-960)
monitor should ensure that it is used in such an environment.

IEC 60601 Compliance


Immunity Test Electromagnetic Environment: Guidance
Test Level Level

Portable and mobile RF communications


equipment should be used no closer to any
part of the VISION ELECT HDTV (model
240-030-960) monitor system, including
cables, than the recommended separation
distance calculated from the equation
applicable to the frequency of the
transmitter.
Recommended Separation Distance
Conducted RF 3 Vrms
3V d = 1.17 P
IEC 61000-4-6 150 kHz to 80 MHz

Radiated RF 3 V/m
3 V/m
IEC 61000-4-3 80MHz to 2.5 GHz

d = 1.17 P 80 MHz to 800 MHz


d = 2.33 P 800 MHz to 2.5 GHz

where P is the maximum output power


rating of the transmitter in watts (W)
according to the transmitter manufacturer
and d is the recommended separation
distance in meters (m).
Field strengths from fixed RF transmitters,
as determined by an electromagnetic site
survey (a), should be less than the
compliance level in each frequency
range (b).
Interference may occur in the vicinity of
equipment marked with the following
symbol:

NOTE 1: At 80 MHz and 800 MHz, the higher frequency range applies.
NOTE 2: These guidelines may not apply in all situations. Electromagnetic propagation is affected by
absorption and reflection from structures, objects, and people.
(a) Field strengths from fixed transmitters, such as base stations for radio (cellular/cordless) telephones
and land mobile radios, amateur radio, AM and FM radio broadcast, and TV broadcast, cannot be
predicted theoretically with accuracy. To assess the electromagnetic environment due to fixed RF
transmitters, an electromagnetic site survey should be considered. If the measured field strength in the
location in which the VISION ELECT HDTV (model 240-030-960) monitor system is used exceeds the
applicable RF compliance level above, the VISION ELECT HDTV (model 240-030-960) monitor system
should be observed to verify normal operation. If abnormal performance is observed, additional
measures may be necessary, such as reorienting or relocating the VISION ELECT HDTV (model 240-
030-960) monitor unit.
(b) Over the frequency range 150 kHz to 80 MHz, field strengths should be less than 3 V/m.

EN-21
Downloaded from www.Manualslib.com manuals search engine
Recommended Separation Distances Between Portable and Mobile RF Communications
Equipment and the VISION ELECT HDTV (model 240-030-960) monitor System

The VISION ELECT HDTV (model 240-030-960) monitor system is intended for use in an
electromagnetic environment in which radiated RF disturbances are controlled. The user of the
VISION ELECT HDTV (model 240-030-960) monitor system can help prevent electromagnetic
interference by maintaining a minimum distance between portable and mobile RF communications
equipment (transmitters) and the VISION ELECT HDTV (model 240-030-960) monitor system as
recommended below, according to the maximum output power of the communications equipment.

Separation distance (m) according to frequency of transmitter

Rated maximum output


power (W) of transmitter 150 kHz to 80 MHz 80 MHz to 800 MHz 800 MHz to 2.5 GHz
d = 1.17 P d = 1.17 P d = 2.33 P

0.01 0.12 0.12 0.23

0.1 0.37 0.37 0.74

1 1.17 1.17 2.33

10 3.70 3.70 7.37

100 11.70 11.70 23.30

For transmitters rated at a maximum output power not listed above, the recommended separation
distance (d) in meters (m) can be estimated using the equation applicable to the frequency of the
transmitter, where P is the maximum output power rating of the transmitter in watts (W) according to
the transmitter manufacturer.

NOTE 1: At 80 MHz and 800 MHz, the separation distance for the higher frequency range applies.

NOTE 2: These guidelines may not apply in all situations. Electromagnetic propagation is affected by
absorption and reflection from structures, objects, and people.

EN-22
Downloaded from www.Manualslib.com manuals search engine
Warranty English
This Stryker Endoscopy product is warranted to the original purchaser for
a period of 90 days from the date of purchase to be free from defects in
material and workmanship.
This warranty extends to all purchases and is limited to the repair or
replacement of the product without charge when returned in the original
shipping case to:

Stryker Endoscopy
5900 Optical Court
San Jose, CA 95138
USA
Stryker Endoscopy cannot accept responsibility for returns or
replacements which have not been authorized. This warranty does not
cover damages caused by misuse or by failure to follow the procedures
outlined in this manual or demonstrated by Stryker Endoscopy
representatives.
There are no other expressed warranties.

Service and Claims


Do not attempt to service this product yourself. If service is needed either
during or after the warranty period, contact Stryker Endoscopy at
1-800-624-4422, or phone your local Stryker Endoscopy sales
representative.

EN-23
Downloaded from www.Manualslib.com manuals search engine
Declaration of Conformity
Manufacturer:
Stryker Endoscopy
5900 Optical Court
San Jose, CA 95138
USA
1-800-624-4422
1-408-754-2000
Product Designation: VISION ELECT HDTV (model 240-030-960) 26”
High Definition LCD Monitor
The above product complies with the requirements of EC Directive
93/42/EEC. This declaration is based on compliance testing to:
EN 60601-1/08-90
EN 60601-1 A1/05-93
EN 60601-1 A2/06-95
This document is on file.
The CE mark will be affixed based on directive 93/42/EEC.

Stryker European Representative


Regulatory Manager, Stryker France
ZAC Satolas Green Pusignan
Ave. de Satolas Green
69881 MEYZIEU Cedex, France

® Stryker and Stryker Endoscopy are registered trademarks of Stryker Corporation.

EN-24
Downloaded from www.Manualslib.com manuals search engine
Downloaded from www.Manualslib.com manuals search engine
Stryker Endoscopy
5900 Optical Court
San Jose, CA 95138 USA
1-408-754-2000, 1-800-624-4422
www.stryker.com

2008/11 www.stryker.com 1000-401-075 E

Downloaded from www.Manualslib.com manuals search engine

You might also like