70g33gra BK350
70g33gra BK350
70g33gra BK350
DuPont™ Zytel®
nylon resin
Zytel® 70G33GRA is a 33% glass fiber reinforced, heat stabilized, lubricated polyamide 66 for injection molding. It
is well suited for low wear, low friction applications.
Value
Property Test Method Units
DAM 50%RH
Identification
Resin Identification ISO 1043 PA66-GF33C
Part Marking Code ISO 11469 >PA66-GF33C<
Mechanical
Stress at Break ISO 527 MPa (kpsi) 190 (27.5) 135 (19.6)
Strain at Break ISO 527 % 2.5 4
Tensile Modulus ISO 527 MPa (kpsi) 12500 (1810) 8500 (1230)
Notched Charpy Impact Strength ISO 179/1eA kJ/m2 12 16
Unnotched Charpy Impact Strength ISO 179/1eU kJ/m2 80 90
Thermal
Deflection Temperature ISO 75-1/-2 °C (°F)
0.45MPa 256 (493)
1.80MPa 248 (478)
Melting Temperature ISO 11357-1/-3 °C (°F)
10°C/min 256 (493)
Other
Density ISO 1183 kg/m3 (g/cm3) 1450 (1.45)
Molding Shrinkage ISO 294-4 %
Normal, 2.0mm 0.8
Parallel, 2.0mm 0.2
Contact DuPont for Material Safety Data Sheet, general guides and/or additional information about ventilation, handling, purging, drying, etc.
ISO Mechanical properties measured at 4.0mm, ISO Electrical properties measured at 2.0mm, and all ASTM properties measured at 3.2mm.
Test temperatures are 23°C unless otherwise stated.
The DuPont Oval Logo, DuPont™, The miracles of science™ and Zytel® are trademarks or registered trademarks of DuPont Company. Copyright© 2006.
060615/060615
The information provided in this data sheet corresponds to our knowledge on the subject at the date of its publication. This information may be subject to revision as new
knowledge and experience becomes available. The data provided fall within the normal range of product properties and relate only to the specific material designated;
these data may not be valid for such material used in combination with any other materials, additives or pigments or in any process, unless expressly indicated otherwise.
The data provided should not be used to establish specification limits or used alone as the basis of design; they are not intended to substitute for any testing you may need to
conduct to determine for yourself the suitability of a specific material for your particular purposes. Since DuPont cannot anticipate all variations in actual end-use
conditions DuPont makes no warranties and assumes no liability in connection with any use of this information. Nothing in this publication is to be considered as a
license to operate under or a recommendation to infringe any patent rights. DuPont advises you to seek independent counsel for a freedom to practice opinion on the intended
application or end-use of our products. Caution: Do not use this product in medical applications involving implantation in the human body.
For other medical applications see "DuPont Medical Caution Statement", H-50102.
plastics.dupont.com
1/2
Product Information
Value
Property Test Method Units
DAM 50%RH
Processing
Melt Temperature Range °C (°F) 285-305 (545-580)
Melt Temperature Optimum °C (°F) 295 (565)
Mold Temperature Range °C (°F) 70-120 (160-250)
Mold Temperature Optimum °C (°F) 100 (210)
Drying Time, Dehumidified Dryer h 2-4
Drying Temperature °C (°F) 80 (175)
Processing Moisture Content % <0.20
Contact DuPont for Material Safety Data Sheet, general guides and/or additional information about ventilation, handling, purging, drying, etc.
ISO Mechanical properties measured at 4.0mm, ISO Electrical properties measured at 2.0mm, and all ASTM properties measured at 3.2mm.
Test temperatures are 23°C unless otherwise stated.
The DuPont Oval Logo, DuPont™, The miracles of science™ and Zytel® are trademarks or registered trademarks of DuPont Company. Copyright© 2006.
060615/060615
The information provided in this data sheet corresponds to our knowledge on the subject at the date of its publication. This information may be subject to revision as new
knowledge and experience becomes available. The data provided fall within the normal range of product properties and relate only to the specific material designated;
these data may not be valid for such material used in combination with any other materials, additives or pigments or in any process, unless expressly indicated otherwise.
The data provided should not be used to establish specification limits or used alone as the basis of design; they are not intended to substitute for any testing you may need to
conduct to determine for yourself the suitability of a specific material for your particular purposes. Since DuPont cannot anticipate all variations in actual end-use
conditions DuPont makes no warranties and assumes no liability in connection with any use of this information. Nothing in this publication is to be considered as a
license to operate under or a recommendation to infringe any patent rights. DuPont advises you to seek independent counsel for a freedom to practice opinion on the intended
application or end-use of our products. Caution: Do not use this product in medical applications involving implantation in the human body.
For other medical applications see "DuPont Medical Caution Statement", H-50102.
plastics.dupont.com