Location via proxy:   [ UP ]  
[Report a bug]   [Manage cookies]                

Dupont Delrin

Download as pdf or txt
Download as pdf or txt
You are on page 1of 3

Product Information

DuPont™ Delrin®
acetal resin

Delrin 127UV NC010 ®

Delrin ® 127UV is a high viscosity acetal homopolymer with UV stabilizers developed for automotive interior
applications. It has improvements in UV aging characteristics and thermal stability over Delrin ® 107.
Property Test Method Units Value

Identification
Resin Identification ISO 1043 POM
Part Marking Code ISO 11469 >POM<
Mechanical
Yield Stress ISO 527 MPa (kpsi) 70 (10.1)
Yield Strain ISO 527 % 23
Strain at Break ISO 527 %
50mm/min 65
Nominal Strain at Break ISO 527 % 45
Tensile Modulus ISO 527 MPa (kpsi) 2900 (420)
Flexural Modulus ISO 178 MPa (kpsi) 2700 (390)
Notched Charpy Impact Strength ISO 179/1eA kJ/m2
-30°C (-22°F) 11
23°C (73°F) 15
Unnotched Charpy Impact Strength ISO 179/1eU kJ/m2
-30°C (-22°F) 350
23°C (73°F) 400
Contact DuPont for Material Safety Data Sheet, general guides and/or additional information about ventilation, handling, purging, drying, etc.
ISO Mechanical properties measured at 4.0mm, ISO Electrical properties measured at 2.0mm, and all ASTM properties measured at 3.2mm.
Test temperatures are 23°C unless otherwise stated.

The DuPont Oval Logo, DuPont™, The miracles of science™ and Delrin® are trademarks or registered trademarks of DuPont Company. Copyright© 2006.
060405/060406
The information provided in this data sheet corresponds to our knowledge on the subject at the date of its publication. This information may be subject to revision as new
knowledge and experience becomes available. The data provided fall within the normal range of product properties and relate only to the specific material designated;
these data may not be valid for such material used in combination with any other materials, additives or pigments or in any process, unless expressly indicated otherwise.
The data provided should not be used to establish specification limits or used alone as the basis of design; they are not intended to substitute for any testing you may need to
conduct to determine for yourself the suitability of a specific material for your particular purposes. Since DuPont cannot anticipate all variations in actual end-use
conditions DuPont makes no warranties and assumes no liability in connection with any use of this information. Nothing in this publication is to be considered as a
license to operate under or a recommendation to infringe any patent rights. DuPont advises you to seek independent counsel for a freedom to practice opinion on the intended
application or end-use of our products. Caution: Do not use this product in medical applications involving permanent implantation in the human body.
For other medical applications see "DuPont Medical Caution Statement", H-50102.

plastics.dupont.com
1/3
Product Information

Delrin 127UV NC010 ®

Property Test Method Units Value

Thermal
Deflection Temperature ISO 75-1/-2 °C (°F)
0.45MPa 160 (320)
1.80MPa 90 (195)
Melting Temperature ISO 11357-1/-3 °C (°F)
10°C/min 178 (352)
CLTE, Normal ISO 11359-1/-2 E-4/C (E-4/F)
-40 - 23°C (-40 - 73°F) 1.0 (0.55)
23 - 55°C (73 - 130°F) 1.1 (0.62)
55 - 100°C (130 - 212°F) 1.7 (0.93)
CLTE, Parallel ISO 11359-1/-2 E-4/C (E-4/F)
-40 - 23°C (-40 - 73°F) 1.0 (0.56)
23 - 55°C (73 - 130°F) 1.2 (0.67)
55 - 100°C (130 - 212°F) 1.6 (0.88)
Vicat Softening Temperature ISO 306 °C (°F)
50N 160 (320)
Rheological
Melt Mass-Flow Rate ISO 1133 g/10 min
190°C, 2.16kg 2.4
Electrical
Volume Resistivity IEC 60093 ohm m 1E11
Electric Strength IEC 60243-1 kV/mm 24
1.0mm 32 (812)
Relative Permittivity IEC 60250
1E2 Hz 3.5
1E6 Hz 3.4
Dissipation Factor IEC 60250 E-4
1E2 Hz 180
1E6 Hz 60
CTI IEC 60112 V 600
Contact DuPont for Material Safety Data Sheet, general guides and/or additional information about ventilation, handling, purging, drying, etc.
ISO Mechanical properties measured at 4.0mm, ISO Electrical properties measured at 2.0mm, and all ASTM properties measured at 3.2mm.
Test temperatures are 23°C unless otherwise stated.

The DuPont Oval Logo, DuPont™, The miracles of science™ and Delrin® are trademarks or registered trademarks of DuPont Company. Copyright© 2006.
060405/060406
The information provided in this data sheet corresponds to our knowledge on the subject at the date of its publication. This information may be subject to revision as new
knowledge and experience becomes available. The data provided fall within the normal range of product properties and relate only to the specific material designated;
these data may not be valid for such material used in combination with any other materials, additives or pigments or in any process, unless expressly indicated otherwise.
The data provided should not be used to establish specification limits or used alone as the basis of design; they are not intended to substitute for any testing you may need to
conduct to determine for yourself the suitability of a specific material for your particular purposes. Since DuPont cannot anticipate all variations in actual end-use
conditions DuPont makes no warranties and assumes no liability in connection with any use of this information. Nothing in this publication is to be considered as a
license to operate under or a recommendation to infringe any patent rights. DuPont advises you to seek independent counsel for a freedom to practice opinion on the intended
application or end-use of our products. Caution: Do not use this product in medical applications involving permanent implantation in the human body.
For other medical applications see "DuPont Medical Caution Statement", H-50102.

plastics.dupont.com

2/3
Product Information

Delrin 127UV NC010 ®

Property Test Method Units Value

Flammability
Flammability Classification IEC 60695-11-10
0.84mm HB
Oxygen Index ISO 4589-1/-2 % 20
Temperature Index
RTI, Electrical UL 746B °C
0.85mm 50
RTI, Impact UL 746B °C
0.85mm 50
RTI, Strength UL 746B °C
0.85mm 50
Other
Density ISO 1183 kg/m3 (g/cm3) 1420 (1.42)
Hardness, Rockwell ISO 2039/2
Scale M 92
Scale R 120
Water Absorption ISO 62, Similar to %
Equilibrium 50%RH 0.3
Immersion 24h 0.5
Saturation, immersed 1.2
Molding Shrinkage ISO 294-4 %
Normal, 2.0mm 1.9
Parallel, 2.0mm 2.1
Processing
Melt Temperature Range °C (°F) 210-220 (410-430)
Melt Temperature Optimum °C (°F) 215 (420)
Mold Temperature Range °C (°F) 80-100 (175-210)
Mold Temperature Optimum °C (°F) 90 (195)
Drying Time, Dehumidified Dryer h 2-4
Drying Temperature °C (°F) 80 (175)
Processing Moisture Content % <0.2
Hold Pressure Range MPa (kpsi) 90-110 (13-16)
Contact DuPont for Material Safety Data Sheet, general guides and/or additional information about ventilation, handling, purging, drying, etc.
ISO Mechanical properties measured at 4.0mm, ISO Electrical properties measured at 2.0mm, and all ASTM properties measured at 3.2mm.
Test temperatures are 23°C unless otherwise stated.

The DuPont Oval Logo, DuPont™, The miracles of science™ and Delrin® are trademarks or registered trademarks of DuPont Company. Copyright© 2006.
060405/060406
The information provided in this data sheet corresponds to our knowledge on the subject at the date of its publication. This information may be subject to revision as new
knowledge and experience becomes available. The data provided fall within the normal range of product properties and relate only to the specific material designated;
these data may not be valid for such material used in combination with any other materials, additives or pigments or in any process, unless expressly indicated otherwise.
The data provided should not be used to establish specification limits or used alone as the basis of design; they are not intended to substitute for any testing you may need to
conduct to determine for yourself the suitability of a specific material for your particular purposes. Since DuPont cannot anticipate all variations in actual end-use
conditions DuPont makes no warranties and assumes no liability in connection with any use of this information. Nothing in this publication is to be considered as a
license to operate under or a recommendation to infringe any patent rights. DuPont advises you to seek independent counsel for a freedom to practice opinion on the intended
application or end-use of our products. Caution: Do not use this product in medical applications involving permanent implantation in the human body.
For other medical applications see "DuPont Medical Caution Statement", H-50102.

plastics.dupont.com