GENERAL
37
1. GENERAL CONTROL UNIT CONNECTION B--81055EN/02
1.1
R--J2 Mate wide cabinet
SPECIFICATIONS OF
External diagram 495×470×320
CONTROLLER (W) (H) (D)
Peripheral device
Digital input 20 points
These signals include eight dedicated
signals:*HOLD RESET
signals:*HOLD,RESET,
START,ENBL,PNS1,PNS2,
PNS3, and PNS4
Digital output 16 polints
These signals include four dedicated
signals:
CMDENBL,FAULT,BATALM, and BUSY
Hand signals
Digital input 4 points
Digital output 4 points
Abnormal air pressure input 1 point
Hand breakage input 1 point
FANUC I/O link Use with selection of master mode and
slave mode software parameter stan-
dard : slave mode
External ON/OFF control An input terminal is provided on the
back of the door.
External emergency stop input An input terminal is provided on the
back of the door.
External emergency stop output An output terminal is provided on the
back of the door.
R--J2 Mate
38
B--81055EN/02 CONTROL UNIT CONNECTION 1.GENERAL
1.2
CONNECTION TO
CNC
Machine
tool CNC PMC
Controller
Fan
Peripheral
device
Power
supply Robot control printed Servo
unit circuit board amplifiter
Robot
Pulse coder
200VAC Circuit
protector MCC
Power
Emergency stop
PCB Emergency stop
Door unit RS--232--C
RS--422
NOTE
CNC is connected by I/O link cable or peripheral device
cable.
39
1. GENERAL CONTROL UNIT CONNECTION B--81055EN/02
1.3
PANEL MOUNT TYPE
Emergency
200VAC MCC
stop circuit
Robot
Power Servo amp.
Robot control for robot
supply AC
PCB reactor (PSM) (SVM)
unit Power
Pulse coder
Emergency stop
RS--232--C/RS--422
NOTE
When the ∼ series amplifier is used in a machine tool, the
power supply module can be shared. (Note, however, that
its capacity must be examined.)
D Required space (in mm) Robot control PCB : 125 ×380 ×250(including power supply unit)
Brake power unit : 110 ×100 ×150
Servo amplifier : 250 ×390 ×250 (including the PSM and SVM)
D Power capacity of Robot 1.2kVA
D Other notices 1. Brake power unit needs 100VAC.
2. Emergency stop and brake control circuit are required.
3. Use I/O link to connect to CNC.
4. Teach pendant has two types those are high--function type and
simplified type.
40
B--81055EN/02 CONTROL UNIT CONNECTION 1.GENERAL
41
1. GENERAL CONTROL UNIT CONNECTION B--81055EN/02
1.3.1
External Dimension of
AC Reactor
(a) A81L--0001--0083#3C
(b) A81L--0001--0126
42
B--81055EN/02 CONTROL UNIT CONNECTION 1.GENERAL
1.4
CONNECTION OF
POWER SUPPLY
CABLE
When the stand--alone controller is used, an optional power cable can be specified.
Connect the primary power cable to the circuit protector. After con-
nection, insulate the protector terminal by fitting the provided termi-
nal cover. Connect the primary power ground wire to the grounding
stud, located beside the circuit protector.
When the robot is shipped, ON, COM, and OFF are connected by
jumper wires. To enable external ON/OFF control, first disconnect
Emergency stop these jumper wires, then make the necessary connections. To
control PCB enable external ON/OFF control, set the circuit protector switch on
the door to ON before setting the external switches.
TBLR
ON
COM
OFF Apply the power ON/OFF timing shown below.
T ON TOFF TOFF--ON
43
1. GENERAL CONTROL UNIT CONNECTION B--81055EN/02
1.5 When the panel--mount controller is used, the preparation of a power cable
and ON/OFF cable is the customer’s responsibility.
CONNECTION OF
THE POWER SUPPLY
Power supply unit
CABLE AND THE CP1
ON/OFF CABLE G
(PANEL MOUNT R 200VAC input
TYPE) S
ON button
CP4
ON
COM
OFF
AL OFF button
FA
Alarm input
FB
Alarm output
CP1 interface
Connector in cable side
3 2 1 JAPAN AMP
G S R Housing : 1--178128--3
Contact : 1--175218--5 (×3)
CP4 interface
Connector in cable side
3 2 1 JAPAN AMP
A COM OFF ON Housing : 2--178129--6
Contact : 1--175218--5 (×6)
(Note) B FB FA AL
NOTE
No connection is required when the AL, FA, and FB of the
CP4 interfaces are not used.
44
B--81055EN/02 CONTROL UNIT CONNECTION 1.GENERAL
1.6
CONNECTORS OF
ROBOT CONTROL
PCB
a) In the case of a 6 axes controller
Robot control
PCB
CRM12 Emergency stop circuit and Brake control circuit
JD1A
Not used
JD4
(JD1B) I/O link (master)
JRS1
Teach pendant
JV6
JV4
JV3
JV1
JF6
Mechanical unit
CRF2
45
2. DETAILS OF CONNECTION CONTROL UNIT CONNECTION B--81055EN/02
2
DETAILS OF CONNECTION
46
B--81055EN/02 CONTROL UNIT CONNECTION 2. DETAILS OF CONNECTION
2.1
FANUC I/O LINK
When the R--J2 Mate control unit is used as a slave of an I/O link
(when a CNC, PLC, or F--D Mate is used as the master of the I/O link)
When the R--J2 Mate control unit is used as the master of the I/O link
(to control the process I/O P.C.B from the R--J2 Mate)
When the R--J2 Mate control unit is used as the master and a slave of an I/O link
JD4 JD1B
R--J2 Mate FANUC I/O
master Unit etc.
JD1B1 JD1A1
JD1B2 JD1A2
JD1A JD1B
CNC,PLC or FANUC I/O
F--D Mate Unit etc.
47
2. DETAILS OF CONNECTION CONTROL UNIT CONNECTION B--81055EN/02
2.2
CONNECTION OF I/O
LINK CABLE
The same interface is used for the panel
mount controllers. Cable connections
JD1A should be made
JD4(JD1B) according to the system. The customer
is requested to ground the shield.
Control printed board
Earth plate
Peel off the sheath of the shielded
cable, then ground the shield here.
I/O Link cable connection (stand--alone controller)
1. Customer should be prepare this cable.
2. Power off when it is connected.
When making a connection with a CNC via an I/O link, apply the following timing to turn
the power to the CNC and robot controller on/off:
a) Turn on the power to the slave units when or before turning on the master power.
b) If the power to the CNC or robot controller is turned off after the system has been
started, an I/O link error will occur. To reestablish normal connection via the I/O link,
turn off the power to all units, then turn on the power as explained in a) above.
11 0V 01 RX 11 0V 01 RX
12 0V 02 *RX 12 0V 02 *RX
13 0V 03 TX 13 0V 03 TX
14 0V 04 *TX 14 0V 04 *TX
15 0V 05 15 0V 05 Connector in cable side
16 0V 06 16 0V 06 Honda Tsuushin Co.,Ltd
Connector: PCR--E20FS
17 07 17 (--15V) 07 (*ENSLC) Case : PCR--V20LA
18 (+5V) 08 18 (+5V) 08 (+15V)
19 09 (+5V) 19 (+24V) 09 (+5V)
20 (+5V) 10 20 (+5V) 10 (+24V)
Note) When using an optical Note) When using I/O signals that are
I/O link adaptor, use +5V. dedicated to the robot, use the
signals and power supplies
indicated in parentheses.
When using an optical I/O link
adaptor, use +5V.
(1) Twisted--pair cables should be used for pin pairs 1 and 2, and 3 and 4.
(2) Use unified shielding, and ground the shield on the CNC side.
48
B--81055EN/02 CONTROL UNIT CONNECTION 2. DETAILS OF CONNECTION
49
2. DETAILS OF CONNECTION CONTROL UNIT CONNECTION B--81055EN/02
50
B--81055EN/02 CONTROL UNIT CONNECTION 2. DETAILS OF CONNECTION
2.3
CONNECTION OF
TEACH PENDANT
2.3.1 · When a panel--mount type controller is used, the teach pendant can be
High Performance Type connected or disconnected with the ON/OFF switch.(See 2.3.3)
Teach Pendant · To obtain a simple connection, provide a connection interface on the
operator’s panel of the machine tool. The following shows an example
of construction.
Operator’s
Earth plate panel
(1) Twisted--pair cables should be used for pin pairs RXTP and *RXTP,
and TXTP and *TXTP.
(2) Use unified shielding, and ground the shield on the CNC side.
51
2. DETAILS OF CONNECTION CONTROL UNIT CONNECTION B--81055EN/02
01 02 03 04
TXTP *TXTP RXTP *RXTP
05 06 07 08 09 10
+24E +24E
11 12 13 14 15 16
EMGTP EMGDM EMGEN Connector in cable side
HIROSE ELECTRIC CO.,LTD
17 18 19 20 Connector:HR22--12TPD--20SC
0V 0V Crimped terminal:HR22--SC--122( 11Pairs)
2.3.2 · When CNC built--in type or a panel--mount type controller is used, the
Simplified Type Teach teach pendant can be connected or disconnected with the ON/OFF
switch. (See 2.3.3)
Pendant
· To obtain a simple connection, provide a connection interface on the
operator’s panel of the machine tool. The following shows an example
of construction.
52
B--81055EN/02 CONTROL UNIT CONNECTION 2. DETAILS OF CONNECTION
(1) Twisted--pair cables should be used for pin pairs 1 and 2, and 3 and 4.
(2) Use unified shielding, and ground the shield on the CNC side.
2.3.3 Prepare the circuit shown below to enable attachment and detachment of
Attaching and the teach pendant. (For the stand--alone controller, an option can be
specified.)
Detaching the Teach
Pendant
Robot control PCB (Note1)
JRS1
Contact 1 Connecting procedure
+24V Internal circuit 1.Connect the teach pendant.
2.Switch ON.
EMGTP
Detachment procedure
1.Switch OFF. (Note2)
2.Detach the teach pendant
Emergency stop
Contact 2
EMGDM
Deadman switch
EMGEN
ON status Enable switch
OFF status
NOTE
1 Contact 1 is not used when attaching/detaching a simplified teach pendant.
2 When the switch is set to OFF, the teach pendants emergency stop function is disabled even
if the teach pendant is connected.
53
2. DETAILS OF CONNECTION CONTROL UNIT CONNECTION B--81055EN/02
Operator’s
panel
Flopply, printer
etc.
Operator’s panel interface (example configuration)
Connection diagram
(Separate type)
JD17 interface
11 TXD 01 RXD 01 FG
14 (TX)
12 0V 02 0V 02 TXD
15 (*TX)
13 DTR 03 DSR 03 RXD
16 (RX)
14 0V 04 0V 04 RTS
17 (*RX)
15 RTS 05 CTS 05 CTS
18
16 0V 06 0V 06 DSR
19
17 (TX) 07 (RX) 07 0V
20 DTR
18 (*TX) 08 (*RX) 08
21
19 +24E 09 09
22
(Note) 20 *ESPOP 10 +24E 10
23
11
Connector in cable side 24
HONDA TSUSHIN CO.,LTD 12
25 +24E
Connector:PCR--E20FS 13
Case:PCR--V20LA
Connector in cable side
(Note)For information about this signal, Connector:DB--25P(Male) or DB
refer to the diagram of the emergency stop circuit. Case:DB--C2--J9
(1) Signals whose names are enclosed in parentheses are assigned to use
the RS--422 interface. The numbers of the interface differ from those
of the standard RS--422 interface. Take the caution when designing
the interface.
(2) Twisted--pair cables should be used for pin pairs 1 and 2, and 3 and 4.,
and ... 19 and 20.
54
B--81055EN/02 CONTROL UNIT CONNECTION 2. DETAILS OF CONNECTION
2.5
CABLE
CONNECTION TO
PERIPHERAL
DEVICE
2.5.1
Peripheral Device
Interface CRM5
D connection to peripheral
device (In the case of
remote type)
CRM5
Earth plate
Peripheral device cable connection Peel off the sheath of the shielded cable, then ground the shield here.
2.5.2 · When a panel mount type controller is used, customer should prepare
When the Robot is this cable.
Connected to the CNC · Turn off the controller when in operation.
Machine by a FANUC
I/O Link
CNC built--in or
panel mount Operator’s panel interface
CRM5
Robot control
Peripheral
PCB device
Operator’s panel
55
2. DETAILS OF CONNECTION CONTROL UNIT CONNECTION B--81055EN/02
2.5.3 · When a panel mount type controller is used, the customer should
When the Robot is prepare this cable.
Connected to the CNC · Turn off the controller when connecting the cable.
Machine by a
Peripheral Device Robot
CRM5
Cable control
PCB
CNC
CRM5 interface (Specified signals are not allocated and the Robot is
connected to CNC machine by a FANUC I/O Link.)
01 SDI101 33 SDO101
Connector in cable side
02 SDI102 34 SDO102 HONDA TSUSHIN CO.,LTD
19 SDICOM1
03 SDI103 35 SDO103 Connector MR--50LMH(Male)
20 SDICOM2
04 SDI104 36 SDO104
21 37
05 SDI105 SDO105
22 SDI117
06 SDI106 38 SDO106
23 SDI118
07 SDI107 39 SDO107
24 SDI119 40
08 SDI108 SDO108
25 SDI120 41
09 SDI109 SDO109
26 42
10 SDI110 SDO110
27 43 SDO111
11 SDI111
28 44 SDO112
12 SDI112
29 0V
13 SDI113 45 SDO113
30 0V
14 SDI114 46 SDO114
31 +24E
15 SDI115 47 SDO115
32 +24E
16 SDI116 48 SDO116
17 0V 49 +24E
18 0V 50 +24E
SDICOM1 and SDICOM2 are the signals used for selecting a common for SDI signals.
To use the +24V common, connect SDICOM1 and SDICOM2 to 0V.
To use the 0V common, connect SDICOM1 and SDICOM2 to +24V.
SDICOM1Selects a common for SDI101 to SDI108.
SDICOM2Selects a common for SDI109 to SDI120.
(Note) Maximum output current per one SDO signal is 70mA.
56
B--81055EN/02 CONTROL UNIT CONNECTION 2. DETAILS OF CONNECTION
CRM5 interface
(standard allocation of specified signals and Connector in cable side
the Robot is connected to the CNC machine HONDA TSUUSHIN CO.,LTD
by a peripheral device cable.) Connector MR--50LMH (Male)
01 SDI101 33 SDO101
02 SDI102 34 SDO102
19 SDICOM1
03 SDI103 35 SDO103
20 SDICOM2
04 SDI104 36 SDO104
21
05 SDI105 37 SDO105
22 SDI117
06 SDI106 38 SDO106
23 SDI118
07 SDI107 39 SDO107
24 SDI119
08 SDI108 40 SDO108
25 SDI120
09 *HOLD 41 SDO109
26
10 RESET 42 SDO110
27
11 START 43 SDO111
28
12 ENBL 44 SDO112
29 0V
13 PNS1 45 CMDENBL
30 0V
14 PNS2 46 FAULT
31 +24E
15 PNS3 47 BATALM
32 +24E
16 PNS4 48 BUSY
17 0V 49 +24E
18 0V 50 +24E
SDICOM1 and SDICOM2 signal are common selection signal for SDI.
When 24 V common is used, connect to 0V.
When 0V common is used, connect to +24V
SDICOM1”Selects a common for SDI101 to SDI108.
SDICOM2”Selects a common for *HOLD, RESET,
START, ENBL, PNS1 to PNS4, and SDI109 to SDI112.
NOTE
1 Maximum output current for one SDO signal is 70mA.
2 The common (selected with SDICOM2) for a dedicated
signal should ideally be the +24V common, but the 0V
common can also be used.
3 Allocation of the specified signals can be changed from the
teach pendant.
57
2. DETAILS OF CONNECTION CONTROL UNIT CONNECTION B--81055EN/02
0V
Fig. 2.5.3 (a) Peripheral device control interface (Input signal, +24V common)
58
B--81055EN/02 CONTROL UNIT CONNECTION 2. DETAILS OF CONNECTION
0V
Fig. 2.5.3 (b) Peripheral device control interface (Input signal, 0V common)
59
2. DETAILS OF CONNECTION CONTROL UNIT CONNECTION B--81055EN/02
0V
60
B--81055EN/02 CONTROL UNIT CONNECTION 2. DETAILS OF CONNECTION
In case +24V common at the peripheral device side (Standard allocation of specified signal)
0V
Fig. 2.5.3 (d) Peripheral device control interface (Input signal, +24 common)
61
2. DETAILS OF CONNECTION CONTROL UNIT CONNECTION B--81055EN/02
In case 0V common at the peripheral device side (Standard allocation of specified signal)
0V
Fig. 2.5.3 (e) Peripheral device control interface (Input signal, 0V common)
62
B--81055EN/02 CONTROL UNIT CONNECTION 2. DETAILS OF CONNECTION
0V
63
2. DETAILS OF CONNECTION CONTROL UNIT CONNECTION B--81055EN/02
2.5.4 This section describes the specifications of the digital I/O signals
Digital I/O Signal interfaced with the peripheral device and end effector.
Specifications
Peripheral Device
Interface CRMS
+24V
0.2 A
or less
0V 0V
+24V
Lamp
0.2 A
or less
0V 0V
Protective resistance
D Electrical specifications
Rated voltage : 24 VDC
Maximum applied voltage : 30 VDC
Maximum load current : 0.2 A
Transistor type : Open collector NPN
Saturation voltage at connection : 1.0 V (approx.)
D Notes on use
Do not use the +24 V power supply of the robot.
When loading a relay, solenoid, and so on directly, connect them in
parallel with diodes for preventing back electromotive force.
If a load causing a surge current such as turning on LED is connected,
use a protective resistance.
D Applicable signal
Output signal of peripheral device interface CRM5 :
SDO101 to SDO116
64
B--81055EN/02 CONTROL UNIT CONNECTION 2. DETAILS OF CONNECTION
+24V
RV
3.3 kτ
+24V
B A
ICOM 0V
TB (Signal) TB (Signal) TB
Peripheral device
contact signal
TC TC TB ; Chattering 5 ms or less
TC ; 5 to 20 ms
D Note on use
Apply the +24 V power of the robot to the receiver.
However, the above signal regulations must be satisfied at the
robot receiver.
D Applicable signal
Input signal of peripheral device interface CRM5 :
SDI101 to SDI120
65
2. DETAILS OF CONNECTION CONTROL UNIT CONNECTION B--81055EN/02
+24V
0.2 A
or less
0V 0V
+24V
Lamp
0.2 A
or less
0V Protective resistance 0V
D Electrical specifications
Rated voltage : 24 VDC
Maximum applied voltage : 30 VDC
Maximum load current : 0.2 A
Transistor type : Open collector NPN
Saturation voltage at connection : 1.0 V (approx.)
D Note on use
The +24 V power supply of the robot can be used when the
endeffector interface is 0.7 A or less.
When loading a relay, solenoid, and so on directly, connect them
in parallel with diodes for preventing back electromotive force.
If a load causing a surge current such as turning on LED is
connected, use a protective resistance.
D Applicable signals
Output signals of the end effector control interface :
RDO1 to RDO6
66
B--81055EN/02 CONTROL UNIT CONNECTION 2. DETAILS OF CONNECTION
+24V
RV
3.3 kτ
+24V
B A
ICOM 0V
TB (Signal) TB (Signal) TB
Peripheral device
contact signal
D Notes on use
Apply the +24 V power of the robot to the receiver.
However, the above signal specifications must be satisfied at the
robot receiver.
D Applicable signals
Input signals of the end effector control interface
RDI1 to RDI4, *HBK, *PPABN
67
2. DETAILS OF CONNECTION CONTROL UNIT CONNECTION B--81055EN/02
2.5.5 The figure below shows the connector for peripheral device cable.
Peripheral Device
Cable Connector
Symbol Name
1 Connector cover
2 Cable clamp screw
3 Connector clamp spring
4 Connector clamp screw
5 Connector 50 pins (male) MR50MH
68
B--81055EN/02 CONTROL UNIT CONNECTION 2. DETAILS OF CONNECTION
2.6
PERIPHERAL
DEVICE INTERFACE
(PROCESS I/O
PRINTED BOARD)
Item Name Drawing number DI DO D/A A/D Remarks
1 Robot control printed circuit A16B--3200--0071 20 16 -- -- Standard
board CRM5
2 Process I/O printed circuit A05B--2300--J030 40 40 2 6 Option (with analog inter-
board CA face)
3 Process I/O printed circuit A05B--2300--J031 40 40 -- -- Option (without analog
board CB interface)
4 Process I/O printed circuit A05B--2300--J035 96 96 -- -- Option (without analog
board DA interface)
5 Welding interface printed cir- A05B--2330--J020 8 8 2 2 Option
cuit board
NOTE
The number of general--purpose I/Os (SDI/SDO) is the
number listed in the table, minus the number of dedicated
signals.
Example: Robot control PC board + process I/O PC board
CB
DI: 20 + 40 -- 8 = 52 points
DO: 16 + 40 -- 4 = 52 points
JD4B CRW1
CRW2
CRW1 and CRW2 are not provided for process I/O printed circuit board.
69
2. DETAILS OF CONNECTION CONTROL UNIT CONNECTION B--81055EN/02
PCB
Weld equipment
70
B--81055EN/02 CONTROL UNIT CONNECTION 2. DETAILS OF CONNECTION
2.6.1
Peripheral Device and
Control Unit
Connection
Control unit
Peripheral device control interface A1
CRM2A
1 SDI121 (Without special 33 SDO121
signal)
2 SDI122 34 SDO122
19 SDO133
3 SDI123 35 SDO123
20 SDO134
4 SDI124 36 SDO124
21 SDO135
5 SDI125 37 COM--A1
22 SDO136
6 SDI126 38 SDO125
23 COM--A4
7 SDI127 39 SDO126
24 SDO137
8 SDI128 40 SDO127
25 SDO138 Peripheral
9 SDI129 41 SDO128 device A1
26 SDO139
10 SDI130 42 COM--A2
27 SDO140
11 SDI131 43 SDO129
28 COM--A5
12 SDI132 44 SDO130
29 SDI137
13 SDI133 45 SDO131
14 30 SDI138
SDI134 46 SDO132
31 SDI139
15 SDI135 47 COM--A3
32 SDI140
16 SDI136 48
17 0V 49 +24E
18 0V 50 +24E
71
2. DETAILS OF CONNECTION CONTROL UNIT CONNECTION B--81055EN/02
NOTE
1 The peripheral device connection cables are optional.
2 All of COM-** are connected to 0 V.
72
B--81055EN/02 CONTROL UNIT CONNECTION 2. DETAILS OF CONNECTION
Control unit
Peripheral device control interface A1
CRM2C
1 SDI161 (Without special 33 SDO161
signal)
2 SDI162 34 SDO162
19 SDO173
3 SDI163 35 SDO163
20 SDO174
4 SDI164 36 SDO164
21 SDO175
5 SDI165 37 COM--C1
22 SDO176
6 SDI166 38 SDO165
23 COM--C4
7 SDI167 39 SDO166
24 SDO177
8 SDI168 40 SDO167
25 SDO178 Peripheral
9 SDI169 41 SDO168 device A3
26 SDO179
10 SDI170 42 COM--C2
27 SDO180
11 SDI171 43 SDO169
28 COM--C5
12 SDI172 44 SDO170
29 SDI177
13 SDI173 45 SDO171
14 30 SDI178
SDI174 46 SDO172
31 SDI179
15 SDI175 47 COM--C3
32 SDI180
16 SDI176 48
17 0V 49 +24E
18 0V 50 +24E
NOTE
1 The peripheral device connection cables are optional.
2 All of COM-** are connected to 0 V.
73
2. DETAILS OF CONNECTION CONTROL UNIT CONNECTION B--81055EN/02
0V
CRM2A (5)
SDI125 RV
CRM2A (6)
SDI126 RV
CRM2A (7)
SDI127 RV
CRM2A (8)
SDI128 RV
CRM2A (9)
SDI129 RV
CRM2A (10)
SDI130 RV
CRM2A (11)
SDI131 RV
CRM2A (12)
SDI132 RV
CRM2A (13)
SDI133 RV
CRM2A (14)
SDI134 RV
CRM2A (15)
SDI135 RV
CRM2A (16)
SDI136 RV
CRM2A (29)
SDI137 RV
CRM2A (30)
SDI138 RV
CRM2A (31)
SDI139 RV
CRM2A (32)
SDI140 RV
+24E
B A
comom switching
set pin
0V
(ICOMI)
NOTE
This is a connection diagram for +24v common.
74
B--81055EN/02 CONTROL UNIT CONNECTION 2. DETAILS OF CONNECTION
CRM2A (34)
SDO122 DV LOAD
CRM2A (35)
SDO123 DV LOAD
CRM2A (36)
SDO124 DV LOAD
CRM2A (38)
SDO125 DV LOAD
CRM2A (39)
SDO126 DV LOAD
CRM2A (40)
SDO127 DV LOAD
CRM2A (41)
SDO128 DV LOAD
CRM2A (43)
SDO129 DV LOAD
CRM2A (44)
SDO130 DV LOAD
CRM2A (45)
SDO131 DV LOAD
CRM2A (46)
SDO132 DV LOAD
CRM2A (19)
SDO133 DV LOAD
CRM2A (20)
SDO134 DV LOAD
CRM2A (21)
SDO135 DV LOAD
CRM2A (22)
SDO136 DV LOAD
CRM2A (24)
SDO137 DV LOAD
CRM2A (25)
SDO138 DV LOAD
CRM2A (26)
SDO139 DV LOAD
CRM2A (27)
SDO140 DV LOAD
CRM2A(23,28,37,
42,47)
0V +24V
+24 V regulated
0V power supply
75
2. DETAILS OF CONNECTION CONTROL UNIT CONNECTION B--81055EN/02
Receiver circuit
CRM2B (1)
SDI141 RV
CRM2B (2)
SDI142 RV
CRM2B (3)
SDI143 RV
CRM2B (4)
SDI144 RV
CRM2B (5)
SDI145 RV
CRM2B (6)
SDI146 RV
CRM2B (7)
SDI147 RV
CRM2B (8)
SDI148 RV
CRM2B (9)
SDI149 RV
CRM2B (10)
SDI150 RV
CRM2B (11)
SDI151 RV
CRM2B (12)
SDI152 RV
CRM2B (13)
SDI153 RV
CRM2B (14)
SDI154 RV
CRM2B (15)
SDI155 RV
CRM2B (16)
SDI156 RV
CRM2B (29)
SDI157 RV
CRM2B (30)
SDI158 RV
CRM2B (31)
SDI159 RV
CRM2B (32)
SDI160 RV
+24E
B A
comom switching
set pin
(ICOM2)
NOTE
This is a connection diagram for +24V common.
76
B--81055EN/02 CONTROL UNIT CONNECTION 2. DETAILS OF CONNECTION
CRM2B (34)
SDO142 DV LOAD
CRM2B (35)
SDO143 DV LOAD
CRM2B (36)
SDO144 DV LOAD
CRM2B (38)
SDO145 DV LOAD
CRM2B (39)
SDO146 DV LOAD
CRM2B (40)
SDO147 DV LOAD
CRM2B (41)
SDO148 DV LOAD
CRM2B (43)
SDO149 DV LOAD
CRM2B (44)
SDO150 DV LOAD
CRM2B (45)
SDO151 DV LOAD
CRM2B (46)
SDO152 DV LOAD
CRM2B (19)
SDO153 DV LOAD
CRM2B (20)
SDO154 DV LOAD
CRM2B (21)
SDO155 DV LOAD
CRM2B (22)
SDO156 DV LOAD
CRM2B (24)
SDO157 DV LOAD
CRM2B (25)
SDO158 DV LOAD
CRM2B (26)
SDO159 DV LOAD
CRM2B (27)
SDO160 DV LOAD
CRM2A(23,28,37,
42,47)
0V +24V
+24 V regulated
0V power supply
77
2. DETAILS OF CONNECTION CONTROL UNIT CONNECTION B--81055EN/02
Receiver circuit
CRM2C (1)
SDI161 RV
CRM2C (2)
SDI162 RV
CRM2C (3)
SDI163 RV
CRM2C (4)
SDI164 RV
CRM2C (5)
SDI165 RV
CRM2C (6)
SDI166 RV
CRM2C (7)
SDI167 RV
CRM2C (8)
SDI168 RV
CRM2C (9)
SDI169 RV
CRM2C (10)
SDI170 RV
CRM2C (11)
SDI171 RV
CRM2C (12)
SDI172 RV
CRM2C (13)
SDI173 RV
CRM2C (14)
SDI174 RV
CRM2C (15)
SDI175 RV
CRM2C (16)
SDI176 RV
CRM2C (29)
SDI177 RV
CRM2C (30)
SDI178 RV
CRM2C (31)
SDI179 RV
CRM2C (32)
SDI180 RV
+24E
B A
comom switching
set pin
0V
(ICOM3)
NOTE
This is a connection diagram for +24V common.
78
B--81055EN/02 CONTROL UNIT CONNECTION 2. DETAILS OF CONNECTION
CRM2C (34)
SDO162 DV LOAD
CRM2C (35)
SDO163 DV LOAD
CRM2C (36)
SDO164 DV LOAD
CRM2C (38)
SDO165 DV LOAD
CRM2C (39)
SDO166 DV LOAD
CRM2C (40)
SDO167 DV LOAD
CRM2C (41)
SDO168 DV LOAD
CRM2C (43)
SDO169 DV LOAD
CRM2C (44)
SDO170 DV LOAD
CRM2C (45)
SDO171 DV LOAD
CRM2C (46)
SDO172 DV LOAD
CRM2C (19)
SDO173 DV LOAD
CRM2C (20)
SDO174 DV LOAD
CRM2C (21)
SDO175 DV LOAD
CRM2C (22)
SDO176 DV LOAD
CRM2C (24)
SDO177 DV LOAD
CRM2C (25)
SDO178 DV LOAD
CRM2C (26)
SDO179 DV LOAD
CRM2C (27)
SDO180 DV LOAD
CRM2C(23,28,37,
42,47)
0V +24V
+24 V regulated
power supply
79
2. DETAILS OF CONNECTION CONTROL UNIT CONNECTION B--81055EN/02
Receiver circuit
CRM2D (1)
SDI181 RV
CRM2D (2)
SDI182 RV
CRM2D (3)
SDI183 RV
CRM2D (4)
SDI184 RV
CRM2D (5)
SDI185 RV
CRM2D (6)
SDI186 RV
CRM2D (7)
SDI187 RV
CRM2D (8)
SDI188 RV
CRM2D (9)
SDI189 RV
CRM2D (10)
SDI190 RV
CRM2D (11)
SDI191 RV
CRM2D (12)
SDI192 RV
CRM2D (13)
SDI193 RV
CRM2D (14)
SDI194 RV
CRM2D (15)
SDI195 RV
CRM2D (16)
SDI196 RV
CRM2D (29)
SDI197 RV
CRM2D (30)
SDI198 RV
CRM2D (31)
SDI199 RV
CRM2D (32)
SDI200 RV
+24E
B A
comom switching
set pin
0V
(ICOM4)
NOTE
This is a connection diagram for +24V common.
80
B--81055EN/02 CONTROL UNIT CONNECTION 2. DETAILS OF CONNECTION
CRM2D (34)
SDO182 DV LOAD
CRM2D (35)
SDO183 DV LOAD
CRM2D (36)
SDO184 DV LOAD
CRM2D (38)
SDO185 DV LOAD
CRM2D (39)
SDO186 DV LOAD
CRM2D (40)
SDO187 DV LOAD
CRM2D (41)
SDO188 DV LOAD
CRM2D (43)
SDO189 DV LOAD
CRM2D (44)
SDO190 DV LOAD
CRM2D (45)
SDO191 DV LOAD
CRM2D (46)
SDO192 DV LOAD
CRM2D (19)
SDO193 DV LOAD
CRM2D (20)
SDO194 DV LOAD
CRM2D (21)
SDO195 DV LOAD
CRM2D (22)
SDO196 DV LOAD
CRM2D (24)
SDO197 DV LOAD
CRM2D (25)
SDO198 DV LOAD
CRM2D (26)
SDO199 DV LOAD
CRM2D (27)
SDO200 DV LOAD
CRM2D(23,28,37,
42,47)
0V +24V
+24 V regulated
0V power supply
81
2. DETAILS OF CONNECTION CONTROL UNIT CONNECTION B--81055EN/02
2.6.2
Connection Between
the Control Unit and
Welder
(Process I/O CA)
Control unit
Welder interface
CRW1
Welder
Peripheral device
NOTE
Welder and peripheral device connection cable is option.
82
B--81055EN/02 CONTROL UNIT CONNECTION 2. DETAILS OF CONNECTION
Welding voltage
command signal
The input impedance
shall be more than 3.3kτ
high--pass filter shall be
provided.
Wire speed
command signal
Welding voltage
detection signal
Output signals
without ripples.
Welding current
detector signal
R=100τ or more
Wire soldering
detector signal
83
2. DETAILS OF CONNECTION CONTROL UNIT CONNECTION B--81055EN/02
Welding start
signal
Gas signal
Wire inching
(positive) signal
Wire inching
(negative) signal
+24V regulated
power supply
Receiver circuit
Arc detection
signal
Gas shortage
detection signal
Wire cut
detection signal
Cooling water
shortage detection
signal
Welding power
supplu abnomality
signal
Common switching
set pin
CRWI (33,34)
Shield
FG (cabinet ground)
NOTE
This is the connection for +24V.
84
B--81055EN/02 CONTROL UNIT CONNECTION 2. DETAILS OF CONNECTION
85
2. DETAILS OF CONNECTION CONTROL UNIT CONNECTION B--81055EN/02
2.6.3
Connection Between
Controller and Weld
Equipment
(Weld Interface Printed
Circuit Board)
Controller
Weld Interface
Weld equipment
86
B--81055EN/02 CONTROL UNIT CONNECTION 2. DETAILS OF CONNECTION
Gas signal
Wire inching
(positive) signal
Wire inching
(negative) signal
Receiver circuit
Arc restart
detection signal
Shield
Cabinet ground
87
2. DETAILS OF CONNECTION CONTROL UNIT CONNECTION B--81055EN/02
Connector
pin number MS connector pin number
Voltage command
Voltage feedback
Current feedback
R=100τ or more
Wire stick
Weld power
88
B--81055EN/02 CONTROL UNIT CONNECTION 2. DETAILS OF CONNECTION
2.6.4 This section describes the specifications of the digital I/O signals
Digital I/O Signal interfaced with the peripheral device, end effector, and arc welder.
Specifications
+24V
0.2 A
or less
0V
+24V
Lamp
0.2 A
or less
0V
Protective resistance
Electrical specifications
Rated voltage : 24 VDC
Maximum applied voltage : 30 VDC
Maximum load current : 0.2 A
Transistor type : Open collector NPN
Saturation voltage at connection : 1.0 V (approx.)
Note on use
Do not use the +24 V power supply of the robot.
When loading a relay, solenoid, and so on directly, connect them in
parallel with diodes for preventing back electromotive force.
If a load is connected causing a surge current when a lamp is turned
on, use a protective resistance.
Applicable signals
Output signals of process I/O printed circuit board CRM2
SDO121 and later
89
2. DETAILS OF CONNECTION CONTROL UNIT CONNECTION B--81055EN/02
RV
3.3 kΩ
+24V
B A
ICOM
TB (Signal) TB (Signal) TB
Peripheral device
contact signal
Note on use
Apply the +24 V power at the robot to the receiver.
However, the above signal specifications must be satisfied at the
robot receiver.
Applicable signals
Input signals of process I/O printed circuit board CRM2
SDI121 and later
90
B--81055EN/02 CONTROL UNIT CONNECTION 2. DETAILS OF CONNECTION
2.6.5
Input/Output Signal
Regulations
+24V
0.2 A
or less
0V
D Electrical specifications
Rated voltage : 24 VDC
Maximum applied voltage : 30 VDC
Maximum load current : 0.2 A
Transistor type : Open collector NPN
Saturation voltage at connection : 1.0 V (approx.)
D Note on use
The +24 V power supply of the robot can be used when the
endeffector interface is 0.7 A or less.
When loading a relay, solenoid, and so on directly, connect them
in parallel with diodes to prevent back electromotive force.
If a load causing a surge current such as turning on LED is
connected, use a protective resistance.
D Applicable signals
Output signals of the end effector control interface :
WDO1--8
91
2. DETAILS OF CONNECTION CONTROL UNIT CONNECTION B--81055EN/02
TB (Signal) TB (Signal) TB
Peripheral device
contact signal
D Notes on use
Apply the +24 V power of the robot to the receiver.
However, the above signal specifications must be satisfied at the
robot receiver.
D Applicable signals
Input signals of the arc welding interface
WDI1--8
92
B--81055EN/02 CONTROL UNIT CONNECTION 2. DETAILS OF CONNECTION
NOTE
Input impedance ; 3.3kτ or more
Provide the high--fregnency filter.
NOTE
Output the signal without ripples
Welding electrode
NOTE
The resistance between the positive (+) and negative (--)
terminals on the weld equipment side should be 100τ or
more.
The wire stick detection signal in TIG welding should be
connected insulating from the weld circuit (high--frequency).
The withstand voltage of this circuit is 80V.
93
2. DETAILS OF CONNECTION CONTROL UNIT CONNECTION B--81055EN/02
Peripheral Device
Interface A Cable
(CRM2: Honda
Tsushin, 50 pins)
Honda Tsushin
Honda Tsushin’s MR50RFH
Supplied with an ordered cable
Peripheral Device
Interface B Cable
(CRM4: Honda
Tsushin, 20 pins)
CRM4*
Honda Tsushin
Honda Tsushin’s MR20RFH
Supplied with an ordered cable
94
B--81055EN/02 CONTROL UNIT CONNECTION 2. DETAILS OF CONNECTION
ARC Weld Connection Be sure to use our cable to connect the welder.
Cable (CRW1: Honda
Tsushin, 34 pins)
ARC welder
Honda Tsushin
Process I/O
Connecting cable for To connect welding equipment, use a cable which conforms to the
arc welding equipment FANUC specifications.
(CRW6: 34 pins,
manufactured by
Yamaichi Electric)
Arc welding
Yamaichi Electric equipment
UFS--34B--04
UFS contact type 66 (X31)
Weld interface
PCB
95
2. DETAILS OF CONNECTION CONTROL UNIT CONNECTION B--81055EN/02
2.6.7 (1) Fig.2.6.7 (a) (b) show the connector for peripheral device cables A
and B.
Peripheral Device
Cable Connector
Symbol Name
¡ Connector cover
© Cable clamp screw
¢ Connector clamp spring
£ Connector clamp screw
¤ Connector 50 pins (male) MR50MH
20 pins (male) MR20MH
Fig. 2.6.7 (a) Peripheral device cable connector (Honda Tsushin Kogyo)
96
B--81055EN/02 CONTROL UNIT CONNECTION 2. DETAILS OF CONNECTION
Symbol Name
¡ Connector clamp screw
© Screw ø2.6_8
¢ Connector (MR50RFH)
(MR20RFH)
97
2. DETAILS OF CONNECTION CONTROL UNIT CONNECTION B--81055EN/02
Electrical characteris-
Conductor Effective
Sheath tics
Number Wire specifications outside
thickness Conductor Allowable
of wires (FANUC specifications) Diameter Configura- diameter
(mm) resistance current
(mm) tion (mm)
(τ/km) (A)
50 A66L-0001-0042 ø1.05 7/0.18 1.5 ø12.5 106 1.6
AWG24
20 A66L-0001-0041 ø1.05 7/0.18 1.5 ø10.5 106 1.6
AWG24
98
B--81055EN/02 CONTROL UNIT CONNECTION 2. DETAILS OF CONNECTION
2.7 · The customer should prepare this cable, when a panel mount type
controller is used.
EMERGENCY STOP
· Turn off the controller when connecitng the cable.
SIGNAL
· Design the system so that the power to the servo amplifier is turned off
CONNECTION when an emergency stop occurs, irrespective of the input of the
emergency stop signal.
CNC built--in or
panel mount
Emergency
Robot CRM12 stop button
control
PCB
Operator’s panel
CRM12 interface
99
2. DETAILS OF CONNECTION CONTROL UNIT CONNECTION B--81055EN/02
2.8
EMERGENCY STOP
CIRCUIT
2.8.1
Circuit Diagram of
Emergency Stop (In the
Case of Remote Type)
High--performance
type teach pendant
+24E
JRS3
EMGTP
Emergency stop switch
EMGDM
Dead man switch
EMGEN
Enable switch
*ESPOP
EMGIN1
CRM12
EMGINC
0V EMGIN2
Robot control
EMGOUT
PCB
0V CX3
CRR17
BRK
EMG1 CX4
Servo amp.
0V (PSM)
EMGOUT1
emgout
emg1 EMGOUT2
200A
emg1
200B
MCC
3χ 200VAC
100
B--81055EN/02 CONTROL UNIT CONNECTION 2. DETAILS OF CONNECTION
2.8.2
Circuit Diagram of
Emergency Stop
(CNC Built--in Type or
Panel Mount Type)
High--performance Simplified type
type teach pendant teach pendant
+24E JRS3
EMGTP
Emergency stop switch Emergency
EMGDM stop switch
Dead man switch
EMGEN
Enable switch
JD17
Emergency stop
(Note1) control circuit
(Shall be prepared by customer)
CX4
0V
Robot control PCB
emg1
100A
MCC
emg1
(Note4)
100B
*BKON 3χ 200VAC
100IN1
100IN2
CNBK
T1
For robot brake
101
2. DETAILS OF CONNECTION CONTROL UNIT CONNECTION B--81055EN/02
NOTE
1 Draw *ESPOP from a location between the emergency stop
switch and the contact of the servo amplifier. Connect
*ESPOP to either CRM12 or JD17.
2 Position the emergency stop switch at a location prior to the
servo amplifier contact. For the emergency stop switch, use
a contact with a rating of 250V/10A or greater.
3 Relay specifications
Rated voltage of coil: 24VDC
Max. contact current: 10A
Max. contact voltage: 380VAC
Use a relay with a built--in diode.
4 MCC specifications
Rated coil voltage: 100VAC
Rated current: 20A
5 Those items that are available from FANUC are indicated by
the shading.
2.8.3
External Emergency
Stop Input (In the Case
of Remote Type)
When the robot is shipped, EMGIN1, INC, and IN2 are con-
nected by jumper wires. To enable external emergency stop
TBLR input, first disconnect these jumper wires, then make the neces-
EMGIN1 sary connections.
External emergency stop input #1 is reflected in the external
EMGINC emergency stop output, but external emergency stop input #2 is
EMGIN2 not reflected in the external emergency stop output.
Confirm the operation of emergency stop switches on the teach
pendant and on the front panel, after you wired the external
emergency stop input.
External External
emergency emergency
stop input #1 stop input #2
102
B--81055EN/02 CONTROL UNIT CONNECTION 2. DETAILS OF CONNECTION
2.8.4
External Emergency
Stop Output (In the
Case of Remote Type)
A cable holder is provided at
each circled d location.
Customer should
prepare this cable
Circuit
Emergency stop R--J2 Mate
control PCB EMGOUT1
EMGOUT2
TBLR
EMGOUT1 The printed circuit board features a relay that opens at emergency stop.
EMGOUT2
An emergency stop button on the teach pen-
dant, deadman’s switch (provided on a high--
performance type teah pendant only), an
emergency stop button on the control unit
door, and external emergency stop input #1
are reflected in the external emergency stop
For peripheral control output.
For sequencer etc.
103
2. DETAILS OF CONNECTION CONTROL UNIT CONNECTION B--81055EN/02
BKP1
100IN2
Spark killer
Absorber
From Emergency stop circuit Relay
MCON
BKM1
BKP2
*BKON
BKM2
Robot control
PCB BKP3
BKM3
CRM12
Terminal block ; T1 (Note)
NOTE
For terminal block (T1) connection, use an M4 crimp terminal.
104
B--81055EN/02 CONTROL UNIT CONNECTION 2. DETAILS OF CONNECTION
CNBK
Servo amp.
M1
105
2. DETAILS OF CONNECTION CONTROL UNIT CONNECTION B--81055EN/02
2.10 Customer should prepare this cable when a panel mount type controller
is used.
CONNECTION OF Also refer to descriptions of servo amplifier for connection on this type
SERVO AMPLIFIER of controller.
Emergency
stop circuit CX3 JV1B JV1B
(1) Twisted--pair cables should be used for pin pairs 1 and 2, and 3 and 4,
...19 and 20.
(2) Use unified shielding, and ground the shield on the CNC side.
106
B--81055EN/02 CONTROL UNIT CONNECTION 2. DETAILS OF CONNECTION
2.11
CONNECTION TO
ROBOT
(IN THE CASE OF
REMOTE TYPE)
Connection to robot Customer should prepare these cables when optional robot connection
cables are not used with panel mount type controller is equipped.
Robot
control
PCB
RM
CRF2 RP
107
2. DETAILS OF CONNECTION CONTROL UNIT CONNECTION B--81055EN/02
D Connection of cable RP
CRF2 interface
33 PD4 01 PD1
34 *PD4 02 *PD1
19 PD3
35 PRQ4 03 PRQ1
20 *PD3
36 *PRQ4 04 *PRQ1
21 PRQ3
37 PD5 05 PD2
22 *PRQ3
38 *PD5 06 *PD2
23 0V
39 PRQ5 07 PRQ2
24 0V
40 *PRQ5 08 *PRQ2
25 0V
41 RDO01 09 RDI01
26 0V
42 RDO02 10 RDI02
27 0V
43 RDO03 11 RDI03
28 +5V
44 RDO04 12 RDI04
29 +5V
45 RDO05 13 RDI05
30 +5V
46 RDO06 14 RDICOM
31 +5V
47 15 *ROT
32 +5V
48 16 *HBK
49 +24E 17 *PPABN
50 +24E 18 0V
108
B--81055EN/02 CONTROL UNIT CONNECTION 2. DETAILS OF CONNECTION
D Connection of cable RM
SVM1 SVM2
A06B--6079--H301 A06B--6079--H301
UL VL UM VM UN VN UL VL UM VM UN VN
J11 J12 J21 J22 J31 J32 J41 J42 J51 J52 J61 J62
WL PE WM PE WN PE WL PE WM PE WN PE
J13 J1G J23 J2G J33 J3G J43 J46 J53 J5G J63 J6G
For robot
109
2. DETAILS OF CONNECTION CONTROL UNIT CONNECTION B--81055EN/02
2.12 In this manual the treatment for the shielded cable is shown on several
pages. Partly cut off the shielded cable to expose the shield jacket, and
TREATMENT FOR fasten the jacket to the shield plate with a clamp to protect against noise.
THE SHIELDED (In case of stand--alone type a shield plate is installed in the controller, but
CABLE in case of panel--mounting type the shield should be prepared by
customer.)
110
3. TRANSPORTATION AND
B--81055EN/02 CONTROL UNIT CONNECTION INSTALLATION
3
TRANSPORTATION AND INSTALLATION
111
3. TRANSPORTATION AND
INSTALLATION CONTROL UNIT CONNECTION B--81055EN/02
3.1 The control unit should be transported by a crane. Attach a rope to eye
bolts at the top of the control unit.
TRANSPORTATION
112
3. TRANSPORTATION AND
B--81055EN/02 CONTROL UNIT CONNECTION INSTALLATION
3.3
EXTERNAL
CONTROLLER
DIMENSIONS
113
3. TRANSPORTATION AND
INSTALLATION CONTROL UNIT CONNECTION B--81055EN/02
3.4
INSTALLATION Item Specifications/condition
CONDITION Transformer 50Hz; 200VAC, +10%, --15%
60Hz; 200VAC to 220 VAC, +10%, --15%
50/60 Hz1Hz, 3--phase
Input power supply capacity 1.2 kVA
Average power consumption 0.5 kW
Ambient temperature range 0 to 45 n
Ambient humidity range 75% RH max.
No condensation
95% RH maximum for up to 1 month.
Atmosphere No corrosive gases
Contact FANUC when operating the unit
where there is a lot of dust or cutting oil.
Vibration 0.5G max.
Contact us when operating the unit where
vibration frequently occurs.
Weight of control unit 40kg
114
3. TRANSPORTATION AND
B--81055EN/02 CONTROL UNIT CONNECTION INSTALLATION
3.6 An overtravel and emergency stop occur when the robot is operated for
the first time after it is installed and the mechanical and control units are
RESETTING wired. This section describes how to reset the overtrvel and emergency
OVERTRAVEL AND stop.
EMERGENCY STOP Remove the red plate fastening the swiveling axis beforehand.
AT INSTALLATION The J2 and J3 axes are pressed against the hard stops at shipment.
Therefore, an overtravel alarm occurs when the power is turned on after
installation.
115