Location via proxy:   [ UP ]  
[Report a bug]   [Manage cookies]                

User's Guide: FMG-1000-SK

Download as pdf or txt
Download as pdf or txt
You are on page 1of 8

User's Guide

Shop online at

omega.com
email: Info@omega.com
For latest product manuals:
omegamanual.Info

FMG-1000-SK
Solar Panel
OMEGAnet ® Online Service Internet e-mail
omega.com info@omega.com
Servicing North America:
U.S.A.: One Omega Drive, P.O. Box 4047
ISO 9001 Certified Stamford, CT 06907-0047
TEL: (203) 359-1660 FAX: (203) 359-7700
e-mail: info@omega.com
Canada: 976 Bergar
Laval (Quebec) H7L 5A1, Canada
TEL: (514) 856-6928 FAX: (514) 856-6886
e-mail: info@omega.ca

For immediate technical or application assistance:


U.S.A. and Canada: Sales Service: 1-800-826-6342 / 1-800-TC-OMEGA®
Customer Service: 1-800-622-2378 / 1-800-622-BEST®
Engineering Service: 1-800-872-9436 / 1-800-USA-WHEN®
TELEX: 996404 EASYLINK: 62968934 CABLE: OMEGA

Mexico: En Español: (001) 203-359-7803 e-mail: espanol@omega.com


FAX: (001) 203-359-7807 info@omega.com.mx

Servicing Europe:
Benelux: Postbus 8034, 1180 LA Amstelveen, The Netherlands
TEL: +31 (0)20 3472121 FAX: +31 (0)20 6434643
Toll Free in Benelux: 0800 0993344
e-mail: sales@omegaeng.nl
Czech Republic: Frystatska 184, 733 01 Karviná, Czech Republic
TEL: +420 (0)59 6311899 FAX: +420 (0)59 6311114
Toll Free: 0800-1-66342 e-mail: info@omegashop.cz
France: 11, rue Jacques Cartier, 78280 Guyancourt, France
TEL: +33 (0)1 61 37 2900 FAX: +33 (0)1 30 57 5427
Toll Free in France: 0800 466 342
e-mail: sales@omega.fr
Germany/Austria: Daimlerstrasse 26, D-75392 Deckenpfronn, Germany
TEL: +49 (0)7056 9398-0 FAX: +49 (0)7056 9398-29
Toll Free in Germany: 0800 639 7678
e-mail: info@omega.de
United Kingdom: One Omega Drive, River Bend Technology Centre
ISO 9002 Certified Northbank, Irlam, Manchester
M44 5BD United Kingdom
TEL: +44 (0)161 777 6611 FAX: +44 (0)161 777 6622
Toll Free in United Kingdom: 0800-488-488
e-mail: sales@omega.co.uk

It is the policy of OMEGA Engineering, Inc. to comply with all worldwide safety and EMC/EMI
regulations that apply. OMEGA is constantly pursuing certification of its products to the European New
Approach Directives. OMEGA will add the CE mark to every appropriate device upon certification.
The information contained in this document is believed to be correct, but OMEGA accepts no liability for any
errors it contains, and reserves the right to alter specifications without notice.
WARNING: These products are not designed for use in, and should not be used for, human applications.
FEATURES
• Includes 5 watt solar panel, mounting hardware,
and 12V solar charge controller
• Reliable, maintenance-free operation
• Powers many flow meter products with the addition
of a low cost 22-33 Amp-hour Sealed Lead Acid
battery

APPLICATIONS
• Remote metering applications where electricity is
unavailable
• Back-up power supply for uninterrupted operation

GENERAL INFORMATION
The FMG-1000-SK solar panel makes it possible to use Omega charge controller and corrossion-resistant mounting hardware.
flowmeters in remote applications where a reliable source of The FMG-1000-SK can also be used to provide up to a 40-day
electricity is not available or practical. The FMG-1000-SK is back-up power supply for periods of darkness.
intended for use with a standard 12V, 22-33 Amp-hour Sealed
Lead Acid battery (not included). It comes standard with a

Page 1
SPECIFICATIONS*
Electrical Current 290 mA (typical at design operating point)
Voltage 17 V (typical at design operating point)
Dimensions Height 14.2”
Width 8.5”
Weight 4 pounds (solar panel and mounting bracket)
Mounting Bracket, band clamps and mounting hardware for 1-1/2 or 2 inch vertical pipe
Operating Temperature Range -40˚ F to +158˚ F (-40˚ C to +70˚ C)
Change Controller High efficiency series PWM regulator with temperature compensation and built-in lightning protection
*Specifications subject to change

BATTERY SELECTION
For powering mechanical meters along with display electron- ating continuously through the year, or in latitudes above 50
ics, use a 12V Sealed Lead Acid (SLA) deep-cycle battery with degrees, the required battery Amp-hour capacity should be
a minimum capacity of 22 Amp-hours. This should provide a reviewed before selection.
conservative 40 day backup with maximum battery service
life. Marine/RV grade deep-cycle batteries or automotive bat- In summary, the minimum recommended battery capacity, as
teries may be used but must be upsized in Amp-hour capacity described above, will be adequate in most climates and ap-
by two times and four times respectively to achieve the same plications. However, under marginal conditions, a larger ca-
battery service life in most applications. pacity battery may provide superior reliability, better battery
service life and lower life-cycle costs.
For powering low power (<50mA) magnetic flow meters, use
only deep-cycle SLA batteries (not marine/RV orautomotive
grade batteries) with a minimum capacity of 33 Amp-hours.
In climates where meters are operating in full pipe mode
much of the time with extended periods of cloudy days, oper-

LOCATION
The solar panel should oriented as much as possible toward If the battery and Solar Charge Controller are housed in an
the midday sun. Locate where there is no significant shading enclosure, the outside must be white or shiny metallic to mini-
of the solar panel. The Solar Charge Controller and Sealed mize solar heat build up inside that is seriously detrimental
Lead Acid (SLA) battery should be located in close physical to the service life of the battery. Even light colors (such as the
and thermal proximity. Both must be shaded from direct standard ANSI 61 Gray) can elevate the interior of the enclosure
sunlight to minimize temperature differences between them by 40F (22C.) If other colors are used, the enclosure must be
which will greatly diminish the battery service life. Also insulate shaded from direct sunlight or painted glossy white. In addition,
the bottom of the battery if heat could be absorbed from the because even sealed batteries could vent if the Solar Charge
surface (concrete, metal etc.) on which the battery is resting. Controller fails, for safety reasons the enclosure should be
Also take measures to prevent accumulation of moisture (rain, vented, particularly if it contains other electrical equipment.
snow, ice, flooding) between the battery terminals which could
discharge the battery.

Page 2
INSTALLATION
The solar panel is designed to mount to a either a 1-1/2 to 2 the two band clamps as shown. Turn the panel to face true (not
inch diameter vertical pipe. First attach the 45 degree angle magnetic) south in the northern hemisphere or north in the
bracket to the panel with the two M6 bolts, flat washers and southern hemisphere before tightening the clamps securely.
nuts provided as shown. Before tightening the bolts. Be sure to
position the bracket to the side of the black cable cover rather Connect the solar charge controller, flow meter and battery
than over it to avoid stressing the panel. (At latitudes above 50 as shown in the wiring diagram. Clean battery terminals and
degrees performance may be improved by bending the bracket secure connections to the battery using grease or other means
so that the angle of the panel to the horizontal is increased of preventing corrosion. For safety, an in-line fuse holder should
to approximately the local latitude plus 15 degrees. To avoid be installed at the positive battery connection with a 1 Amp
damage to the panel, do this before bolting the bracket to the time lag (slow-blow) fuse. In unprotected locations a weather-
panel). Next use the two sets of ¼-20 bolts, nuts, flat and proof fuse holder (such as Bussmann HFB-R) and outdoor-rated
lock washers to attach the angle bracket to the pipe mount wirenuts should be used.
C-channel. Then attach the entire assembly to the pipe using

1-1/2 to 2 inch pipe

1/4-20 hardware C-channel band clamps

solar panel

M6 hardware

Page 3
WIRING DIAGRAM

wirenut connectors,
4 places red
Flow Sensor
black
or Display

black black

red

red
yellow black black red
fuse holder
with 1A fuse
SOLAR BATTERY

Solar Charge Controller 12V SLA


Battery

MAINTENANCE
Periodic cleaning of the solar panel glass is recommended to most areas. Battery service life for good quality SLA batteries
remove dust accumulation. Snow and ice may need remov- should be 4-6 years. Actual maintenance replacement inter-
al if it remains more than 2 weeks. Installing the panel at a val will depend on local conditions and criticality of data.
steeper than 45 degree angle may make this unnecessary in

®
ENGINEERING, INC.

Page 4
WARRANTY/DISCLAIMER
OMEGA ENGINEERING, INC. warrants this unit to be free of defects in materials and workmanship for a
period of 13 months f rom date of purchase. OMEGA’s WARRANTY adds an additional one (1) month
grace period to the normal one (1) year product warranty to cover handling and shipping time. This
ensures that OMEGA’s customers receive maximum coverage on each product.
If the unit malfunctions, it must be returned to the factory for evaluation. OMEGA’s Customer Serv i c e
D e p a rtment will issue an Authorized Return (AR) number immediately upon phone or written request.
Upon examination by OMEGA, if the unit is found to be defective, it will be re p a i red or replaced at no
c h a rge. OMEGA’s WARRANTY does not apply to defects resulting from any action of the purchaser,
including but not limited to mishandling, improper interfacing, operation outside of design limits,
i m p roper repair, or unauthorized modification. This WARRANTY is VOID if the unit shows evidence of
having been tampered with or shows evidence of having been damaged as a result of excessive corrosion;
or current, heat, moisture or vibration; improper specification; misapplication; misuse or other operating
conditions outside of OMEGA’s control. Components in which wear is not warranted, include but are not
limited to contact points, fuses, and triacs.
OMEGA is pleased to offer suggestions on the use of its various products. However,
OMEGA neither assumes responsibility for any omissions or errors nor assumes liability for any
damages that result from the use of its products in accordance with information provided by
OMEGA, either verbal or written. OMEGA warrants only that the parts manufactured by the
company will be as specified and free of defects. OMEGA MAKES NO OTHER WARRANTIES OR
REPRESENTATIONS OF ANY KIND WHATSOEVER, EXPRESSED OR IMPLIED, EXCEPT THAT OF
TITLE, AND ALL IMPLIED WARRANTIES INCLUDING ANY WARRANTY OF MERCHANTABILITY
AND FITNESS FOR A PARTICULAR PURPOSE ARE HEREBY DISCLAIMED. LIMITATION OF
LIABILITY: The remedies of purchaser set forth herein are exclusive, and the total liability of
OMEGA with respect to this ord e r, whether based on contract, warr a n t y, negligence,
indemnification, strict liability or otherwise, shall not exceed the purchase price of the
component upon which liability is based. In no event shall OMEGA be liable for
consequential, incidental or special damages.
CONDITIONS: Equipment sold by OMEGA is not intended to be used, nor shall it be used: (1) as a “Basic
Component” under 10 CFR 21 (NRC), used in or with any nuclear installation or activity; or (2) in medical
applications or used on humans. Should any Product(s) be used in or with any nuclear installation or
activity, medical application, used on humans, or misused in any way, OMEGA assumes no responsibility
as set forth in our basic WARRANTY/ DISCLAIMER language, and, additionally, purchaser will indemnify
OMEGA and hold OMEGA h a rmless from any liability or damage whatsoever arising out of the use of the
P roduct(s) in such a manner.
RETURN REQUESTS/INQUIRIES
Direct all warranty and repair requests/inquiries to the OMEGA Customer Service Department. BEFORE
RETURNING ANY PRODUCT(S) TO OMEGA, PURCHASER MUST OBTAIN AN AUTHORIZED RETURN
(AR) NUMBER FROM OMEGA’S CUSTOMER SERVICE DEPA RTMENT (IN ORDER TO AV O I D
PROCESSING DELAYS). The assigned AR number should then be marked on the outside of the return
package and on any correspondence.
The purchaser is responsible for shipping charges, freight, insurance and proper packaging to prevent
breakage in transit.
FOR WARRANTY RETURNS, please have the FOR NON-WARRANTY REPAIRS, consult OMEGA
following information available BEFORE for current repair charges. Have the following
contacting OMEGA: information available BEFORE contacting OMEGA:
1. Purchase Order number under which the product 1. Purchase Order number to cover the COST
was PURCHASED, of the repair,
2. Model and serial number of the product under 2. Model and serial number of the product, and
warranty, and 3. Repair instructions and/or specific problems
3. Repair instructions and/or specific problems relative to the product.
relative to the product.
OMEGA’s policy is to make running changes, not model changes, whenever an improvement is possible. This affords
our customers the latest in technology and engineering.
OMEGA is a registered trademark of OMEGA ENGINEERING, INC.
© Copyright 2005 OMEGA ENGINEERING, INC. All rights reserved. This document may not be copied, photocopied,
reproduced, translated, or reduced to any electronic medium or machine-readable form, in whole or in part, without the
prior written consent of OMEGA ENGINEERING, INC.
Where Do I Find Eve rything I Need for
Process Measurement and Control?
OMEGA…Of Course!
Shop online at omega.com
TEMPERATURE

 Thermocouple, RTD & Thermistor Probes, Connectors, Panels & Assemblies

 Wire: Thermocouple, RTD & Thermistor

 Calibrators & Ice Point References

 Recorders, Controllers & Process Monitors

 Infrared Pyrometers

PRESSURE, STRAIN AND FORCE



 Transducers & Strain Gages

 Load Cells & Pressure Gages

 Displacement Transducers

 Instrumentation & Accessories

FLOW/LEVEL

 Rotameters, Gas Mass Flowmeters & Flow Computers

 Air Velocity Indicators

 Turbine/Paddlewheel Systems

 Totalizers & Batch Controllers

pH/CONDUCTIVITY

 pH Electrodes, Testers & Accessories

 Benchtop/Laboratory Meters

 Controllers, Calibrators, Simulators & Pumps

 Industrial pH & Conductivity Equipment

DATA ACQUISITION

 Data Acquisition & Engineering Software

 Communications-Based Acquisition Systems

 Plug-in Cards for Apple, IBM & Compatibles

 Datalogging Systems

 Recorders, Printers & Plotters

HEATERS

 Heating Cable

 Cartridge & Strip Heaters

 Immersion & Band Heaters

 Flexible Heaters

 Laboratory Heaters

ENVIRONMENTAL
MONITORING AND CONTROL

 Metering & Control Instrumentation

 Refractometers

 Pumps & Tubing

 Air, Soil & Water Monitors

 Industrial Water & Wastewater Treatment

 pH, Conductivity & Dissolved Oxygen Instruments

M-4173/0505

PL-OM-12424-C
3/28/11 M-4384/0311

You might also like