A Series Air Cooled and Vacuum Pump Brochure
A Series Air Cooled and Vacuum Pump Brochure
A Series Air Cooled and Vacuum Pump Brochure
A-Series
GARDNER DENVER | A-SERIES
Rugged Durability
Premium Performance
A Winning Combination
Gardner Denver compressors are proven units,
known for their reliability over decades of use.
We know our products and understand how they
operate in many different operating environments.
No matter the application, Gardner Denver gets
the job done.
2
Accessibility & Reliability
Gardner Denver A-Series reputation is built on quality,
reliability and accessibility to all components. With
a broad range of models, A-Series compressors are
designed to provide optimum performance in a wide
variety of operations. Regardless of the application,
Gardner Denver gets the job done.
3
Meet the A-Series
4
Air Compressors,
Vacuum & Boosters
AC UU M 350
V psig
E
28"
R
RE
SSU
P
Hg
UP TO 40 HP
FEATURES
■■ ASME pressure relief valve protects the intercooler ■■ Suctionunloading valves (where applicable) provide
and first stage from over pressure. loadless starting and stopping as well as quick
response to capacity demands.
■■ Tri-Metal
insert bearings are two-piece for quick
and easy replacement. Counterbalanced crankshaft ■■ Deep-finned cylinders and heads quickly dissipate
assures smooth operation. the head of compression.
■■ Replaceable piston pin bearings are very economical ■■ Crankshaft ends are supported by large tapered
when replacement becomes necessary. The roller bearings for smooth operation and long life.
generously sized intercooler provides maximum
■■ Oil
pressure gauge assures the operator of
cooling for the most efficient operation and low
power consumption. (AVLAVCAA-GD only) lubrication system integrity.
5
Reciprocating
Service
Options
Benefit
Design Reliable
Dependable
Solution
Confidence
Technology
Durability Package
Value
Convenience
Competitive
Performance
Longevity
6
Sales & Service Distributors
Across America
An Extensive Network
By leveraging the extensive network of Gardner Denver
factory-trained authorized local distributors, your sales, service
and technical support needs can be handled quickly and easily.
7
A–Series Bares
Compressor designs optimized for premium service in the following applications:
DIMENSIONS
MODEL
BORE
STROKE
SUCTION &
DISCHARGE
DIMENSIONS
WEIGHT
28" HG–60 PSIG
DIAMETER L×W×H
PIPE SIZE NPT (0.95–4.1 BAR)
in 7.875/7.875 3 3 41 × 29 × 30 lbs 750
APL CONTINUOUS OPERATION
mm 200 76 NA 1041 × 737 × 762 kg 340
8
DIMENSIONS
SUCTION &
BORE DISCHARGE DIMENSIONS
MODEL STROKE WEIGHT
DIAMETER PIPE SIZE L×W×H
NPT
DIMENSIONS
SUCTION &
BORE DISCHARGE DIMENSIONS
MODEL STROKE DISCHARGE WEIGHT
DIAMETER PIPE SIZE L×W×H
NPT
■■ Single-Stage
Vacuum
in 8.00/4.25 4.50 2 2 40 × 27 × 33 lbs 680
AVLAVCAA-GD and Booster Bare
mm 203/108 114 NA NA 1016 × 686 × 838 kg 308
■■ Two-Stage Air Compressor Bare
in 4.25/4.25 4.50 3 2 38 × 27 × 33 lbs 600
AVLANCAA-GD
mm 108 114 NA NA 965 × 686 × 838 kg 272 ■■ Pressure Lubricated
in 7.50/7.50 3 3 3 38 × 27 × 33 lbs 600 ■■ Factory Fill with AEON 500
AVLEKCAA-GD
mm 191 76 NA NA 965 × 686 × 838 kg 272
■■ Cast Iron Construction
COMPRESSOR SPECIFICATIONS
PRESSURE CAPACITY
MODEL HP/KW SPEED
PSIG BAR CFM M3/MIN
25" HG–350 PSIG
968 100 6.90 101 2.86
(6.9–17.24 BAR
922 125 8.62 96.5 2.73
25/19
830 175 12.07 85 2.41 CONTINUOUS
784 250 17.24 78 2.21 OPERATION
AVLAVCAA-GD
1106 100 6.90 116 3.29
7.5–40 HP
1014 125 8.62 105 2.97
30/22 (5.6–30 KW)
968 175 12.07 99 2.80 AVLANCAA-GD
876 250 17.24 87 2.46 Single-Stage Booster
Suction Pressures: 1–140 psig
Discharge Pressure: Up to 350 psig
AVLANCAA-GD 40/30
Consult factory for sizing
& technical information.
VACUUM SPECIFICATIONS
SPEED CAPACITY VAC. - HG
MODEL
HP/KW CFM M3/MIN IN MM
ANPEAA-GD, ANPHAA-GD
Ideal for use in natural gas gathering applications
COMPRESSOR SPECIFICATIONS
DESCRIPTION ANPHAA-GD ANPEAA-GD
Bore & Stroke (inches) 7.87 & 7.87 × 4.5 4.25 & 4.25 × 4.5
Number Cylinders 2 2
10
ANPHAA PERFORMANCE @ 968 RPM
DISCHARGE PSIG
MSCFD
10 15 20 25 30 35 40 45 50 55 60
-10 70.4 66.3 62.3 58.5
-5 180.1 172.7 165.5 158.4 150.7 146.5 142.3 138.2 134.2 130.2 126.3
0 292.7 284.8 277.2 269.6 262.3 255.0 247.9 240.8 233.8 226.8 222.5
5 406.0 397.8 389.8 381.9 374.2 366.6 359.2 351.8 344.5 337.3 330.2
SUCTION PSIG
10 511.3 502.9 494.8 486.8 479.0 471.3 463.7 456.1 448.7 441.3
15 608.1 599.9 591.9 583.9 576.1 568.3 560.7 553.1
20 713.3 705.0 696.9 688.9 681.0 673.2 665.4
25 818.5 810.2 802.0 793.9 786.0 778.1
30 923.7 915.4 907.2 899.0 891.0
35 1028.9 1020.6 1012.3 1004.1
40 1125.8 1117.5
45 1231.0
DISCHARGE PSIG
BHP
10 15 20 25 30 35 40 45 50 55 60
-10 9.1 10.1 11.1 12.0
-5 12.7 14.3 15.5 16.5 17.3 18.4 19.5 20.5 21.5 22.5 23.4
0 12.5 15.5 18.0 20.0 21.6 22.9 24.0 25.0 25.9 26.7 27.8
5 10.4 14.5 17.8 20.7 23.3 25.5 27.3 28.9 30.2 31.3 32.4
SUCTION PSIG
10 11.7 16.2 19.8 23.0 25.9 28.5 30.9 32.9 34.6 36.1
15 17.9 21.7 25.1 28.2 31.1 33.8 36.2 38.3
20 19.4 23.5 27.0 30.3 33.4 36.3 39.0
25 20.9 25.2 28.9 32.3 35.5 38.6
30 22.2 26.8 30.7 34.3 37.6
35 23.4 28.4 32.5 36.1
40 29.8 34.1
45 31.2
Note: Sweet Natural Gas with N Value of 1.3; MSCFD = Flow at 14.7 PSIA and 60° F
DISCHARGE PSIG
BHP
50 75 100 125 150 175 200 225 250
0 6.4 6.8 6.8
10 8.9 10.2 10.7 11.2 11.5 11.4 11.0
20 9.4 12.4 14.0 14.7 15.1 15.7 16.0 16.1 16.0
30 8.8 13.0 15.9 17.6 18.5 19.1 19.5 20.0 20.4
SUCTION PSIG
11
GARDNER DENVER | A-SERIES