DESCRIPTION
® The 10 SEER Series condensing unit is the outdoor part of a
versatile system of air conditioning. It is designed to be cus-
tom-matched with one of UPG’s complete line of evaporator
sections, each designed to serve a specific function. Match-
ing Air Handlers are available for upflow, downflow or hori-
zontal applications to provide a complete system. Electric
Heaters are available if required. Add-On coils are available
for use with upflow, downflow or horizontal furnaces and air
handlers.
AIR
M
-C
ER
PL
ON
Y
MA N U F A C T U R
RY
NI
D
TA
IT
OI
G W IT H
UN I
RT
O
E
IF NS
A I CA T IO
RI T I ON S E C 10
S T A NDA R D 2
motor-bearings need no annual servicing.
LISTED
This product was manufactured Certification applies only
in a plant whose quality system
is certified/registered as being
when the complete
system is listed
• EASY SERVICE ACCESS - Fully exposed refrigerant con-
in conformity with ISO 9001. with ARI. nections, a single panel covering the electrical controls
Due to continuous product improvement, specifica- and the molex plug in the control box connecting the con-
tions are subject to change without notice. denser fan, make for easy servicing of the unit.
• SECURED SERVICE VALVES - Secured re-usable ser-
Visit us on the web at www.york.com for the most
vice valves are provided on both the liquid and vapor
up-to-date technical information. sweat connections for ease of evacuating and charging.
Additional rating information can be found at • U.L. and C.U.L. listed - approved for outdoor application.
www.ariprimenet.org. Certified in accordance with the Unitary Small Equipment cer-
tification program, which is based on ARI Standard 210/240.
Compressor Type 3 Recip Recip Recip ScrollB ScrollB Dual Recip Recip Recip ScrollB ScrollB Dual
Rated Load 10.9 12.8 11.7 16.0 18.9 29.4 5.8 6.1 6.1 8.0 9.5 14.0
Compressor Amps
Locked Rotor 78 78 78 125 146 260 40 39 39 67 73 128
Crankcase Heater No No No No No Yes No No No No No Yes
Fan Motor Amps Rated Load 1.4 1.4 1.3 1.3 2.2 4.6 .8 .8 .7 .8 1.2 2.3
Fan Diameter Inches 18 18 22 22 24 24 18 18 22 22 24 24
Rated HP 1/4 1/4 1/4 1/4 1/3 3/4 1/4 1/4 1/5 1/4 1/3 3/4
Fan Motor Nominal RPM 1,100 1,100 850 850 1100 1100 1,100 1,100 850 850 1100 1100
Nominal CFM 2,750 2,750 3,250 3,450 4000 5000 2,750 2,750 3,250 3,450 4000 5000
Face Area Sq. Ft. 9.15 12.58 15.72 23.58 18.0 22.5 9.15 12.58 15.72 23.58 18.0 22.5
Coil Rows Deep 1 1 1 1 2 2 1 1 1 1 2 2
Fin / Inches 18 18 18 18 16 16 18 18 18 18 16 16
Liquid Line OD 3/8 3/8 3/8 3/8 1/2 1/2 3/8 3/8 3/8 3/8 1/2 1/2
Vapor Line OD 3/4 3/4 7/8 7/8 1-1/8 1-1/8 3/4 3/4 7/8 7/8 1-1/8 1-1/8
Unit Charge (Lbs. - Oz.) 4 3 - 15 5-4 7-5 9-7 12-3 15-3 3 - 15 5-4 7-5 9-7 12-3 15-3
4 .68 .68 .70 .70 1.26 1.26 .68 .68 .70 .70 1.26 1.26
Charge Per Foot, Oz.
Operating Weight Lbs. 170 176 206 228 219 368 170 176 206 228 219 368
1. Rated in accordance with ARI Standard 110, utilization range “A”.
2. Dual element fuses or HACR circuit breaker.
3. All scrolls listed with a superscript “B” are Bristol scrolls. All scrolls listed with a superscript “C” are Copeland scrolls.
4. The Unit Charge is correct for the outdoor unit, matched indoor coil and 15 feet of refrigerant tubing. For tubing lengths other than
15 feet, add or subtract the amount of refrigerant, using the difference in length multiplied by the per foot valve.
Additional R-22 Charge / Orifice Size for Various Matched Systems - 1 PHASE
ADDITIONAL R-22 CHARGE / ORIFICE SIZE FOR VARIOUS MATCHED SYSTEMS
Outdoor Unit H1RA018S06 H1RA024S06 H2RA030S06 H2RA036S06 H1RA042S06 H1RA048S06 H3RA060S06
Unit Orifice (s) 1 51,53,55 59,61,63 67 71,73,75 75,78,81 78,81,84,87 96
Factory R-22 Charge, lbs-oz 3-6 3 - 11 3 - 14 3 - 15 5-4 7-5 6-2
1. These orifices are packed in the customer packet of each outdoor unit.
2. These orifices are factory mounted in the flow control device of each indoor coil.
3. Systems matched with furnaces or air handlers not equipped with blower-off delays, may require blower Time Delay Kit #6918A5011.
PROCEDURES:
1. Unit factory charge listed on the unit nameplate includes refrigerant for the condenser, the smallest evaportor and for 15 feet of interconnecting line
tubing.
2. Verify the orifice size and additional charge required for specific evaportor coil in the system using the above table.
3. Additional charge for the amount of interconnecting line tubing greater than 15 feet at the rate specified in the table above.
4. Permanently mark the unit nameplate with the total system charge. Total System Charge = Base Charge (as shipped) + adder for
evaportor + adder for line set.
5. If the orifice in the evaportor was changed, verify the evaportor nameplate has been marked with the correct orifice size.
1. These orifices are packed in the instruction/warranty packet of each outdoor unit.
2. These orifices are factory mounted in the flow control device of each indoor coil.
3. The TXV is factory mounted in the coil or air handler.
PROCEDURES:
1. Unit factory charge listed on the unit nameplate includes refrigerant for the condenser, the smallest evaportor and for 15 feet of interconnecting line
tubing.
2. Verify the orifice size and additional charge required for specific evaportor coil in the system using the above table.
3. Additional charge for the amount of interconnecting line tubing greater than 15 feet at the rate specified in the table above.
4. Permanently mark the unit nameplate with the total system charge. Total System Charge = Base Charge (as shipped) + adder for
evaportor + adder for line set.
5. If the orifice in the evaportor was changed, verify the evaportor nameplate has been marked with the correct orifice size.
1. G2FD coils available with a factory installed horizontal drain pan. See price pages for specific model number.
2. Single phase units require single phase 2HK heaters. Three phase units require three phase 2HK heaters.
3. TXV = Use 1TV700 Series Kit.
4. To meet R=4.2 insulation requirements, substitute F2FP for F2RP, and F2FC for F2RC. models. All ratings remain the same.
5. FG8, FG9, and FL8 furnaces and F2RP / F2RC air handlers have B.O.D (Blower on Delay) standard.
6. H*BA-(T,W)090 is field convertible to two stage operation. Its IPLV = 11.2.
— = Not Applicable.
COOLING PERFORMANCE
SUCT. T/P AIR TEMP ON CONDENSER SUCT. T/P AIR TEMP ON CONDENSER
MODEL @ COMPR. 75°F 95°F 115°F MODEL @ COMPR. 75°F 95°F 115°F
TEMP. PSIG MBH KW MBH KW MBH KW TEMP. PSIG MBH KW MBH KW MBH KW
35 61.5 16.2 1.66 13.1 1.84 11.0 1.96 35 61.5 39.9 4.18 32.3 4.63 27.0 4.94
40 68.5 17.7 1.67 14.9 1.88 12.8 2.04 H1RA048S06 40 68.5 43.6 4.21 36.7 4.73 31.4 5.14
H1RA018S06
45 76.0 19.3 169 16.7 1.92 14.2 2.11 H1RA048S(25,46) 45 76.0 47.6 4.26 41.1 4.84 34.9 5.32
50 84.0 20.8 1.70 18.5 1.96 15.9 2.18 50 84.0 51.1 4.28 45.5 4.94 39.0 5.48
35 61.5 21.0 2.23 17.0 2.46 14.2 2.63 35 61.5 49.4 4.15 43.8 5.13 38.2 6.34
40 68.5 22.9 2.24 19.3 2.52 16.5 2.74 40 68.5 54.0 4.19 48.2 5.14 42.3 6.35
H1RA024S06 H3RA060S06
45 76.0 25.0 2.27 21.6 2.58 18.3 2.83 45 76.0 58.4 4.27 52.4 5.25 46.3 6.47
50 84.0 26.8 2.28 23.9 2.63 20.5 2.92 50 84.0 62.7 4.32 56.9 5.38 50.2 5.61
35 61.5 25.1 2.68 20.3 2.97 17.0 3.17 35 61.5 54.4 4.46 50.5 4.74 46.3 5.08
40 68.5 27.4 2.70 23.1 3.04 19.7 3.30 40 68.5 60.1 4.44 56.0 4.83 51.6 5.18
H2RA030S06 H1RA060S(25,46)
45 76.0 29.9 2.74 25.8 3.10 21.9 3.41 45 76.0 65.8 4.53 61.6 4.92 56.9 5.26
50 84.0 32.1 2.75 28.6 3.17 24.5 3.51 50 84.0 71.9 4.62 67.5 5.01 62.6 5.36
35 61.5 30.5 3.28 24.7 3.64 20.6 3.88 35 61.5 77.4 5.06 63.4 6.08 50.6 7.35
H2RA036S06 40 68.5 33.3 3.31 28.1 3.72 24.0 4.04 40 68.5 84.5 5.21 69.2 6.23 55.4 7.49
H1RA076S(25,46)
H1RA036 S(25,46) 45 76.0 36.4 3.35 31.4 3.80 26.7 4.18 45 76.0 91.8 5.37 75.3 6.38 60.3 7.64
50 84.0 39.1 3.36 34.8 3.88 29.9 4.31 50 84.0 99.4 5.54 81.7 6.55 65.6 7.80
35 61.5 35.8 3.83 28.9 4.25 24.2 4.53 35 61.5 84.0 8.28 72.9 9.11 61.7 9.87
H1RA042S06 40 68.5 39.1 3.86 32.9 4.34 28.2 4.72 40 68.5 92.5 8.50 80.8 9.41 68.9 10.26
H1RA090S(25,46)
H1RA042S(25,46) 45 76.0 42.6 3.90 36.8 4.53 31.3 4.87 45 76.0 101.3 8.73 89.0 9.72 76.5 10.66
50 84.0 45.8 3.93 40.8 4.63 35.0 5.03 50 84.0 110.4 8.95 97.5 10.03 84.4 11.08
NOTES:
1. For condensing unit only. Does not include effect of evaporator motor power or heat.
2. Performance based on 15° superheat and 15° sub-cooling at condensing unit.
a. Increase capacity 1% for each 2° increase in sub-cooling.
b. Decrease capacity 1% for each 2° decrease in sub-cooling.
3. Sub-cooling in excess of 20° may result in excessively high condensing temperature with air on condenser above 115°F.
Maximum recommended condensing temperature is 140°F.
DIMENSIONS - 1 Phase
REFRIGERANT
C UNIT DIMENSIONS
CONNECTION
MODEL (INCHES)
LINE SIZE
A1 B C Liquid Vapor
018 17 35 23 5/8”*
A
024 17 35 23 5/8”*
030 19 35 23 3/4”
036 19 35 23 3/8” 3/4”
042 25 35 23 3/4”
048 27 37 27 7/8”
B
060 27 37 27 7/8”
1. Including Fan guard.
* Reducer Required.
DIMENSIONS - 3 Phase
REFRIGERANT
UNIT DIMENSIONS
CONNECTION
MODEL (INCHES)
LINE SIZE
A1 B C Liquid Vapor
036 19 35 23 3/8” 3/4
042 25 35 23 3/8 3/4
048 27 37 27 3/8” 7/8
060 39 37 27 3/8” 7/8
076 26 43 32 1/2 1-1/8
090 32 43 32 1/2 1-1/8
1. Including Fan guard.
* Reducer Required.
TYPICAL INSTALLATION
10” CLEARANCE
COIL AREA TO INDOOR COIL
ALL FIELD WIRING TO BE IN ACCORDANCE WITH ELECTRIC CODE (NEC) AND/OR LOCAL CODES
POWER WIRING
208/230-1-60 24 VOLT CONTROL WIRING POWER WIRING
230-1-50 MINIMUM 18 GA. WIRE CONTROL WIRING
(NEC CLASS 2) FACTORY WIRING
CONTACTOR
TERMINALS
GND.
LUG COIL *
Y R G W
ALL FIELD WIRING TO BE IN ACCORDANCE WITH ELECTRIC CODE (NEC) AND/OR LOCAL CODES
1 Phase 3 Phase
Air Handler Coil T.C. S.C. KW Air Handler Coil T.C. S.C. KW
N1AHB1206 G2FD036(S,H)17 1.01 1.00 1.00 N1AHB1246 G2FD036(S,H)17 1.00 1.00 0.98
N1AHB1206 G2FD046(S,H)17 1.02 1.02 1.00 N1AHB1246 G2FD046(S,H)21 1.02 1.02 1.00
F2RC/F2FC036 1.00 0.86 1.00 F2RC/F2FC036 1.00 0.86 1.00
F2RP/F2FP036 1.02 1.01 1.00 G1FA048S21 1.07 1.07 1.04
F2RP/F2FP042 1.02 1.01 1.01 G1NA036S17J 1.02 1.02 1.01
G1FA036S14 1.00 1.00 1.00 G1NA036S21C 1.02 1.02 1.00
G1FA048S17 1.04 1.04 1.01 G1UA036S17,21 1.00 1.00 1.00
G1FA048S21 1.07 1.07 1.04 G1UA048S21 1.07 1.07 1.04
G1HD036 1.02 1.02 1.05 G2FD036(S,H)17 1.01 1.00 1.00
G2FD046(S,H)17 1.02 1.02 1.00 G2FD036(S,H)21 1.01 1.00 1.00
G1HD048 1.04 1.04 1.05
G1NA036S17J 1.02 1.02 1.01
G1NA036S21C 1.02 1.02 1.00
G1UA036S14 1.00 1.00 1.00
G1UA036S17,21 1.00 1.00 1.00
G1UA048S17 1.04 1.04 1.01
G1UA048S21 1.07 1.07 1.04
G2FD035(S,H)14 0.99 0.99 0.99
G2FD036(S,H)17 1.01 1.00 1.00
G2FD036(S,H)21 1.01 1.00 1.00
G2FD042(S,H)21 1.02 1.02 1.00
1 Phase 3 Phase
Air Handler Coil T.C. S.C. KW Air Handler Coil T.C. S.C. KW
N1AHC1606 G2FD042(S,H)21 0.96 0.96 0.99 N1AHC1646 G2FD042(S,H)21 0.98 0.99 1.00
N1AHC1606 G2FD048(S,H)21 1.00 1.00 1.01 N1AHC1646 G2FD048(S,H)21 0.99 1.01 1.01
F2RP/F2FP042 0.96 0.95 0.99 F2RP/F2FP042 0.95 0.95 0.99
F2FP048 0.99 0.99 0.99 F2FP048 0.99 0.99 0.99
G1FA048S17 0.98 1.00 1.00 G1FA060S21,24 1.02 1.02 1.00
G1FA060S21,24 1.02 1.02 1.00 G1NA036S21C 0.98 0.93 0.99
G1HD048 0.99 0.99 1.01 G1NA048S21D 0.99 0.94 1.00
G1NA036S21C 0.98 0.93 0.99 G1UA048S21 1.00 1.00 1.00
G1NA048S21D 0.99 0.94 1.00 G1UA060S21,24 1.02 1.03 1.00
G1UA048S17 0.98 1.00 1.00 G2FD042(S,H)21 0.96 0.96 0.99
G1UA048S21 1.00 1.00 1.00 G2FD046(S,H)17 0.98 0.98 1.00
G1UA060S21,24 1.02 1.03 1.00 G2FD048(S,H)21,24 1.00 1.00 1.01
G2FD042(S,H)21 0.96 0.96 0.99
G2FD046(S,H)17 0.98 0.98 1.00
G2FD048(S,H)21,24 1.00 1.00 1.01
G2FD060(S,H)24 1.02 1.02 1.00
1 Phase 3 Phase
Air Handler Coil T.C. S.C. KW Air Handler Coil T.C. S.C. KW
N1AHC1606 G2FD048(S,H)21 1.01 1.01 1.01 N1AHC1646 G2FD048(S,H)21 1.01 1.01 1.00
N1AHD2006 G2FD060(S,H)24 1.03 1.03 1.01 N1AHD2046 G2FD048(S,H)24 1.01 1.01 1.00
F2FP048 1.00 1.00 1.03 N1AHD2046 G2FD060(S,H)24 1.03 1.03 1.00
F2FP060 1.02 1.02 1.00 F2FP048 1.00 1.00 1.03
G1FA048S17 0.98 0.99 1.01 G1FA048S21 1.00 1.00 1.00
G1FA060S21,24 1.03 1.03 1.01 G1NA048S21D 1.02 1.02 1.02
G1HD048 1.00 1.00 0.99 G1UA048S21 1.00 1.00 1.00
G1HD060 1.02 1.02 1.00 G2FD048(S,H)21,24 1.01 1.01 1.01
G1UA G1NA
1/2 CASED G1HD UNCASED
UPFLOW HORIZONTAL DUCT UPFLOW
G2FD*
MULTI-POSITION
G1FA
(UPFLOW, HORIZONTAL
FULL CASED G2FD090 is upflow only.
AND DOWNFLOW)
UPFLOW
N1AH OR N1VS
MODULAR BLOWER
(UPFLOW, HORIZONTAL
AND DOWNFLOW)
LIGHT COMMERCIAL
APPLICATIONS F2RC / F2FC OR
F2RC / F2FP
G2FD FAN COIL UNITS
COIL (UPFLOW, HORIZONTAL)
NOTES