Lab 2: Motion 1 + 2
Lab 2: Motion 1 + 2
Lab 2: Motion 1 + 2
1 Introduction
This experiment serves multiple purposes:
• It serves to demonstrate that one way of doing a rough check of your measurement
device is to measure something of which you have a rough idea of the true value. Also,
measuring something that is precisely known provides a calibration of the device.
• This laboratory will give you some practice in propagation of errors and statistical
analysis of random uncertainties.
• This lab will introduce you to the DataStudio software system and PASCO hardware
that will be used in a number of experiments conducted this semester.
2 Theory
The velocity v is defined as v = dx/dt and acceleration a as a = dv/dt = d2 x/dt2 . Integrating
the last definition twice for a situation where a is constant gives
v = v0 + at and (1)
x = x0 + v0 t + 21 at2 , (2)
where the constants x0 and v0 are the position and velocity when t = 0. When these are
plotted, time is usually chosen as the horizontal axis, with position and velocity as the
vertical axes. The first equation is then a straight line and the second a parabola.
3 Equipment Used
Equipment List: An air track, 2 gliders, 2 wooden blocks, a meter stick, a motion sensor,
and hardware for mounting the motion sensor on the lab bench.
1
PHYS-UA 71 Introduction to Experimental Physics I Lab 2: Motion 1 + 2
Air Tracks & Gliders: In this experiment you will be using an air track, a long straight
metal beam of triangular cross section with many small holes in it. A blower pumps
air through the holes so that a glider placed on top of the air track floats on a cushion
of air with little friction. The blower sits on the floor and has a switch on the top. The
blowers are noisy and run hot. Run them only when you need them!
Please handle the gliders carefully. They are expensive, and if dropped or abused, may
be damaged. Do not move the gliders on the air track without the blower on, as this
damages both the glider and air track. A motion sensor, which works by detecting
reflected sonic (sound) pulses from an index card attached to the glider, can be used
to detect the glider’s position. Fix the index card on top of the glider and orient it
perpendicular to the track to reflect the sonic pulses.
The Motion Sensor: The motion sensor works by measuring the time of flight of sound
pulses from the motion sensor to the glider and back. Like all waves, sound can be
reflected (producing an echo). In this experiment, the motion sensor emits a short
sound pulse, say at time t1 , that travels out in a cone at a speed vs towards the glider.
The pulse is reflected by the index card on the glider and returns to the motion detector
where its arrival time t1a is detected. The time of flight ∆t1 = t1a − t1 is related to the
distance between the position detector and the position of the index card on the glider
by the relation
1
x1 = vs ∆t1 (3)
2
Obtaining the correct distance x1 thus depends on knowing the speed of sound in air.
Sound is a pressure wave whose speed depends on the properties of√the gas in which it
propagates. For a given gas the speed of sound is proportional to T , where T is the
absolute temperature. For air at 20◦ C (= 293 K) the speed is 344 m/s.
In order to measure the position of the glider as a function of time, the motion sensor
emits a train of equally-spaced sound pulses at regular intervals, that is, at times
t1 , t2 , t3 , .... The number of pulses emitted per unit time is called the sample rate, and
can be varied from 1 to 250 Hz. The default sample rate is 10 Hz, which means that 10
pulses per second are emitted. The pulses are ultrasonic (pressure variations that are
too fast to be heard) but you can hear a click when each pulse is emitted. The motion
sensor detects the reflected pulses at times t1a , t2a , t3a , ... and measures the time of flight
∆ti = tia − ti between the emission and reflection of a given pulse. The DataStudio
digital display can be programmed to show the time of flight of the pulses. It can also
show the distance xi = vs ∆ti /2 of the glider from the motion sensor, as well as the
glider’s velocity and acceleration. Note, however, that only the time-of-flight ∆ti is
measured; the other quantities are calculated by the DataStudio software. You will use
these derived quantities in the lab, to get a sense of what is going on. However, you will
not rely solely on these derived quantities when you analyze the data for your report.
In the last part of the experiment, you will determine the velocities and accelerations
for yourself from the position vs time data that are directly measured.
2
PHYS-UA 71 Introduction to Experimental Physics I Lab 2: Motion 1 + 2
The motion sensor has two plugs. The yellow plug delivers electrical pulses that gen-
erate the sound pulses; it is inserted into Channel 1 of the DataStudio interface. The
black plug carries the signal generated by the echo; it is inserted into channel 2 of the
interface. The maximum distance that can be measured depends on the sample rate.
Some of the motion sensors have a switch that allows you to choose between a pulse
emitted in a narrow or somewhat broader cone. Choose the switch position that gives
the best results.
5.2 Programming
Launch the DataStudio software by double clicking on the DataStudio icon on the desktop of
your lab computer. Once the DataStudio window is open it should display a diagram of the
750 Interface in the box titled Experiment Setup. If not, click Create Experiment, then click
Setup and select the 750 interface. Plug the Motion Sensor into the 750 Interface channel 1
(gold) + 2 (black). Next, program DataStudio for the motion sensor: click on digital channel
3
PHYS-UA 71 Introduction to Experimental Physics I Lab 2: Motion 1 + 2
1 on the 750 interface diagram and an Add Sensor window will pop up. Scroll and select
Motion Sensor.
The motion sensor is calibrated by measuring a known distance and telling it what the
right answer is. Click the Motion Sensor tab in the Experiment Setup window to access the
calibration window. You see “Standard Distance”, which is the known distance at which
you can place an object (use a notebook) and “Present Sensor Distance” which is what the
sensor reads. The default standard distance is 1 m. You may vary this if you wish - should
you? When you are ready to calibrate, press the Set Sensor Distance = Standard Distance
button. This sets the calibration factor so that the sensor reads the standard distance when
an object is in the same position as the one the sensor currently detects.
In the experiment setup window the default sample rate of 10 Hz is shown. Change the
sample rate to 100 Hz and observe the message dialog window that pops up. Next increase
the sample rate to 200 Hz and again observe what the maximum distance the motion sensor
can measure. Can you think of why the maximum distance depends on the sample rate? Set
the sample rate to 20 Hz and click OK.
Note that a motion sensor icon is now below channels 1 and 2. Open a digits display by
dragging the Digits display icon in the Display window onto the motion sensor icon. A box
opens showing position and m (for meters). No numbers will be displayed in this box until
you press start (later in these instructions).
Click on top of the digits display window to try the following.
• See if you can enlarge the digits display window by dragging an edge or a corner. You
should be able to enlarge the display and this will be useful.
• In order to add different digits displays to the same window, click and drag “Digits 1”
in the Display window to the other measurements in the Data window. First try adding
a Velocity Digits display by dragging it to where it says Velocity, Ch 1&2. Repeat for
other items in the Data Menu and when you’re done, close all displays except Position
by right clicking on the display and selecting Remove Selected Data.
• To add time to the Data window, click “Motion Time” to on in the “Measurements”
tab of the Experiment Setup window.
4
PHYS-UA 71 Introduction to Experimental Physics I Lab 2: Motion 1 + 2
window and examine the digits display and position of the notebook on the meter stick while
you move the notebook in the acoustic beam of the sensor. You should see that the number
displayed on the digital display corresponds approximately to the position on the meter stick
where you are holding the notebook or card. Click the STOP button when finished. Run # 1
appears in the data box. The digits display shows the last value measured.
Is the number of digits to the right of the decimal point is sufficient? If not, increase
the number to a reasonable value (Drag the right side of the window enough to the right so
that all digits are displayed and then click the arrow of the 3.14 button in the box and select
Increase Precision until it is at the desired precision) and justify that value. Take another
run and see how close you can get the notebook to the sensor and get reliable values.
Try deleting Run # 1 by clicking on it anywhere in the Data box and then pressing the
delete key. Don’t let too many runs accumulate.
5
PHYS-UA 71 Introduction to Experimental Physics I Lab 2: Motion 1 + 2
1. In the first part of this procedure you performed a calibration of the motion sensor.
The calibration sets the conversion factor from time to distance, which is just the speed
of sound. Why might the speed of sound vary from day to day or lab bench to lab
bench?
3. The maximum measurable distance depends on sample rate. Assuming that the system
cannot deal with a second pulse emitted before the first reflected one is detected,
estimate the maximum sample rate for a 1m distance.
5. You checked the DataStudio measurement by comparing distances of 0.6 and 0.7 meters
with the value calculated by DataStudio.
(a) List the sources of error in your measurement of 0.6 and 0.7 m and estimate the
uncertainty in these measurements.
(b) List the sources of error in the DataStudio measurement of 0.6 and 0.7 m and
estimate the uncertainty in these measurements.
(c) Are the two measurements consistent within these errors?
6. Calculate the speed of sound using your distance measurements and the DataStudio
times. Is the result reasonable?
6
PHYS-UA 71 Introduction to Experimental Physics I Lab 2: Motion 1 + 2
axes brings up a menu that allows you to adjust the plotting limits. You may wish to take
advantage of this feature to adjust the plot so that it covers more of the available space.
Determine the slope of the graph line as follows. Click the smart tool button near the
top of the Position versus Time Match Graph Window. A smart cursor will open on the graph.
Left click and drag the smart cursor and observe that the coordinates of the cursor appears
with the crosshairs. Determine the coordinates of the two break points in the graph and
calculate the slope. Click the smart button tool to remove the smart cursor.
Taking data Now you will try to replicate the graph by moving a notebook in front of the
sensor. This will be easier if you first examine the graph and answer the following questions.
1. How close should your notebook be to the motion sensor at the beginning?
Examine the graph before you take data and predict what your motion should be. Press
the START button to begin recording data, and press the stop button to end the recording.
The motion sensor will make a quiet clicking noise when it is on. Was your prediction a good
one? Do more trials and try to improve your accuracy. To print out a copy of a graph for
your report, put your bench number or name in the legend title. To label your graph right
click on the graph and select Settings. Click upon the Legend tab and type in the Legend
Title either your bench number, or name, or some other unique form of identification. Make
sure you check Show Legend Title and click OK. To print, click File, Print, and OK.
6.1.1 Summary of Questions to Answer and Analysis to be Submitted for Ex-
periment P01
Analysis
1. Use the cursor to click-and-draw a rectangle around the middle section of your plot.
Right click on the graph and select slope. Click the Statistics button and then click
the Scale to fit button to resize the graph to fit the data.
2. Click the Fit Menu button on the top bar of the Graph. Select Linear Fit. The slope
of this part of the position vs time plot is the velocity during the selected region of
motion.
Questions
1. In the graph, what is the slope of the line of best fit for the middle section of your
plot?
7
PHYS-UA 71 Introduction to Experimental Physics I Lab 2: Motion 1 + 2
1. In what direction should your notebook initially move and how far should in move it
that direction before changing directions?
2. How far should your notebook move in the opposite direction before changing directions
again?
3. At what time (or times) should your notebook be farthest from its starting point? How
far should it have moved at that time (or times)?
4. How far should your notebook have moved from its initial position at the end of the
run (10 seconds)?
5. With respect to the motion of the notebook, does it matter how far you are from
the motion sensor when you take the data, assuming that you are always within the
operating range of the sensor? Discuss.
8
PHYS-UA 71 Introduction to Experimental Physics I Lab 2: Motion 1 + 2
window. Now drag the ”graph 1” icon to velocity and do the same for acceleration. Place
the motion sensor near the spring bumper at the high end of the air track so that the grill
looks down the track. The motion sensor does not work for less than 0.4 m, so place an
object under the air track 0.4 m from the sensor and start your gliders from that point. Turn
on the blower, place the smaller glider on the track, and release the glider and click Start
at the same time. Click Stop just before the glider hits the end of the air track. Make a
number of runs, making small adjustments in the orientation of the sensor until you get the
best data you can. You will probably find that if the sensor points slightly up the data will
be best.
7.1.1 Questions and Analyses to be Submitted for Part 3
1. For your best run, click the scale to fit button (located on the top left of the graph
window) and examine the three graphs in the display and discuss them. Are they what
you expect and what is predicted by the theory? By inspection, are the graphs related,
and if so, how?
2. Is it reasonable that the velocity curve is noisier than the position curve, and the
acceleration curve noisier than the velocity curve? Explain.
3. Click the statistics button and then the scale to fit button. For the position plot
choose fit and then power fit. For the velocity plot choose fit and then linear fit. In
the statistics window, y refers to the vertical axis and x to the horizontal axis. If your
data points are noisy near the ends, draw boxes to exclude the noisy data but include
as much good data as possible. Draw the boxes so that they all begin and end at the
same times. Your boxes should be lined up vertically.
5. In the acceleration plot the average acceleration for the data in the box is given by the
mean of y. Compare this to m. Compare these values to the theoretical one.
6. For the position plot, the notation n(Power) means that the function is raised to a
certain exponent. What is the n(power)? What does the theory say it should be?
7. Once you have data that you are satisfied with, you should save it to an Excel file. To
do so, you first need to make a table of your data by dragging the Table icon over to
position in the data window. Next, drag “Table 1” to velocity and after to acceleration.
You should see a table window that has position, velocity, and acceleration. Then you
can save the data by selecting the Export Data button under the File menu. It will
ask you to select either the position, velocity, or acceleration data. Select the position
data and save it to a text file with a descriptive name, say position.txt. Repeat this
for the velocity and acceleration data. When you are done, you should have three files:
position.txt, veloctiy.txt, acceleration.txt. E-mail the data files to yourself
and to your lab mates so that you have multiple copies for later use.
During the laboratory session, make sure to complete the section on mass
and angle dependence that follows the post-lab activity below.
9
PHYS-UA 71 Introduction to Experimental Physics I Lab 2: Motion 1 + 2
2. Consider a sitation (like the one in this experiment) where position is measured at
fixed time intervals ∆t. Show that the velocity at time i can be approximated in terms
of positions at neighboring times as
xi+1 − xi−1
vi = (4)
2∆t
Show that the acceleration can be approximated from three points using
xi+1 − 2xi + xi−1
ai = (5)
(∆t)2
Hints: Make sure to think about whether you are determining each quantity’s value
at a time ti of a measurement or at a time half way between two measurements. Why
are these equations only approximate for ∆t > 0?
3. Modify your program to calculate the velocity and acceleration as a function of time by
using the previous two equations. Graphically compare your results to the velocities
and accelerations given by the DataStudio software. You should find that the velocities
and accelerations you obtain are noisier than those given by the DataStudio software,
especially the acceleration data. In fact, a lot of noise has been filtered out of the
DataStudio data using some algorithm that we can only hope is valid. If you want to
know more about how this is done, consult your instructor.
4. Note that no matter how the data is processed, the velocity and acceleration data are
noisier than the original position data. Why? Hint: When two quantities, say a and
b are known to a finite number of digits (for example, 8), what happens to the number
of significant digits of c = a − b if a and b are very near each other?
5. Based on your responses above, is it better to use a slow or fast sample rate in this
experiment? What are the advantages and disadvantages of using fast or slow sample
rates?
10
PHYS-UA 71 Introduction to Experimental Physics I Lab 2: Motion 1 + 2
7. Using a python program to calculate the standard deviation of the values of a, estimate
the uncertainties in a. How does this result compare with the one you obtained from
propagation of errors?
1. Compare and discuss your results for different mass and angle.
8 Finishing Up
Please leave your lab bench as you found it. Thank you.
11