Technical Data Sheet

Approved 36842;36843 1 36842 zinc ethyl silicate ^(ValidationDate) 1

Jotatemp 540 Zinc

Product description
This is a two component glass flake reinforced inorganic zinc ethyl silicate coating. It conforms to the
compositional requirements of SSPC paint 20, level 3. It provides corrosion protection as a single coat and can
be used under insulation if overcoated with a high temperature coating designed to offer protection against CUI.
It is heat resistant up to 540 °C (1004 °F). Suitable for properly prepared carbon steel substrates only. This
product complies with ASTM D520 type II zinc dust.

Typical use
Protective:
Suitable for process and piping equipment that will be exposed to elevated temperatures. Can be used at
ambient temperatures, provided it is used as a primer in a suitable coating system. Specially designed as a
primer in coating systems where extended durability at high temperature is required.
Other

Colours
bluish grey

Product data
Property Test/Standard Description

Solids by volume OCCA Monograph No. 4 80 ± 2 %


Gloss level (GU 60 °) ISO 2813 matt (0-35)
Flash point ISO 3679 Method 1 19 °C
Density calculated 2 kg/l
VOC-US/Hong Kong US EPA method 24 (tested) 358 g/l
(CARB(SCM)2007, SCAQMD rule 1113, Hong Kong)
VOC-EU IED (2010/75/EU) (theoretical) 467 g/l

The provided data is typical for factory produced products, subject to slight variation depending on colour.
All data is valid for mixed paint.
Gloss description: According to Jotun Performance Coatings' definition.

Film thickness per coat


Typical recommended specification range

Dry film thickness 75 - 170 μm


Wet film thickness 95 - 215 μm
Theoretical spreading rate 10.7 - 4.7 m²/l

Date of issue: 18 June 2018 Page: 1/5

This Technical Data Sheet supersedes those previously issued.


The Technical Data Sheet (TDS) is recommended to be read in conjunction with the Safety Data Sheet (SDS) and the
Application Guide (AG) for this product. For your nearest local Jotun office, please visit our website at www.jotun.com
Technical Data Sheet
Jotatemp 540 Zinc

Surface preparation
To secure lasting adhesion to the subsequent product all surfaces shall be clean, dry and free from any
contamination.

Surface preparation summary table

Surface preparation

Substrate Minimum Recommended

Carbon steel Sa 2½ (ISO 8501-1) with a surface Sa 2½ (ISO 8501-1) with a surface
profile Fine to Medium G (ISO 8503-2) profile Fine to Medium G (ISO 8503-2)

Application
Application methods
The product can be applied by

Spray: Use air spray or airless spray.


Brush: Recommended for stripe coating and small areas. Care must be taken to achieve the
specified dry film thickness. In order to avoid settling of heavy zinc, continuous
mechanical stirring during application might be necessary.

Product mixing ratio (by volume)

Jotatemp 540 Zinc Comp A 8 part(s)


Jotatemp 540 Zinc Comp B 1.32 part(s)

Component A is a liquid and Component B is dry zinc dust. Component A must be well shaken before use. Pour
the zinc dust slowly into the liquid during mechanical mixing. Stir until lump free and pass through a 60 mesh
sieve.

Thinner/Cleaning solvent
Thinner: Jotun Thinner No. 4 / Jotun Thinner No. 25

Thinning max.: 5 %

Jotun Thinner No. 4: for fast evaporation


Jotun Thinner No. 25: for slow evaporation

Guiding data for airless spray


Nozzle tip (inch/1000): 17-21

Pressure at nozzle (minimum): 100 bar/1400 psi

Date of issue: 18 June 2018 Page: 2/5

This Technical Data Sheet supersedes those previously issued.


The Technical Data Sheet (TDS) is recommended to be read in conjunction with the Safety Data Sheet (SDS) and the
Application Guide (AG) for this product. For your nearest local Jotun office, please visit our website at www.jotun.com
Technical Data Sheet
Jotatemp 540 Zinc

Drying and Curing time


Substrate temperature 5 °C 10 °C 23 °C 40 °C

Surface (touch) dry 1h 30 min 15 min 10 min


Walk-on-dry 1.5 h 45 min 30 min 25 min
Dry to over coat, minimum 15 h 10 h 3h 1h
Dried/cured for service 15 h 10 h 3h 1h

For maximum overcoating intervals, refer to the Application Guide (AG) for this product.

The given drying and curing times, as well as over coating intervals for inorganic zinc ethyl silicates are
measured at relative humidity (RH) 80 % during application and curing. An even higher RH will increase the
curing speed. The paint requires continuous RH above 50 % to cure.

Surface (touch) dry: The state of drying when slight pressure with a finger does not leave an imprint or reveal
tackiness.

Walk-on-dry: Minimum time before the coating can tolerate normal foot traffic without permanent marks,
imprints or other physical damage.

Dry to over coat, minimum: The recommended shortest time before the next coat can be applied.

Dried/cured for service: Minimum time before the coating can be permanently exposed to the intended
environment/medium.

Induction time and Pot life


Paint temperature 23 °C

Pot life 8h

Heat resistance
Temperature
Continuous Peak
Dry, atmospheric 540 °C 600 °C

This product can withstand a peak temperature of 600 °C (1112 °F). A continuous temperature above 540 °C
will however affect the corrosion protection of the coating. Note that at higher temperatures a suitable topcoat
will extend the life of the coating.

Peak temperature duration max. 1 hour.


The temperatures listed relate to retention of protective properties. Aesthetic properties may suffer at these
temperatures.

Date of issue: 18 June 2018 Page: 3/5

This Technical Data Sheet supersedes those previously issued.


The Technical Data Sheet (TDS) is recommended to be read in conjunction with the Safety Data Sheet (SDS) and the
Application Guide (AG) for this product. For your nearest local Jotun office, please visit our website at www.jotun.com
Technical Data Sheet
Jotatemp 540 Zinc

Product compatibility
Depending on the actual exposure of the coating system, various primers and topcoats can be used in
combination with this product. Some examples are shown below. Contact Jotun for specific system
recommendation.
Subsequent coat: epoxy, silicone acrylic, titanium catalysed inorganic ceramic copolymer

Packaging (typical)
Volume Size of containers
(litres) (litres)

Jotatemp 540 Zinc Comp A 8 10


Jotatemp 540 Zinc Comp B 1.32 20

The volume stated is for factory made colours. Note that local variants in pack size and filled volumes can vary
due to local regulations.

Storage
The product must be stored in accordance with national regulations. Keep the containers in a dry, cool, well
ventilated space and away from sources of heat and ignition. Containers must be kept tightly closed. Handle
with care.

Shelf life at 23 °C
Jotatemp 540 Zinc Comp A 12 month(s)
Jotatemp 540 Zinc Comp B 48 month(s)

In some markets commercial shelf life can be dictated shorter by local legislation. The above is minimum shelf
life, thereafter the paint quality is subject to re-inspection.

Caution
This product is for professional use only. The applicators and operators shall be trained, experienced and have
the capability and equipment to mix/stir and apply the coatings correctly and according to Jotun's technical
documentation. Applicators and operators shall use appropriate personal protection equipment when using this
product. This guideline is given based on the current knowledge of the product. Any suggested deviation to suit
the site conditions shall be forwarded to the responsible Jotun representative for approval before commencing
the work.

Health and safety


Please observe the precautionary notices displayed on the container. Use under well ventilated conditions. Do
not inhale spray mist. Avoid skin contact. Spillage on the skin should immediately be removed with suitable
cleanser, soap and water. Eyes should be well flushed with water and medical attention sought immediately.

Colour variation

Date of issue: 18 June 2018 Page: 4/5

This Technical Data Sheet supersedes those previously issued.


The Technical Data Sheet (TDS) is recommended to be read in conjunction with the Safety Data Sheet (SDS) and the
Application Guide (AG) for this product. For your nearest local Jotun office, please visit our website at www.jotun.com
Technical Data Sheet
Jotatemp 540 Zinc

When applicable, products primarily meant for use as primers or antifoulings may have slight colour variations
from batch to batch. Such products may fade and chalk when exposed to sunlight and weathering.

Disclaimer
The information in this document is given to the best of Jotun's knowledge, based on laboratory testing and
practical experience. Jotun's products are considered as semi-finished goods and as such, products are often
used under conditions beyond Jotun's control. Jotun cannot guarantee anything but the quality of the product
itself. Minor product variations may be implemented in order to comply with local requirements. Jotun reserves
the right to change the given data without further notice.

Users should always consult Jotun for specific guidance on the general suitability of this product for their needs
and specific application practices.

If there is any inconsistency between different language issues of this document, the English (United Kingdom)
version will prevail.

Date of issue: 18 June 2018 Page: 5/5

This Technical Data Sheet supersedes those previously issued.


The Technical Data Sheet (TDS) is recommended to be read in conjunction with the Safety Data Sheet (SDS) and the
Application Guide (AG) for this product. For your nearest local Jotun office, please visit our website at www.jotun.com