Installation of Padeyes Ad Load Test: Front Cover
Installation of Padeyes Ad Load Test: Front Cover
Installation of Padeyes Ad Load Test: Front Cover
5002
F-OPE-067 Rev.3
CONTENTS Página 1 de 1
Client :
Load Test
4. Padeye
5. Personnel Qualification
6. Equipment Calibration
PREPARED BY: G Mitchell REVIEWED BY: Marcelo Maia APPROVED BY: James Miller
POSITION: Project Supervisor POSITION: Report Analyst POSITION: Operations
F-OPE-068 Rev.0
EXECUTIVE SUMMARY REPORT Page 1 of 1
Client:
Location: 5002
Technicians on Board: Adriano Dias Da Silva, Tercio Lessa, Sidiomar Rosa Dias & Greig Mitchell
Project Workscope:
IRM were requested to carry out Installation of Padeyes and Load test on behalf of Ensco
onboard the 5002.This was carried out during the period of Sept 29th to Oct 11th of 2012.
IRM would like to take this opportunity to thank all crew involved for their assistance throughout
this busy operational period.
Project Summary:
The Installation and Load test of Padeyes in the Moonpool was inspected in accordance with
ASME Section V, ASTM E-797, API, ABS, DNV or BV which ever was applicable for the correct
tool. The survey was conducted by using Magnetic Particle & Load test Inspection Equipment to
verify areas of concern.
If found defects, all items found to be defective during this inspection was clearly described and
highlighted within this package of reports.
F-OPE-018a - Revision. 3
MAGNECTIC PARTICLE Page 1 of2
INSPECTION REPORT
Electromagnet / Pull 10lbs : Yes Voltage : 110v Current Flow : No Longitudinal :Yes
Comments:
Areas Inspected:100% Magnetic Particle Inspection was carried out on all exposed stress
areas of the aforementioned items.
F-OPE-009a - Revision.4
MAGNECTIC PARTICLE Page 2 of2
INSPECTION REPORT
Continuation
Customer : Ensco Location : Ensco 5002
P.O. No :10117-00000-12840 IRM.No: IRM-3427 Report No : MPI-IRM3427-003
Details : 100% Magnetic Particle Inspection was carried out on all exposed critical areas.
F-OPE-009a - Revision.4
MAGNECTIC PARTICLE Page 1 of4
INSPECTION REPORT
Electromagnet / Pull 10lbs : Voltage : 110v Current Flow : Yes Longitudinal :Yes
Comments:
Areas Inspected:100% Magnetic Particle Inspection was carried out on all exposed stress
areas of the aforementioned items.
F-OPE-009a - Revision.4
MAGNECTIC PARTICLE Page 2 of4
INSPECTION REPORT
Continuation
Customer : Ensco Location : Ensco 5002
P.O. No :10117-00000-12840 IRM.No: IRM-3427 Report No : MPI-IRM3427-007
Details : 100% Magnetic Particle Inspection was carried out on all exposed critical areas.
F-OPE-009a - Revision.4
MAGNECTIC PARTICLE Page 3 of4
INSPECTION REPORT
Electromagnet / Pull 10lbs : Voltage : 110v Current Flow : Yes Longitudinal :Yes
Comments:
Areas Inspected:100% Magnetic Particle Inspection was carried out on all exposed stress
areas of the aforementioned items.
F-OPE-009a - Revision.4
MAGNECTIC PARTICLE Page 4 of4
INSPECTION REPORT
Continuation
Customer : Ensco Location : Ensco 5002
P.O. No :10117-00000-12840 IRM.No: IRM-3427 Report No : MPI-IRM3427-008
Details : 100% Magnetic Particle Inspection was carried out on all exposed critical areas.
F-OPE-009a - Revision.4
LOAD TEST CERTIFICATION Page 1 of 4
Date: 09/10/2012
The above signature may be created electronically.
This record meets the provisions of the lifting plant and equipment (Records of Test and Examination etc.) Regulations
1992.
F-OPE-010 - Revision. 3
LOAD TEST CERTIFICATION Page 2 of 4
Date: 09/10/2012
The above signature may be created electronically.
This record meets the provisions of the lifting plant and equipment (Records of Test and Examination etc.) Regulations
1992.
F-OPE-010 - Revision. 3
LOAD TEST CERTIFICATION Page 3 of 4
Date: 09/10/2012
The above signature may be created electronically.
This record meets the provisions of the lifting plant and equipment (Records of Test and Examination etc.) Regulations
1992.
F-OPE-010 - Revision. 3
LOAD TEST CERTIFICATION Page 4 of 4
Date: 09/10/2012
The above signature may be created electronically.
This record meets the provisions of the lifting plant and equipment (Records of Test and Examination etc.) Regulations
1992.
F-OPE-010 - Revision. 3