HM TR
HM TR
HM TR
2
HM-TR Series UHF Wireless Transparent Data Transceiver
General
The HM-TR series UHF wireless transparent data transceiver, developed by Hope
Microelectronics Co. Ltd, is designed for applications that need wireless data transmission. It
features high data rate, longer transmission distance, programmable frequencies, configurable
UART formats and low sleep current make it ideal choice. The communication protocol is self
controlled and completely transparent to users. The module can be embedded to your existing
design so that low cost high performance wireless data communication can be utilized easily.
Features
1. FSK (Frequency Shift Keying) modulation, high interference immunity
2. 2-way half-duplex communication
3. 315/433/868/915MHz ISM band, globally license free.
4. Programmable frequencies, allowing be used in FDMA (Frequency Division Multiple
Access) applications
5. Self controlled RF to UART protocol translation, reliable and easy to use.
6. Configurable UART format, with data rate from 300~19200bps
7. Using ENABLE pin to control duty-cycle to satisfy different application requirements
8. High performance, long transmission range. >300m in open area
9. Standard UART interface, with TTL or RS232 logic level available
10. Compact size, standard 0.1” pinch SIP connector and SMA antenna socket
11. No RF tuning needed in application
Application Areas
1.Remote control, remote measurement system 5. Data collection
2. Wireless metering 6. IT home appliance
3. Access control 7. Smart house products
4. Identity discrimination 8. Data store and forward repeater
Note: The ‘232’ version has a on-board MAX232CSE converter, which is not fitted on the ‘TTL’ version
HM-TR v2.2
Parameters
pamameter condition min typical max
Power supply 4.5 5.0 5.0 V
Operate temperature -35 25 80 ℃
TX current HM-TR433 26 mA
HM-TR868 28.5
HM-TR915 30
RX current HM-TR433 15 mA
HM-TR868 16
HM-TR915 17
HM-TR v2.2
continued
Quick Setup
Connect HM-TR/232 to the RS232 connector of serial fitted PC or connect HM-TR/TTL to
MCU(micro controller unit)’s UART directly,apply power supply, both RED and GREEN status
LED will blink 3 times to indicate it is ready for your application. If CONFIG pin is low at power
on, module will enters normal mode for data transmission, or CONFIG is high the module enters
configure mode to setup work parameters
In configure mode, the module work parameters can be setup via the HM-TR setup utility,
with the communication format between module and computer fixed at: 9600, 8, N, 1. see below:
HM-TR v2.2
HM-TR SETUP UTILITY
Ordering Information
Model Logic Level
HM-TRxxx/TTL TTL
HM-TRxxx/232 RS232
232 versions usually are used in PC or equivalent, TTL version suited for simple 5V MCU system.
Logic Level:TTL—TTL
232—RS232