SMG for MEP works

El Sayed Abd El hamied & Co.

Guide
1. Lighting data:
 From folder 12 to rule of thumb to chapter 14 (lighting).
 From ‫ أﺷﺮي‬to ASHRAE fundamentals 2009 to SI to chapter 18
(tables) table2
 From 2004 ASHRAE Standard 90.1 IP Page 65
2. People Occupancy:
 From folder 12 to rule of thumb to chapter 13 (People)
 From ‫ ﻣﻌﺪﻻت اﻟﺘﮭﻮﯾﺔ اﺷﺮي‬to PDF.
 From ASHRAE 2007 to PDF Page 15,16,17 (Occupant Density)
3. Miscellaneous load:
 From ‫ أﺷﺮي‬to ASHRAE fundamentals 2009 to SI to chapter 18
(tables) table 5
 From ASHRAE 2005 to Start to I Agree to IP or SI to Nonresidential
Cooling and Heating Load Calculation Procedures To Page 9 , 10 .
4. Ventilation and Infiltration:
 From folder 12 to Code to chapter 11 (ventilation)
 From ‫ ﻣﻌﺪﻻت اﻟﺘﮭﻮﯾﺔ اﺷﺮي‬to PDF (outdoor Air Requirement).
 From HAP program
 From ASHRAE 2007 to PDF Page 15,16,17 (MINIMUM
VENTILATION RATES IN BREATHING ZONE)
5. Ventilation System:
 From ASHRAE 2007 to PDF Page 19 ( Minimum Exhaust Rates for
accept indoor air Quality)
6. U-Factor (overall heat transition) wall/Roof
 From HAP program
7. U-Factor (overall heat transition) Glass
 From Trane Load Page 29 (Aluminum frame)
8. Glass Factor (Shade Coefficient) SC
 From Carrier Handbook Page (57)
 From Trane Load Page 34 (Aluminum frame)
9. Solar Cooling Load (SCL or q) only in Manual Calculation
 From Carrier Handbook Page (50)

300 El Haram ST,.7 El Athadia Buildings ,. Apartment 504 1Page


0100-7662212 0100-5866711 0122-7685635
SMG for MEP works
El Sayed Abd El hamied & Co.
 From Trane Load Page 33

10.∆T equivalent

∆T equivalent = Equivalent Temperature Difference + Correction to equi Temp


= (1) + (2)
 From Carrier Handbook Page (67) Table 19 If it’s wall (1)
 From Carrier Handbook Page (68) Table 20 a If it’s roof (1)
 From Carrier Handbook Page (68) Table 20 b If it’s roof or wall (2)

10. Activity level Sensible and Latent Heat Gain Per Person (Qs , Ql)
 From HAP program
 From Block load program
 From ‫ أﺷﺮي‬to ASHRAE fundamentals 2009 to SI to chapter 18 Page
(4)
11. ADP
 From Carrier Handbook to Page 148

12. Equivalent length for Duct elbow:

 From Carrier Handbook to Page 197

13. ASHREA Fundamental 2009 (chapter 18) PAGE 6 to find

Q=P/E U.f x L.f (HEAT GAIN FROM ELECTRIC EQUIPMENT)


14 . Weather properties for any Country.

 ASHRAE Fundamental 2009 in the last PDF ( climatic design


information) and search for the country.
 ASHRAE Fundamental 2005 to STRAT then I agree to ( climatic design
information) then search for country and the enter tables of links.

15. SMACNA for Duct Construction from Page 105 to 120.

300 El Haram ST,.7 El Athadia Buildings ,. Apartment 504 2Page


0100-7662212 0100-5866711 0122-7685635
SMG for MEP works
El Sayed Abd El hamied & Co.

Diffuser and Grill Catalogues


1. From ‫ اﻟﺸﻨﺎوي اﻟﺠﺪﯾﺪ‬to Dasco (square Diff. , Grill , Linear Diff.)
2. From ‫ اﻟﺸﻨﺎوي اﻟﺠﺪﯾﺪ‬to Flow line ( to explain linear diffuser too)
3. From ‫ اﻟﺸﻨﺎوي اﻟﺠﺪﯾﺪ‬to ‫ اﻻﻧﺪﻟﺴﯿﺔ‬to Volume Damper