Hyva offers a complete range of tipping valves to be used for different cylinder volumes. The PT 1220 &
2200 valve can be used for flows up to 220 litre per minute. The pressure settings are from 150 to 350 bar.
The PT-valve has fully interchangeable pressure cartridges, so you can adjust the pressure settings yourself.
Dual pressure valves are available as well. For smaller flows you can use the JT valve.
The Hyva PT and JT tipping valves are constructed with a pilot operated pressure relief valve with fixed
pressure setting (by means of cartridges), which protects both the cylinder and the pump for overpressure.
This tipping valve is also designed to allow proportional lowering, which is of main importance when lowering
(half) loaded bodies. This tipping valve can be directly fitted to the Hyva oil tank, which reduces the number
of hoses and fittings and consequently the possibility of leakages.
The Hyva PT-valves & DHM valves can be mounted in line or directly on the oil tank. The PT-valve and the
DHM-valve can be mounted on the same block. The PT-valves are operated by Hyva air control. The DHM-
valves are operated by cable control or by Hyva air control.
The JT valves can also be mounted directly on the cylinder port (SAE).
In this assembly it offers a hose burst safety function.
Other valves
Apart from special tipping valves, Hyva also supplies a variety of flow-, pressure and motion control valves
such as knock-off valves, sequence valves, series and parallel flow control valves, pressure relief valves,
hose failure valves, non return valves, overcentre valves etc.
Hyva also supplies a full range of monoblock and bankable spool valves up to 12 sections with flows from 45
to 160 l/m, various controls and options such as port relief valves and flow control sections.
8
1
82
29 1 : pump connection ( P )
2
4 2A : return tank connection (T)
5
2A 2B : alternative return tank
2B
connection (T)
3 : cylinder connection (C)
3 4 : connection to pneumatic
control - tip (6mm push-in)
5 : connection to pneumatic
control - lower (6mm push-in)
7
7 : pressure gauge point
126
8 : cartridge
Additional part
Part no. Description
147 99 175 Allen plug for PT valve ½”
8B=LP
8A=HP
1
82
1 : pump connection ( P )
4 292 2A : return tank connection (T)
5 2B : alternative return tank
2A connection (T)
2B 3 : cylinder connection (C)
4 : connection to pneumatic
3
control - tip (6mm push-in)
9 5 : connection to pneumatic
7 control - lower (6mm push-in)
7 : pressure gauge point
8 : cartridge
9 : pressure selector
145
LP
HP
4 5
P
3 2 284
1 1: pump connection (P)
8 2: return tank connection (T)
3: cylinder connection (A)
4: pneumatic connection of air
P control-lower (X)
145
1
1
2 2
3 3
1
26
2
77
JT mounting kits
Part no. Description Containing
147 35 160 JT on tank Bolts - washers and o-ring
147 35 162 JT on SAE cylinder port Bolts - washers and o-ring
147 35 207 JT on chassis Bolts - washers - o-ring and plate
1 7
1 6
7
1: pump connection (P)
2: return tank connection (T)
14 3: cylinder connection (A)
6
3 4: cable control connection*
22
3 5: pressure relief valve cap
4 6: knock-off connection (cable)
68
7: non-return valve
2
* Consult Hyva for cable type
3
4
5 14 D
46
14 C
C: tipping
106
D: lowering
48
*4 *3
TANK 2 3/8”G
*2 A : Proportional Lowering
½”G
B : Tipping
IN
*1 : Rest position
A *1 *2 : Tipping
B *3 : Lowering
*4 : test point connection 1/8”G
TANK 1 OUT
¾”G ½”G
*3
IN ¾”G
*2
*4
A : Proportional Lowering
A B : Tipping
*1 : Rest position
*1 TANK ¾”G
*2 : Tipping
*3 : Lowering
B *4 : test point connection 1/8”G
OUT ¾”G
The valve is suitable for remote and tank mounting. For fitment to a standard 3-hole (PT)
mounting plate, use mounting kit 021.418.180. For installations using the native 4-hole
pattern shown above, use mounting kit 021.418.185.
264
2
3
26
M M
4
5
Adapter kit
Part no. Description
021 418 180 Adapter kit 4 hole valve to Hyva 3 hole plate
Mounting flange
Part no. Description
021 418 188 Tank mounting flange 40 - 80 - 150L tip valve
79
°
5mm 219.5
M6 154 021419300
18 202
30 56
Ø10
Ch12
Ø6
M16x1.5
cable fixed position
F P
T
G B
Ø8.5
D
E P
A C
F P
T
G B
Ø8.5
D
E P
A C
80 C
Ø10,5(4x) 3
65 65
80
Ø8,5(4x)
P 1
P: pump connection = 1”
T C: cyl. SAE connect. = 1”
T: tank connection = 1”
52,4
2
26,2 R: pressure relief cartridge
Spare parts
181 pos. part no. description
R
1 147 01 155 body
2 147 01 154 cartridge 150
147 01 156 cartridge 170
3 147 01 157 O-ring
L2
ØD
H 021 418 011
B
L1 P
W P : inlet
A : working port
B : working port
021 418 000 Diverter valve 1"-3/4" 250L-350B OC 350 G1” G¾” 250 2.5
74
38 44 N°4 holes Ø8,5
C2 C1
1/8”
60
X
45
IN
P
60
77.5 71 P : pump connection = 1”
C1 : cylinder connection = ¾”
C2 : cylinder connection = ¾”
X : air connection = 1/8”BSP
L1
L2 SW1 L3
60°
D1
D2
P A
P A
30°
P
40
front of
110
vehicle
¾”BSP
C 258
103
147 00 509
66
45
Ø6,5
5
26
8,
Ø
68
103
66
45
Ø6,5
5
26
8,
Ø
63
Normally
Opened
50
92
Ø1
46
3
5
8,
Ø
27,5 Normally
23,5 50 Closed
70
90
1 90
1 : valve housing
2 : pressure cartridge (14771190)
C : C-port; connect direct to
P
cylinder
52 P : P-port; connect to hose
26,2
,4
A
B
KW C
C
92 (max.)
25
L C : cylinder connection
25
V V : valve connection
H
V
79
Multi-section valve
Part no. Description Press. Ports Flow
(bar) P A/B T (L/min)
147 02 610 Section valve-080-2-DA/SA-180-PN 180 ½” ½” ¾” 80
147 02 620 Section valve-080-2-SA/DA-280-PN 280 ½” ½” ¾” 80
147 02 710 Section valve-080-3-DA/SA/SA-180-PN 180 ½” ½” ¾” 80
147 02 810 Section valve-080-4-DA/DA/SA/SA-180-PN 180 ½” ½” ¾” 80
147 02 815 Section valve-080-4-DA/DA/SA/SA-280-PN 280 ½” ½” ¾” 80
147 02 820 Section valve-080-4-SA/SA/DA/DA-280-PN 280 ½” ½” ¾” 80
147 03 120 Section valve-140-2-DA/SA-280-PN 280 ¾” ¾” 1” 140
147 03 125 Section valve-140-2-DA/SA-170-PN 170 ¾” ¾” 1” 140
147 03 210 Section valve-140-3-SA/DA/DA-170-L 170 ¾” ¾” 1” 140
147 03 220 Section valve-140-3-SA/SA/DA-280-PN 280 ¾” ¾” 1” 140
147 03 310 Section valve-140-4-DA/DA/SA/SA-280-PN 280 ¾” ¾” 1” 140
147 05 500 Section valve-160-3-DA/DA/SA-170-PN 170 1” 1” 1” 160
147 05 550 Section valve-160-3-DA/SA/DA-135-L 135 1” 1” 1” 160
2
1: pump connection (P)
4 8 2: tank connection" (T)
3 3: section 1 connection (A/B)
1 4: section 2 connection (A/B)
5
2 5: air actuator
6: socket for handle
7: pressure relief valve
8: port relief valve
Types
Hydraulic Pressure (BAR) Part Number Description Optional adapter kits Kit number
connections Max.
135 14767213 TIP VALVE HT-TNK/SAE-1150-135-P3/4" 3/4" Straight TNK AK5212TS
150 14767215 TIP VALVE HT-TNK/SAE-1150-150-P3/4" 3/4" 90 degree TNK AK5212TE
P,T & C = 3/4" 170 14767217 TIP VALVE HT-TNK/SAE-1150-170-P3/4" 3/4" Straight SAE AK5212SS
C = SAE 190 14767219 TIP VALVE HT-TNK/SAE-1150-190-P3/4" 3/4" 90 degree SAE AK5212SE
220 14767222 TIP VALVE HT-TNK/SAE-1150-220-P3/4" 1" Straight TNK AK5216TS
250 14767225 TIP VALVE HT-TNK/SAE-1150-250-P3/4" 1" 90 degree TNK AK5216TE
135 14767263 TIP VALVE HT-TNK/SAE-1150-135-P1" 1" Straight SAE AK5216SS
150 14767265 TIP VALVE HT-TNK/SAE-1150-150-P1" 1" 90 degree SAE AK5216SE
T,C=3/4"&
170 14767267 TIP VALVE HT-TNK/SAE-1150-170-P1"
P=1"
190 14767269 TIP VALVE HT-TNK/SAE-1150-190-P1"
C = SAE Mounting kits Kit number
220 14767272 TIP VALVE HT-TNK/SAE-1150-220-P1"
250 14767275 TIP VALVE HT-TNK/SAE-1150-250-P1" Cylinder (SAE)* 14735162
Tank (TNK)* 14735160
* = NOT included with valve
Specifications ∆p - Q characteristic
Type Spool valve with pressureless bypass in neutral. Oil flow in
lowering position is proportional with pneumatic pilot
pressure.
Pressure over Valve (Bar)
Technical notes
• Mount the valve according the mounting instructions • Use the correct washers and adapters in the ports to prevent housing deformation. Do not use
adapters with tapered threads • To further prevent deformation of the valve housing, the mounting plate surface or block must be completely flat and plane. •
Do not weld to the valve. • Ideal air pressure for valve is 8 bar. • Make sure inlet air is dry. • Paint Spec: TN00_00001
Related documentation
Mounting instructions: VAL-0022 OIL Specifications: OIL:0011
WWW.HYVA.COM
Subject to change without notice, no rights reserved Page 1/2 DO-E HT-1150-TNK-SAE / 2014-10-2 / AA
HYVA TIPPING VALVE
HT-1150-TNK / SAE
Spare Parts
No. Part no. Description Qty No. Part no. Description Qty
1 01226200 O-ring 2 7 14845018 Quadring 1
2 14845005 Closing plate for HT-valve 1 8 14845019 Circlip 2
3 14845007 Piston air cylinder 1 9 14845020 Quadring 1
4 14772… Cartridge pressure relief 1 10 14845015 Sealing nut M8 for HT-valve 1
14772135 135 bar 11 14810517 Air coupling 1/8'' 2
14772150 150 bar 12 14845039 Plug 1
14772170 170 bar 13 01206813 Bonded seal 1
14772190 190 bar 14 14841215 O-ring 10,82 x 1,78 1
14772220 220 bar 15 14739980 Non return valve 3/4" 1
14772250 250 bar 14739975A Non return valve 1'' 1
14772280 280 bar 16 15029046 Circlip 1
5 14845024 Plug 1 17 15022015 Washer spring 4
6 14845013 O-ring 1 18 15013639 Bolt HSHC 4
SAFETY
For mounting on HT valve fitted on cylinder (SAE)
● Directly on Hyva cylinder with SAE inlet 3D model is available on request Port offers hose burst safety function
Types
Hydraulic Pressure (BAR) Part Number Description Optional adapter kits Kit number
connections Max.
150 14767454 TIP VALVE HT-SAE-1220-150-P3/4" 3/4" Straight SAE AK5112SS
P = 3/4" & 170 14767456 TIP VALVE HT-SAE-1220-170-P3/4" 3/4" 90 degree SAE AK5112SE
T=1" 190 14767458 TIP VALVE HT-SAE-1220-190-P3/4" 1" Straight SAE AK5116SS
C = SAE 220 14767460 TIP VALVE HT-SAE-1220-220-P3/4" 1" 90 degree SAE AK5116SE
250 14767462 TIP VALVE HT-SAE-1220-250-P3/4"
150 14767455 TIP VALVE HT-SAE-1220-150-P1"
Mounting kits Kit number
170 14767457 TIP VALVE HT-SAE-1220-170-P1"
T & P=1"
190 14767459 TIP VALVE HT-SAE-1220-190-P1" Cylinder (SAE)* 14735175
C = SAE
220 14767461 TIP VALVE HT-SAE-1220-220-P1" * = included with valve
250 14767463 TIP VALVE HT-SAE-1220-250-P1"
Specifications ∆p - Q characteristic
Type Spool valve with pressureless bypass in neutral.
Oil flow in lowering position is proportional with
pneumatic pilot pressure
Technical notes
• Mount the valve according the mounting instructions • Use the correct washers and adapters in the ports to prevent housing deformation. Do not
use adapters with tapered threads • To further prevent deformation of the valve housing, the mounting plate surface or block must be completely
flat and plane. • Do not weld to the valve. • Ideal air pressure for valve is 8 bar. • Make sure inlet air is dry.
• Paint spec: TNO00_00001
Related documentation
Mounting instructions: VAL-0021 OIL Specifications: OIL:0011
WWW.HYVA.COM
Subject to change without notice, no rights reserved Page 1/2 DO-E HT-1220-SAE / 2014-10-2 / AA
HYVA TIPPING VALVE
HT-1220-SAE
Spare Parts
No. Part no. Description Qty No. Part no. Description Qty
1 01226200 o-ring 2 7 14845018 quadring 1
2 14845005 closing plate 1 8 14845019 circlip 2
3 14845007 piston air cylinder 1 9 14845020 quadring 1
4 14772… cartrige pressure relief 1 10 14845015 sealing nut M8 for HT-valve 1
14772150 150 bar 11 14810517 air coupling 1/8'' 2
14772170 170 bar 12 14845039 blind plug 1
14772190 190 bar 13 01206813 bonded seal 1
14772220 220 bar 14 14841215 o-ring 10,82 x 1,78 1
14772250 250 bar 15 14739980 non return valve 3/4" 1
5 14845024 blind plug 1 15 14739975A non return valve 1'' 1
6 14845013 O-ring 1 16 15029046 circlip 1
17 15022015 washer spring 4
18 15013639 bolt HSHC 4
19 01313848 bonded seal 1
For mounting on
● Hyva tank mounting plate 3D model is available on request
Types
Hydraulic Pressure (BAR) Part Number Description Optional adapter kits Kit number
connections Max.
110 14767111 TIP VALVE HT-TNK-1220-110-P1" 1" Straight TNK AK5016TS
135 14767113 TIP VALVE HT-TNK-1220-135-P1" 1" 90 degree TNK AK5016TE
150 14767115 TIP VALVE HT-TNK-1220-150-P1" 1" Straight CHASSIS AK5016CS
170 14767117 TIP VALVE HT-TNK-1220-170-P1" 1" 90 degree CHASSIS AK5016CE
T, C & P=1" 190 14767119 TIP VALVE HT-TNK-1220-190-P1"
220 14767122 TIP VALVE HT-TNK-1220-220-P1"
Mounting kits Kit number
250 14767125 TIP VALVE HT-TNK-1220-250-P1"
280 14767128 TIP VALVE HT-TNK-1220-280-P1" Tank (TNK) * 14735168
350 14767135 TIP VALVE HT-TNK-1220-350-P1" Chassis 14735208
* = included with valve
Specifications ∆p - Q characteristic
Type Spool valve with pressureless bypass in neutral.
Oil flow in lowering position is proportional with
pneumatic pilot pressure.
Pressure over valve (Bar)
Technical notes
• Mount the valve according the mounting instructions • Use the correct washers and adapters in the ports to prevent housing deformation. Do not use
adapters with tapered threads • To further prevent deformation of the valve housing, the mounting plate surface or block must be completely flat and plane.
• Do not weld to the valve. • Ideal air pressure for valve is 8 bar. • Make sure inlet air is dry.
• Paint spec: TNO00_00001
Related documentation
Mounting instructions: VAL-0022 OIL Specifications: OIL:0011
WWW.HYVA.COM
Subject to change without notice, no rights reserved Page 1/2 DO-E HT-1220-TNK / 2014-10-2 / AA
HYVA TIPPING VALVE
HT-1220-TNK
Spare Parts
No. Part no. Description Qty No. Part no. Description Qty
1 14845005 closing plate 1 4 14739975A non return valve 1
2 14845007 piston air cylinder 1 5 14845013 O-ring 1
3 14772… cartridge pressure relief 1 6 14845020 Quadring 1
14772110 110 bar 1 7 14845018 Quadring 1
14772135 135 bar 8 01313848 bonded seal 2
14772150 150 bar 9 14810517 straight coupling 2
14772170 170 bar 10 14845024 blind plug 1
14772190 190 bar 11 14845039 blind plug 1
14772220 220 bar 12 14845040 blind plug 1
14772250 250 bar 13 01226200 O-ring 2
14772280 280 bar
14772350 350 bar
For mounting on
● Hyva tank mounting plate 3D model is available on request
Types
Hydraulic Pressure (BAR) Part Number Description Optional adapter kits Kit number
connections Max. 1* Max. 2*
220 14767152 TIP VALVE HT-TNK-2220-150-220-P1" 1" Straight TNK mounting AK5016TS
250 14767155 TIP VALVE HT-TNK-2220-150-250-P1" 1" 90 degree TNK mounting AK5016TE
150
280 14767158 TIP VALVE HT-TNK-2220-150-280-P1" 1" Straight CHASSIS mounting AK5016CS
350 14767165 TIP VALVE HT-TNK-2220-150-350-P1" 1" 90 degree CHASSIS mount. AK5016CE
220 14767172 TIP VALVE HT-TNK-2220-170-220-P1"
T, C & P=1" 250 14767175 TIP VALVE HT-TNK-2220-170-250-P1"
170 Mounting kits Kit number
280 14767178 TIP VALVE HT-TNK-2220-170-280-P1"
350 14767185 TIP VALVE HT-TNK-2220-170-350-P1" Tank (TNK) ** 14735168
220 14767192 TIP VALVE HT-TNK-2220-190-220-P1" Chassis 14735208
250 14767195 TIP VALVE HT-TNK-2220-190-250-P1" ** = included with valve
190
280 14767198 TIP VALVE HT-TNK-2220-190-280-P1"
350 14767200 TIP VALVE HT-TNK-2220-190-350-P1"
* = The user can choose the maximum pressure limit by using the Pressure Selector (8)
Specifications ∆p - Q characteristic
Type Spool valve with pressureless bypass in neutral.
Oil flow in lowering position is proportional with
pneumatic pilot pressure
Pressure over valve (Bar)
Technical notes
• Mount the valve according the mounting instructions • Use the correct washers and adapters in the ports to prevent housing deformation. Do not use
adapters with tapered threads • To further prevent deformation of the valve housing, the mounting plate surface or block must be completely flat and
plane. • Do not weld to the valve. • Ideal air pressure for valve is 8 bar. • Make sure inlet air is dry.
• Paint spec: TNO00_00001
Related documentation
Mounting instructions: VAL-0022 OIL Specifications: OIL:0011
WWW.HYVA.COM
Subject to change without notice, no rights reserved Page 1/2 DO-E HT-2220-TNK / 2014-9-9 / AA
HYVA TIPPING VALVE
HT-2220-TNK
Spare Parts
No. Part no. Description Qty No. Part no. Description Qty
1 01313848 Bonded Seal 2 6 14845040 Bling Plug 1
2 14739975A Non return valve 1 7 14810517 Straight coupling 2
3 14772… Pressure cartridge 2 8 15013638 Bolt 4
3 14772150 150 bar 9 15022015 Washer 4
3 14772170 170 bar 10 01226200 O-ring 2
3 14772190 190 bar 11 14845007 Piston air cylinder 1
3 14772220 220 bar 12 14845020 Quadring 1
3 14772250 250 bar 13 14845018 Quadring 1
3 14772280 280 bar 14 14845013 O-ring 1
3 14772350 350 bar 15 14845019 Retaining ring 2
4 14845024 Blind Plug 1 16 14845031 Retaining ring 3
5 14845050 PR. Adj. KIT 1