KTM 512
High-performing and compact, these pressure-independent control
valves for variable flow heating and cooling systems are particularly
effective in situations requiring high temperatures and/or pressure
drops. They are also suitable for use on the secondary side in district
heating and comfort cooling systems. Rust protection is assured due
to the electrophoretically painted ductile iron body, while the plug
delivers valve characteristic, suitable for modulating control.
Key features
>> Inline design >> Adjustable flow
Inline flow allows high pressure drops Ensures the design flow.
without noise.
>> Adapters
For use with most available actuators.
Technical description
2
Operating function
DN 15-50
The throttle (2) for flow adjustment, the control valve (9) and the
V+ 1 2 3 4 5 6
diaphragm operated inline the differential pressure controller (6)
are built in series in a common valve body.
Pressure upstream of the throttle acts through an internal
impulse pipe (V+) to the inlet side of the diaphragm (8).
Pressure downstream the control valve acts to the outlet side of
the diaphragm together with a spring force.
The differential pressure controller pressure relieves the control
valve, and at the same time limits the flow to the preset value.
As the control valve is pressure relieved, it is possible to use low
force actuators.
9 8 7
1. Fixing nut
2. Throttle
3. Holes for plombing (throttle)
4. Holes for plombing (valve body)
5. Venting screws
6. Inline differential pressure controller
7. Valve body
8. Diaphragm
9. Control valve
DN 65-125
The control valve (8) and the diaphragm operated inline
1 V+ 2 1 3 4 5
differential pressure controller (4) are built in series in a common
valve body.
Pressure upstream of the control valve acts through an internal
impulse pipe (V+) to the inlet side of the diaphragm (2).
Pressure downstream of the control valve acts to the outlet side
of the diaphragm together with a spring force.
The differential pressure controller pressure relieves the control
valve, and at the same time limits the flow to the preset value.
As the control valve is equipped with lift limitation device,
stepless adjustment of maximum flow is possible. As the
control valve is pressure relieved, it is possible to use low force
actuators.
1. Venting screws
2. Diaphragm
3. Spring
4. Inline differential pressure controller 8 7 6
5. Valve body
6. Flow adjustment screw
7. Fixing nut
8. Control valve
3
IMI TA / Control valves / KTM 512
Sizing
The valve is capable of achieving a maximum flow according to (Valid for max. position, fully open. Other positions will require
the product tables. lower differential pressure, check with the software HySelect.)
Min. differential pressure:
Low flow (LF): 24 kPa (ΔHmin)
Normal flow (NF): 40 kPa (ΔHmin)
High flow (HF): 80 kPa (ΔHmin)
Installation
Install the valve in the return pipe, downstream the consumer, Application example
or in the inlet pipe, upstream the consumer. Flow direction is
shown by the arrow on the valve body.
Install the valve so that venting is possible and the flow
adjustment scale is visible. Check allowed positions of the
actuator.
Installation of a strainer upstream of the valve is recommended.
When filling, vent the body by using the venting screws.
4
Setting
DN 15-50 DN 65-125
Release the fixing nut (1). Turn the flow setting screw (2) Release the fixing nut (7). Turn the flow setting screw (6)
clockwise to the position of 0,0 turns. Turn the flow setting clockwise to the position of 0,0 turns. Turn the flow setting
screw anticlockwise corresponding to the number of turns on screw anticlockwise corresponding to the number of turns on
the flow chart. Tighten the fixing nut. The flow setting can be the flow chart. Tighten the fixing nut.
sealed by using the holes (3a and 3b) on the flow setting screw
7 6
and the valve body.
Table - Example:
Valid table is delivered with each valve.
Measuring accuracy
Kv deviation at different settings (LF/NF/HF)
5
IMI TA / Control valves / KTM 512
For more variants and details on actuators, see separate technical leaflets or
contact IMI Hydronic Engineering.
6
Fig. 1
Force
TA-Slider 1250
TA-Slider 750
TA-Slider 500
Inlet pressure
7
IMI TA / Control valves / KTM 512
B DN 15-50
Male thread – Separate connections optional.
H2
PN 25
ØD
DN d D L H1 H2 B qmax Kg EAN Article No
[m3/h]
H1
LF, low flow
d
15/20 G1 78 110 45 98 83 0,8 1,5 3831112507692 52 796-220
25/32 G1 1/4 97 150 53 94 90 3,2 2,0 3831112507722 52 796-225
L 40/50 G2 125 190 66 94 106 7,6 4,5 3831112507753 52 796-240
NF, normal flow
15/20 G1 78 110 45 98 83 1,0 1,5 3831112507708 52 796-020
25/32 G1 1/4 97 150 53 94 90 3,8 2,0 3831112507739 52 796-025
40/50 G2 125 190 66 94 106 9,5 4,5 3831112507760 52 796-040
HF, high flow
15/20 G1 78 110 45 98 83 1,4 1,5 3831112507715 52 796-420
25/32 G1 1/4 97 150 53 94 90 5,4 2,0 3831112507746 52 796-425
40/50 G2 125 190 66 94 106 12,6 4,5 3831112507777 52 796-440
DN 65-125
Flanges – Do not need any separate connections.
PN 16
→ = Flow direction
8
Articles – Without measuring points (max. 150°C)
B DN 15-50
Male thread – Separate connections optional.
H2
PN 25
ØD
DN d D L H1 H2 B qmax Kg EAN Article No
[m3/h]
H1
d
LF, low flow
15/20 G1 78 110 45 98 55 0,8 1,5 3831112529274 52 761-820
25/32 G1 1/4 97 150 53 94 62 3,2 2,0 3831112529304 52 761-825
L 40/50 G2 125 190 66 94 78 7,6 4,5 3831112529335 52 761-840
NF, normal flow
15/20 G1 78 110 45 98 55 1,0 1,5 3831112529281 52 762-820
25/32 G1 1/4 97 150 53 94 62 3,8 2,0 3831112529311 52 762-825
40/50 G2 125 190 66 94 78 9,5 4,5 3831112529342 52 762-840
HF, high flow
15/20 G1 78 110 45 98 55 1,4 1,5 3831112529267 52 765-720
25/32 G1 1/4 97 150 53 94 62 5,4 2,0 3831112529298 52 765-725
40/50 G2 125 190 66 94 78 12,6 4,5 3831112529328 52 765-740
DN 65-125
Flanges – Do not need any separate connections.
PN 16
→ = Flow direction
9
IMI TA / Control valves / KTM 512
For DN 15-50
For recommended actuators
For DN 65-125
For recommended actuators
10
Connections
For welding
ØD d1 Swivelling nut d1 D L1* EAN Article No
G1 20,8 37 3831112500945 52 759-315
L1 G1 26,3 42 3831112500952 52 759-320
G1 1/4 33,2 47 3831112500969 52 759-325
G1 1/4 40,9 47 3831112500976 52 759-332
G2 48,0 47 3831112501140 52 759-340
G2 60,0 52 3831112501294 52 759-350
With flange
d2
Flange according to EN-1092-2:1997, d1 d2 D L1* EAN Article No
type 16. G1 M12 95 10 3831112501065 52 759-515
ØD d1 Face to face length according to G1 M12 105 20 3831112501072 52 759-520
EN-558-2-1995, serie 1. G1 1/4 M12 115 5 3831112504318 52 759-525
G1 1/4 M16 140 15 3831112501096 52 759-532
G2 M16 150 5 3831112504325 52 759-540
L1 G2 M16 165 20 3831112501317 52 759-550
11
IMI TA / Control valves / KTM 512
Accessories
Measuring point
AMETAL®/EPDM L EAN Article No
44 7318792813207 52 179-014
103 7318793858108 52 179-015
Venting extension
d L Suitable when insulation is used. d D L EAN Article No
Stainless steel/EPDM/Brass. M6 12 70 3831112531727 52 759-220
ØD
Venting screw
Brass/EPDM d EAN Article No
d
M6 3831112527980 52 759-211
The products, texts, photographs, graphics and diagrams in this document may be subject to
alteration by IMI Hydronic Engineering without prior notice or reasons being given. For the most up
to date information about our products and specifications, please visit www.imi-hydronic.com.
6-10-25 KTM 512 v.3 10.2017