Location via proxy:   [ UP ]  
[Report a bug]   [Manage cookies]                

Linseed Oil Treatment

Download as pdf or txt
Download as pdf or txt
You are on page 1of 2

The Euclid Chemical Company

LINSEED OIL TREATMENT


Concrete Sealer

Sealing Compounds
Description
LINSEED OIL TREATMENT is a blend of boiled linseed oil and solvents. When applied in a thin coating to
concrete surfaces, it protects them from winter damage due to freeze-thaw cycling and the effects of de-icing
salts. Two applications of the oil compound will protect concrete and increase its resistance to winter damage.

Primary Applications
• Roads and bridge decks • Concrete exposed to freeze-thaw cycles
• Parking ramps and curbs • Exterior concrete surfaces
• Sidewalks and driveways

Features/Benefits
• Deep penetration • Ease of application
• Salt protection • Rapid drying

Technical Information
Typical Engineering Data
The following results were developed under laboratory conditions.
Suitable for exposure to traffic........4 to 6 hours
Viscosity.................... 25 to 35 sec, #1 Zahn Cup
Percent solids by volume......................min 50%
Flash point.............................. 116°F (47°C) TCC

LINSEED OIL TREATMENT


VOC content..............................................389 g/L
Drying time: 2 hours, depending on humidity and other climatic conditions.

Appearance
LINSEED OIL TREATMENT is a light brown material that will slightly darken concrete.

Packaging
LINSEED OIL TREATMENT is packaged in 55 gal (208 L) drums, and 5 gal (18.9 L) pails.

Shelf Life
2 years in original, unopened container

Specifications/Compliances
• Linseed Oil portion meets ASTM D260
• Mineral Spirits portion meets ASTM D235

Coverage Master Format #:


Troweled Smooth 300 ft2/gal (7.4 m2/L)
07 19 00

Broomed Textured 400 ft2/gal (9.8 m2/L)

Material Requirements
A two coat application using a coverage rate of 300 ft2/gal (7.4 m2/L) for each coat will require approximately 6.7
gal (25.4 L) of material per 1000 ft2 (92.9 m2) of area.

19215 Redwood Road • Cleveland, OH 44110


www.euclidchemical.com
800-321-7628 t • 216-531-9596 f
Directions for Use
Surface Preparation: Concrete surfaces must be clean, dry and free of oil, dirt, loose scale and any other
contaminants. Surfaces shall be swept clean by hand or by mechanical means. Remove oil and grease as
completely as possible. New concrete should be at least twenty-eight days prior to application. New concrete
cured with curing compounds or cure & seals should not be treated until such agents have completely weathered
away or been removed by other means.
Mixing: LINSEED OIL TREATMENT is a one-component product that requires no pre-blending prior to placement.
LINSEED OIL TREATMENT should be used directly from the container.
Placement: LINSEED OIL TREATMENT should be applied sparingly in two coats, at the average rate of 300 ft2/
gal (7.4 m2/L) per coat. Application may be done by medium nap paint roller or industrial pump-up sprayer,
using a wide fan nozzle. The second coat may be applied as soon as the first coat is dry to touch. In warm, dry
weather this requires only one to four hours, but in cool weather, drying times up to 24 hours may be required.
The preferred time for application is late afternoon so that when the concrete cools, the compound penetrates
deep into the pores. Further treatment is recommended in form of a single application annually on surfaces
subject to de-icing chemicals and wear.

Clean-Up
Clean equipment with mineral spirits.

Precautions/Limitations
• Keep LINSEED OIL TREATMENT away from open flames, sparks, or other sources of ignition
• If using LINSEED OIL TREATMENT indoors, ensure adequate fresh air ventilation and block all HVAC ducts which
may distribute solvent odor. Extinguish any pilot lights or other sources of ignition prior to starting LINSEED OIL
TREATMENT application.
• All rags soaked with the compound must be stored in air-tight covered steel drums.
• In all cases, consult the Safety Data Sheet before use.

Rev. 02.17

WARRANTY: The Euclid Chemical Company (“Euclid”) solely and expressly warrants that its products shall be free from defects in materials and workmanship for one (1) year from the date of purchase. Unless authorized
in writing by an officer of Euclid, no other representations or statements made by Euclid or its representatives, in writing or orally, shall alter this warranty. EUCLID MAKES NO WARRANTIES, IMPLIED OR OTHERWISE,
AS TO THE MERCHANTABILITY OR FITNESS FOR ORDINARY OR PARTICULAR PURPOSES OF ITS PRODUCTS AND EXCLUDES THE SAME. If any Euclid product fails to conform with this warranty, Euclid will replace the
product at no cost to Buyer. Replacement of any product shall be the sole and exclusive remedy available and buyer shall have no claim for incidental or consequential damages. Any warranty claim must be made within
one (1) year from the date of the claimed breach. Euclid does not authorize anyone on its behalf to make any written or oral statements which in any way alter Euclid’s installation information or instructions in its product
literature or on its packaging labels. Any installation of Euclid products which fails to conform with such installation information or instructions shall void this warranty. Product demonstrations, if any, are done for illustrative
purposes only and do not constitute a warranty or warranty alteration of any kind. Buyer shall be solely responsible for determining the suitability of Euclid’s products for the Buyer’s intended purposes.

You might also like