TDS - Masterseal110P
TDS - Masterseal110P
110P
Solvented coal tar epoxy resin coating
Description
MASTERSEAL 110P is based on coal tar modified with
epoxy resin and solvent to facilitate spray application. The
excellent adhesion of MASTERSEAL 110P to concrete and
steel afford the product a variety of different applications.
The chemical resistant properties of MASTERSEAL 110P
make it particularly suitable in aggressive environments
such as are found in sewage works.
Primary uses
For the coating of steel, concrete and asbestos cement,
where a heavy duty protective, waterproof, resilient and
abrasion resistant coating is required.
Typical properties*
Pot life at 35C:
Mixed density:
Tack free Time:
Initial cure:
Final cure:
Time to full chemical
resistance:
Coverage:
Dry film thickness on non
porous concrete:
Finished film appearance:
Chemical resistance:
Advantages
Typical applications
Packaging
MASTERSEAL 110P is supplied in 10 litre units.
2 hours
1.35g/cm at 25C
1 hour on concrete
3 hours on metal
10 hours
24 hours
7 days at 25C
4 days at 35C
4-7m/ltr depending on film
thickness
130 microns per coat at 5.4m/litre,
or 0.25kg/m (2 coats
recommended)
Smooth, glossy, dense black
surface
Excellent to most aqueous
systems, sewage, urine, fresh
water, sea water, diluted and
concentrated alkalis, diluted acids,
mineral, vegetable and animal oils
and fats, ammonia, formaldehyde.
Standards
BS 5493.
Guide to application
Surface preparation:
As with all epoxy resin systems, surface preparation is of
prime importance. It is essential that thorough surface
preparation is undertaken to ensure that the system
develops maximum performance.
For concrete surfaces, remove all grease, oil, dust, laitance,
etc., and ensure substrate to receive the coating is sound.
Where necessary cut back and make good.
Mechanical methods of preparation may be necessary to
remove laitance. Concrete cured with curing membranes
should have the membrane removed before application.
Blow holes, pin holes and other surface defects should be
filled with CONCRESIVE 2200.
Metal surfaces should be clean, dry, and free from grease,
oil and rust.
Mixing:
MASTERSEAL 110P is supplied in pre-weighed units
consisting of individually packaged base and reactor.
Note
* Properties listed are only for guidance and are not a guarantee of
performance.
Equipment care
Spray guns, rollers, brushes etc., should be cleaned
immediately after use with CLEANING SOLVENT NO. 2.
Storage
Up to 12 months when stored under cover, out of direct
sunlight and protected from extremes of temperature.
Certificate No.
963680
As all Degussa technical datasheets are updated on a regular basis it is the user's responsibility to obtain the most recent issue.
Certificate No.
945787
Certificate No.
772556