Location via proxy:   [ UP ]  
[Report a bug]   [Manage cookies]                

Az 51079

Download as pdf or txt
Download as pdf or txt
You are on page 1of 7

Order Discontinued as of August 31, 2009

VERTICAL TYPE
LIMIT SWITCHES
AZ5
(INCLUDES LAMP TYPE) Limit Switches
General use vertical limit switch. Type with a lamp which makes maintenance
convenient; either a neon AC powered lamp or an LED DC powered lamp.
2. Lamps that can be used with a wide • Lead wiring type <Current leakage: 0>
range of voltages (LED type only)
• Neon lamp Because the wiring can be made parallel
Comes in two types: 100V AC and to the load, current leakage from the
200V AC , sufficient luminosity is lamp can be reduced to 0. Even with a
achieved through the diamond-cut lens. slight leak, the electronic circuit incurring
Also with a long lifespan of more than 20 the leak can be used safely.
thousand hours. 4. Corrosion-proof, oil-resistant con-
• LED lamp struction
Covers 6V to 48V and comes in three The protective construction is corrosion-
types, 6V AC/DC , 12V AC/DC , and proof (conforms to IP67.) Also, the lens
24 to 48V AC/DC . Uses two highly lumi- and cover are formed simultaneously
Standard type With lamps nescent LEDs and in addition, sufficient with the lamp type, and moreover, a
Roller arm Adjustable roller arm luminosity is achieved through the dia- nameplate is affixed to the upper sur-
mond-cut lens. face, thereby improving the already-
RoHS Directive compatibility information 3. Lamp connection can be either excellent waterproof capabilities.
http://www.nais-e.com/ spring type or lead wire type
• Spring type (wiring unnecessary)
(With neon or LED lamp type)
TYPICAL APPLICATIONS
Conveyer equipment, conveyer belts,
FEATURES Wiring is unnecessary because the lamp
plant facilities, cranes, cleaning plants,
1. Can be mounting either front or is directly connected to the terminals. By
etc. The LED lamp type is also compati-
back. simply changing the direction of the lamp
ble with both PC and computer direct
cover, it is possible to display both lights
4-M6 (P=1.0) current low voltage control circuits.
during operation (normally closed side)
Tapping for the M6
4-5.2 .205 diahole. attachment bolt and no operation (normally open side.)
Through-hole for the M5
attachment bolt

PRODUCT TYPE
1. Standard type
Actuator Part No.
Push plunger AZ5101
Roller plunger AZ5102
Standard type AZ5104
Roller arm
O.T. amplified type AZ5124
Yoke AZ5105
Flexible AZ5106
Standard type AZ5107
Adjustable rod
O.T. amplified type AZ5127
Standard type AZ5108
Adjustable roller arm
O.T. amplified type AZ5128

2. With neon lamp


Lamp rating
Lamp connection Actuator 100V AC 200V AC
Part No.
Push plunger AZ510141 AZ510142
Roller plunger AZ510241 AZ510242
Standard type AZ510441 AZ510442
Roller arm
O.T. amplified type AZ512441 AZ512442
Yoke AZ510541 AZ510542
Spring type
Flexible AZ510641 AZ510642
Standard type AZ510741 AZ510742
Adjustable rod
O.T. amplified type AZ512741 AZ512742
Standard type AZ510841 AZ510842
Adjustable roller arm
O.T. amplified type AZ512841 AZ512842

All Rights Reserved © COPYRIGHT Matsushita Electric Works, Ltd.


Order Discontinued as of August 31, 2009
AZ5
3. With LED
Lamp rating
Lamp connection Actuator 12V DC 24 to 48V DC
Part No.
Push plunger AZ5101161 AZ510116
Roller plunger AZ5102161 AZ510216
Standard type AZ5104161 AZ510416
Roller arm
O.T. amplified type AZ5124161 AZ512416
Yoke AZ5105161 AZ510516
Spring type
Flexible AZ5106161 AZ510616
Standard type AZ5107161 AZ510716
Adjustable rod
O.T. amplified type AZ5127161 AZ512716
Standard type AZ5108161 AZ510816
Adjustable roller arm
O.T. amplified type AZ5128161 AZ512816
Push plunger AZ5101661 AZ510166
Roller plunger AZ5102661 AZ510266
Standard type AZ5104661 AZ510466
Roller arm
O.T. amplified type AZ5124661 AZ512466
Yoke AZ5105661 AZ510566
Lead wire type
Flexible AZ5106661 AZ510666
Standard type AZ5107661 AZ510766
Adjustable rod
O.T. amplified type AZ5127661 AZ512766
Standard type AZ5108661 AZ510866
Adjustable roller arm
O.T. amplified type AZ5128661 AZ512866
Note) Cadmium free contact types are available on a custom-made basis. Please add an “F” to the end of the part number when ordering.
LED rating 6V DC type is available. When ordering, add suffix 162 (spring type) or 662 (lead wire type) to the standard part No..

SPECIFICATIONS
1. Rating 2. Characteristics
1) Standard type Contact arrangement 1 Form A 1Form B
Types of Resistive Inductive Motor or lamp load Initial contact resistance, max. 15mΩ (By voltage drop 6 to 8V DC 1A)
load load load N.C. N.O. Contact material Silver
Rated load (cos φ]1) (cos φ]0.4) contact contact
Initial insulation resistance (At 500V DC) Min. 100MΩ
125V AC 10A 6A 4A 2A 1,000Vrms for 1 min Between non-consective terminals
250V AC 6A 4A 2.5A 1.2A Initial breakdown voltage 2,000Vrms for 1 min Between dead metal parts and each terminal
500V AC 2A 1.2A 0.75A 0.5A 2,000Vrms for 1 min Between ground and each terminal
125V DC 0.8A 0.1A – – Shock resistance 294m/s2 {30G}
Standard type: Max. 55Hz
Vibration resistance
Type with indicator: 10 to 50 Hz, double amplitude of 1.5mm
2) Type with lamp Expected life Mechanical 107 (at 60 cpm)
Rated con- Resistive load Inductive load (Min. operations) Electrical 5105 (at 20 cpm, rated load)
trol voltage (cos φ]1) (cos φ]0.4) Standard type: –5 to +80°C +23 to +176°F
Ambient temperature
With neon 125V AC 10A 6A With indicator: –5 to +60°C +23 to +140°F
lamp 240V AC 6A 4A Ambient humidity Max. 95%R.H.
With LED 24V DC 6A – Max. operating speed 120 cpm

3. Operating characteristics 4. Protective characteristics


Characteristics Movement Repeat Protective AZ5 AZ5 limit switches
Pretravel Overtravel
O.F. (N R.F. (N Differential Totaltravel Accuracy of construction limit switches (With lamp)
(P.T.), max. (O.T.), min. Operating IEC (Standard type) (neon/LED)
Actuator {gf}) max. {gf}) min. (M.D.), max. (T.T.), min. Position, max.
mm inch mm inch
mm inch mm inch*1 IP60  
Push plunger 26.67 {2,720} 8.92 {910} 1.7 .067 1.0 .039 6.4 .252 – 0.1 .004 IP64  
Roller plunger 26.67 {2,720} 8.92 {910} 1.7 .067 1.0 .039 5.6 .220 – 0.1 .004 IP67  
Standard type 13.34 {1,360} 2.23 {227} 15°±5° 12° – 45° 1°
Roller arm
O.T. amplified type 8.83 {900} 0.49 {50} 25°±5° 15° – 90° 1°
Yoke 8.90 {908} 8.90 {908} 50°±5° – – 90°±10° – 5. Lamp rating
Flexible*2 1.39 {142} – 20±10 .787±.394 – – – –
Rated operat- Operating Internal
Adjustable Standard type 1.39 {142} 0.27 {28} 15°±5° 12° – 45° 1° Types
ing voltage voltage range resistance
rod*3 O.T. amplified type 2.39 {244} 0.14 {14} 25°±5° 15° – 90° 1° 100V AC 80 to 120V AC 120kΩ
Adjustable Standard type 13.34 {1,360} 2.23 {227} 15°±5° 12° – 45° 1° neon lamp
200V AC 160 to 240V AC 240kΩ
roller arm*4 O.T. amplified type 8.83 {900} 0.49 {50} 25°±5° 15° – 90° 1° 6V AC/DC 5 to 15V AC/DC 2.4kΩ
*1) Value between max. and min. value in the operating position at 20 cpm, no-load LED lamp 12V AC/DC 9 to 28V AC/DC 4.7kΩ
*2) Measured at the position within 5mm from the top of actuator.
*3) O.F., R.F.: measured at the center distance of 135mm 5.315inch. 24 to 48V AC/DC 20 to 55V AC/DC 15kΩ
*4) O.F., R.F.: measured at the center distance of 38mm 1.496inch.
*5) For the operating characteristics, refer to the TECHNICAL INFORMATION.

FOREIGN STANDARD
Standard Applicable product Part No. Notes
File No. : E99838
Ratings : 10A, 1/2HP, 125V AC Add “9” to the end of the standard Please ask about the price. Comes
UL recognized product
6A, 1/2HP, 250V AC part No. fitted with an earth pin.
Product type : standard model only

All Rights Reserved © COPYRIGHT Matsushita Electric Works, Ltd.


Order Discontinued as of August 31, 2009
AZ5
WIRING DIAGRAM
Output circuit Terminal

N.O.1 N.O.2
N.O.1 N.O.2
N.C.1 N.C.2

N.C.1 N.C.2

DIMENSIONS 17 dia.
mm inch
General tolerance: ±0.4 ±.016
• Push plunger .669
Stainless steel 25.8 Stainless steel 25.8
Standard type Pretravel (P.T.) 9.2±0.2 dia.
.362±.008
plunger 1.016 13.1±0.4 plunger 1.016 13.1±0.4
max. 1.7 .067 .516±.016 .516±.016
Operating 3-M412
position (0.P.) Max. cover screw
33.8±0.8 29.5 25.0 25.0
1.331±.031 1.161 .984 .984

Operation indicator
(for type with lamp)

58.7±0.2 4-M6 P=(1.0) tapped


2.311±.008 min. depth of 15 .591 4-M6 P=(1.0)
+0.2 mounting holes min. depth of 15 .591
4-5.2 –0 dia. mounting holes mounting holes
4.6 min.
.181
G1/2 conduit G1/2 conduit
4.9±0.4 30.2±0.2 Depth min. 7 21.6 Depth min. 7 21.6
.193±.016 1.189±.008 .850 28.7±0.5 .850 28.7±0.5
40
1.575 35 1.130±.020 35 1.130±.020
1.378 40 1.378 42.5
AZ5101 1.575 1.673

Standard With lamp

• Roller plunger General tolerance: ±0.4 ±.016


Standard type 25.8 25.8
1.016 13.1±0.4 1.016 13.1±0.4
17±0.4 dia. stainless steel roller 17 dia. .516±.016 17 dia. .516±.016
Pretravel (P.T.) .669±.016 .669 5±0.4 .669 5±0.4
max. 1.7 .067 .197±.016 .197±.016

TTP 4-M3.512 4-M3.512


Operating 3-M412 Mounting screw Mounting screw
position (0.P.) cover screw
43.8±0.8 Max. 33.1 33.1
1.724±.031 29.5 1.303 1.303
1.161
Operation indicator
(for type with lamp)

58.7±0.2 4-M6 P=(1.0) tapped


2.311±.008 min. depth of 15 591 4-M6 P=(1.0)
+0.2 mounting holes min. depth of 15 .591
4-5.2 0 dia. mounting holes mounting holes
4.6 min.
.181
G1/2 conduit G1/2 conduit
4.9±0.4 30.2±0.2 Depth min. 7 21.6 Depth min. 7 21.6
AZ5102 .193±.016 40 1.189±.008 .850 28.7±0.5 .850 28.7±0.5
1.575 35 1.130±.020 35 1.130±.020
1.378 40 1.378 42.5
1.575 1.673

Standard With lamp

• Roller arm General tolerance: ±0.4 ±.016


Standard type Roller arm can be 58.6 Roller arm can be 58.6
assembled in the 2.307 assembled in the 2.307
53.5 53.5
17.5±0.4 .689±.016 dia. opposite direction 2.106
opposite direction
2.106
stainless steel roller 46.5 46.5
(Roller can be set in any 1.831 39.5 7±04 1.831 39.5
Arm fixing range for position through 360°) 7±04 26 1.555 .276±.157 26 1.555
setting up the roller arm R38.1±0.5 .276±.157 1.024 1.024
in the opposite direction 1.5±.020 13.1±0.4 13.1±0.4
.516±.016 .516±.016
3-M412 M511 4-M3.535 4-M3.535
Cover screws Screw with Head mounting screw Head mounting screw
hexagonal hole
(L90°) (R90°) M511
30.5 Screw with 30.5
14.7 ∗∗ 1.201 hexagonal hole 1.201
.579
Operation indicator
(for type with lamp)

58.7±0.2 4-M6 P=(1.0) tapped


2.311±.008 +0.2 min. depth of 15 .591 4-M6 P=(1.0)
4-5.2 0 dia. min. depth of 15 .591
mounting holes mounting holes
mounting holes
4.6 min.
.181
AZ5104 30.2±0.2 21.6 G1/2 conduit 21.6
4.9±0.4 G1/2 conduit
AZ5124 (O.T. amplified) .193±.016 1.189±.008 .850 28.7±0.5 Depth min. 7 .850 28.7±0.5
40 Depth min. 7
1.575 35 1.130±.020 35 1.130±.020
Weight: 250g 1.378 40 1.378 42.5
53.4±0.8 1.575 53.4±0.8 1.673
2.102±.031 2.102±.031
∗∗Dimension: AZ5104 . . . 14.7 (.059) Standard With lamp
AZ5124 . . . 16.2 (.638)

All Rights Reserved © COPYRIGHT Matsushita Electric Works, Ltd.


Order Discontinued as of August 31, 2009
AZ5
• Yoke 64.3
2.531 (59.2)
64.3
2.531 (59.2)
mm inch
(2.331) (2.331)
Standard type 2-17.5±0.4 dia.
stainless steel roller 7±04
42.8±3.5
1.685±.138 7±04
42.8±3.5
1.685±.138
26 26
Reverse roller .276±.157 1.024 .276±.157 1.024
R38.1±0.5 Rotating rang (270°) 13.1±0.4 13.1±0.4
1.50±.020 .516±.016 4-M3.535 .516±.016 4-M3.535
Fix the arm so that
M511 screw with the reverse roller Head mounting screw Head mounting screw
hexagonal hole can turn within the
rotating range
39.4 39.4
1.551 1.551
14.7 Reverse roller
.579
3-M412
cover screws
Operation indicator 4-M6 P=(1.0) tapped
58.7±0.2
2.311±.008 (for type with lamp) min. depth of 15 .591 4-M6 P=(1.0)
+0.2 mounting holes min. depth of 15 .591
4-5.2 0 dia. mounting holes mounting holes
4.6 min.
.181

4.9±0.4 30.2±0.2 21.6 G1/2 conduit 21.6


G1/2 conduit .850 28.7±0.5 .850 28.7±0.5
.193±.016 40 1.189±.008
Depth min. 7 Depth min. 7
1.575 35 1.130±.020 35 1.130±.020
AZ5105 1.378 40 1.378 42.5
The automatic reverse rotating position of arm 59.4 1.575 59.4 1.673 With lamp
2.339 2.339
is within the range of 40° to 60° from free position.
Standard General tolerance: ±0.4 ±.016
Switch movable
• Flexible rod in any direction
(but not in the
13.1±0.4
.516±.016
13.1±0.4
.516±.016
Max. 6.7 dia. Max. 6.7 dia.
Standard type vertical direction) .264 Nylon rod .264 Nylon rod

25
.984

26 26
140±1.5 1.024 1.024
5.512±.059
Ruber cap and
fixing belt
3-M412
cover screws

Operation indicator
(for type with lamp)

58.7±0.2 4-M6 P=(1.0) tapped


2.311±.008 +0.2 min. depth of 15 .591 4-M6 P=(1.0)
4-5.2 0 dia. min. depth of 15 .591
mounting holes mounting holes
mounting holes
4.6 min.
.181
G1/2 conduit G1/2 conduit
4.9±0.4 30.2±0.2 Depth min. 7 21.6 Depth min. 7 21.6
.193±.016 1.189±.008 .850 28.7±0.5 .850 28.7±0.5
40
AZ5106 1.575 35 1.130±.020 35 1.130±.020
1.378 1.378
40
1.575
42.5
1.673
With lamp
Standard General tolerance: ±0.4 ±.016
6.4
• Adjustable rod .252 46 48.1
1.811 1.894
Standard type
26 26
Adjustable 1.024 13.1±0.4 1.024 13.1±0.4
lenght of rod .516±.016 .516±.016
(max. 141)
4-M3.535 4-M3.535
Head mounting screw Head mounting screw

30.5 30.5
14.7 ∗∗ 1.201 1.201
.579
Operation indicator
(for type with lamp)

58.7±0.2 4-M6 P=(1.0) tapped


min. depth of 15 .591 4-M6 P=(1.0)
AZ5107 2.311±.008 3-M412
cover screws mounting holes min. depth of 15 .591
mounting holes
AZ5127 4.6 min.
.181
(O.T. amplified)
4.9±0.4 30.2±0.2 21.6 G1/2 conduit 21.6
Weight: 252g .193±.016 40 1.189±.008
G1/2 conduit
Depth min. 7
.850 28.7±0.5 Depth min. 7 .850 28.7±0.5
+0.2
4-5.2 0 dia. 1.575 35 1.130±.020 35 1.130±.020
mounting holes 1.378 1.378
40 42.5
1.575 1.673
∗∗Dimensions: AZ5107 . . . 14.7 .578
53.4±0.8
2.102±.031
53.4±0.8
2.102±.031 With lamp
AZ5127 . . . 16.2 .638 Standard General tolerance: ±0.4 ±.016

• Adjustable roller arm 17.5±0.4 dia.


Nylon roller Roller lever can be
64.8±0.8
Roller lever can be
66.4±1.2
2.551±.031 2.614±.047
(Roller can be set in any assembled in the assembled in the
Standard type position through 360°) opposite direction 59.7±1.2 opposite direction 61.3±1.2
2.350±.047 49.3±1.2 2.413±.047 50.9±1.2
7±04 26 1.941±.047 7±04 26 2.004±.047
.276±.157 1.024 .276±.157 1.024
13.1±0.4 13.1±0.4
Adjustable lenght of arm .516±.016 .516±.016
(25 to 90) 4-M3.535
Head mounting screw
M4 fastening screw M4 fastening screw 4-M3.535
Head mounting screw

30.5 30.5
14.7 ∗∗ 1.201 1.201
.579 M5 fastening nut M5 fastening nut
Operation indicator
(for type with lamp)

58.7±0.2 3-M412 4-M6 P=(1.0) tapped


2.311±.008 cover screws min. depth of 15 .591 4-M6 P=(1.0)
mounting holes min. depth of 15 .591
3.2 3.2 mounting holes
.126 .126
4.6 min.
.181

4.9±0.4 30.2±0.2 G1/2 conduit 21.6 G1/2 conduit 21.6


.193±.016 1.189±.008 .850 28.7±0.5 Depth min. 7 .850 28.7±0.5
+0.2
40 Depth min. 7
4-5.2 0 dia. 1.575 35 1.130±.020 35 1.130±.020
AZ5108 mounting holes 1.378 40 1.378 42.5
1.575 1.673
AZ5128 (O.T. amplified) 56.1±0.8 56.1±0.8
With lamp
∗∗Dimensions: AZ5108 . . . 14.7 .579 2.209±.031 2.209±.031

AZ5128 . . . 16.2 .638 Standard General tolerance: ±0.4 ±.016

All Rights Reserved © COPYRIGHT Matsushita Electric Works, Ltd.


Order Discontinued as of August 31, 2009
AZ5
Arm Setting Position Head Block Direction
The roller arm of the arm types (AZ5104, 1. The head block of the arm types 2. The head block of the roller plunger
AZ5105, AZ5107, AZ5108, AZ5124, (AZ5104, AZ5105, AZ5107, AZ5108, type (AZ5102) can be set in two direc-
AZ5127, AZ5128 and each type with AZ5124, AZ5127, AZ5128 and each type tions. Remove the four bushing screws,
lamp) can be set in any position through with lamp) can be set in any of four and set the head in a desired direction.
360°. directions.
Loosen the arm fastening hex. bolt, repo- Loosen four screws on the head, and set
sition the arm, and retighten the hex. the head in a desired direction.
bolt. At this time, change the operation
plunger orientation at the same time.

3-M412 M5 Screw with


hexagonal hole
cover screw

14.7

Operating Direction
1) Both direction 2) Clockwise 3) Counterclockwise
The arm of AZ5104, AZ5107, AZ5108 Remove the head block, turn the notch Remove the head block, turn the notch
and each type with lamp can be set to be of a operating plunger counterclockwise of a operating plunger clockwise in 90°,
operate electrically either to both direc- in 90°, and retighten the head block. and retighten the head block.
tions or only to the right or the left.

*O.T. amplified types “AZ5124, AZ5127


and AZ5128”: only both directions

Roller Direction REVERSE MOUNTING


The roller of the arm types (AZ5104, When a switch is mounted from the
AZ5108, AZ5124, AZ5128 and each type reverse side of a panel, use the mount-
with lamp) can be mounted on the front ing holes in the body.
and rear side. To set the roller on the
rear side, remove the arm fastening hex.
nut, and reinsert the arm so as to face
the roller in the rear direction.
Then, retighten the hex. nut.

(Ex.)
AZ5104

4-M6
(P = 1.0)
Min. depth of
15mm mounting
holes

All Rights Reserved © COPYRIGHT Matsushita Electric Works, Ltd.


Order Discontinued as of August 31, 2009
AZ5
LAMP LIGHTING CIRCUIT
1. Spring type
1) When connecting load to N.O. side: 2) When connecting load to N.C. side: 3) When connecting loads to both N.O.
When the switch is at free position, the When the switch is at free position, the and N.C. sides:
lamp is lit, and when the switch operates, lamp turns off, and when the switch Same as in 1).
the lamp turns off. operates, the lamp is lit. (Use the lamp holder in the same condi-
(Use the lamp holder in the same condi- (Use the lamp holder, changing it dire- tion as when it was at the time of ship-
tion as when it was at the time of ship- cion by 180°.) ment. In this case, it is impossible to use
ment.) it, changing its direction by 180°.)

<With Neon lamp> <With Neon lamp> <With Neon lamp>


Neon lamp Resistor Built-in switch Neon lamp Resistor
3 4
3 4 N.O. 3 4
N.O. Load N.O. Load
N.C.
N.C. Load
1 2 N.C.
1 2
Load
1 2
Resistor
Built-in switch Built-in switch
Neon lamp
AC power source AC power source AC power source

<With LED lamp> <With LED lamp> <With LED lamp>


LED Resistor LED Resistor
Built-in switch

N.O.
3 4

N.O. N.O. Load


Load 3 4
3 4
N.C.
Load N.C.
N.C. 1 2
Load
1 2
1 2

Built-in switch Built-in switch


LED Resistor
Power Power
Power source
source source
No polarity No polarity
No polarity

2. Lead wire type (only for types with LED)


1) When giving indication on N.O. side 2) When the indication circuit is connect-
and N.C. side: ed with load in parallel: LED
Operation is same as that in the case of Load performs the same operation as Resistor
the spring type. However, when load is the indication circuit does.
connected to both N.O. side and N.C. (When load operates, the lamp is lit, and
side, indication can be given on both when load is turned off, the lamp goes N.O.
3 4
Load
N.C. side and N.O. side. out.)
• More loads than for one circuit connot N.C.

be controlled. 1 2

• There is no leakage current. Built-in switch

Power
source
No polarity

CAUTIONS
1. Please use the lamp connection circuit
within the lamp ratings.
2. Nylon is used for a lamp cover. Avoid
using in the atmospheres containing acid
substance.
3. The lamp cover cannot be installed on
previous limit switches.
4. Remove the lamp holder with a v dri-
ver, and insert it in the opposite direction.

All Rights Reserved © COPYRIGHT Matsushita Electric Works, Ltd.


Order Discontinued as of August 31, 2009
AZ5
CAUTIONS
1) This model uses silver terminals. 4) To improve reliability during actual 8) Avoid use in excessively dusty envi-
Therefore, if used at relatively low fre- use, it is recommended that the opera- ronments where actuator operation
quencies for long periods of time, or if tion be checked under installation condi- would be hindered.
used with very small loads, the oxidiza- tions. 9) When used outdoors (in places where
tion that forms on the contact surfaces 5) If OT is too big, the life of limit switch there is exposure to direct sunlight or
will not wear away and eventually cause will be shortened switching friction. Use it rain such as in multistory car parks) or in
improper contact. For such applications, with enough margin of OT. 70% of OT environments where ozone is generated,
use limit switches with gold/metal con- standard value will be good for use. the influence of these environments may
tacts (e.g. VL limit switches) or ones 6) Do not use the switch in a silicon cause deterioration of the rubber materi-
meant for small loads (e.g. HL limit atmosphere. Case should be taken al. Please consult us if you intend to use
switches). where organic silicon rubber, adhesive, a switch in environments such as these.
2) This switch is not designed for under- sealing material, oil, grease or lead wire 10) Do not store in places where organic
water use. Do not use the unit under- generates silicon. gas might be generated or in places of
water. 7) To protect against entry of foreign high dust content or high humidity.
3) Do not use the switch where it may matter from the outside, we recommend
come in direct contact with organic sol- sealing as much as possible using con-
vents, strong acids, strong alkaline liq- duit connectors.
uids or stream, or in atmospheres con-
taining flammable or corrosive gases.

All Rights Reserved © COPYRIGHT Matsushita Electric Works, Ltd.