Az 51079
Az 51079
Az 51079
VERTICAL TYPE
LIMIT SWITCHES
AZ5
(INCLUDES LAMP TYPE) Limit Switches
General use vertical limit switch. Type with a lamp which makes maintenance
convenient; either a neon AC powered lamp or an LED DC powered lamp.
2. Lamps that can be used with a wide • Lead wiring type <Current leakage: 0>
range of voltages (LED type only)
• Neon lamp Because the wiring can be made parallel
Comes in two types: 100V AC and to the load, current leakage from the
200V AC , sufficient luminosity is lamp can be reduced to 0. Even with a
achieved through the diamond-cut lens. slight leak, the electronic circuit incurring
Also with a long lifespan of more than 20 the leak can be used safely.
thousand hours. 4. Corrosion-proof, oil-resistant con-
• LED lamp struction
Covers 6V to 48V and comes in three The protective construction is corrosion-
types, 6V AC/DC , 12V AC/DC , and proof (conforms to IP67.) Also, the lens
24 to 48V AC/DC . Uses two highly lumi- and cover are formed simultaneously
Standard type With lamps nescent LEDs and in addition, sufficient with the lamp type, and moreover, a
Roller arm Adjustable roller arm luminosity is achieved through the dia- nameplate is affixed to the upper sur-
mond-cut lens. face, thereby improving the already-
RoHS Directive compatibility information 3. Lamp connection can be either excellent waterproof capabilities.
http://www.nais-e.com/ spring type or lead wire type
• Spring type (wiring unnecessary)
(With neon or LED lamp type)
TYPICAL APPLICATIONS
Conveyer equipment, conveyer belts,
FEATURES Wiring is unnecessary because the lamp
plant facilities, cranes, cleaning plants,
1. Can be mounting either front or is directly connected to the terminals. By
etc. The LED lamp type is also compati-
back. simply changing the direction of the lamp
ble with both PC and computer direct
cover, it is possible to display both lights
4-M6 (P=1.0) current low voltage control circuits.
during operation (normally closed side)
Tapping for the M6
4-5.2 .205 diahole. attachment bolt and no operation (normally open side.)
Through-hole for the M5
attachment bolt
PRODUCT TYPE
1. Standard type
Actuator Part No.
Push plunger AZ5101
Roller plunger AZ5102
Standard type AZ5104
Roller arm
O.T. amplified type AZ5124
Yoke AZ5105
Flexible AZ5106
Standard type AZ5107
Adjustable rod
O.T. amplified type AZ5127
Standard type AZ5108
Adjustable roller arm
O.T. amplified type AZ5128
SPECIFICATIONS
1. Rating 2. Characteristics
1) Standard type Contact arrangement 1 Form A 1Form B
Types of Resistive Inductive Motor or lamp load Initial contact resistance, max. 15mΩ (By voltage drop 6 to 8V DC 1A)
load load load N.C. N.O. Contact material Silver
Rated load (cos φ]1) (cos φ]0.4) contact contact
Initial insulation resistance (At 500V DC) Min. 100MΩ
125V AC 10A 6A 4A 2A 1,000Vrms for 1 min Between non-consective terminals
250V AC 6A 4A 2.5A 1.2A Initial breakdown voltage 2,000Vrms for 1 min Between dead metal parts and each terminal
500V AC 2A 1.2A 0.75A 0.5A 2,000Vrms for 1 min Between ground and each terminal
125V DC 0.8A 0.1A – – Shock resistance 294m/s2 {30G}
Standard type: Max. 55Hz
Vibration resistance
Type with indicator: 10 to 50 Hz, double amplitude of 1.5mm
2) Type with lamp Expected life Mechanical 107 (at 60 cpm)
Rated con- Resistive load Inductive load (Min. operations) Electrical 5105 (at 20 cpm, rated load)
trol voltage (cos φ]1) (cos φ]0.4) Standard type: –5 to +80°C +23 to +176°F
Ambient temperature
With neon 125V AC 10A 6A With indicator: –5 to +60°C +23 to +140°F
lamp 240V AC 6A 4A Ambient humidity Max. 95%R.H.
With LED 24V DC 6A – Max. operating speed 120 cpm
FOREIGN STANDARD
Standard Applicable product Part No. Notes
File No. : E99838
Ratings : 10A, 1/2HP, 125V AC Add “9” to the end of the standard Please ask about the price. Comes
UL recognized product
6A, 1/2HP, 250V AC part No. fitted with an earth pin.
Product type : standard model only
N.O.1 N.O.2
N.O.1 N.O.2
N.C.1 N.C.2
N.C.1 N.C.2
DIMENSIONS 17 dia.
mm inch
General tolerance: ±0.4 ±.016
• Push plunger .669
Stainless steel 25.8 Stainless steel 25.8
Standard type Pretravel (P.T.) 9.2±0.2 dia.
.362±.008
plunger 1.016 13.1±0.4 plunger 1.016 13.1±0.4
max. 1.7 .067 .516±.016 .516±.016
Operating 3-M412
position (0.P.) Max. cover screw
33.8±0.8 29.5 25.0 25.0
1.331±.031 1.161 .984 .984
Operation indicator
(for type with lamp)
25
.984
26 26
140±1.5 1.024 1.024
5.512±.059
Ruber cap and
fixing belt
3-M412
cover screws
Operation indicator
(for type with lamp)
30.5 30.5
14.7 ∗∗ 1.201 1.201
.579
Operation indicator
(for type with lamp)
30.5 30.5
14.7 ∗∗ 1.201 1.201
.579 M5 fastening nut M5 fastening nut
Operation indicator
(for type with lamp)
14.7
Operating Direction
1) Both direction 2) Clockwise 3) Counterclockwise
The arm of AZ5104, AZ5107, AZ5108 Remove the head block, turn the notch Remove the head block, turn the notch
and each type with lamp can be set to be of a operating plunger counterclockwise of a operating plunger clockwise in 90°,
operate electrically either to both direc- in 90°, and retighten the head block. and retighten the head block.
tions or only to the right or the left.
(Ex.)
AZ5104
4-M6
(P = 1.0)
Min. depth of
15mm mounting
holes
N.O.
3 4
be controlled. 1 2
Power
source
No polarity
CAUTIONS
1. Please use the lamp connection circuit
within the lamp ratings.
2. Nylon is used for a lamp cover. Avoid
using in the atmospheres containing acid
substance.
3. The lamp cover cannot be installed on
previous limit switches.
4. Remove the lamp holder with a v dri-
ver, and insert it in the opposite direction.