Location via proxy:   [ UP ]  
[Report a bug]   [Manage cookies]                

Clorius Actuator CAR

Download as pdf or txt
Download as pdf or txt
You are on page 1of 4

Electric Valve Actuator type CAR 4.11.

08-C
For 3-way valves type L3FM-T, M3FM-T, G3FM-T GB-1

Application Mounting
Electric valve actuator type CAR is spe- For mounting and starting up , the instruc-
cially designed to meet the demands tions delivered with the actuator must be
of the powerful low frequency vibration followed carefully.
environments in marine installations.
The main applications are cooling of fresh-
water, sea water and lubricating oil sys- Service
tems for main and auxiliary engines. The
No special service is needed. It is recom-
actuator is used for Clorius 3-way valves
mended to check and grease the actuator
type L3FM-T, M3FM-T and G3FM-T.
at every docking or every three years.

Technical data
Casing: Watertight IP67, Nema 4 and 6
Ambient temp.: -30°C to +70°C, 150°C/1 hr.
Power Supply: 120/230 VAC, 1-Phase (50Hz/60Hz)
380/400/440 VAC, 3-Phase (50Hz/60Hz)
24 VDC (CAR 015-028)
Torque switches: Open/Close
Limit switches: Open/Close, additional limit switches on request
Stall protection: Built-in Thermal Protection Recommended actuator
Cut-off at 150°C ± 5°C / Reset at 97°C ±15°C types for G3FM-T valves
Travel angle: 90° ± 5°
Indicator: Continuous Position Indicator Actuator type
Valve size
Manual override: AUTO Declutching Mechanism DP 5 bar DP 16 Bar
Worm gear: Permanently lubricated and Self-locking
DN 200
Mechanical stops: External Adjustable Limit Stops CAR 028 CAR 060
Space heater: 20 W (115/230 VAC, 24 VDC) DN 250
Anti-Condensation DN 300 CAR 060
Cabeling: 2 x R ¾”
DN 350 CAR100
Lubrication: Grease NLGI Grade 2 (EP-Type) CAR 100
Materials: Steel, Aluminium Alloy, Al Bronze DN 400
External coating: Anodizing and Dry Powder Epoxy DN 450
Duty Cycle: On-Off: S2 50%
DN 500 CAR 200 CAR 200
Modulating: S4 75%
DN 600

Specifications
Max. Operating time Weight No. of Current draw Current draw Current draw Current draw
Type torque sek/90° kg handle max. A max. A max. A max. A
Nm (50/60 Hz) turns (1-phase 120V) (1-phase 230V) (3-ph 400V) (24 VDC)
CAR 028 274 24/20 17 12.5 2 0.7 0.3 7
CAR 060 588 29/24 22 14.5 3.1 1.18 0.5 -
CAR 100 981 29/24 25 14.5 4.5 2 0.87 -
CAR 150 1471 87/72 68 43.5 3.1 1.18 0.5 -
CAR 200 1962 87/72 70 43.5 4.5 1.8 0.8 -

Subject to changes without notice.

Clorius Controls A/S


Tempovej 27 · DK-2750 Ballerup · Denmark
Tel.: +45 77 32 31 30 · Fax: +45 77 32 31 31
E-mail: mail@cloriuscontrols.com
Web: www.cloriuscontrols.com
Electric Valve Actuator type CAR 4.11.08-C
For 3-way valves type L3FM-T, M3FM-T, G3FM-T GB-2

Dimension sketch

CAR 028 - 100 CAR 150 - 200

Flange
ISO 5211 Flange
ISO 5211

Type CAR 028 CAR 038 CAR 060 CAR 100 CAR 150 CAR 200
Flange F12, F10 F14, F12 F16, F14*
C1 125 140 165
C2 102 125 140*
A1 M12 M16 M14*/M16*
A2 M10 M12 M20
B 18 22 30
D(Max**) 32 42 75
E 75 85 100
F 52 59 126
G 2 2 7
H 70 78 78
I 159 191 191
J 250 283 283
K - - 195
L 145 175 266
M 83 99 99
N 202 226 226
O 125 170 170
P - - 16
R 130 178 178
T 99 116 116
U - - 388
V - - 318
W - - 556
X 285 325 325
Y 258 307 307
Z 320 361 361
* For optional alternative flanges
** Maximum dimension including keyway Subject to changes without notice.

Clorius Controls A/S


Tempovej 27 · DK-2750 Ballerup · Denmark
Tel.: +45 77 32 31 30 · Fax: +45 77 32 31 31
E-mail: mail@cloriuscontrols.com
Web: www.cloriuscontrols.com
Electric Valve Actuator type CAR 4.11.08-C
For 3-way valves type L3FM-T, M3FM-T, G3FM-T GB-3

Accessories

CAR Proportional Control unit PCU PB90 CAR 028-200

4-20 mA, nominal input impedance 150 Ohm,


Command signal jumpers I1 and 12
input 0-10 V, nominal input impedance 260k Ohm,
jumper V1
Analogue feed- 4-20 mA, self powered, can drive up to 300
back signal Ohm
3,15 AT 5x20 mm, mounted on the PB90
Fuse
card Position board
Resolution Approx. 0,3%
12 bit maximum. Normal range (4-20 mA) =
Conversion
1/3200.
Position board. Characteristic of feedback element and actuator
system response affect the true performance.

CAR Current PositionTransmitter CPT CAR 028-200

• For continuous, analogue feed back


signal 4-20 mA
• R/I Transmitter
• The electronic components are pro-
tected against dirt and similar

Subject to changes without notice.

Clorius Controls A/S


Tempovej 27 · DK-2750 Ballerup · Denmark
Tel.: +45 77 32 31 30 · Fax: +45 77 32 31 31
E-mail: mail@cloriuscontrols.com
Web: www.cloriuscontrols.com
Electric Valve Actuator type CAR 4.11.08-C
For 3-way valves type L3FM-T, M3FM-T, G3FM-T GB-4

Accessories

CAR Potentiometer PIU CAR 028-200

• For CAR 006 - CAR 250


• For continuous position feedback from
0º to 90º
• The whole unit is built into the actua-
tor
• Potentiometer 1k Ohm, senses the
actuator position during the whole
turning movement
• Mounting details included
• Resistance 1k Ohm
• Resistance tolerance ±20%
• Linearity ±1%
• Max load 1W at +70 ºC

CLS: Close Limit Switch


OLS: Open Limit Switch
CTS: Close Torque Switch
OTS: Open Torque Switch
ACLS: Aux. Close Limit Switch
AOLS: Aux. Open Limit Switch
TP: Thermal Protector

Subject to changes without notice.

Clorius Controls A/S


Tempovej 27 · DK-2750 Ballerup · Denmark
Tel.: +45 77 32 31 30 · Fax: +45 77 32 31 31
E-mail: mail@cloriuscontrols.com
Web: www.cloriuscontrols.com