Questions: National Building Code of The Philippines

Download as docx, pdf, or txt
Download as docx, pdf, or txt
You are on page 1of 2

Questions: National Building Code of the Philippines

1. Qualifications of Building Officials.

2. Types of Construction.

3. Application for permits.

4. Means the degree to which the material can withstand fire as determined by generally recognized
and accepted testing methods.

5. Give at least 4 types of occupancy separation.

6. Section 505. Center Lines of Streets states that the center line of an adjoining street or alley may
be considered an_____________ distance shall be measured at _____________ to the streets or
alley.

7. The measurement of site occupancy or lot occupancy shall be taken _______ and shall be
exclusive of courts, yards, and light wells.

8. What is the total free area of window or windows opening of every room not provided with
artificial ventilation system?

9. All pipe materials to be used in buildings shall conform to the _________.


10. It is a permanent roofed structure above a door attached to and supported by the building and
projecting over a wall or sidewalk. This includes any object or decoration attached thereto.

11.______ is a non-structural facing of brick, concrete, tile, metal, plastic, glass, or other similar
approved materials attached to a backing or structural components of the building for the purpose
of ornamentation, protection, or enclosure that may be adhered, integrated, or anchored either on
the interior or exterior of the building or structure.

12. ______ shall be enclosed depending upon the fire-resistive requirements of a particular type of
construction as set forth in this Code.

13. Give at least 3 Protective Devices for the pedestrians during demolition and/or construction.

14. Give at least 2 classes of approved plastics in chapter 17 section 1601.

15. What is prefabricated assembly?

16. Give at least 3 classes of film that is exempted in chapter 14 section 1402.

17. The area of a paint spray booth shall not exceed _________ square meters not ________ percent
of the basic area permitted for the major of the building according to its Occupancy Group.

18. Standards for materials shall conform to the provisions set by the Secretary on glass
______________, ______________, ______________.

19. Section 2001. General Requirements (a) No sign or signboard shall be erected in such manner
as to confuse or obstruct the view or interpretation of any official traffic sign, signal, or device.

20. Section 2105. Effectivity - This Decree shall take effect upon its promulgation. Done in the City
of Manila, this 19th of February, in the year of Our Lord,_________.
Answer:
1. A Filipino citizen and of good moral character, A duly registered architect or civil engineer, A
member of good standing of a duly accredited organization of his profession for not less than two
years, Has at least five years of diversified and professional experience in building design and
construction.

2. Type I. Type I buildings shall be a wood construction. The structural elements may be any of the
materials permitted by this Code. Type II. Type II buildings shall be of wood construction with
protective fire-resistant materials and one-hour fire resistive throughout: Except, that permanent
non-bearing partitions may use fire-retardant treated wood within the framing assembly. Type III.
Type III buildings shall be of masonry and wood construction. Structural elements may be any of
the materials permitted by this Code: Provided that the building shall be one-hour fire-resistive
throughout. Exterior walls shall be of incombustible fire-resistive construction. Type IV. Type IV
buildings shall be of steel, iron, concrete, or masonry construction. Walls, ceiling, and permanent
partitions shall be of incombustible fire resistive construction: Except, that permanent non-bearing
partitions of one-hour fire-resistive construction may use fire-retardant treated wood within the
framing assembly. Type V. Type V buildings shall be fire-resistive. The structural elements shall be
of steel, iron, concrete, or masonry construction. Walls, ceilings, and permanent partitions shall be
of incombustible fire-resistive construction.

3. A description of the work to be covered by the permit applied for; Certified true copy of the TCT
covering the lot on which the proposed work is to be done. If the applicant is not the registered
owner, in addition to the TCT, a copy of the contract of lease shall be submitted; The use or
occupancy for which the proposal work is intended;

4. Fire Resistive Rating.

5. 1 hour fire resistive occupancy, 2 hour fire resistive occupancy,3 hour fire resistive occupancy,4
hour fire resistive occupancy.

6. Adjacent property & Right Angles.

7. at the ground level

8. At least 10%

9. Standard Specifications of the Philippine Standard Council

10. Canopy or Marquee

11. Veneers

12. Vertical Openings


13. Railings, - canopies, -fences

14. Electrical conduits, sewage pipes, PVC insulation Cables, Insulation Tape, Vinyl Tiles, Storage
tanks

15. Prefabricated assembly is a structural unit, the integral parts of which have built up or
assembled prior to incorporation in the building.

16. Film for amateur photographic; safety film; dental X-ray film; establishments manufacturing
photographic films

17. 150 & 10

18. Dimensional tolerances, breaking stress levels, and design safety factors

19. Confuse or obstruct

20. 1977